• 제목/요약/키워드: On/Off valve

검색결과 252건 처리시간 0.018초

고속전자밸브를 사용한 유압장치의 PWM 제어에 관한 연구 (A Study on the PWM Control of Hydraulic Equipment Using High Speed On-Off Valve)

  • 허준영
    • 대한기계학회논문집
    • /
    • 제19권3호
    • /
    • pp.868-876
    • /
    • 1995
  • This study deals with a position control of an electro-hydraulic servo system which consist of cylinder and high speed on-off valves operated by microcomputer. The merits of PWM control of hydraulic equipment are the robustness of the high spee on-off valve, its low price and the direct control without D/A converter. In the PWM control of high speed on-off valve, the time lag and switching time existing between the input and output signals of valve are considered as demerit points. To get analytical results, the effects of these demerits have to be clarified in detail. The object of this study is to propose a mathematical model for the behavior of high speed on-off valve and to get analytical results of this system. The dynamic characteristics of this system is examined by digital computer simulation analytically and compared with experimental results to varify the proposed mathematical model.

배기 브레이크용 솔레노이드 밸브의 특성 해석 (Characteristics Analysis of the Solenoid Valve for Exhaust Brake)

  • 윤소남;함영복
    • 한국자동차공학회논문집
    • /
    • 제12권1호
    • /
    • pp.190-195
    • /
    • 2004
  • An exhaust brake system is composed of a gate valve, a pneumatic cylinder and an on-off solenoid valve. An on-off solenoid valve which is a key component of the exhaust brake system ought to have characteristics such as high reliability and long life for reducing the foot brake and tires damage, and for driver's fatigue relief of middle/large size vehicles running a long distance. In this paper, an on-off solenoid valve which is used for vehicle brake system was studied. For the performance evaluation of the on-off solenoid, electromagnetic characteristics and dynamic characteristics are analyzed. On the basic study for the performance improvement of exhaust brake system, pneumatic circuit and pneumatic valve of on-off solenoid type were suggested and the performance of pneumatic valve through the test procedure was evaluated.

유압 블리드-오프 회로의 특성 재검토 및 실험적 동특성 모델링 (Reexamination and Derivation of Empirical Dynamic Model for a Hydraulic Bleed-Off Circuit)

  • 정헌술;이광헌;김형의
    • 대한기계학회논문집A
    • /
    • 제26권8호
    • /
    • pp.1552-1564
    • /
    • 2002
  • Meter-in, meter-out and bleed-off circuits are widely utilized in order to adjust the speed of a hydraulic actuator by using a flow control valve and in order to regulate the pressure of a hydraulic volume by using a simple on-off valve. In these circuits, a relief valve serves either to maintain constant system pressure or to protect the system from over-pressure loading. The relief valve of a bleed-off circuit is the second case frequently undergoing on-off action during operation. It makes the analysis of the pressure control characteristics of the circuit highly difficult. In this paper, steady-state flow rate, pressure, heat loss and efficiency of the three circuits are reexamined and basic experiments far obtaining the characteristics of a pump and relief valve are conducted. Finally, simple empirical first-order dynamic models of decreasing and increasing pressure were separately proposed and verified by comparison with experiment. As the result, the basis for the theoretical analysis of the pressure control characteristics of a bleed-off circuit using a simple on-off valve is established.

디젤차량 배기 브레이크용 솔레노이드 밸브의 개발 (Development of Solenoid Valve for the Exhaust Brake of Diesel Engines)

  • 윤소남;함영복;조정대;류병순
    • 동력기계공학회지
    • /
    • 제7권4호
    • /
    • pp.19-24
    • /
    • 2003
  • Exhaust brake system for Diesel engines is composed of gate valve, pneumatic cylinder and exhaust brake valve with on-off solenoid. Exhaust brake valve which is core component of exhaust brake system should have characteristics such as high reliability and long life. In this paper. exhaust brake valve with on-off solenoid which is used for vehicle brake system was studied. For the performance evaluation of on-off solenoid, electromagnetic characteristics and dynamic characteristics are analyzed. As a basic study for the performance improvement of exhaust brake system, pneumatic circuit and pneumatic valve with on-off solenoid were suggested and the performance of the pneumatic valve was evaluated through tests.

  • PDF

고속 온-오프 전자 밸브를 사용한 유압 실린더의 압력 제어 (Pressure Control of Hydraulic Cylinder using high Speed On-Off Solenoid Valve)

  • 김상수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권1호
    • /
    • pp.69-78
    • /
    • 1999
  • In this study a new pattern of pressure control of hydraulic cylinder using high speed On-Off solenoid valve in the electro-hydraulic system has been suggested. The control valve is 3-way high speed On-Off solenoid valve which is operated by PWM(Pulse Width Modulation)control signal. The high speed On-Off solenoid valve has a tendency to induce severe pressure fluctuation in the hydraulic actuator so it has not been used for the purpose of closed loop control with direct pres-sure feedback. In this study closed loop control with direct pressure feedback is enabled by using a digital filter which has linear minimum mean square filter algorithm. Through some experiments it is confirmed that stable pressure control can be realized by the proposed control technique.

