• Title/Summary/Keyword: Old prosthesis

Search Result 192, Processing Time 0.024 seconds

Rupture of the Traumatic Abdominal Aneurysm -Surgical Experience 1 case- (외상성 복부 대동맥류의 파열 -수술치험 1례 보고-)

  • 김범식
    • Journal of Chest Surgery
    • /
    • v.23 no.4
    • /
    • pp.782-784
    • /
    • 1990
  • We present a case of ruptured abdominal aortic aneurysm caused by blunt injury. The patient was 23-year-old soldier injured by a motor vehicle accident. Injuries sustained a contused abdominal aorta. At the time of aortic repair, the involved segment formed huge pseudoaneurysm, and which had intimal tear. Aorto-iliac graft replacement was carried out with a woven-dacron Y-graft prosthesis, which restored satisfactory circulation to both lower limbs. The postoperative course was uneventful.

  • PDF

Thrombotic Dysfunction of St. Jude Medical Prosthesis in a Child (소아환자에서 St. Jude medical 인공판의 혈전형성 1예)

  • 김삼현
    • Journal of Chest Surgery
    • /
    • v.24 no.1
    • /
    • pp.88-92
    • /
    • 1991
  • Although there have been diverse opinions, permanent anticoagulation is generally recommended in children with mechanical valves. We experienced the thrombotic dysfunction of mitral St. Jude Medical valve in a 4-year-old child who had been under control of anticoagulation with warfarin sodium. Besides the primary problems related to the prosthetic mechanism, various patient factors might have contributed to the valve thrombosis. We would emphasize the necessity of anticoagulation and the close observation for valve dysfunction in pediatric patients with St. Jude Medical valve in mitral position.

  • PDF

Tracheal augmentation with Bovine pericardium (Bovine pericardium을 이용한 기관협착의 치험예)

  • 김부연;이교준;신화균;이응석
    • Journal of Chest Surgery
    • /
    • v.33 no.4
    • /
    • pp.320-323
    • /
    • 2000
  • This case describes a tracheal stenosis complicated by endobronchial truberculosis. A 50-year-old female with progressive dyspnea was referred to us for the management of long segmental tracheal stenosis. Treatment modalities for tracheal stenosis include open surgical resectin and reconstruction, mechanical dilation, laser resection, and placement of an airway prosthesis. The following is a report of a successful treatment of a long segmental tracheal stenosis through a tracheal augmentation and the use of al Bovine pericardium. This technique may provide a relief from tracheal stenosis.

  • PDF

Postpneumonectomy Syndrome -A Case Report- (전폐절제술후 증후군 -1례 보고-)

  • 성숙환
    • Journal of Chest Surgery
    • /
    • v.27 no.12
    • /
    • pp.1047-1051
    • /
    • 1994
  • Airway obstruction may be caused by extreme mediastinal shift and rotation after right pneumonecotmy or after left pneumonecotomy in the presence of right aortic arch.We experienced such a complication after right pneumonectomy, so called right postpneumonectomy syndrome. The patient was 28 years old female, and 4 month ago she had undergone right pneumonecotomy via video assisted thoracoscopic surgery[VATS] for endobronchial tuberculus dissemination and secondary pulmonary infection. She was treated by mediastinal repositioning which were composed of substernal fixation of pericardium and insertion of expandable prosthesis of 1000 cc capacity. She had good postoperative course and now she feels no obstructive symptoms.

  • PDF

Arterial Switch Operation of Transposition of Great Arteries [1 case] (대혈관전위증에 대한 동맥전환술 1례 치험)

  • 김창호
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.153-159
    • /
    • 1986
  • A 11 month old child with transposition of the great arteries and a large ventricular septal defect [VSD] underwent repair by VSD closure and arterial switching with translocation of the coronary ostia. Cardiopulmonary bypass was established along with core cooling to between 18 degree C and low flow was employed. By LeCompte maneuver, we avoided the use of a tubular prosthesis in the repair of pulmonary outflow tract. The post-operative course was uneventful.

  • PDF

APPLICATION OF CAD/CAM FOR ORAL REHABILITATION IN A PATIENT WITH DOWN SYNDROME (CAD/CAM을 이용한 다운 증후군 환자의 구강 재건)

  • Chung, Hyunjin;Shim, Joon-Sung;Choi, Byung-Jai;Lee, Jae-Ho
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.13 no.2
    • /
    • pp.95-98
    • /
    • 2017
  • Due to hypodontia, poor oral hygiene, and significantly more prevalent periodontal disease, patients with Down syndrome show higher incidence of edentulism. Oral rehabilitation of such patients is imperative but challenging as high rates of prosthesis failure are reported due to malocclusion, high masticatory force, and parafunctional habits. As CAD/CAM(Computer-Aided Design and Computer Aided Manufacturing) is the recent trend in prosthodontics, this report discusses the application of CAD/CAM in a Down syndrome patient. A 25-year-old patient with Down syndrome was presented to the Department of Pediatric Dentistry, Yonsei University Dental Hospital for oral examination. 5 maxillary teeth were missing, 3 were fully impacted, and 4 had grade III mobility. The patient underwent general anesthesia for extraction of impacted and mobile teeth, implant surgery, and final impression for prosthesis. Afterwards, CAD/CAM was used to design and manufacture a 10-unit zirconia bridge. However the bridge was fractured after 18 months due to the patient's bruxism and high masticatory force. Final impression taking, bite registration, cast fabrication, cast scanning, and prosthesis designing were not needed as CAD/CAM data remained. Previous CAD/CAM design was used to remanufacture the zirconia bridge. Down syndrome patients have malocclusion, high masticatory force, and parafunctional habits which increase the possibility of prosthesis fracture. CAD/CAM is beneficial for Down syndrome patients as previous digital records can be utilized for prosthesis repair or remake. In detail, application of CAD/CAM in remanufacturing decreases patient's discomfort of impression taking, shortens and simplifies dental laboratory procedures, and reduces clinician's effort of taking detailed final impressions or accurate bite registration. In conclusion, oral rehabilitation using CAD/CAM provides not only satisfactory levels of comfort, stability, and esthetics, but also easier repair or remake compared to conventional prostheses.

