• Title/Summary/Keyword: Oil Duct

Search Result 39, Processing Time 0.025 seconds

A Research on the Optimization of Turbocharging System in a Medium Speed Diesel Engine (중형 디젤엔진의 터보챠저 과급 시스템 최적화에 관한 연구)

  • Youn Wook-Hyun;Gal Sang-Hak;Ha Ji-Soo;Kim Ho-Ick;Kim Ju-Tae;Kim Ki-Doo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.7
    • /
    • pp.1138-1144
    • /
    • 2004
  • In order to improve engine performance while overcoming the weak points of Pulse and MPC(Modular Pulse Converter) turbocharging system, a new turbocharging system. "Hi-Pulse system", has been introduced and developed for medium speed diesel engine. HYUNDAI HiMSEN engines. Hi-Pulse system is to utilize not only the benefits of MPC system at higher load but also the ones of Pulse system at lower load. As for the results. the specific fuel oil consumption and NOx emission were lowered compared with the Pulse and MPC system. Performance simulation were carried out to optimize intake and exhaust timing and exhaust duct arrangement and to improve the performance of Hi-Pulse system engine.em engine.

Numerical Study on Surface Air-Oil Heat Exchanger for Aero Gas-Turbine Engine Using One-Dimensional Flow and Thermal Network Model (항공기 가스터빈용 오일쿨러 해석을 위한 1 차원 열유동 네트워크 수치적 모델 개발 및 연구)

  • Kim, Young Jin;Kim, Minsung;Ha, Man Yeong;Min, June Kee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.11
    • /
    • pp.915-924
    • /
    • 2014
  • In an aero gas-turbine engine, a surface air-oil heat exchanger (SAOHE) is used to cool the oil system for the gearboxes and electric generators. The SAOHE is installed inside the fan casing of the engine in order to dissipate the heat from the oil system into the bypass duct stream. The purpose of this study was to develop an effective numerical method for designing an SAOHE for an aero gas-turbine engine. A two-dimensional model using a porous medium was developed to evaluate the aero-thermal performance of the fins of the heat exchanger, and a one-dimensional flow and thermal network program was developed to save time and cost in the evaluation of the heat exchanger performance. Using this network program, the pressure drop and heat transfer performance of the heat exchanger were predicted, and the results were compared with two-dimensional computational fluid dynamics results and experiment data for validation.

A Study on the Spontaneous Ignition of the Fuel Injected into a Hot Air Stream - Additional Report: Utilization of Diesel Oil and Emulsified Fuel- (高溫空氣流 에 噴射한 噴霧 의 自然燃燒 에 관한 硏究 -속보 : 경유 및 유화핵연료 사용-)

  • 방중철;태전간랑
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.627-637
    • /
    • 1985
  • The combustion process and the performance of a diesel engine are seriously affected by the ignition delay period of the fuel used. Some methods for improving the combustion process in the engine cylinder are to well match the strength of air swirl with the space of sprays in the cylinder, to blend an ignition improver in the fuel, to inject a small amount of auxiliary fuel prior to main injection and so on. Recently, the improvement of fuel economy and the reduction of exhaust smoke and NO have been successfully achieved by supplying diesel engines with emulsified fuel. However, it is very difficult to know real combustion mechanism under such special conditions, because of many factors affecting on the combustion process in practical reciprocating engine. In the present paper, the combustion processes of diesel fuel and emulsion fuel were tried to improve and to observe by making contact with various lean pre-mixtures in the hot air stream duct. This hot air stream method has an advantage that the spontaneous combustion process can be observed under a simplified condition.

Effects of 3,5,3'-triiodo-L-thyronine (T3) Immersion on Development of Fertilized Egg and Newly Hatching Larva of Black Seabream, Acanthopagrus schlegeli (감성돔, Acanthopagrus schlegeli 수정란과 부화자어의 발달에 미치는 3,5,3'-triiodo-L-thyronine (T3)의 침지처리 효과)

  • 강덕영
    • Journal of Life Science
    • /
    • v.13 no.1
    • /
    • pp.34-41
    • /
    • 2003
  • The hatching of fertilized egg and early development of larval black seabream, Acanthopngrus schlegeli by immersion of 3,5,3'-triiodo-L-thyronine ($T_3$) with doses of 0.01~0.5 ppm in tank were examined for early development periods and compared with control fish immersed by 0.1 N NaOH and 99% alcohol. Larvae were fed with rotifers for first 5 days during experimental period. Yolk absorption of larvae from $T_3$ immersion groups were significantly faster than that of control. Although hatching times among each groups were not significant difference. the hatching rates of larvae in higher doses (0.1 ppm and 0.5 ppm $T_3$ groups) were significantly lower than control. The results of $T_3$ immersion experiments to newly hatching larvae indicated that exogenous $T_3$induced significant faster the absorption of yolk and oil globule, faster the development of myotome and digestive duct and higher the growth rate of larvae than larvae of control. These results indicate that $T_3$ immersion supplements appear to confer a distinct advantage to eggs and larvae of black seabream, which is in early fragile developmental stage.

