• 제목/요약/키워드: On Machine Measuring

검색결과 710건 처리시간 0.023초

3차원 좌표를 이용한 승용차 운전공간의 설계기법 개발 (A Development of an Occupant Packaging Tool Using 3-Dimensional Coordinates in Passenger Vehicle's Driver Space)

  • 정성재;박민용
    • 대한산업공학회지
    • /
    • 제26권3호
    • /
    • pp.257-264
    • /
    • 2000
  • This research suggested a method by which the driver space can be designed to best accommodate the driver's anthropometric characteristics. Three-dimensional manikins and a variable seating buck were developed and used for this study. Manikins were designed with 18 links comprising the 95th percentile male and 5th percentile female data. The seating buck was built to create various driving environments using the distance and the height between the H-point(hip pivot) of the seat and the AHP(accelerator heel point), the angle of the back rest, the angle of the steering wheel, the vertical distance of the steering wheel, and the location of the T.G.S.(transmission gear shift) knob. Measurements of each variable were collected with a coordinate measuring machine by positioning the 3-D manikin under various combinations of the design factors of the seating buck, which was constructed based on mid-size domestic passenger cars. The data were then converted to the joint angles of the driver. The combination of the measurements for an optimal driving environment is suggested by applying sets of the joint angles at which the driver feels comfortable.

  • PDF

순시무효전력을 이용한 영구자석 동기전동기의 새로운 센서리스 제어 (New Sensorless Control Strategy for a Permanent Magnet Synchronous Motor based on an Instantaneous Reactive Power)

  • 최양광;김영석;한윤석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권4호
    • /
    • pp.247-254
    • /
    • 2004
  • The mechanical informations such as the rotor speed and angle are required to operate the Cylindrical Permanent Magnet Synchronous Motor(PMSM). A resolver or encoder is typically used to supply the mechanical informations. This position sensor adds length to the machine, raises system cost, increases rotor inertia and requires additional devices. As the result, there has been a significant interest in the development of sensorless strategies to eliminate the position sensor. This paper presents an implementation of the new sensorless speed comtrol scheme for a PMSM. In the proposed algorithm, the line currents are estimated by a observer and the estimated speed can be yielded from the voltage equation because the information of speed is included in back emf. But the speed estimation error between the estimated and the real speeds is occured by errors due to measuring the motor parameters and sensing the line current and the input voltage. To minimize the speed estimations error, the estimated speeds are compensated by using an instantaneous reactive power in synchronously rotating reference frame. In this paper, the proposed algorithm is not affected by mechanical motor parameters because the mechanical equation is not used. The effectiveness of algorithm is confirmed by the experiments.

고령자 ADL 개선을 위한 기능적 운동 분석 및 선정 (Analysis of Functional Status and Determination for Improvement of ADLs: Korean Elderly)

  • 김사엽;박성빈;형준호;정경렬
    • 대한인간공학회지
    • /
    • 제29권6호
    • /
    • pp.915-924
    • /
    • 2010
  • Muscular strength in the elderly is important factors deciding on functional state in daily lives, and functional state shows a health condition. Resistance training to prevent loss of muscle mass and muscle fiber atrophy due to aging can increase muscle mass and strength. Recently, resistance training to improve muscular strength and endurance has been actively researched. Resistance training increases activities of daily living and ability of the elderly, which makes healthy senescent. ADL/IADL is suitable for measuring health condition of the elderly. In this study, target muscles of resistance training were chosen through a correlation analysis between ADLs and elementary motion, and we presented a procedure to select target muscles and exercise equipments. This procedure consist of a survey method that were described detailed motion of ADL/IADL. So we should be to extract resistance training machine to improve functions of regarding fundamental motion. Result of study may improve daily life activities of the elderly through objectives and scientific approaches. Furthermore, it will be helpful to studies about various fields of the elderly.

IEEE-1394카메라와 스텝모터를 이용한 엔진 실린더헤드의 흡기포트 스월 측정 자동화에 관한 연구 (A Study on the Automatic Measurement of Swirl Generated fi:om Intake Port of Engine Cylinder Head Using an I-IEEE-1394 Camera and Step Motors)

  • 이충훈
    • 한국공작기계학회논문집
    • /
    • 제14권6호
    • /
    • pp.88-94
    • /
    • 2005
  • A swirl ratio of a charge in the cylinder could be calculated by measuring both the rotary speed of paddle and the intake air flow rate in the swirl measurement apparatus fur several positions of valve lift. The automation of the swirl ratio measurement for a cylinder head is achieved by controlling both the valve lift of cylinder head and a suction pressure of the surge tank, instead of controlling them manually. PID control of the surge tank pressure and positioning a valve lift of the cylinder head are also achieved by using two step motors, respectively. Rotating speed of a paddle are measured using an optical sensor and a counter. Flow rate are measured from ISA 1932 flow nozzle by reading a differential pressure gauge position using IEEE-1394 camera. Time to measure the swirl ratio for a port in the cylinder head is drastically reduced from an hour to 3 minutes by automation control of the apparatus.

초미립 WC 소재 엔드밀 공구의 성능 평가에 관한 연구 (A Study on the Performance Evaluation of End Mill Tool Fabricated by Ultra-Fine WC)

  • 김도형;우용원;이현호;김정석
    • 한국공작기계학회논문집
    • /
    • 제16권6호
    • /
    • pp.1-8
    • /
    • 2007
  • The ultra-fine tungsten carbide(WC) powders have been actively used in the cemented carbides industry, because they have excellent mechanical properties such as high hardness, strength, and toughness. In this study, ultra-fine WC-Co alloys powders have been fabricated by thermochemical and thermomechanical process such as spray conversion process or high energy ball milling. The non-coated end-mill which is made of ultra-fine tungsten carbide is investigated by measuring cutting force, tool wear, tool life, and surface roughness profile according to cutting length. The machining test was conducted with high hardened workpiece and their performances are investigated in high speed cutting conditions. Also, the relationship between the machining characteristics and the Co contents are investigated under various high speed cutting conditions.

