• Title/Summary/Keyword: On/Off valve

Search Result 253, Processing Time 0.025 seconds

Analysis of the Working Conditions of Fire Protection Systems in the Goyang Bus Terminal Building Fire (고양종합터미널화재 시 소방시설의 작동실태 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.95-107
    • /
    • 2018
  • This study analyzed the working conditions of the fire protection system in the Goyang Bus Terminal fire based on the fire investigation results. The results were as follows. First, extinguishing using an indoor fire hydrant was not attempted immediately after the fire burned the ceiling urethane foam. Second, a sprinkler alarm valve was turn off and did not work in the repair work space of the 1st basement. On the other hand, the sprinklers in the $2^{nd}$ basement, $1^{st}$ floor, $2^{nd}$ floor, and $3^{rd}$ floor worked and prevented the fire from moving to stories other than the $1^{st}$ basement. Third, although an exit light worked normally, it was not installed in the exit from the waiting room in the $2^{nd}$ floor to the bus stop. This resulted in many casualties. Fourth, although a fire receiver sent an electrical signal to the fan controller of the smoke control system, it was treated manually in the fan controller and the fan in the $2^{nd}$ floor did not work.

Virtual Home Training - Virtual Reality Small Scale Rehabilitation System (가상 홈 트레이닝 - 가상현실 기반 소근육 재활 시스템)

  • Yu, Gyeongho;Kim, Hae-Ji;Kim, Han-Seob;Lee, Jieun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.24 no.3
    • /
    • pp.93-100
    • /
    • 2018
  • This paper proposes a small-scale rehabilitation system that allows stroke patients to perform daily rehabilitation training in a virtual home. Stroke patients have limited activities of daily living due to paralysis, and there are many rehabilitation exercises for them to reproduce activities that take place in the house, such as turning lights on and off, door opening and closing, gas valve locking. In this paper, we have implemented a virtual home with the above mentioned daily rehabilitation training elements, by using virtual reality technology. We use Leap Motion, a hand motion recognition device, for rehabilitation of hands and fingers. It is expected that stroke patients can rehabilitate small muscles without having to visit the clinic with uncomfortable body, and will be able to get interesting rehabilitation training by avoiding monotony of existing rehabilitation tools.

Study on Adiabatic Performance of LNG Storage Tank for Vehicles (차량용 LNG연료용기의 단열성능에 관한 연구)

  • Han, Jeong-Ok;Lee, Young-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.31-35
    • /
    • 2008
  • Natural gas vehicles are being applied to city buses for improving air quality in metropolitan and have proved the effective way to reduce the pollutant emissions. Liquified Natural Gas(LNG) has also attempted a vehicle fuel in order to raise the fuel storage density that is a disadvantage of Compressed Natural Gas(CNG). This paper described insulation characteristic of a LNG storage tank. From the results, adiabatic coefficient of a tested tank was around $40J/h{\cdot}^{\circ}C{\cdot}m^2$ and it was the lower level than gas safety regulation limit. Two experimental methods were adopted to justify the evaluation results and they were revealed that the results were very similar to each other. Also, through testing relief valve operation characteristic it was investigated venting amount of boiled off gas.

  • PDF

Operational Characteristics of the High-speed Interrupter for Reliability Enhancement of Power Supply and Demand (전력수급의 신뢰도 확보를 위한 고속 인터럽터 동작 특성)

  • Choi, Hye-Won;Choi, Hyo-Sang;Jung, Byung-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.143-148
    • /
    • 2013
  • When the fault occurs in power system, the fault-current exceeds breaking capacity of the circuit breaker. So, reliablity of the power system is decreased sharply. Superconducting fault-current limiter (SFCL) is operated without impedance in normal state. The fault-current is limited by its impedance during the fault condition. However, the SFCL has several weak points such as huge size, high-price, liquid-nitrogen operation for the real power system. In this paper, We suggested the high-speed interrupter to limit the fault-current in case of the single line-to-ground fault. In addition, we compared the high-speed interrupter with the SFCL to ensure the operation reliability. The proposed interrupter detected the fault-current through the CT, and the power was supplied by operation of the SCR control system. In this experiment, the power of high-speed interrupter was applied after the 4.8[msec] from fault instant. The on-off operation of the interrupter was started after half-cycle from the fault. The fault-current was flowed into the impedance element by the switching operation of the high-speed interrupter. So, the fault current was limited within one cycle, and then it didnt exceed the capacity of a circuit breaker. We confirmed that there was slight difference between the SFCL with high-speed interrupter in terms of limiting-time of the fault-current and switching speed of the SCR. The high-speed interrupter was considered to be more efficient than the SFCL in size, cost or reliability.

