The Characteristics of Discharging signal in various kinds of insulation oil using Optical Fiber Sensor (광섬유 센서로 측정한 절연유에 따른 방전신호 특성)

  • Kim, Tae-Young;Nam, Jin-Ho;Suh, Kwang-S.;Kim, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1599-1601
    • /
    • 1999
  • The characteristics of ultrasonic signal in insulation oil were investigated by optical fiber sensor(OFS) utilizing Mach-Zehnder interferometer. For checking the response properties of OFS ultrasonic signal was generated by function generator in various kinds of insulation oil. The attenuation of ultrasonic signal linearly increased with the increase of viscosity of insulation oil in log scale. Discharging signal was produced by neele-sphere electrode system. Intensity of discharging signal was plotted in terms of cumulative $y^2$ and the intensity of discharging signal in new oil was little bigger than that in serviced one.

  • PDF

Analysis of Discharged Oil Using Visualization Technique for Upper Part and Discharging Pipe of Rotary Compressor (로터리 압축기 상부 및 토출관 가시화에 의한 토유 오일 분석)

  • Cho, Pil-Jae;Sung, Chun-Mo;Shin, Chang-Joo;Ko, Han-Seo
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.570-575
    • /
    • 2005
  • An efficiency of a refrigeration cycle and a reliability of a compressor can be reduced if a refrigerant including excessive lubricating oil is exhausted from a rotary compressor. Thus, the oil behavior inside the compressor should be analyzed to improve the efficiency. A tested rotary compressor has been manufactured with visualization windows at upper parts in this study to investigate the oil behavior using developed visualization techniques. Discharge pipe with level gage has been visualized to investigate discharged oil amount. The oil behaviors inside the compressor and discharging pipe at various operating conditions have been analyzed. The results of the visualization for the discharging pipe have been compared with those of the upper part to confirm the accuracy.

  • PDF

A Study on the Effect of Pressure upon A.C Partial Discharge in Insulating Oil (제어유의 문류품분효전에 미치는 형력의 영향)

  • Sang-Hoon Kook
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.32 no.7
    • /
    • pp.227-233
    • /
    • 1983
  • Noticing that action of gaseous phase in insulating oil concerns to the discharging characteristics, I investigated the smalness pressure effects on quantity of the partial discharge and discharging pulse frequency. Tests are carried out between the niddle points in insulating oil at pressure being changed by gradual charge of inert gas Ar. At pressure as low as of 0.1-0.5 torr pulse frequency and maximum partial discharge reach peak while at pressure haigher than 20 torr no pulse is observed. The fact that pulse frequency has peak value at certain presure, which is changed either by charging Ar or by adding oil, implies that the action of gaseous phase depends on pressure. Test results are that partial discharge pulse are governed by pressure of Ar-charged oil, and less partial discharge pulses correspond to smaller bubbles whereas more partial descharge pulses correspond to larger bubbles.

  • PDF

Diagnosis for Degradation of Transformer Oil by an Optical Fiber Sensor (광섬유 센서를 이용한 변압기 절연유의 열화 진단)

  • Yi, Sue-Muk;Kim, Tae-Young;Suh, Kwang-S.;Sung, Man-Young
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1563-1565
    • /
    • 2000
  • This paper presents the preliminary results on the application of optical fiber sensor(OFS) for the diagnosis of degradation in the transformer oil. An OFS system using a Mach-Zehnder interferometry technique was built to detect attenuation of acoustic signal produced by discharging. With increasing the number of discharging in the insulation oil, the attenuation of acoustic signal became greater. A strong correlation between electrical and acoustic signal intensities from discharge generated in the transformer oil was confirmed by the results reported here.

  • PDF

A Study on Cargo Ships Routing and Scheduling Emphasis on Crude Oil Tanker Scheduling Problems (배선 및 선박운항일정계획에 관한 연구 -유조선의 운항일정계획을 중심으로-)