구동 시스템 시험을 위한 고성능 다이나모메터 제어 (A Highly Efficient Dynamometer Control For Motor Drive Systems Testing)

  • 김길동;신정렬;이한민;이우동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1291-1293
    • /
    • 2004
  • The control method of programmable dynamometer for overall test of machine is to load the reference torque which is computed from torque transducer into motor under test. But the torque information detected from torque transducer have a lot of noise when the load torque of meter is a small quantity or changing. Thus, torque transducer must have a low pass filter to detect a definite torque information. But The torque delay generated by filter with torque transducer occur a torque trouble for moter torque of programmable dynamometer. Therefore, this kind of system could not perform dynamic and nonlinear load. In this paper, the control method using the load torque observer without a measure for torque transducer is proposed. The proposed system improved the problem of the torque measuring delay with torque transducer, and the load torque is estimated by the minimal order state observer based on the torque component of the vector control induction meter. Therefore, the torque controller is not affected by a load torque disturbance.

  • PDF

ZCT틀 이용한 피뢰기 열화 감시 시스템 개발 (Development of Lightning Arrester Degradation Monitoring System Using ZCT)

  • 박정남;이용희;장수형;김필석;신양섭;김영근;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1626-1628
    • /
    • 2003
  • The lightning arrester is a very important overvoltage protection device in the electric power system. Therefore, the inspection of lightning arrester whether it keeps its performance or not properly has close related to verifying the safety confidence of the electric power system. But the development of the deterioration measuring method and on-line detecting system, is necessary to monitor the deterioration of the lightening arrestor. In this paper, we developed the lightning arrester degradation monitoring system. This system detected leakage current of lightning arrester by using the ZCT, and analyze the third harmonics ingredient of leakage current using DFT method in the Data Acquisition Unit(DAU). The analyzed current signal is transmit to the Human-Machine Interface(HMI), and HMI alarmed when accident are occurred and informed with the amplitude of leakage current to the operator.

  • PDF

국내생산차량의 시트 머리구속장치 평가에 관한 연구 (A Study on the Evaluation of Head Restraint System in Domestic Cars)

  • 조휘창;박인송;김영은
    • 한국자동차공학회논문집
    • /
    • 제12권1호
    • /
    • pp.99-105
    • /
    • 2004
  • The car seat head restraint is used for neck injury(whiplash injury) prevention in rear end impacts. The purpose of this study was to evaluate the seat head restraints for the total number of 34 domestic cars. H-POINT machine and HRMD(head restraint measuring device) were applied to measure backset(the distance between head and seat head restraint) and height(height gap between head and seat head restraint). For tendency study of driver's head position, we took the 320 driver's pictures in the street. As results, There were only five percent drivers in good and acceptable zone. For car seat head restraint system, the results was 9 cars for good zone, 10 cars for acceptable zone, 9 cars for marginal zone and 6 cars for poor zone were evaluated. For a precise evaluation the of whiplash injury, detailed FE neck model will be developed and the clinical database should be constructed for model validation.

사출성형공정 모니터링용 엣지 디바이스 개발 및 평가 (Development and evaluation of edge devices for injection molding monitoring)

  • 김종선;이준한
    • Design & Manufacturing
    • /
    • 제14권4호
    • /
    • pp.25-39
    • /
    • 2020
  • In this study, an edge device that monitors the injection molding process by measuring the mold vibration(acceleration) signal and the mold surface temperature was developed and evaluated its performance. During injection molding, signals of the injection start, V/P switchover, and packing end sections were obtained through the measurement of the mold vibration and the injection time and packing time were calculated by using the difference between the times of the sections. Then, the mold closed and mold open signals were obtained using a magnetic hall sensor, and cycle time was calculated by using the time difference between the mold closed time each process. As a result of evaluating the performance by comparing the process data monitored by the edge device with the shot data recorded on the injection molding machine, the cycle time, injection time, and packing time showed very small error of 0.70±0.38%, 1.40±1.17%, and 0.69±0.82%, respectively, and the values close to the actual were monitored and the accuracy and reliability of the edge device were confirmed. In addition, it was confirmed that the mold surface temperature measured by the edge device was similar to the actual mold surface temperature.

유방엑스선검사 시 유방, 갑상샘, 안구 피폭선량 감소를 위한 차폐체 비교 (Comparison of Shield of Breast, Thyroid, Eyes for Exposure Dose Reduction in Mammography)

  • 안세정;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.189-194
    • /
    • 2021
  • This study was conducted to reduce the exposure dose to the breast and adjacent organs as the number of Mammography increased. Therefore, it has been designed a shield in lead, bismuth + tungsten, and bismuth that does not require to be equipped by the patient, in which each type of shield was compared and analyzed of radiation exposure dose to breast, thyroid, and eye. Using a mammography machine, optically stimulated luminescent dosimeter(OSLD) was inserted to bilateral breast, thyroid, and eye of a dosimetry phantom to measure dose radiated onto the phantom. Shielding device was made in different thickness of 2mm, 3mm, and 5mm and dose evaluation was performed by measuring the dose while using lead, bismuth, and bismuth + tungsten prosthesis. When each shields combined with shielding device, were compared of dose, all showed similar does reduction in the dose to breast, thyroid, and eye in both cranialcaudal and mediolateraloblique view. Based on the current study, bismuth and bismuth + tungsten can replace conventional lead shield and it is anticipated to safely and conveniently reduce radiation exposure to breast, thyroid, and eye with the shield that does not require to be equipped.