Implant-supported prosthetic rehabilitation for the edentulous maxilla using the additive manufacturing technology: A case report (레이저 적층 제조 기술을 이용한 상악 무치악 환자의 임플란트 고정성 보철 수복 증례)

  • Kim, Hee-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.173-178
    • /
    • 2018
  • The direct metal laser sintering (DMLS) technique would be promising for the full-arch implant-supported restorations due to reduced cost and manufacturing time without potential human errors and casting defects. The aims of this case report were to describe the successful outcome of an implant-supported fixed dental prosthesis in the edentulous maxilla by using the DMLS technology and computer-aided design and computer-aided manufacturing (CAD/CAM) monolithic zirconia crowns, and to describe its clinical implications. A healthy 51-year-old Korean woman visited Seoul National University Dental Hospital and she was in need of a rehabilitation of her entire maxilla due to severe tooth mobility. In this case, all maxillary teeth were extracted and an implant-supported fixed dental prosthesis was fabricated that involved a cobalt-chromium (Co-Cr) framework with the DMLS technique and CAD/CAM monolithic zirconia crowns. Six months after delivery, no distinct mechanical and biological complications were detected and the prosthesis exhibited satisfactory esthetics and function. In this case report, with the DMLS system, the three-dimensional printed prosthesis was created without additional manual tooling and thus, reliable accuracy and passive fit were obtained.

Full mouth rehabilitation of the patient with severely worn dentition using monolithic zirconia prosthesis: A clinical report (치아 마모 환자에서 단일 구조 지르코니아를 이용한 완전 구강 회복 증례)

  • Kim, Tae-Yeon;Han, Jung-Suk;Kim, Sung-Hun;Yeo, In-Sung;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.140-145
    • /
    • 2016
  • Excessive occlusal wear causes loss of tooth structure, occlusal plane disharmony, impaired function and esthetic problems. Although the decrease of occlusal vertical dimension may be compensated by the growth of alveolar bone and tooth eruption, minimal increase of occlusal vertical dimension may be required for esthetics and retention of prosthesis. In this case, a 44-year-old male patient visited Seoul National University Dental Hospital with chief complaint of severe tooth wear and shade disharmony. Based on assessment of diagnostic wax-up, 3 mm increase of occlusal vertical dimension was determined. Removable occlusal splint and interim prosthesis was used to ascertain patient's comfort and adaptation. After the adaptation period, definitive prosthesis fabricated with full-contour monolithic zirconia were delivered and the patient was recommended to wear a nightguard device for prosthesis protection. This report presents a case of full mouth rehabilitation with the elevation of patient's occlusal vertical height, resulting in satisfactory esthetics and functions.

Intrusion phenomenon of natural tooth bounded by implant-prostheses: a clinical report (임플란트 사이에 있는 자연치 함입 증례)

  • Kim, Joong-Hyun;Yang, Sun-Bong;Jo, Young-Sung;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.324-330
    • /
    • 2014
  • In case of implant-tooth connected prosthesis, a natural tooth tends to intrude. There are several mechanisms that explain an intrusion phenomenon. So it is reco mmended not to connect an implant with a natural tooth. A 68-year-old female had upper left $2^{nd}$ premolar and $2^{nd}$ molar extracted and underwent implant surgery on the missing area. We made an implant prosthesis and treated upper left $1^{st}$ molar with a gold crown. 2.5 year later, the patient complained about loose proximal contact and food impaction between upper left $1^{st}$ molar and $2^{nd}$ molar. Mesial side of upper left $2^{nd}$ molar implant prosthesis was soldered so that proximal contact became tight again. But after 7 months, about 2 mm intrusion of upper left $1^{st}$ molar occurred, and the patient felt periodontally originated pain on intruded upper left $1^{st}$ molar. After the gold crown on upper left $1^{st}$ molar was removed, extrusion occurred and pain was relived.

Single implant restoration with esthetic prosthodontic treatment in maxillary anterior tooth: A case report (상악 전치부 단일 임플란트의 심미 보철 수복 증례)

  • Kang, Hyeon;Seo, Nu-Ri;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug;Yang, Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.354-359
    • /
    • 2018
  • In a single implant restoration of maxillary anterior teeth, it is difficult to accomplish an aesthetic restoration of the implant prosthesis in the case of gingival recession and bone defect problems. To maintain aesthetic stability in the long term, it is important to place the implant in the ideal position as well as the recovery of the soft tissue and harmony with the prosthesis. Not only ideal implant position but also the harmony with surrounding soft tissues are important to fabricate aesthetic implant prosthesis for these cases. for these cases, a 47- years -old male with lowered level of osseous crest and gingival recession on maxillary anterior tooth was treated with guided bone regeneration and gingival recontouring.