• 제목/요약/키워드: Oil fire

검색결과 225건 처리시간 0.035초

Analysis of Performance and Development of Environment-friendly High Expansion Foam Concentrate (친환경 고발포 소화약제 개발 및 성능 분석 연구)

  • Kim, Ha-Young;Nam, Jun-Seok;Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • 제25권4호
    • /
    • pp.25-29
    • /
    • 2010
  • Foam concentrate is used for fire-extinguishing purposes, occurring foam, mixed with air. In huge oil-fire or the efficiency of fire-extinguishing with small quantity of water, Foam concentrate is used widely. However, perfluorooc tanoicsulfonate and nonylpenol that are included in Foam concentrate could be exposure in danger while they were discharged. The purpose of the research is the development of environment-friendly high expansion foam that exclude the dangerous substances and improvement of danger of the existing foam concentrate. The developed foam is analyzed as the environment-friendly foam in indexes of the environment-toxicity, the biodegradation appraisal, and the dangerous substances-detecting. In addition, the performances of expansion rate, discharge rate, and fire-extinguishing are suitable in the domestic regulation, so it is useful for fire-extinguishing in real fire situation.

Extinguishing Characteristics of Zeolite adsorbed Dry Chemical Powder (분말 소화약제가 흡착된 제올라이트의 소화 특성)

  • Shin, Changsub;Park, Hojun
    • Journal of the Korean Society of Safety
    • /
    • 제27권6호
    • /
    • pp.59-63
    • /
    • 2012
  • The use of dry chemical powder has been increased as it can be stored for a long period and sustain in stable condition compared to gas or liquid phase extinguishing agents. A new type of dry chemical powder using Zeolite was produced in the research. Chemical powder was adsorbed into Zeolite 13X, a porous material appearing negative catalytic effect, to create extinguishing powder obtaining core shell structure and measured physical properties and run a small scale fire extinguishment. SEM, XRD, TA analysis was also executed, and extinguishing characteristics were measured by fire extinguishing experiment on oil pool fire. The experiment showed that the average particle size of Zeolite 13X was equivalent, indicating about $3{\pm}1{\mu}m$ and thermal analysis result illustrated that Zeolite 13X showed exothermic reaction peaks at $900^{\circ}C$ due to solid-state transformation. Extinguishing characteristics on oil fire of $NaHCO_3$/Zeolite 13X and $NH_4H_2PO_4$/Zeolite were improved, influenced by adsorbed extinguishing powders on Zeolite 13X and Zeolite 13X that contains high phase transition temperature.

The Study Fire Mechanism and Real Fire Correlation of Power Condenser (전력용 콘덴서의 화재메커니즘과 실제 화재상관관계 연구)

  • Baek, Donghyun
    • Fire Science and Engineering
    • /
    • 제31권6호
    • /
    • pp.112-117
    • /
    • 2017
  • This research discusses the correlation about fire mechanism based on real fire cases. Electric power condenser failure mechanism is classified into 7 steps and fire mechanism is classified into 12 steps. In the 5th step, the procedure of operating a protection channel of a protection relay was identical in the case of the failure and fire. As the fire occurrence mechanism was applied from the 6th step, internal pressure was increased because of gas generation produced by internal combustion phenomenon and arc. This caused explosion in 10st step of fire occurrence mechanism. In 11th step, the flame such as arc gushed out with insulating oil which caused fire and leaded to second accident. This kind of step correlation could play an important part to examine fire.

Research of Flow Electrification Phenomena of the used Environment-Friendly Vegetable Insulating Oils (친환경 식물성절연유의 유동대전현상 연구)

  • Choi, Sun-Ho;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제61권4호
    • /
    • pp.580-584
    • /
    • 2012
  • The insulating oils perform a cooling and insulation action in electric power transformer. The mineral oil has immanent fire dangerousness and environmental contamination problem. Vegetable insulating oil has higher ignition point, flash point and more excellent biodegradability than conventional mineral oil. In a real oil-filled transformers, some of the power is dissipated in the form of heat. And transformer require the heat to be removed from the winding and insulator by forced convection of the insulating oil. The flow electrification occurs when insulating oil was forced to be circulated. In this paper, influence of temperature, velocity of flow, and insulating pipe and diameter on streaming electrification of vegetable insulating oil was investigated using forced circulation apparatus. Temperature effects were most significant, and it showed a peak in the temperature $30^{\circ}C$ to $35^{\circ}C$ at insulating and copper pipe. The change of flow electrification according to area variety could be checked by change of diameter.

A Study on the Development of Fire Extinguishing System for Machinery Spaces of a Small craft (무인기관실에 효과적인 자동소화장치개발 관한 연구)

  • Lee, Chan-Jea;Kang, Dae-Sun;Kim, Dong-Suk;Kwark, Ji-Hyun
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.127-128
    • /
    • 2006
  • A study developing the dry powder fire extinguishing system inside the simulated machinery spaces of small boats was performed. Fire tests were conducted inside the compartments having volumes 2.9, 4.5, $8m^3$ respectively. The openings and fans were established on the walls of the compartments. Diesel oil was used for the test fuel, In addition fire extinguishing nozzles using dry powder were installed downward at ceiling and horizontally at the wall or conner. All fires in the test were extinguished under system activation and there was no reignition.

