• 제목/요약/키워드: Oil Flow Standard

검색결과 30건 처리시간 0.025초

Numerical Analysis of Centrifugal Impeller for Different Viscous Liquids

  • Bellary, Sayed Ahmed Imran;Samad, Abdus
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권1호
    • /
    • pp.36-45
    • /
    • 2015
  • Oil and gas industry pumps viscous fluids and investigation of flow physics is important to understand the machine behavior to deliver such fluids. 3D numerical flow simulation and analysis for different viscous fluids at different rotational speeds of a centrifugal impeller have been reported in this paper. Reynolds-averaged Navier Stokes (RANS) equations were solved and the performance analysis was made. Standard two equation k-${\varepsilon}$ model was used for the turbulence closure of steady incompressible flow. An inlet recirculation and reverse flow in impeller passage was observed at low impeller speeds. It was also found that the higher viscosity fluids have higher recirculation which hinders the impeller performance.

천연가스를 파이럿오일과 이원공급하는 직접분사식 2행정 디이젤기관의 시뮬레이션 (Simulation of Natural Gas Injected Dual-Fuel DI 2-Stroke Diesel Engine)

  • 최인수
    • 한국자동차공학회논문집
    • /
    • 제3권3호
    • /
    • pp.9-18
    • /
    • 1995
  • The substitution of conventional fuel oil by alternative fuels is of immense interest due to liquid oil shortage and requirements of emission control standard. Among the alternative fuels, natural gas may be the most rational fuel, because of its widespread resource and clean est burning. Meanwhile, engine simulation is of great importance in engine development. Hence a zero-dimensional combustion model was developed for dual-fuel system. Natural gas was injected directly into the cylinder and small amount of distillate was used to provide the ignition kernel for natural gas burning. The intake air and exhaust gas flow was modeled by filling and emptying method. Although the single zone approach has an inherent limitation, the model showed promise as a predictive tool for engine performance. Its simulation was also made to see how the engine performance was influenced by the fuel injection timings and amount of each fuel.

  • PDF

Offshore 선 Process 배관계의 밸브 소음/진동 평가 절차 (Valve induced noise and vibration evaluation procedure for process piping of offshore production facility)

  • 이주헌;최충영;김재홍;권혁
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.201-204
    • /
    • 2014
  • Recent year, the vibration induced fatigue and noise of piping work become critical in offshore hydrocarbon production facilities with increasing requests by major oil company. In this paper, the risk base piping vibration induced fatigue assessment of NORSOK L-002 standard and UK Energy Institute guideline have been introduced with real project application practice. Also the piping breakout noise evaluation by flow restriction devices of compressible and in-compressible flow are reviewed with its practical application on real project.

  • PDF

가열증류법에 의한 식용유지의 잔류농약 분석법 개발 (Residual Pesticide Analysis Method of Edible Oil via Heat Distillation Methods)

  • 손미희;김재관;조영선 ;한나은 ;김병태 ;박명기;박용배
    • 한국식품위생안전성학회지
    • /
    • 제38권3호
    • /
    • pp.89-98
    • /
    • 2023
  • 현재, 국내에서는 가공식품인 식용유지에 대한 잔류농약 허용기준이 설정되어 있지 않아 잔류농약은 식용유 품질평가의 사각지대라 할 수 있다. 본 연구에서는 식용유지에서 가열증류법을 이용하여 68종의 농약을 대상으로 추출 및 정제법을 최적화하여 GC-MS/MS 분석법을 확립하였다. 가열증류법은 가열온도 및 시간의 영향을 받았으며 이동상의 역할을 하는 질소의 유량과 용출용매의 종류에는 큰 영향을 받지 않는 것으로 나타났다. 본 연구에서 잔류농약의 결정계수(R2)는 0.99 이상으로 나타났고, 정량한계(LOQ)는 0.01-0.02 mg/L이었으며, 대두유를 이용하여 0.01, 0.02, 0.1, 0.5 mg/L 수준으로 회수율 실험 결과 평균 회수율(n=5)은 66.1-120.0%이었고 상대표준편차는 ±10%이하로 나타났다. 또한 실험실내 일간정밀도는 11%이하로 조사되어, 식품의약품안전평가원의 '식품등 시험법 마련 표준절차에 관한 가이드라인(2016)'에 적합한 수준임을 확인하였다. 따라서 본 연구에서 개발한 시험법은 식용유지의 잔류농약 안전관리를 위한 시험법으로 활용이 가능할 것으로 기대된다.