Computed Tomography-Based Ventricular Volumes and Morphometric Parameters for Deciding the Treatment Strategy in Children with a Hypoplastic Left Ventricle: Preliminary Results

  • Goo, Hyun Woo;Park, Sang-Hyub
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1042-1052
    • /
    • 2018
  • Objective: To determine the utility of computed tomography (CT) ventricular volumes and morphometric parameters for deciding the treatment strategy in children with a hypoplastic left ventricle (LV). Materials and Methods: Ninety-four consecutive children were included in this study and divided into small LV single ventricle repair (SVR) (n = 28), small LV biventricular repair (BVR) (n = 6), disease-matched control (n = 19), and control (n = 41) groups. The CT-based indexed LV volumes, LV-to-right-ventricular (LV/RV) volume ratio, left-to-right atrioventricular valve (AVV) area ratio, left-to-right AVV diameter ratio, and LV/RV long dimension ratio were compared between groups. Proportions of preferred SVR in the small LV SVR group suggested by the parameters were evaluated. Results: Indexed LV end-systolic (ES) and end-diastolic (ED) volumes in the small LV SVR group ($6.3{\pm}4.0mL/m^2$ and $14.4{\pm}10.2mL/m^2$, respectively) were significantly smaller than those in the disease-matched control group ($16.0{\pm}4.7mL/m^2$ and $37.7{\pm}12.0mL/m^2$, respectively; p < 0.001) and the control group ($16.0{\pm}5.5mL/m^2$ and $46.3{\pm}10.8mL/m^2$, respectively; p < 0.001). These volumes were $8.3{\pm}2.4mL/m^2$ and $21.4{\pm}5.3mL/m^2$, respectively, in the small LV BVR group. ES and ED indexed LV volumes of < $7mL/m^2$ and < $17mL/m^2$, LV/RV volume ratios of < 0.22 and < 0.25, AVV area ratios of < 0.33 and < 0.24, and AVV diameter ratios of < 0.52 and < 0.46, respectively, enabled the differentiation of a subset of patients in the small LV SVR group from those in the two control groups. One patient in the small LV biventricular group died after BVR, indicating that this patient might not have been a good candidate based on the suggested cut-off values. Conclusion: CT-based ventricular volumes and morphometric parameters can suggest cut-off values for SVR in children with a hypoplastic LV.

Long-term Influence of Mild to Moderate Ischemic Mitral Regurgitation after Off-pump Coronary Artery Bypass Surgery (무심폐기하 관상동맥우회술에서의 중등도의 허혈성 승모판막부전증의 중요성)

  • Hong, Jong-Myeon;Cartier, Raymond
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.246-253
    • /
    • 2010
  • Background: Our objective was to review the long-term prognosis of patients with preoperative mild to moderate ischemic mitral regurgitation who underwent off-pump coronary artery bypass grafting. Material and Method: We prospectively followed 1,000 consecutive and systematic off-pump coronary artery bypass grafting patients who were operated on between September 1996 and March 2004; follow-up was achieved for 97%. Sixty-seven patients (6.7%) had mild to moderate ischemic mitral regurgitation at the time of surgery. Operative mortality, actuarial survival and major adverse cardiac event free survival were compared to assess the effect of ischemic mitral regurgitation. Result: Average follow-up was $66{\pm}22$ months. Patients with ischemic mitral regurgitation were older (p<0.001), had lower ejection fractions (p<0.001) and more comorbidities. Significantly more female patients presented with ischemic mitral regurgitation (p=0.002). There was no significant difference in operative mortality and perioperative myocardial infarction in ischemic mitral regurgitation patients (p=0.25). Eight-year survival was decreased in ischemic mitral regurgitation patients ($39.6{\pm}11.8%$ vs $76.7{\pm}2.2$, p<0.001). However, after correcting for risk factors, mild to moderate ischemic mitral regurgitation was not found to be a significant independent risk factor for long-term mortality (p=0.42). Major adverse cardiac event free survival at 8 years was significantly lower in ischemic mitral regurgitation patients ($53.12{\pm}12%$ vs $77{\pm}2%$, p<0.001). After correction for risk factors, ischemic mitral regurgitation remained a significant independent cause of major adverse cardiac events (HR: 2.31), especially congestive heart failure and recurrent myocardial infarction. Conclusion: In our series, patients with preoperative mild to moderate ischemic mitral regurgitation had a higher prevalence of preoperative risk factors than patients without ischemic mitral regurgitation. They had comparable perioperative mortality and morbidity, but, in the long term, were found to be at elevated risk for recurrent cardiac events.

