• Title/Summary/Keyword: Oil flow rate

Search Result 358, Processing Time 0.03 seconds

Sonication Effect on the Relative Permeability of contaminated Soil (초음파에 의한 오염토의 상대투수계수의 변화)

  • 김영욱
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • This study investigated the effectiveness of ultrasonic waves on the relative permeability under a range of soil type, flushing rate, and sonication power. This study was conducted in the laboratory using a specially designed and fabricated equipment, and the laboratory study was simulated by ECLPISE 100 which is a commercial black oil simulator. The test results indicated the sonication increased contaminant extraction significantly. From analytical standpoint, sonication caused a change in the relative permeability of the test samples, a reduction in residual oil saturation and an increase in both irreducible water saturation and wettability. These three parameters are highly related with $(C_{10})^2$. The computer software ECLIPSE 100 can be used to analyze the change of the relative permeability due to sonication in two phase immiscible flow.

  • PDF

Separation of Volatile Compounds from Tuna Fish Oil With Supercritical Carbon Dioxide (초임계 이산화탄소를 이용한 참치유로부터 휘발성 성분의 분리)

  • Roh Hyung Seob;Youn Hyun Seok;Jung Sun Mi;Hong Yeon Ryun;Kang Kil Yoon;Chun Byung Soo
    • KSBB Journal
    • /
    • v.20 no.1 s.90
    • /
    • pp.12-17
    • /
    • 2005
  • Despite a wide range of fatty acids in fish oil, its the usage are very limited owing to off-flavors and volatile compounds in the oil. A way to extract and remove volatile compounds was performed at a semi-flow extractor by using supercritical carbon dioxide $(SC-CO_2)$. Samples of the oil were treated at the conditions which ranged from $30\;to\;80^{\circ}C$ and from 80 to 200 bar with 10 mL/min flow rate of carbon dioxide. In the oil the volatile compounds were analyzed by gas chromatography. Before extraction with $SC-CO_2$ the oil sample was detected over 129 peaks but 99 compounds were identified. The results demonstrated that at $40^{\circ}C$ and 200 bar extraction condition the volatile compounds in the tuna fish oil were removed, except for 14 compounds identified after extraction and other $SC-CO_2$ extraction conditions reached to high reduction of the volatile compounds.

An Experimental Study on the Combustion Characteristics in Low Emission Multi-Staged Oil Burner (다단연소를 이용한 저 NOx 버너의 연소특성에 관한 연구)

  • An, Guk-Yeong;Kim, Han-Seok;Jo, Eun-Seong
    • 연구논문집
    • /
    • s.27
    • /
    • pp.101-108
    • /
    • 1997
  • The characteristics of combustion and emissions in multi-staged oil burner have been experimentally studied for the various range of equivalence ratios, drop sizes and fuel formulations. Malvern system was used to measure droplet size of fuel. Light fuel oil and light fuel oil doped with pyridine($C_5H _5N$) were used to investigate the effects on fuel NOx emission. The emissions of NO and CO in exhaust gas and the flame temperatures were measured by the gas analyzer and thennocouples. NOx emissions were increased by increasing the excess air ratio (range:$lambda=1.1-1.4$) or decreasing the SMD of droplet in single-staged burner. In comparison with the single-staged burner, the emission of NOx in multi-staged burner was reduced by 50% but CO emission was slightly increased. It is found that multi-staged burner has a good capability in reducing thermal NOx resulting from the distributed heat release rate and lower flame temperature in fuel-rich and fuel-lean combustion zone. Moreover, the fuel NOx emission of the multi-staged burner is lower than that of single-staged burner, because multi-staged burner has fuel rich zone where fuel N is converted to $N_2$ more than NO. In 3-staged burner, the percentage of each stage combustion air have strong influence on emission characteristics. It is also found that NOx emission can be reduced by decreasing inner and outer air percentage or increasing middle air flow rate and CO emission is vice versa.

  • PDF

A Study on Plume Movement Characteristics of Bubble Boom by PIV (입자영상유속계에 의한 기포붐의 Plume 거동특성에 관한 연구)

  • 조대환;오병주;이영호
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.6 no.1
    • /
    • pp.69-76
    • /
    • 2000
  • Bubble boom may be a good alternative for the prevention of oil spill pollution due to its easy deployment and clean post-process tasks. The present work is focused on the experimental investigation of air bubble movement for the bubble boom by visualization and quantitative PIV measurements. Bubble plume was generated by adjusting the pressure of pressure vessel ranging 6.7 kpa to 14.7 kpa. The results showed at lower inlet velocity and higher supply air flow rate that bubble boom maintained its containing capability reasonably well up to the maximum containing limit.

  • PDF

Analysis oil the Thermal Characteristics of the Spindle with High Frequency Motor according to the Cooling Methods (고주파 모터 내장형 주축의 냉각에 따른 열특성 해석)

  • 김수태;최대봉;조환석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.969-974
    • /
    • 2002
  • Thermal characteristics according to the cooling methods are studied for the three type spindles with high frequency motor. For the analysis, three dimensional mode]s are built considering heat transfer characteristics such as natural and force convection coefficients. Unsteady-state temperature distributions and thermal deformations according to the cooling conditions are analyzed by using the finite element method.