Performance evaluation study of a commercially available smart patient-controlled analgesia pump with the microbalance method and an infusion analyzer

  • Park, Jinsoo;Jung, Bongsu
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권2호
    • /
    • pp.129-143
    • /
    • 2022
  • Background: Patient-controlled analgesia (PCA) has been widely used as an effective medical treatment for pain and for postoperative analgesia. However, improper dose errors in intravenous (IV) administration of narcotic analgesics from a PCA infusion pump can cause patient harm. Furthermore, opioid overdose is considered one of the highest risk factors for patients receiving pain medications. Therefore, accurate delivery of opioid analgesics is a critical function of PCA infusion pumps. Methods: We designed a microbalance method that consisted of a closed acrylic chamber containing a layer and an oil layer with an electronic balance. A commercially available infusion analyzer (IDA-5, Fluke Co., Everett, WA, USA) was used to measure the accuracy of the infusion flow rate from a commercially available smart PCA infusion pump (PS-1000, UNIMEDICS, Co., Ltd., Seoul, Korea) and compared with the results of the microbalance method. We evaluated the uncertainty of the flow rate measurement using the ISO guide (GUM:1995 part3). The battery life, delay time of the occlusion alarm, and bolus function of the PCA pump were also tested. Results: The microbalance method was good in the short-term 2 h measurement, and IDA-5 was good in the long-term 24 h measurement. The two measurement systems can complement each other in the case of the measurement time. Regarding battery performance, PS-1000 lasted approximately 5 days in a 1 ml/hr flow rate condition without recharging the battery. The occlusion pressure alarm delays of PS-1000 satisfied the conventional alarm threshold of occlusion pressure (300-800 mmHg). Average accuracy bolus volume was measured as 63%, 95%, and 98.5% with 0.1 ml, 1 ml, and 2 ml bolus volume presets, respectively. A 1 ml/hr flow rate measurement was evaluated as 2.08% of expanded uncertainty, with a 95% confidence level. Conclusion: PS-1000 showed a flow accuracy to be within the infusion pump standard, which is ± 5% of flow accuracy. Occlusion alarm of PS-1000 was quickly transmitted, resulting in better safety for patients receiving IV infusion of opioids. PS-1000 is sufficient for a portable smart PCA infusion pump.

브레이커 소음측정시스템을 활용한 소음의 측정 및 평가 (Measurement of Breaker Noise by Using Breaker Noise Measurement System)

  • 이재원;강대준;구진회;박형규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1173-1176
    • /
    • 2007
  • The breaker noise is one of the main noise sources of construction site. It is very important to assess and measure the breaker noise accurately, because the noise labelling will be in effect January 2008 in Korea. Therefore, It is necessary to measure the sound power level of breakers and use a appropriate test method in accordance with international standard. In this study, we measure the sound power level of breakers by using the breaker noise measurement system. This system makes it possible to measure the breaker noise more accurately than to measure the noise of that attached with excavator, because this system can control main factors affecting breaker noise such as hydraulic input power, hydraulic supply pressure, breaker inlet oil flow and so on.

  • PDF

이중 탄성중합체 시일의 절단부 오일누유 예측 (Oil Leakage Prediction through Cut Part of Double Elastomeric Seal)

  • 이택성;김연희
    • 한국전산구조공학회논문집
    • /
    • 제36권3호
    • /
    • pp.165-171
    • /
    • 2023
  • 건설기계와 특장차의 상부와 하부 구조를 연결하는 로터리 조인트는 축과 하우징이 회전하면서 유압을 전달하는데 오일의 유로에 누유를 방지하기 위해 여러 개의 시일이 조립된다. 시일재료는 강성이 커서 조립에 어려움이 있기 때문에 자른 후 조립하는 방법을 모색하였다. 절단면의 모양은 L형과 /형으로 하였고 유압이 작용할 때 누유 기준은 절단면에 발생하는 접촉압력으로 하였다. 시일의 구조와 재료는 이중 탄성중합체로 구성되며 강성이 큰 PE 재질만 절단한 경우에 대하여 비선형 접촉 구조해석을 수행하였다. 연구결과 절단 길이가 짧을수록 누유 방지에 유리하며 PE와 하우징이 접촉하는 윗면보다 NBR과 PE가 접촉하는 아랫면으로 누유될 가능성이 큰 것으로 나타났다.

유류오염 토양/지하수 정화를 위해 개발된 DSB(Deep-Site Biopile) System 현장적용특성 (Site Application Characteristics of Deep-Site Biopile System for Cleaning Oil-Contaminated Soil/Underground Water)