Giant Magnetoresistance of Antiferromagnetic Cr-Al based Multilayer Spin-Valve with Anti-Corrosion and Thermal Stability (내열 내식용 Cr-Al반강자성계 스핀밸브막의 거대자기저항 효과)

  • 김병수;이성훈;이찬규
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.6
    • /
    • pp.362-368
    • /
    • 1998
  • The magnetic properties, thermal stability and anti-corrosion properties of $Cr_86Al_14$ spin valves multilayers were studied. It was found that the magnetic properties of $Cr_86Al_14$ spin valves depend on the thickness of antiferromagnetic, ferromagnetic and non-ferromagnetic layers. Exchange coupled field ($H_{ex}$) and magnetoresistance ratio (%) showed the largest value of 20 Oe, 2 % in $glass/Cr_{86}Al_{14}(600 $\AA$)/Ni_{81}Fe_{19}(50$\AA$)/Cu(40 $\AA$)/Ni_{81}Fe_{19}(40 $\AA$)$ spin valves. The $H_{ex}$ MR ratios (%) of CrAl and FeMn spin valves were decreased with increasing annealing temperatures and were lost at 150 $^{\circ}C$, 250 $^{\circ}C$ respectively. Based on these result, it was elucidated that CrAl is more thermally stable than FeMn. It was also shown that there was no change of $H_{ex}$ MR ratios in CrAl, while FeMn was changed and lost 15 days later in corrosion resistance test under 35 $^{\circ}C$, 90 % humidity condition. FeMn was found to be pitted and peeled off 15 days later by SEM micrographic analysis.

  • PDF

Fire-fighting Pump Approval Standard for Fire-fighting Trucks with an Additional Positive Displacement Pump (용적형 펌프를 추가한 소방자동차용 소방펌프의 성능 인정기준에 관한 연구)

  • Han, Yong-Taek;Sung, Ki-Chan;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.104-110
    • /
    • 2016
  • Positive displacement pumps with high pressure and water capacity are used large fires in various high-rise buildings. This study provides information for a performance approval standard of fire pumps for fire trucks based on centrifugal pump standards enacted in 2012. An experiment was conducted with a positive displacement pump for three levels of performance from the approval standard (V-1, 2, and 3). The efficiency of the pump was included in the reference, which requires the approval of 65% performance, the same as a centrifugal pump. The water pressure is between 1.5 and 2.5 MPa, and the required flow rate was established as at least $0.31m^3/min$ and up to $3.0m^3/min$. A relief valve was added to adjust the shut-off pressure due to the structural characteristics of the positive displacement pump. A strainer was also installed to prevent damage to the inside of the pump due to foreign matter. However, the strainer includes a difference from the positive displacement pump to operate without a vacuum pump and the centrifugal pump. This is due to the additional approval standard portion of the positive displacement pump, which is expected to be selected for more variety of fire-fighting equipment and proactive responses to fire suppression in a high-rise buildings and large fires. In conclusion, this approval standard was enacted in January 2016.