  • PDF

유압 전자 파일럿밸브를 이용한 섬유송출기 속도제어에 관한 연구 (A Study on Speed Control of Textiles Let off Using Hydraulic Solenoid Pilot Valve)

  • 이재구;김도태;김성동
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.225-230
    • /
    • 2002
  • Machine of textiles let off is equipment supplying constantly fabrics. Nowdays, as it is replaced band - brake type with hydraulic motor driven type, we looked into characteristic of hydraulic solenoid pilot direction valve(SPDV) for controlling acceleration performance of hydraulic motor. This study deals with controlling the initial speed of textiles let off machine. Finally, to control the initial speed of hydraulic motor, we controlled the adjustment screw of SPDV by a hand. Test which was carried out in the laboratory shows that initial speed of textiles let off could be improved by controlling adjustment screw of SPDV. Also, the results of experiment work were compared with dynamic characteristic of other on/off solenoid direction valve(SDV).

  • PDF

LP가스용 차단기능형 수평식 용기밸브에 대한 설계연구 (Design Study of Automatic Cut-off Horizontal Valve for a LPG Cylinder)

  • 김청균
    • 한국가스학회지
    • /
    • 제19권6호
    • /
    • pp.80-84
    • /
    • 2015
  • 본 연구에서는 기존의 차단기능형 수직식 용기밸브와 새로이 개발된 수평식 용기밸브의 몸체전고와 중량에 대한 설계 데이터를 고찰하였다. 차단기능형 수평식 용기밸브의 전고는 기존의 차단기능형 수직식 용기밸브에 비해 41~42%나 획기적으로 줄어들었다. 또한, 수평식 밸브의 몸체 무게는 기존의 차단기능형 수직식 밸브에 비해 29~40%나 줄어든 결과를 얻었다. 이러한 결과는 단지 기존의 수직식 밸브에서 밸브의 여러 가지 구성요소를 수평식으로 배열을 바꾼 구조변경 설계를 통해 확보한 것이다.

개폐식 밸브를 사용한 공압 서보 시스템의 효율적 밸브 개폐에 관한 연구 (Study on the Effective Operating Method on-off Valves of Pneumatic Servo System)

  • 황웅태;최서호;이정오
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.820-825
    • /
    • 1996
  • This paper is concerned with effective operating method of pneumatic on-off valves for improving position control accuracy, valve life-time and position settling time using modified pulse width modulation with dead-zone. The pneumatic system using on-off valves studied in this paper has advantage of simple construction and low cost compared with a system with servo-valves. The performance of proposed control system is investigated experimentally for the position control of a pneumatic cylinder using on-off valves. Experimental results show that the proposed algorithm for valve operation can be used to obtain fast and accurate position control and to prevent on-off valves from unnecessary switching.

  • PDF

가스밸브의 변형거동 안전성에 관한 유한요소해석 (Finite Element Analysis on the Deformation Behavior Safety of a Gas Valve)

  • 김청균
    • 한국가스학회지
    • /
    • 제21권4호
    • /
    • pp.70-75
    • /
    • 2017
  • 본 연구에서는 차단기능형 수평식 가스밸브와 기존 수직식 가스밸브의 변형거동 안전성을 FEM으로 해석하였다. FEM 해석결과에 의하면, 차단기능형 수평식 가스밸브의 나사부와 가스방출구에 가스내압이 작용할 때 밸브몸체의 우측 끝단부에서 최대 변형량 $4.4{\mu}m$가 발생하였다. 두 번째로 큰 변형량 $2.9{\mu}m$는 안전밸브가 설치된 포트의 끝단부에 형성된 것으로 나타났다. 이렇게 작은 변형량이 발생한 것은 나사부, 가스방출구, 스템 및 스핀들 축이 장착되는 포트, 안전밸브 포트로 구성되는 수평식 가스밸브의 평형이 잘 이루어지도록 설계되었기 때문이다. 반면에 나사부와 가스방출구에 가스내압이 작용할 때, 기존 차단기능형 수직식 가스밸브의 상단부에서 최대 변형량 0.076mm가 형성된 것으로 나타났다. 가스유출구의 좌측 끝단부에서 두 번째로 큰 최대 변형량 0.055mm가 발생하였다. 이러한 변형량은 차단기능형 안전장치의 그루브에 삽입된 오링의 밀봉간극에 영향을 미칠 가능성이 높다. 따라서 본 연구에서는 LPG 용기용 가스밸브의 가스누출을 완벽하게 차단할 수 있는 메커니즘을 갖춘 차단기능형 수평식 가스밸브가 수직식 가스밸브에 비해 우수하다할 수 있다.

긴급차단용 안전밸브의 성능해석 (Performance Analysis of Emergency Shut-Off Safety Valve)

  • 송희용;박경암;고성호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.413-418
    • /
    • 2001
  • Emergency shut-on valve was developed to shut off natural gas at the front of a gas meter in the house. The shut-off flow rate and differential pressure of this valve was controlled by adjusting the distance between the spool and magnet. Also the spool shape was an important factor in the performance of this valve. The experimental and computational results will be useful for the design having better performance.

  • PDF