• Title/Summary/Keyword: On-Ground Facilities

Search Result 612, Processing Time 0.027 seconds

A Impact Analysis of Air Quality by Air Pollution Control Facilities Improvement on Point Source Pollution (점오염원의 대기오염방지시설 개선에 의한 대기질 영향 분석)

  • Jeon, Byeong-Geun;Lee, Sang-Houck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2876-2882
    • /
    • 2015
  • The object of this study is to identify changes in air pollution in the maximum ground level concentration and the surrounding area when air pollution control facilities are improved in the thermal power plants. The effects of improved facilities are analyzed by comparing air quality after applying improved air pollution control facilities. For prediction of air quality, the change of wind field can be represented with movement of Puff and CALPUFF Model, air pollution diffusion models which can implement abnormal conditions. Major air pollutants of thermal power plants such as $SO_2$, $NO_2$, and $PM_{10}$ are selected as prediction items. That results show that improvement of air pollution control facilities is significantly effective in reduction of air pollution of $SO_2$ and $NO_2$ in the maximum ground level concentration and areas around of thermal power plants. In the case of $PM_{10}$, it is found that the effect of reduction in pollution is high in the maximum ground level concentration, but the effect of reduction in air pollution is somewhat low in the area around of the thermal power plant.

Strong Ground Motion Simulation at Seismic Stations of Metropolises in South Korea by Scenario Earthquake on the Causative Fault of the 2016 Gyeongju Earthquake (2016년 경주지진 유발단층 시나리오 지진에 의한 국내 광역 도시 지진관측소에서의 강진동 모사)

  • Choi, Hoseon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.59-65
    • /
    • 2020
  • The empirical Green's function method is applied to the foreshock and the mainshock of the 2016 Gyeongju earthquake to simulate strong ground motions of the mainshock and scenario earthquake at seismic stations of seven metropolises in South Korea, respectively. To identify the applicability of the method in advance, the mainshock is simulated, assuming the foreshock as the empirical Green's function. As a result of the simulation, the overall shape, the amplitude of PGA, and the duration and response spectra of the simulated seismic waveforms are similar with those of the observed seismic waveforms. Based on this result, a scenario earthquake on the causative fault of Gyeongju earthquake with a moment magnitude 6.5 is simulated, assuming that the mainshock serves as the empirical Green's function. As a result, the amplitude of PGA and the duration of simulated seismic waveforms are significantly increased and extended, and the spectral amplitude of the low frequency band is relatively increased compared with that of the high frequency band. If the empirical Green's function method is applied to several recent well-recorded moderate earthquakes, the simulated seismic waveforms can be used as not only input data for developing ground motion prediction equations, but also input data for creating the design response spectra of major facilities in South Korea.

A Method of Developing a Ground Layer with Risk of Ground Subsidence based on the 3D Ground Modeling (3차원 지반모델링 기반의 지반함몰 위험 지반 레이어 개발 방법)

  • Kang, Junggoo;Kang, Jaemo;Parh, Junhwan;Mun, Duhwan
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.12
    • /
    • pp.33-40
    • /
    • 2021
  • The deterioration of underground facilities, disturbance of the ground due to underground development activities, and changes in ground water can cause ground subsidence accidents in the urban areas. The investigation on the geotechnical and hydraulic factors affecting the ground subsidence accident is very significant to predict the ground subsidence risk in advance. In this study, an analysis DB was constructed through 3D ground modeling to utilize the currently operating geotechnical survey information DB and ground water behavior information for risk prediction. Additionally, using these results, the relationship between the actual ground subsidence occurrence history and ground conditions and ground water level changes was confirmed. Furthermore, the methodology used to visualize the risk of ground subsidence was presented by reconstructing the engineering characteristics of the soil presented according to the Unified Soil Classification System (USCS) in the existing geotechnical survey information into the internal erosion sensitivity of the soil, Based on the result, it was confirmed that the ground in the area where the ground subsidence occurred consists of more than 40% of sand (SM, SC, SP, SW) vulnerable to internal erosion. In addition, the effect of the occurrence frequency of ground subsidence due to the change in ground water level is also confirmed.