  • PDF

A Study on Reclamation of Waste Plastic: Plant Design (폐기프라스틱의 재활용에 관한 연구)

  • 김용욱;차시환
    • Journal of the Korean Society of Safety
    • /
    • v.3 no.1
    • /
    • pp.37-45
    • /
    • 1988
  • This research investigated the condition for plant design on reclamation of waste plastic by heat decomposition. The results were summarized as follows 1. The highest of oil product by heat decomposition is about 54.7%. 2. The optimum reaction temperature is about 300­40$0^{\circ}C$. 3. The optimum reaction time is 2­3 hours. 4. When the flow rate of 8­16 cm/sec in column reactor the yield is maximum. 5. Waste plastics yielded of carbon black product by heat decomposition at the optimum condition is about 23.5%. 6. Calorific values 0:1 were 9820 Kcal/kg.

  • PDF

A Study on the Cooling Performance of Cutting Oil of Inclined Thermosyphon (경사 열사이폰의 절삭유 냉각성능에 관한 연구)

  • 이정한;이기백;조동현;이종선
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.5
    • /
    • pp.38-44
    • /
    • 2002
  • An experimental investigation was performed to observe the cooling performance of cutting oil and the effect of inclination angle on the transport behaviour of a inclined thermosyphons with low integral-fins. Relatively high rates of heat transfer have been achieved by operating this manner. Water has been used as the working fluid. The inclimation angle of thermoryphon and the ratio of Reynolds number of cooling to hot fluid have been used as the experimental parameters. Heat transfer coefficients at the condenser and the evaporator are estimated from experimental results. The experimental results have been assessed and compared with existing theory. Good agreement with the theory of Yiwei has been found. The maximum heat flow rate in the thermosyphon proved to depend upon the inclination angle.

Comparison between heavy oil combustion test and numerical analysis of combustion phenomena subject to changes in injection characteristics (분무특성에 따른 중유연소 수치해석의 결과와 실험과의 비교)

  • Lee, S.S.;Kim, H.J;Kim, J.J.;Choi, K.S.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.338-343
    • /
    • 2003
  • Computations were performed to investigate the spray characteristics of the twin fluid nozzle in three stage heavy-oil combustion burner. The burner geometry and flow conditions were provided by a burner company. The goal of the study is to estimate mean droplet size, initial velocity and spread factor of the nozzle through comparison between experiments and numerical analyses. Air stage ratio is 2:4:4 by mass, and O2 in exhaust gas is about 4 % by volume. Here, the agreement between the experiment and numerical analyses is evaluated by NOx generation. Spray characteristics will be linearly interpolated between fuel consumption rate l20L/h and 240 L/h.

  • PDF

A Study on the Spontaneous Ignition Characteristics of Wood Pellets related to Change in Flow Rate (공기유량의 변화에 대한 우드펠릿의 자연발화 특성에 관한 연구)

  • Kim, Hyeong-Seok;Choi, Yu-Jung;Choi, Jae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.590-596
    • /
    • 2019
  • Uses of fossil fuels like coal and oil increases with industrial development, and problems like abnormal climate come up as greenhouse gas increases. Accordingly, studies are actively conducted on eco-friendly renewable energy as a replacement for the main resources, and especially, wood pellets with high thermal efficiency are in the limelight as an alternative fuel in thermal power stations and gas boilers. However, despite a constant increase in their usage, few studies are conducted on their risks like fire and spontaneous combustion. Thus, this study found the auto-ignition temperature and critical ignition temperature of wood pellets with a change in flow rate in a thermostatic bath, using a sample vessel with 20 cm in length, 20 cm in height and 14 cm in thickness to predict their ignition characteristics. Consequently, at the flow rate of 0 NL/min, as the core temperature of the sample increased to higher than the ambient temperature, they ignited at $153^{\circ}C$, when the critical ignition temperature was $152.5^{\circ}C$. At the flow rates of 0.5 NL/min and 1.0 NL/min, it was $149.5^{\circ}C$, and at the flow rate of 1.5 NL/min, it was $147.5^{\circ}C$. Consequently, at the same storage, the more the flow rate, the lower the critical ignition temperature became.

Experimental Study on the Diagnosis and Failure Prediction for Long-term Performance of ESP to Optimize Operation in Oil and Gas Wells (유·가스정 최적 운영을 위한 ESP의 장기 성능 진단 및 고장 예측 실험 연구)

  • Sung-Jea Lee;Jun-Ho Choi;Jeong-Hwan Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.71-78
    • /
    • 2023
  • In general, electric submersible pumps (ESPs), which have an average life of 1.0 to 1.5 years, experience a decrease in performance and a reduction in life of the pump depending on oil and gas reservoir characteristics and operating conditions in wells. As the result, the failure of ESP causes high well workover costs due to retrieval and installation, and additional costs due to shut down. In this study, a flow loop system was designed and established to predict the life of ESP in long­term operation of oil and gas wells, and the life cycle data of ESP from the time of installation to the time of failure was acquired and analyzed. Among the data acquired from the system, flow rate, inlet and outlet temperature and pressure, and the data of the vibrator installed on the outside of ESP were analyzed, and then the performance status according to long-term operation was classified into five stages: normal, advice I, advice II, maintenance, and failed. Through the experiments, it was found that there was a difference in the data trend by stage during the long­term operation of the ESP, and then the condition of the ESP was diagnosed and the failure of the pump was predicted according to the operating time. The results derived from this study can be used to develop a failure prediction program and data analysis algorithm for monitoring the condition of ESPs operated in oil and gas wells.