  • 한승호;공성호;강정우
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제10권2호
    • /
    • pp.28-34
    • /
    • 2005
  • 본 논문은 유류로 오염된 부지를 DSB(Deep-site Biopile) system을 이용하여 정화함으로써 적용 가능한 현장특성을 평가하기 위한 것이다. 오염부지는 유류가 유출되어 깊이 약 2.5 m 부근에 위치하는 지하수의 흐름에 띠라 광범위하게 오염(총 $7,201m^3$) 되어 있었으며, 투수성이 좋은 Sand층으로 구성되어 있다. 부지 내 설치된 배관은 각 지점마다 독립적으로 제어될 수 있도록 하였으며, DSB system의 가동은 24시간을 기준으로 30분 가동/30분 정지되도록 하였다. 오염부지 내 오염원이 저감되는 현황을 파악하기 위하여 DSB system 가동시간에 따른 시료채취 작업을 수행한 결과, DSB system 가동 후 약 30여일 만에 총석유계탄화수소 및 BTEX 오염원이 약 50% 이상 저감되었으며 약 165일이 경과한 후에는 토양오염 확인기준 이하로 저감되어 정화작업이 정상적으로 완료되었다. 이와 같이 본 DSB system은 기존에 적용되어 왔던 생물학적 공법들과는 달리 높은 농도의 유류화합물로 오염되어 있는 토양 및 지하수를 약 6개월의 단기간에 효과적으로 처리할 수 있었으며 정화 system을 지상이 아닌 지중에 설치함으로써 별도의 부지가 확보되지 않은 경우에도 적용할 수 있는 특성이 있음을 알 수 있었다.

압축공기포 소화설비의 공기포비에 따른 B급 소화성능 연구 (A Study on B Class Fire Extinguishing Performance of Air Ratio in the Compressed Air Foam System)

  • 이장원;임우섭;이동호
    • 한국화재소방학회논문지
    • /
    • 제27권6호
    • /
    • pp.8-14
    • /
    • 2013
  • 본 연구는 압축공기를 포수용액(수성막포 3%)에 주입하여 발포하는 압축공기포 소화설비에서 가압 공기 혼입 비율에 따른 소화성능을 평가하고자 하였다. 실험장치는 캐나다국립연구소 및 UL162 기준을 준용하여 제작한 압축공기포전용의 포소화설비 실험장치를 활용하였으며, 소화모형은 소화약제의 형식승인 및 제품검사의 기술기준에 의한 유류화재(B급) 20단위 모형을 적용하였다. 압축공기는 공기혼합기를 통하여 주입하였으며, 공기포비를 1 : 4, 1 : 7, 1 : 10으로 증가시키면서 경향성을 연구하였다. 또한 공기포비 1 : 4에서 합성계면활성제포와 수성막포의 비교 실험도 함께 진행하였다. 소화 성능실험 결과 동일한 방출유량 조건에서 수성막포는 공기포비 1 : 7에서 소화효과가 가장 빠르게 나타났으며 공기포비 1 : 10에서 가장 소화시간이 길게 나타났다. 또한 수성막포와 합성계면활성제포간 비교 실험에서는 수성막포의 소화효과가 더 빠르게 나타났다.

고압공기분사를 이용한 유류오염토양 세척기법의 적용성 연구 (Applicability of Washing Techniques Coupled with High-Pressure Air Jet for Petroleum-contaminated Soils)

  • 최상일;김강홍
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제11권6호
    • /
    • pp.61-68
    • /
    • 2006
  • 유류오염토양에 대한 고압공기분사를 이용한 세척기법의 적용성 연구를 위하여 저유소 주변의 실제 디젤오염토양을 사용하였으며 초기 오염농도는 $2,828{\pm}206\;mg/kg$으로 토양환경보전법상 가지역 우려기준 농도를 5배 이상 초과하였다. 세척공정의 기본 운전인자들에 대한 조건별 효율성 평가 및 최적조건 도출실험을 수행한 결과 효율적인 세척을 위하여 impeller는 편심 및 기울어진 중심에 위치하는 것이 가장 유리하였으며 교반속도는 높은 전단력(shear force)이 발생하는 고속교반조건(300 rpm)에서 세척효율이 가장 우수하였다. 교반시간은 10분이 효율성 및 경제성이 우수한 조건으로 판단되었으며 1차 반응속도식에서 도출된 교반속도별 속도상수들간 증가율 감소를 확인하여, 저속 교반조건(30, 60 rpm)에서도 추가적인 물리적 탈착력이 더해진다면 고속교반조건에서와 같은 제거효율을 얻을 수 있음을 알 수 있었다. 고압공기 분사에 따른 세척효율은 소수성(hydrophobic)의 토양표면 유류물질이 수중의 공기방울 표면에 강하게 부착(attracting)되어 제거됨을 확인하였고 공기압이 높아질수록 반응기내 공기유량이 증가되면서 오염물질의 부착율이 향상되었다. Impeller에 의한 교반과 고압공기 분사 혼합공정에서는 60 rpm, $2\;kg/cm^2$ 조건이 가장 효율적으로 판단되었다. 따라서 고압공기분사를 통한 토양세척기법은 유류오염토양 정화에 효율적 적용이 가능할 것으로 사료된다.