Grounding Grid Design Considering the Dangerous Voltage of Multi-layered Model in the Constrained Sites (제한된 부지 다층 대지구조에서 위험전압을 고려한 접지설계)

  • Son, Seok-Geum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.3
    • /
    • pp.139-144
    • /
    • 2013
  • In Korea, where most of the sites are narrow in space and their earth resistivity is relatively high, the spaces between grounding conductors are likely to be designed narrow in order to lower ground resistance and dangerous voltage below to the permitted safety values. In addition, ground nets are in the shape of square or rectangle depending on the location and size of the facilities and ground contact area, and inner conductors are laid out in grids like the pattern of nets. Nevertheless, with the existing designs, the marginal voltage for safety gets higher as the area is extended further outside, in comparison with that of inner mesh grounding, thus causing much difficulty maintaining them equipotential, and there exist limits in the burial, grounding grid design considering the dangerous voltage of muti-layered model in the constrained sites, was studied.

A study on an earthing system without ground connection (대지에 매설할 필요가 없는 접지시스템에 관한 연구)

  • Seol, Dong-Hwa;Kim, Chang-Bong;Woo, Jea-Wook
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.258-261
    • /
    • 2009
  • This paper proposes an earthing system without ground connection. As a Green IT Environmental Solution, Internal-external surge and other unnecessary electric currents are converted into energy and through a discharge the signal is reduced. It's a structure that discharges through a neutral electric transformer. The results show that the electric potential rising of the earthing system proposed in this paper are approximately below the half and the discharge currents increased approximately 9 times when compared to existent earthing systems. This earthing system is economical, easy to install and can solve environmental contamination.

  • PDF

A Study on the Safety Measures of Camping Ground Fire (야영장 화재 안전대책에 관한 연구)

  • Choi, Ji-Hun;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.57-64
    • /
    • 2016
  • The leisure life pattern of people is changing to a familial and enthusiastic way that eventually develops the camping culture. Thus, the number of campers and the size of camping market have been dramatically increased due to significant expansion of camping people. However, many camp grounds and facilities are operating without a proper registration by government rules and regulations. In addition, many of electronic and gas equipment and tools are not used in a safe way and in a safety regulatory boundary. Therefore, campers at the camping ground is situated in a fire and safety hazard. In addition, there is limitation in rules and regulations associated with camping ground safety and fire. This study analyzed the fire and hazard guidelines and rules regulations of developed countries of campground and compared them to the current situation in South Korea. Therefore, this study is to develop a safety and fire hazard guidelines and rules and regulations related to camp ground operation, gas and electronic equipment operation and management. The study will eventually reduce the future fire and safety incidents in a campground in South Korea.

A Study on the Problems of elementary School Safety and its Improvement in Korea (우리나라 초등학교 학교안전의 문제점 및 개선방향에 관한 연구)

  • Yoon, Yong-Gi
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.13 no.3
    • /
    • pp.1-14
    • /
    • 2014
  • This research aims to orientation for new ways to improve school safety environment composition : The first study was the survey of various literature and status on primary school safety has been established in residential developments in urban areas were investigated and analyzed. This study was constructed as follows : The first chapter of the study is composed with the purpose, contents and configuration of study, definitions of terms, and consists of a limitation of such studies. And in chapter 2, we define such concepts, the range of school safety incidents. In Chapter 3, the nation's school safety situation was investigated, And in the fourth chapter introduced the practice of foreign school safety plan, Chapter 5 was to provide direction for future school safety and accident prevention plan. Including 12 new elementary school in Dongbaek district and Dongtan New-Town 20 new elementary schools in the metropolitan area of New-City were examined for safety issues, such as the environment of school, school zones, school premises form compositions and its outdoor and indoor facilities. This study was aimed at some of the nation's metropolitan New Town Elementary School. Therefore, there is a limit to this generalization. Also planned construction safety plan elements for the indoor facilities are further studies are needed for this hayeoteumeuro excluded. In addition, the architectural planning elements of the school safety needs additional studies is excluded.