Development of an Automated Measurement System for Dilution Process and Spraying Amount of Disinfectant

  • Kim, Jung-Chul;Chung, Sun-Ok;Cho, Byoung-Kwan;Chang, Hong-Hee;Kim, Suk;Chang, Dongil
    • Journal of Biosystems Engineering
    • /
    • v.38 no.4
    • /
    • pp.228-239
    • /
    • 2013
  • Purpose: The objectives of this study were to develop an automated disinfectant dilution system, and an automated data management system for spraying amount for resolving uncertainty problem. Methods: Proper diluting rate was made by a controlled volume pump for liquid disinfectant and a screw conveyer pump for solid disinfectant. The water capacity of disinfecting system of 400 L was controlled by two water level sensors. The water quantity of water tank was controlled by the signals which were produced by the water level sensors. Signals were processed by Labview Programming, and ON/OFF of solenoid valve that was used for controlling water supplying to water tank, was controlled by SSR. The operating time of pumps for disinfectant was controlled quantitatively. A turbine flowmeter was used for development of automated measurement system for spraying amount of disinfectant. In order to save the flowmeter data and to control the spraying system, a multi-function data logger was used, and it was processed and saved in Excel file by a program developed in this study. Results: Labview 2010 was used for programming to control the automated measurement system for spraying amount of disinfectant. Results showed that the relationship between flowmeter value and time had a significant linear relationship such as 0.99 of $R^2$. Generally, 6.74 L/s of diluted disinfectant is sprayed for a vehicle passing through the disinfection system (about 15 seconds). Test results showed that average error between the measured spraying amount and the flowmeter data was 50 mL, and the range of error was 1.3%. Since the amount and time of spraying could be saved in real-time by using the spreadsheet files which could not be modified arbitrarily, it made possible to judge objectively whether the disinfection spraying was performed or not. Test results of spraying liquid and solid disinfectant showed that the errors between the measured discharge rate and the theoretical one were ranged within 3-4% for various dilution rates. Conclusions: The disinfection system developed would be working accurately. The automated spraying data base management system satisfied the purpose of this study. The automated dilution process system developed in this study could discharge liquid and solid disinfectant with accurate dilution rate, relatively.

Clinical Experiences of redo-CABG (관상동맥우회 재수술의 임상적 고찰)

  • Lim, Sang-Hyun;Kwak, Young-Tae;Lee, Sak;Chang, Byung-Chul;Kang, Meyun-Shick;Cho, Bum-Koo;Yoo, Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.35 no.11
    • /
    • pp.779-784
    • /
    • 2002
  • Recently, the number of coronary artery bypass surgery(CABG) is increasing according to the increasing incidence of coronary artery disease. However, CABG is not a definite corrective surgery; therefore, in some patients, redo-CABG may be required. We retrospectively reviewed our redo-CABG experiences to help future redo-CABG. Material and Method: From January 1991 to April 2001, 14 cases of redo-CABG were performed in Yonsei Cardiovascular Center(M:F=12:2) and mean age was 61,7 $\pm$ 7.1(47-72) years. Mean time from 1st. CABG to redo-CABG was 121.9 $\pm$ 50.5(6.1-179.6) months. Thirteen cases were conventional on-pump CABG and one case was off-pump CABG. In two patients, mitral valve re-replacement and mitral valve repair were performed each. All redo-CABG were performed through mid-sternotomy. During redo-CABG, left internal mammary artery and saphenous vein grafts were used in 6 patients, left internal mammary artery and left radial artery grafts were used in 2 patients, left internal mammary artery and gastroepiploic artery were used in one patient and only greater saphenous veins were used in 5 cases(In one case, cephalic vein was also used). The number of mean distal anastomosis was 2.1 $\pm$ 0.9(1-4). Result: There were no operative death and no perioperative myocardial infarctions and cerebrovascular accidents or other heart related complications. Mean follow up duration was 40.1 $\pm$ 38.6(1.1-118.5) months. During follow up period, angina was re-developed in one patient 13 months after operation. Two patients died of end-stage renal failure 14.8 months and 116.3 months after redo-CABG, respectively. During follow up period, coronary angiography was performed in 3 patients, and all grafts were patent. At last follow up, mean Canadian class was 1.3. Kaplan-Meier survival at 9 years was 90.0 $\pm$ 9.5% and event free survival at 9 years was 71.4 $\pm$ 6.9%. Conclusion: After redo-CABG, all patients improved their angina symptom and daily activity. And long-term survival after redo-CABG was excellent. Therefore, if patients have indications for redo-CABG, thenredo-CABG must be strongly recommended and performed.