• Title/Summary/Keyword: On line monitoring

Search Result 1,212, Processing Time 0.025 seconds

Operational Availability Improvement through Online Monitoring and Advice For Emergency Diesel Generator

  • Lee, Jong-Beom;Kim, han-Gon;Kim, Byong-Sub;M. Golay;C.W. Kang;Y. Sui
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.264-270
    • /
    • 1998
  • This research broadens the prime concern of nuclear power plant operations from safe performance to both economic and safe performance. First emergency diesel generator is identified as one of main contributors for the lost plant availability through the review of plants forced outage records. The framework of an integrated architecture for performing modern on-line condition for operational availability improvement is configured in this work. For the development of the comprehensive sensor networks for complex target systems, an integrated methodology incorporating a structural hierarchy, a functional hierarchy, and a fault-system matrix is formulated. The second part of our research is development of intelligent diagnosis and maintenance advisory system, which employs Bayesian Belief networks (BBNs) as a high level reasoning tool incorporating inherent uncertainty use in probabilistic inference. Our prototype diagnosis algorithms are represented explicitly through topological symbols and links between them in a causal direction. As new evidence from sensor network development is entered into the model especially, our advisory of system provides operational advice concerning both availability and safety, so that the operator is able to determine the likely modes, diagnose the system state, locate root causes, and take the most advantageous action. Thereby, this advice improves operational availability

  • PDF

Application & Development of a Monitoring & Analysis System for On-Line Power System Stability using GPS (GPS를 이용한 전력계통 온라인 안정성 감시,분석시스템 개발 및 실계통 적용)

  • Jeon, D.H.;Lee, J.U.;Choo, J.B.;Yoon, S.H.;Hwang, K.S.;Kang, M.J.;Lee, G.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.166-168
    • /
    • 2003
  • 전력계통의 안정운용을 위하여 대용량 발전소와 주요 345kV 전력소로부터 시각 동기화된 계통 운전자료를 온라인으로 취득하여 계통 안정성을 실시간으로 감시, 분석할 수 있는 전력계통 온라인 안정성 감시, 분석시스템을 개발하였다. 전력계통 온라인 안정성 감시, 분석시스템은 크게 Master 시스템과 Local 시스템으로 구성된다. Local 시스템은 시각동기 데이터 취득시스템(TSDS)이라고도 하는데, GPS를 이용한 시각 동기화된 계통 운전데이터를 측정하고, 지역사고 판단 및 사고데이터를 기록하며, 측정/기록데이터를 Master 시스템으로 온라인 전송해주는 역할을 한다. Master 시스템은 각 Local 시스템에서 전송되어진 측정/기록데이터를 수집하고, 광역사고 판단 및 사고데이터를 기록하며, 과도안정도를 온라인으로 평가해주는 역할은 한다. 현재 1단계 연구결과로서 울진, 영광, 고리 원자력발전소와 동서울,신제천,청양,아산,신옥천 전력소 등 총 8개소에 Local 시스템 설치 및 시운전이 완료되었고, 한국전력거래소(KPX)에 설치된 Master 시스템을 이용하여 TSDS의 확대적용을 위한 활용성 검증작업을 진행하고 있다.

  • PDF

Supervisory Protection System of Microgird Interconnected to Low Voltage Grids (저압계통 연계형 마이크로그리드의 보호감시 시스템)

  • Jyung, Tae-Young;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.36-42
    • /
    • 2011
  • This paper mainly proposes the protective coordination scheme of the microgrid system. The microgrid protection is identical to the conventional protection system separating the normal part and contingency part to reduce damage when the contingency occur at power cables, facilities. But they are different in the protection type. The conventional protection system only considers unidirectional current. However the microgrid protection should be considered not only unidirectional current but also backfeed current because various microsources and loads are installed in the microgrid system. In case the contingency occurs in microsource, when microgrid is interconnected to grid, the protection system should be configured to not separate microgrid from grid before the microsource is isolated to microgrid. And in case of fault occur in power system, the microsources should not isolated to microgrid before the static switch at PCC is tripped to separate from power system. Considering these characteristic of microgird, this paper proposes the protective coordination scheme of microgrid and implemented the on-line real time monitoring system. Especially in case the microgrid is connected to low voltage distribution system with 220/380V voltage level, the proposed protection method with power IT technology can solve the problems when the existing protective devices only applied to the microgrid system.

Stress and strain state in the segmental linings during mechanized tunnelling

  • Do, Ngoc-Anh;Oreste, Pierpaolo;Dias, Daniel;Antonello, Croce;Djeran-Maigre, Irini;Livio, Locatelli
    • Geomechanics and Engineering
    • /
    • v.7 no.1
    • /
    • pp.75-85
    • /
    • 2014
  • The application of the mechanized tunnelling has been extended in recent years. There are at present different approaches that are used in the design of segmental tunnel linings supported in mechanized tunnels. Even though segmental lining is utilized for mechanized tunnels, its behaviour is still quite unclear under in situ stress and there is a lack of data regarding the distribution of stresses inside segmental linings. So far no single effective calculation method exists for segmental lining design. The lack of clear solutions makes the use of segmental lining to be more expensive due to the adoption of greater safety factors. Therefore, a particular attention must be given in order to obtain data from monitored tunnels which permits to validate design methods. In this study, strain measurements, which were conducted during the construction of twin tunnels in the Bologna-Florence railway line, have been presented. The behaviour of segmental lining during the excavation and the influence of a new tunnel excavation on an existing tunnel have been shown through the measured data. The data are then compared with the results obtained with Einstein and Schwartz's method and Duddeck and Erdmann's method, which permits to highlight the fact that the two analytical methods underestimate structural forces induced in the segmental lining and then must be used with caution.

