• 제목/요약/키워드: On/Off valve

Search Result 253, Processing Time 0.029 seconds

Study on Leakage Analyses and Experimets on a Main Oxidizer shut-off Valve (산화제 개폐밸브 플랜지 기밀 해석 및 시험에 관한 연구)

  • Yoo, Jae-Han;Hong, Moon-Geun;Bae, Young-Woo;Lee, Soo-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.251-253
    • /
    • 2010
  • In the leakage test of a Main Oxidizer shut-off valve, gas leakage was found on the middle flange with a metal conical seal. The structural analysis was performed for three models with different numbers of bolts and flange shapes and then one model was selected in consideration of the minimum axial gap deformation as well as the weight increment due to the change of flange shapes. Experimental leakage tests for the simulated flanges of the selected model has resulted in no gas leakage, and consequently the structural analysis method for the design of the middle flanges has proved feasible.

  • PDF

A Study on the Development of Low Power Automatic ON/OFF Valve System for Gas Leak Detection (가스 누출 감지를 위한 저전력 자동 ON/OFF 밸브 시스템 개발에 관한 연구)

  • Choi, Young Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.369-374
    • /
    • 2021
  • Apartment recently built in kitchen is made is made because the gas hose with built-in ways invisible inside the sink. In this case, if the gas leaks, it is a dangerous method that can accumulate inside the sink and lead to an explosion. In this study, since the hose connected between the gas range and the intermediate valve is inside the sink, it is not possible to test for gas leaks, so a valve system that can easily check for gas leaks using a pressure sensor was studied. As for the pressure measurement method, the pressure of the hose connecting the intermediate valve and the gas range was measured so that data could be collected and analyzed using the I2C communication method. In addition, the calculation of the gas pressure supplied to the home was investigated for the atmospheric pressure error for the value calculated by adding the average value of the gas gauge pressure of 22.46 mbar at the inlet of the gas meter to the atmospheric pressure. A valve system was developed to detect minute gas leaks.

A Study on the Tuning Parameter of Continuous Variable Valve for Reverse Continuous Damper (리버스 무단 댐퍼용 연속가변밸브의 튜닝 파라미터에 관한 연구)

  • 윤영환;최명진;유송민
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.192-200
    • /
    • 2002
  • Semi-active suspension systems are greatly expected to be in the mainstream of future controlled suspensions for passenger cars. In this study, a continuous variable damper for a passenger car suspension is developed, which is controlled actively and exhibits high performance with light weight, low cost, and low energy consumption. To get fast response of the damper, reverse damping mechanism is adapted, and to get small pressure change rate after blow-off, a pilot controlled proportional valve is designed and analyzed. The reverse continuous variable damper is designed as a HS-SH damper that offers good body control with reduced transferred input force from tire, compared with any other type of suspension system. The damper structure is designed, so that rebound and compression damping force can be tuned independently, of which variable valve is placed externally. The rate of pressure change with respect to the flow rate after blow-off becomes smooth when the fixed orifice size increases, which means that the blow-off slope is controllable using the fixed orifice size. The damping force variance is wide and continuous, and is controlled by the spool opening, of which scheme is usually adapted in proportional valves. The reverse continuous variable damper developed in this study is expected to be utilized in the semi-active suspension systems in passenger cars after its performance and simplicity of the design is confirmed through real car test.

Optimal Tricuspid Annular Size for Tricuspid Annuloplasty in Patients with Less-Than-Moderate Functional Tricuspid Regurgitation

  • Choi, Jae Woong;Kim, Kyung Hwan;Lim, Su Chan;Kim, Sue Hyun;Sohn, Suk Ho;Lee, Yeiwon;Hwang, Ho Young
    • Journal of Chest Surgery
    • /
    • v.53 no.6
    • /
    • pp.325-331
    • /
    • 2020
  • Background: We evaluated the association between tricuspid annular dilatation and the development of moderate or severe tricuspid regurgitation (TR). Additionally, we determined the optimal tricuspid annular dilatation threshold to use as an indicator for tricuspid annuloplasty in patients with less-than-moderate functional TR (FTR). Methods: Between August 2007 and December 2014, 227 patients with less-than-moderate TR underwent mitral valve surgery without a tricuspid valve (TV) procedure. The TV annular diameter was measured via transthoracic echocardiography. The TV annular index (TVAI) was calculated as the TV annular diameter divided by the body surface area. The mean duration of echocardiographic follow-up was 42.0 months (interquartile range, 9.3-66.6 months). Results: Eight patients (3.5%) developed moderate or severe TR. The rate of freedom from development of moderate or severe TR at 5 years was 96.2%. TV annular diameter, left atrial diameter, preoperative atrial fibrillation, and TVAI were found to be associated with the development of moderate or severe TR in the univariate analysis. A cut-off TVAI value of 19.8 mm/㎡ was found to predict the development of moderate or severe TR, and a significant difference was observed in the development of TR of this severity based on this cut-off (p<0.001). Conclusion: The progression of TR was not infrequent in patients with untreated lessthan-moderate FTR. An aggressive treatment approach can be helpful to prevent the progression of FTR for patients with risk factors, especially TVAI greater than 19.8 mm/㎡.