The Design and Performance Test of Mold Transformer for Outdoor Pole (50 kVA 주상용 몰드변압기의 설계 및 특성평가)

  • Cho, Han-Goo;Lee, Un-Yong;HwangBo, Kuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.132-137
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. In this paper, the temperature distribution of 50 kVA pole mold transformer for power distribution are investigated by FEM program and the temperature rise test of designed mold transformer carried out and test result is analyzed compare to simulation data. In this result, the designed mold transformer is satisfied to limit value of temperature and the other property is good such as voltage ratio, winding resistance, no-load loss, load loss, impedance voltage and percent regulation.

  • PDF

The Energized Aging Property of Pole Mount Mold transformer by Back-to-back Method (반환부하법에 의한 옥외 주상용 몰드변압기의 과전열화 특정)

  • Hwang, Bo-Guk;Cho, Han-Goo;Lee, Un-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.484-487
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. In this paper, the proto type mold transformer of 50kVA class is investigated by routine, type, special test. The outdoor energized aging test is investigated by back-to-back method to verify the long time performance of pole mold transformer. The aging process of transformer is analyzed by various diagnosis method such as DC voltage-current test, $tan{\delta}$, Meggar measurement, winding temperature and etc.

  • PDF

Effect of Cyclohexane Treatment on the Liver Damage in CCl4-Pretreated Rats (CCl4전처치한 흰쥐에 Cyclohexane 투여가 간손상에 미치는 영향)

  • 윤종국;김현희
    • Toxicological Research
    • /
    • v.19 no.2
    • /
    • pp.105-114
    • /
    • 2003
  • TO evaluate an effect of cyclohexane treatment on the degree of liver damage, rats were induced liver damage with 10 or 17 times $CCl_4$ injection (0.1 m1/100 g body wt., 50% $CCl_4$ dis-solved in olive oil) at intervals of every other day. Cyclohexane (1.56 g/kg body wt., i.p.) was administrated to the animals at 48 hours after the last pretreatment of $CCl_4$ . Rats were sacrificed at 4 hours after injection of cyclohexane. On the basis of histopathological findings, liver weight/body weight (LW/ BW, %), activities of serum alanine aminotransferase (ALT), xanthine oxidase (XO) and akaline phosphatase (ALP), and contents of liver protein and manlondialdehyde (MDA), $CCl_4$ -pretreatment induced liver damage. And $CCl_4$ 17 times treated group showed more severe liver damage than $CCl_4$ 10 times treated group. Administration of one dose of cyclohexane to $CCl_4$ 10 times treated animals resulted in the enhanced liver damage; liver necrosis with proliferation of fibroblast and bile duct abnormality, and increase in hepatic MDA content and the activities of serum ALP and ALT, But the enhanced liver damage was not found in $CCl_4$ 17 times treated animals. Serum cyclohexanone concentrations at 4 or 8 hours after injection of cyclohexane were higher in all liver damaged groups than normal group and were somewhat higher In $CCl_4$ 17 times treated animals than $CCl_4$ 10 times treated ones. Among the oxygen free radical metabolizing enzymes, hepatic cytochrome P45O dependent aniline hydroxylase (CYPdAH) activity in cyclohexane metabolizing enzyme system was meaningfully increased by the injection of cyclohexane to the liver damaged rats, with increased Vmax and high affinity to aniline. LW/BW (%) and activities of serum XO and ALT were more significantly increased in liver damaged groups than normal group by administration of cyclohexanone. In conclusion, it is assumed that an enhancement of liver damage by injection of one dose of cyclohexane to liver damaged animals might be caused by oxygen free radicals and cyclohexanone.

Direct Action of Relaxin on the Pig Mammary Glands to Promote Development of the Alveoli and Remodeling of the Extracellular Matrix (Relaxin Hormone의 직접젇인 작용에 의한 돼지 유선상피세포의 발달과 세포외간 기질의 분해개조 촉진)

  • Min, G.S.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.4
    • /
    • pp.585-592
    • /
    • 2004
  • Our previous studies demonstrated that relaxin in concert with estrogen promotes development of the mammary parenchyma during the last third of gestation in gilts, and the specific relaxin-binding sites were present in the mammary gland. This study was conducted to determine if relaxin-binding sites in the mammary gland were functional relaxin receptors. Three cycling cross-bred gilts were bilaterally ovariectomized on day 0 of the experiment. Beginning on day 15 and continuing through day 29 post-surgery, the gilt received an im. injection of estradiol benzoate at 12-hr intervals. Beginning on day 22 post-surgery, highly purified porcine relaxin was administered(lug/hr) into the left fourth mammary gland from the anterior end via miniature osmotic pump. Physiological saline was administered to the right fourth mammary gland. The gilt was sacrificed on day 29 post-surgery and histological characteristics of the mammary parenchyma were examined. The mammary glands treated locally with saline showed little, if any, lobulo-alveolar development, whereas the mammary glands treated with relaxin showed not only marked lobulo-alveolar development but also prominent secretions in the alveoli. The saline-treated glands were characterized by relatively dense and highly organized collagen fiber bundles. Whereas, in the relaxin-treated mammary glands, collagen fiber bundles were dispersed and loosely organized. In conclusion, relaxin-binding sites in the mammary gland are functional relaxin receptors and relaxin acts directly on the pig mammary gland to promote development of the alveoli and remodeling of the extracellular matrix.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 - (공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF