• 제목/요약/키워드: Oil fire

검색결과 226건 처리시간 0.027초

티타늄 합금 폐기물의 연소 특성에 관한 실험적 연구 (Experimental study on the combustion characteristics of titanium alloy)

  • 이준식;남기훈
    • 한국산업융합학회 논문집
    • /
    • 제22권2호
    • /
    • pp.105-110
    • /
    • 2019
  • Most titanium alloy waste with cutting oil was discarded without recycling process so that it can be caused by metal and oil fires. However, there is no fire management system and studies on the titanium or titanium alloy waste in spite of high fire risk. The purpose of this experimental study is to identify the fire risk of the titanium alloy waste with cutting oil. We collected the 120g waste which was made in the biomedical titanium alloy cutting process. The waste was burned and conducted thermal image analysis with infrared camera. The experimental results which illustrated the process, characteristics, and trends of fire are presented. Firstly, the cutting oil was burned and partially the titanium alloy waste was burned. The maximum temperature of the fire was more than $650^{\circ}C$ in some specific spots. These results means when a lot of titanium alloy waste with cutting oil was ignited, this fire could connect the titanium fire. In other words, the fire has a flammable liquid fire and combustible metal fire at the same time. The experimental study could be used fire prevention, response, and investigation of the titanium alloy waste.

대두유의 물리적 특성에 따른 화재감식 (Fire Identification based on Physical Properties of Bean Oil)

  • 진복권;정수일
    • 한국화재소방학회논문지
    • /
    • 제22권3호
    • /
    • pp.246-251
    • /
    • 2008
  • 일반적으로 유류화재의 경우 상온 상압 하에서 그 물리적 성질과 에너지 특성이 유사한 양상을 나타내나 식용유에 의한 화재발생은 그 특성이 매우 특이하여 취급자의 무지로 인한 화재가 자주 발생하고 있다. 따라서 본 연구에서는 식용유에 대한 에너지 특성과 그 물적 성질을 고찰한 연후 실제 연소실험을 통하여 식용유에 대한 물리적 성질을 검증하였다. 뿐만 아니라 실제 화재사례를 통하여 식용유에 의한 화재원인을 감식하였고 식용유화재 방지를 위한 대응방안을 고찰하여 제시 하였다.

식물성 절연유와 광유가 사용된 유입변압기의 온도분포 특성 (Analysis on the Temperature Distribution Characteristics of Insulating oil of Transformer Using the Vegetable oil and Mineral oil)

  • 안정식;심명섭;정중일;김남렬;허창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1215_1216
    • /
    • 2009
  • Most transformer use insulating and cooling fluids derived from petroleum crude oil, but mineral oil is some possibility of environmental pollution and fire with explosion. vegetable oil fluids extracted from seed has superior biodegradation and fire-resistant properties including an exceptionally high fire point enhancing fire safety. In this study, it is aimed at the practicality of substituting natural ester dielectric fluid for mineral oil in liquid insulation system of transformers. As a rise in coil winding temperature has a direct influence on transformer life time, it is important to evaluate the temperature rise of coil winding in vegetable oil in comparison with mineral oil. Three transformers for the test are designed with 10KVA, 13.2KV, one phase unit. The temperature are directly measured in insulating oil of these transformers with the two sorts of natural ester and mineral oil dielectric fluid respectively. Temperature of vegetable oil transformers was similar to temperature of mineral oil transformer in the same design at 80% load and above.

  • PDF

선박화재 적용 단백포 소화약제의 안정제에 따른 소화특성 (Characteristics of Protein Foam Agent by Stabilizer on the Ship Fire Extinguishment)

  • 이응우;신창섭
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.79-85
    • /
    • 2015
  • Onboard fire extinguishing system is important to protect cargo and human lives and every oil tanker has foam type fire extinguishing system. Because of environmental problem, agent which contains materials such as Perfluorinated compounds are regulated and the development of the environmental friendly agent is required. The protein foam has less environmental pollution problem and has an excellent fire extinguish performance to oil fire. In the research, bivalency metal salts were added as stabilizer to increase fire resistance and stability of the foam. Ferrous sulfate, Iron chloride and Nickel chloride were used and to adjust to vessel, sea water was applied. As a stabilizer increased, the expansion ratio was raised. However 25% drainage time was decreased over 2.0 wt.% which is knowable that the foam brokes easily. The amount of generated foam was measured to check fluidity of foam and it appeared that when $FeSO_4$ 1.2 wt.% was added, the amount of generated foam reached large and also the 25% drainage time was high. To evaluate the fire extinguishing performance for oil fire, the small scale oil fire test was executed. When $FeSO_4$ 1.2 wt.% was added, fire extinguishing time was in its shortest which informs fluidity of foam and stability are important factors on fire extinguishing efficiency.

에어프라이어의 화재사례와 재현실험을 통한 화재위험성 분석 (Fire Risk Analysis through Airfryer's Fire Cases and Reproduction Experiments)

  • 이정일;조명식
    • 대한안전경영과학회지
    • /
    • 제22권2호
    • /
    • pp.39-46
    • /
    • 2020
  • This paper recognizes the risk of ignition of air fryer (machine that can cook fried dishes with hot air without oil) that is far exceeding the sales rate of microwave ovens, which is necessary to modern household kitchen, and identifies fire risk through the operation principle of the process of heat transfer, and the main structure of the machine. The fire test that we conducted is to observe the risk of ignition of the machine due to the damage to the safety system and the possibility of igniting oil paper along with food, to experiment with the possibility of ignition due to blockage of the exhaust due to obstacles, and accumulation of oil stains on the hot wire, and to present the method of fire control and devise countermeasures.

석유류 POOL FIRE에 있어서의 열적인 영향(I) (Thermal Effects in the Pool Fire of Fuels(I))

  • 정국삼;강민호;이덕영
    • 한국안전학회지
    • /
    • 제11권1호
    • /
    • pp.75-83
    • /
    • 1996
  • This paper was concerned with pool fire about many used kerosene and diesel oil. In order to know the thermal effects of kerosene and diesel oil, temperature change in the pool fire of these fuels were obtained as a variation of combustion time and the tank's height and diameter by using the data acquisition system, And fuel combustion velocity were derived as a function of the diameter and wall thickness of tanks and combustion time. As a result, when the tank's height was 15㎝, the greater diameter the higher temperature rising regardless of tank's wall thickness and fuels. But, when the tank's height is 30㎝, temperature rising was not higher than 15㎝. Also, temperature rising in the pool fire of kerosene much higher than diesel oil. Kerosene's combustion velocity was about two times faster than diesel oil. And, kerosene's combustion velocity was increased according to the increasing of tank's diameter and combustion time. But, diesel oil's combustion velocity was a little increased or not. Surrounding temperature change of tank with the pool fire was obtained temperature distribution of 0∼35℃ according to the change of tank's diameter and distance from the tank's wall.

  • PDF

식물성절연유의 가속열화에 따른 장기적 안정성 분석 (Research of Accelerated Aging According to Long-term Stability of Vegetable Oil)

  • 최순호;허창수
    • 전기학회논문지
    • /
    • 제61권8호
    • /
    • pp.1148-1152
    • /
    • 2012
  • The vegetable-based insulating oils are substitutes for mineral oils in oil-filled transformer. The important properties of vegetable insulating oil is their higher flash/fire point and biodegradability than conventional mineral oils. The large oil-filled transformer eliminate the risk of explosion and fire should the transformer fail and oil ignite owing to high flash/fire point of vegetable insulating oil. In addition, higher biodegradability of vegetable insulating oils can let the oil spill damage reduced. In this experiment, the real oil-filled transformers using mineral oil and vegetable oil have accelerated aging. After working on the 100% accelerated aging experiment were conducted comparing the transformer. The hottest-spot temperature using thermal coefficients were calculated to determin the degree of accelerated aging. As a result, apply mineral oil transformer in accordance with the accelerated aging life come to an end. In contrast, vegetable insulating oils showed the opposite characteristics. Vegetable insulating oil compared to the mineral oil are found to be an long life. As a result, the vegetable oil has a long-term stability.

옥외저장탱크 누출, 폭발 및 화재사고 대응방안에 관한 고찰 (The Study on the Countermeasure Plans about Leakage, Explosion and Fire Accidents of Atmospheric Storage Tank)

  • 이갑규
    • 한국화재소방학회논문지
    • /
    • 제30권6호
    • /
    • pp.48-56
    • /
    • 2016
  • 지난 2014.4.4.(금)14:50, 울산소재 대형 옥외저장탱크에 원유 충전 중 누출사고가 발생하여 사고현장에 긴급구조통제단이 가동됐다. 사고업체, 소방기관 및 유관기관이 지휘소에 모여 대응과 수습방안을 논의한 뒤 전원차단 및 시설작동금지, 가스농도 측정, 유증기 발생 억제, 누출 원유를 타탱크와 공정과정으로 이송, 해양오염 방지조치 등의 협업체계를 구축하여 수습하였다. 이 수습과정에서 유증기 발생방지와 점화원 차단을 가장 중시하여 조치함으로써 사고업체와 소방기관이 가장 우려했던 폭발과 화재사고는 발생하지 않았다. 이에 본 연구는 일반적인 재난의 긴급구조통제단과는 달리 운영해야 할 옥외탱크의 유류 누출, 폭발 및 화재 시의 긴급구조통제단 운영체계개선을 제시하고, 옥외탱크 유류 누출로 인한 폭발과 화재사고로 전이했을 경우를 가정한 방유제 바닥 종류에 따른 화염 확산속도와 연소시간을 실험 비교하였다. 또한, 소방차 포 노즐의 방사각도와 펌프압력에 따른 방사거리와 포의 도포면적을 실험 분석하여, 이후 옥외저장탱크의 유류 누출로 인한 폭발과 화재 시를 대비한 효과적인 현장대응과 수습방안을 제시하는 데 중점을 두었다.

배전용 변압기에서의 고온열화와 열 사이클 열화에 따른 식물유와 광유의 특성 분석 (Analysis of Accelerated Aging Natural Ester Oil and Mineral Oil in Distributional Transformers)

  • 안정식;최순호;방정주;정중일;허창수
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1163-1168
    • /
    • 2011
  • Most transformers use insulating and cooling fluids derived from petroleum crude oil, but mineral oil has some possibility of environmental pollution and fire with explosion. vegetable oil fluids extracted from seed has superior biodegradation and fire-resistant properties including an exceptionally high fire point enhancing fire safety. In this study, it is aimed at the practicality of substituting natural ester dielectric fluid for mineral oil in liquid insulation system of transformers. As a rise in coil winding temperature has a direct influence on transformer life time, it is important to evaluate the temperature rise of coil winding in vegetable oil in comparison with mineral oil. Four transformers for the test are designed with 10KVA, 13.2KV, one phase unit. The temperature are directly measured in insulating oil of these transformers with the two sorts of natural ester and mineral oil dielectric fluid respectively. Experiment for aging carry out two means. First means remained $120^{\circ}C$ that transformer of mineral oil were operated at 185% load. Second means is that insulating oils of two natural ester and mineral oil were aged by thermal cycles repeating from $30^{\circ}C$ to $120^{\circ}C$. For the heating, Transformers were operated at 185% load. For the cooling, cooling system was operated in the chamber. Samples were analyzed at 42, 63, 93, 143, 190, 240 300cycles. Analysis contents are dielectric strength, total acid value. Mineral oils compared results of first means with results of second means. And compared two sort natural esters respectively with mineral oil in second means.

경유와 메탄올의 유출표면에 따른 화재특성에 관한 실험적 고찰 (An Experimental Investigation on Fire Characteristics of Light Oil & Methanol for Spilled Surface)

  • 이정윤;정기창;김홍
    • 한국안전학회지
    • /
    • 제25권6호
    • /
    • pp.103-108
    • /
    • 2010
  • In this study, tank truck incidents of road transport of hazardous materials to experimental investigated the potential fire hazard. Real scale fire was to perform experiments for on this qualitative and quantitative data collection and analysis. Particularly affected by radiant heat from the flames caused and damage estimates range investigated accordingly. Flame temperature, internal temperature of tank and emitted radiation from the flames was investigated. The flame of light oil spill caused a fire at a temperature of about $300^{\circ}C$ high in comparison with the methanol by combustion of diesel and methanol, according to the difference, the flame duration changes varies depending on the Burning rate, amount of radiant heat flux from light oil fire was 4 times increases compared with fire of methanol. Depending on spill locations(kinds of road surfaces, absorbing rate) and the longer the duration of the flame important factors for the internal temperature of tank truck rise was found. Dirt roads than paved road accident in a fire caused by leakage of hazardous was could the higher the damaged. Therefor, Fire suppression activities should be required in particular to be around.