Operating Performance of Solenoid Valve and Nozzle Sets for Target Selectable Sprayers (이동형 국소 분무장치용 전자 밸브와 노즐 조합 작동특성)

  • Suh, S.R.;Kim, H.O.;Kim, Y.T.;Choi, Y.S.;Yoo, S.N.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.1 s.114
    • /
    • pp.39-45
    • /
    • 2006
  • Fundamental informations on performance of sets of solenoid valve and nozzle were necessary to develop a target selectable spraying system. The experiments were performed for the sets of solenoid valves and flat spraying nozzles at 3 levels of the operating pressures, and the obtained results are as follows; Rise time of the system pressure to reach up to 90% of the operating pressure after the valve turned was affected by nozzle size and operating pressure. Maximum overshoot of the system pressure was about 170% not affected by the sets of valve and nozzle and operating pressure. The system pressure after its settle down within 5% of the set pressure showed good uniformity in any condition of the experiment as less as 2.3% of its coefficient of variation. Time requirement to lower the system pressure down to 50% after the valve power turned off was affected by valve and nozzle set and operating pressure.

Injection volume control of carboxy-gun using a solenoid valve (솔레노이드 밸브를 이용한 카복시 건의 주입량 제어)

  • Tak, Tae-Oh;Han, Nam-Gyu;Shin, Young-Kyu
    • Journal of Industrial Technology
    • /
    • v.32 no.A
    • /
    • pp.65-70
    • /
    • 2012
  • Carboxy-guns are used for rapid and precise injection of $CO_2$ gas to the target skin area using external power source. In the design of carboxy-gun, the most important thing is how to precisely control injection volume of $CO_2$ gas. This paper deals with the control scheme of injection volume of carboxy-gun using solenoid valve. First the amount of volume that passes through the solenoid valve under on-off time ratio control is estimated based on the assumption of compressible gas flow. The flow rate of gas is experimentally measured under the varying pressure of the gas reservoir. Two results showed good correlation to each other, thus demonstrating the validity of the volume control strategy.

  • PDF

위성 추진시스템의 추력제어밸브 작동에 따른 추진제 비정상 유동 특성

  • Kim, Jeong-Soo;Han, Cho-Young;Lee, Kyun-Ho
    • Aerospace Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.51-56
    • /
    • 2002
  • Satellite propulsion system is employed for orbit transfer, orbit correction, and attitude control. The monopropellant feeding system in the low-earth-orbit satellite blowdowns fuel to the thrust chamber. The thrust produced by the thruster depends on fuel amount flowed into the combustion chamber. If the thruster valve be given on-off signal from on-board commander in the satellite, valve will be opened or closed. When the thrusters fire fuel flows through opened thruster valve, instantaneous stoppage of flow in according to valve actuation produces transient pressure due to pressure wave. This paper describes transient pressure predictions of the KOMPSAT-2 propulsion system resulting from latching valve and thrust control valve operations. The time-dependent set of the fluid mass and momentum equations are calculated by MOC.

  • PDF

Intelligent Switching Control of Pneumatic Cylinders by Learning Vector Quantization Neural Network

  • Ahn KyoungKwan;Lee ByungRyong
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.529-539
    • /
    • 2005
  • The development of a fast, accurate, and inexpensive position-controlled pneumatic actuator that may be applied to various practical positioning applications with various external loads is described in this paper. A novel modified pulse-width modulation (MPWM) valve pulsing algorithm allows on/off solenoid valves to be used in place of costly servo valves. A comparison between the system response of the standard PWM technique and that of the modified PWM technique shows that the performance of the proposed technique was significantly increased. A state-feedback controller with position, velocity and acceleration feedback was successfully implemented as a continuous controller. A switching algorithm for control parameters using a learning vector quantization neural network (LVQNN) has newly proposed, which classifies the external load of the pneumatic actuator. The effectiveness of this proposed control algorithm with smooth switching control has been demonstrated through experiments with various external loads.

High accuracy position control of pneumatic rodless cylinder using LVQNN (LVQNN을 이용한 공압 로드리스 실린더의 고정도 위치제어)

  • 표성만;정민화;안경관;이병룡;양순용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1012-1017
    • /
    • 2003
  • The development of a fast, accurate, and inexpensive position-controlled pneumatic actuator that may be applied to a variety of practical positioning applications with various external loads is described in this paper. A novel modified pulso width modulation (MPWM) valve pulsing algorithm allows on/off solenoid valves to be used in place of costly servo valves. A comparison between the system response of standard PWM technique and that of the novel modified PWM technique shows that the control performance is significantly increased. A state feedback controller with position, velocity and acceleration feedback is successfully implemented as the continuous controller. Switching algorithm of control parameter using learning vector quantization neural network (LVQNN) is newly proposed. which estimates the external loads of the pneumatic actuator. The effectiveness of the proposed control algorithms are demonstrated through experiments with various loads.

  • PDF