  • PDF

Performance Based Design of Passive Fire Protection Using Consequence Analysis (사고 영향 분석을 이용한 성능위주의 내화설계)

  • Han, Dong-Hoon;Lee, Jong-Ho
    • Journal of the Korean Society of Safety
    • /
    • 제19권1호
    • /
    • pp.102-107
    • /
    • 2004
  • Performance based design is a recent evolutionary step in the process of designing fire protection systems. In essence, it is a logical design process resulting in a solution that achieves a specified performance. Sometimes the prescriptive solutions presented in various codes and standards are too expensive or inflexible. Often the solutions do not and enables optimization of a solution for cost and function. In this study, performance based design was carried out to determine the extent of passive fire protection for oil terminal facilities. The results of performance based design were compared with those of prescriptive code based design. Performance based design is not always more economic than prescriptive code based design but provides more reliable and effective design that is fit for the purpose.

Fire Safety Assessment Based on FSA and Risk Reduction of Machinery System Considering Functional Safety (기능적 안전을 고려한 FSA기반 기관 구역 화재 안전성 평가 및 개선)

  • Suh, Sung-Won;Yang, Young-Soon;Chung, So-Yeon;Ryu, Won-Sun
    • Journal of the Society of Naval Architects of Korea
    • /
    • 제49권3호
    • /
    • pp.239-246
    • /
    • 2012
  • It is the well-known fact that most part of goods transported are moved on the unfavorable ocean and even a small amount of accident on sea is extremely dangerous for human lives, financial losses, and social responsibility. Among the several causes of accidents, those by fire have occurred frequently and their damage has been highly serious. The aim of this paper is to assess the risk of fires due to oil leakage in the machinery space. To define the possible fire scenario, our team has performed the search of casualty database and reviewed the previous and various studies in the field. As a result, it is noted that the quantitative risk of the fire scenario have been evaluated on the ground of the FSA risk model. The expected frequency of a fire amounts to incidents during the life of a ship, and the expected financial damage amounts to 5,654 USD per a ship. By adopting Safety Instrumented System (SIS) introduced in IEC 61508 and IEC 61511, SIS model is designed to prevent oil leakage fire as a risk reduction method. It is concluded that System Integrity Level (SIL) 1 seems to be appropriate level of SIS.

The Quenching Ability of Flame Arrester (화염방지기의 소염성능)

  • Ryu, Eun-Ryeol
    • Fire Protection Technology
    • /
    • 통권11호
    • /
    • pp.23-30
    • /
    • 1991
  • For the prevent of fire accident or explosion disasters from inflammable gas and vapour, flame arresters are used in chemical equipment, oil tank or other similar installation. The flame arresters have been used mainly wire gauze type. Wire gauze type flame arrestes is affected several factors. We have know that the quenching ability has a great of difference the preference in accordance with flame velocity, direction of flame propagation and wire net of mesh and number of qauze and introduce examination result data quoated from the abroad.

  • PDF

A Study on the Early Response System Subway Cabin Arson Fire (지하철 차량 방화사고 초기대응에 관한 연구)

  • Roh, Sam-Kew;Ham, Eun-Gu;Kim, Si-Gon
    • Fire Science and Engineering
    • /
    • 제20권2호
    • /
    • pp.21-30
    • /
    • 2006
  • Since Daegu subway arson fire disaster in 2003, there have been several copycat crimes such as at Seoul Metro line number seven and Hongkong Chuiwan line cases. Oil and gas were used for fire propagation in most cases as in Daegu case and such fire could be expanded to a whole subway cabin within several minutes. The fire may eventually cause the whole subway system stop. Fire damage can be minimized when fire occurrence and diffusion are blocked by stages or isolated rapidly. This study suggests an effective early response system that separates passengers from fire and a real-time fire extinguishment program by stages. Based on the subway arson case studies, the early response scenario has been structured by three stages, i.e., confirmation of fire and damage, early fire extinguishment, and information dissemination and passengers evacuation.

A Study on the Safety Distance of the Fuelling Facilities by the Radiation Heat in the Fire at the Gas Station (주유소 내 부대시설 화재발생시 복사열에 따른 주유설비 안전거리에 관한 연구)

  • Kim, Kisung;Lee, Sangwon;Song, Dongwoo
    • Journal of the Korean Institute of Gas
    • /
    • 제25권6호
    • /
    • pp.7-13
    • /
    • 2021
  • Various research has been done on fires and explosions at gas stations at home and abroad. However, only studies of off-site damage in the event of fire at the gas station were conducted, and research on fire at the auxiliary facilities in the gas station was insufficient. The gas station is a place where anyone can easily access dangerous goods. As the risk of fire increases due to the recent increase of auxiliary facilities such as convenience stores and car repair shops in gas stations, it is important to detect the effects of fire on the main oil refinery in case of fire and to verify the validity of existing regulations. In this thesis, we conducted a study to find out the effect of radiation heat on the separation between fixed and fixed oil reactors in the event of fire at an auxiliary facility. Simulation was modelled using FDS 5.5.3 Version, and the size of the fire source was configured with 13 fire assessment devices and the heat emission rate per unit area was entered. Simulation shows that the separation distance of 2 m does not secure the safety of the gas pump in the event of fire at the auxiliary facilities, and radiation heat does not damage at the separation distance of at least 4 m. Accordingly, facilities that can block radiant heat in the event of fire at auxiliary facilities, and measures to limit the use of auxiliary facilities or to re-impose the separation between buildings and fixtures will be needed.