A Study on the ASK Communication Modem over Electrical Power Lines (전력선을 이용한 ASK통신 모뎀에 관한 연구)

  • 사공석진;송문규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.9
    • /
    • pp.951-962
    • /
    • 1992
  • The layout of electrical power distribution networks never involved communications aspects. As a result their transmission properties severly complicate the use as data links. Futhermore bandwidth as well as transmission power is restricted. Nevertheless, power distribution net works represent a most attractive medium for digital communication purposes due to an ever increasing demand, e.g., for environment management of buildings, office automation, and remote meter reading or security monitoring. In this paper, a power line modem which is capable of transmitting and receiving data at 1200 bps using OOK-BASK through 220V AC power lines is implemented. The receiver includes noncoherent detector and performs soft decision. The OLM circuits can be simplified by use of microprocessor. The PLM also satisfies CENELEC, European standards, and can be applied to home automation system.

  • PDF

Implementation of Zigbee/PLC Gateway System for U-Health Care (유비쿼터스 헬스케어를 위한 Zigbee/PLC 게이트웨이 시스템 구현)

  • Kim, Sung-Yun;Kang, Kyung-Il;Kweon, Min-Su;Rhee, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.3
    • /
    • pp.332-338
    • /
    • 2010
  • In this paper, Zigbee/PLC gateway system is designed for Ubiquitous health care. A protocol conversion algorithm for smooth information exchange between Zigbee and PLC communication has been implemented on the gatway. If a moving object is detected by wireless sensor, the data is transmitted to gateway. Zigbee/PLC gateway analyzes received data and transmits to Power Line Communication for real-time monitoring. Implemented system is can support elder who lives alone activity analysis, crime prevention system, Home network service.

A Study on the Network of Civilian, Enterprise, School and Government Sectors for Disaster Management (재난관리를 위한 민관산학네트워크 구축에 관한 연구)

  • Sung, Ki-Whan
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.4 s.72
    • /
    • pp.154-161
    • /
    • 2005
  • As disasters in the modem era become a large scale and complexity, no single entity can manage them. Instead collective cooperation between civilian, enterprise, school and government sectors is significantly needed, along with a well prepared mechanism. Thus, I attempt to construct the applicable network of civilian, enterprise, school and government sectors for disaster management through exemplary case studies of established countries as well as Korea's current operations and its drawbacks, based upon a networking design of disaster management organizations as belows: Firstly, it is cooperation and coordination among relevant organizations that are required essentially in the new era, in view of formative condition of necessary environment for civil participation. The cooperation and coordination can be made only through the network of civilian, enterprise, school and government sectors. Secondly, in order to build up the network, major roles and tasks which should be done by civilian, enterprise, school and government sectors respectively are listed based upon a stage of disaster management. Thirdly, operation models of a safety monitoring unit, a disaster prevention unit, a emergency response unit, and a rehabilitation unit are proposed in line with the network of civilian, enterprise, school and government sectors in regional base.

Implementation of the 155.52 MHz Clock Recovery Receiver for the Fiber Optic Modules (광통신 모듈용 155.52 MHz 클럭복원 리시버의 구현)

  • 이길재;채상훈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.12C
    • /
    • pp.249-254
    • /
    • 2001
  • A receiver ASIC for fiber optic modules of STM-1 optical communication has been fabricated with 0.65 $\mu\textrm{m}$ CMOS technology. The ASIC has a limit amplifier circuit for the 155.52 Mbps data reshaping, and a clock extraction circuit for the 155.52 MHz clock recovery. The ASIC has an acquisition aid and LOS monitoring circuit for properly operation with near 155.52 MHz clock frequency in case of the data loss due to transmission line open or data transfer fail. Measured results show that the circuit reshapes data from 5 mV to 1 V wide range of input voltage condition, add it recovers system clock with stable on any condition.

  • PDF

Development of the Chemical Flow Control System for Spinner Equipment in Semiconductor Manufacturing Process (반도체 제조공정의 스피너 장비를 위한 약액 흐름제어 시스템 개발)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1812-1816
    • /
    • 2011
  • This research developed chemical flow control system(CFCS) essential for spinner equipment in nano semiconductor manufacturing process under the 100nm to prevent complex process defect due to missing spread after chemical injection. The devices developed in this research, which can be swiftly replaced in case abnormal state element changes or wafer manufacturing defect occurs, are anticipated to improve module yield as well as real-time monitoring on the state element. In addition, as a result of mounting H/W and S/W system to control detailed operation sequence in production line and executing performance check and verification, we can be exactly detected in five abnomal process type.

Evaluation of Biological Activated Carbon Using Particle Counter (입자계수기를 이용한 생물활성탄 공정의 효율평가)

  • Kim, Hee gune;Ryon, Dong choon;Kim, Hyun sil;Ryu, Byung soon;Moon, Seong yong;Kim, Seung Hyun;Kim, Won Kyong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.823-828
    • /
    • 2006
  • For this study, an online particle counter was installed before and after the activated carbon filtration process of D water treatment plant where has advanced water treatment processes, produces average 900,000ton/day of drinking water and supply the produced drinking water to Busan citizens. We collected and analyzed particle count data for about 1 year. We inspected particle breakthrough in three out of sixteen filter processes operated at same conditions, i.e. 5th filter, 6th filter and 7th filter. According to the monitoring results, 6th and 7th filters showed similar results while 5th filter showed different results. When compared seasonal effect, the particle count for dry season was below 10 particles/ml while the particle count for August when monthly average rainfall is over 200mm was much higher than for dry season. In January and August, there was a difference in breakthrough particle size. In January, small particles in 2~3um were mainly detected while in August 10um particles were mainly detected and the size distribution was 40% of total count.