Study on the Applicability of Standard Design Response Spectrum Analysis Method for Pile-type Mooring Facilities (말뚝식 계류시설의 표준설계응답스펙트럼 해석법 적용성 연구)

  • Oh, Jeong-Keun;Jeong, Yeong-Seok;Kwon, Min-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.27-36
    • /
    • 2020
  • The purpose of this paper is to study on the applicability of the standard design response spectrum from the response spectrum analysis method, mainly applied to pile mooring facilities. To this end, after performing the ProShake 1-dimensional site response considering various geological conditions, the current standard design response spectrum was compared, and the ground-pile model in time history and two-dimensional site response analysis using Abaqus were performed to analyze the dynamic behavior of the ground-pile and to examine the selection method of the reference surface of the response spectrum on the installed slope, respectively. As a result, it was confirmed that no problems were found in the applicability of the current standard design response spectrum and no improvements are needed as well when considering the characteristics of the ground-pile dynamic behavior and the slope of the pile mooring facility.

A Study on Energy-saving Landscape Facilities through a Park User's Attitude Survey - Focused on Urban Parks in Gimpo - (공원이용자 의식조사를 통한 에너지 절약형 조경시설물 도입에 대한 연구 - 김포시 근린공원을 중심으로 -)

  • Doo, Chul-Eon;Lee, Jae-Keun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.3
    • /
    • pp.17-28
    • /
    • 2012
  • This study aims to present the ground for the introduction of energy-saving landscape facilities which can meet the requirements of the age and create a new space by introducing the facilities which saves energy and that users prefer at the space where urbanites enjoy leisure activities in the urban parks. Thus, in addition to a spatial analysis of the parks for 10 urban parks in Gimpo, through an attitude survey on the users' behaviors, the following conclusions were drawn out. First, as a result of putting all facilities in the urban parks in Gimpo, on average, 6.9 out of the standards of 9 (76.6%) have been installed, and as a result of an analysis on the total number of the installed facilities, on average, about 28 kinds of facilities have been installed, so only 22.4% of the total 125 facilities were installed. Second, many urbanites are using the parks for the purpose of taking a walk and exercise to improve their health; however, the legal standards regulate only 2.9 exercise facilities on average in the target area, which are somewhat insufficient. Third, regarding the citizens' intent to participate in responding to climate change, 76% of them showed their intention of participation. Thus, if the energy-saving facilities, the purpose of this study, are introduced, many users will use them, and it is judged that costs for existing street lights and electric power plants will decrease. Fourth, as a result of an analysis of their satisfaction with the facilities, the value of R-square meaning the explanatory power of the independent variables put in a linear model for dependent variables was 0.860, approximately 81% of the total satisfaction, which was a high explanatory power. This study conducted an attitude survey on the users of urban parks in Gimpo at the dimensions of the introduction of energy-saving facilities in the urban parks, the national policies and responses to climate change. It is significant that it identified the appropriateness of developing much more energy-saving landscape facilities needed for low-carbon green growth in various types, and as a subsequent project, a more precision study on this is necessary continuously.

A Study on the Upper Ground Reinforcement Effect in Underground Cavern (지하공동 상부지층 보강효과에 관한 연구)

  • Kim, Ki Ho;Lim, Jong Se;Jang, Won Yil
    • Tunnel and Underground Space
    • /
    • v.25 no.3
    • /
    • pp.275-283
    • /
    • 2015
  • Excavation of underground space in soft ground implicate to the structure, such as subsidence. As a result, it has been acting as a serious risk to the stability of the roads and facilities. Therefore, in order to stabilize the soil stabilization and reinforcement of the structure, we have been using a number of methods and injecting material. In this study, we compared and analyzed the amount of subsidence regarding the ground reinforcement during underground excavation in soft ground by performing model test. And three-dimensional numerical analysis was performed using FLAC 3D. The subsidence was simulated numerically according to the tunnel excavation. The subsidence results of the model tests and numerical analyzes were relatively consistent. Thus comparing the ground subsidence by varying the reinforcement area on the numerical analysis was analyzed. As a results, three-dimensional numerical simulation could be regarded to simulate better on the ground subsidence by various kinds of underground excavation and it can be used as a material of subsidence prevention methods.