  • Hugh, Ihl
    • Journal of the Korean Institute of Navigation
    • /
    • v.14 no.1
    • /
    • pp.21-38
    • /
    • 1990
  • This paper discusses the various modes of operations of cargo ships which are liner operations, tramp shipping and industrial operations, and mathematical programming, simulation , and heuristic method that can be used to solve ships routing and scheduling problems for each of these operations. In particular, this paper put emphasis on a crude oil tanker scheduling problem. The problem is to achieve an optimal sequence of cargoes or an optimal schedule for each ship in a given fleet during a given period. Each cargo is characterized by its type, size, loading and discharging ports, loading and discharging dates, cost, and revenue. Our approach is to enumerate all feasible candidate schedate schedules for each ship, where a candidate schedule specifies a set of cargoes that can be feasibly carried by a ship within the planning horizon , together with loading and discharging dates for each cargo in the set. Provided that candidate schedules have been generated for each ship, the problem of choosing from these an optimal schedule for each ship is formulated as a set partitioning problem, a set packing problem, and a integer generalized network problem respectively. We write the PASCAL programs for schedule generator and apply our approach to the crude oil tanker scheduling problem similar to a realistic system.

  • PDF

An Analyse for Solidified Accident of Nile Blend Crude Oil (히팅카고 응고사고 분석 - 나일브렌드를 중심으로 -)

  • 김영모;이옥용
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.8 no.2
    • /
    • pp.79-86
    • /
    • 2002
  • A heating cargo is solidified by several reasons during carriage. This study is to analyse a cargo accident which 811,202 US barrels of Nile Blend crude oil reamined solid In the tanks after discharge. There are some possibilities that low temperature of Beading cargo below cloud point and wax appearance temperature at loading time, heating interruption during voyage or discharging, and prohibition of crude oil washing during discharging might influence the cargo solidified. But we concluded that the defect of heating system would most affect the heating cargo solidified locally, and which blocked drain hole of bottom transverse and web frame and they obstruct flow of heating cargo in the tanks.

  • PDF

A Study on Flow Characteristics in Lubrication System of Manual Transmission in a Commercial Vehicle (상용차용 수동변속기 윤활시스템의 유동특성에 관한 연구)

  • Yun, Ji-Hun;Yi, Chung-Soeb;Suh, Jeong-Se;Song, Chul-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.2
    • /
    • pp.40-46
    • /
    • 2012
  • In this study, numerical analysis was conducted to understand the flow characteristics of lubrication system in a manual transmission installed in a commercial vehicle. Also, the analysis was conducted with the purpose of improving the heat and lubricative condition of the transmission. Discharging flow rates on each oil hole outlet according to various engine rotating speed and the length of oil hole branch was calculated. In conclusion, as engine rotating speed is high and the length of oil hole branch is long, the discharging flow rate is high by virtue of the centrifugal force. In addition, this study proposed data for optimal design of lubrication system in manual transmission for a commercial vehicle.

An Analyse for Solidified Accident of Nile Blend Crude Oil (히팅카고 응고사고 분석 - 나일브렌드를 중심으로 -)

  • 김영모;이옥용
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2002.10a
    • /
    • pp.59-70
    • /
    • 2002
  • A heating cargo is solidified by several reasons during carnage. This study is to analyse a cargo accident which 811, 202 US barrels of Nile Blend crude oil reamined solid in the tanks after discharge. There are some possibilities that low temperature of loading cargo below cloud point and wax appearance temperature at loading time, heating interruption during voyage or discharging, and prohibition of crude oil washing during discharging might influence the cargo solidified. But we concluded that the defect of heating system would most affect the heating cargo solidified locally, and which blocked drain hole of bottom transverse and web frame and they obstruct flow of heating cargo in the tanks.

  • PDF

Development of a Low Noise and High Efficiency Rotary Compressor by a New Muffler (신규 저소음 및 고효율 머플러 적용 회전식 압축기 개발)

  • Jarng, In-Sun;Kim, Bong-Jun;Youn, Young;Sung, Choon-Mo;Lee, Seung-Gap
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.533-539
    • /
    • 2004
  • The rotary compressor is widely used for the air conditioner because it is efficient and compact. In recent, the need for silent and efficient compressors is much stronger than the past. The new type muffler was invented to reduce noise level and to improve efficiency. The new type muffler that has two side discharge holes and dome shape represents much lower overall noise level, especially noise levels around 1kHz than the old type one that has one center discharge hole In acoustic spectra. Also it has higher air conditioner efficiency by lower oil discharging amount of a compressor than old type one that has rectangular shape and two side discharge holes. The noise reduction and efficiency improvement effects of the new type muffler were verified by tests for rotary compressors and air conditioners.

  • PDF

Optimal Charging and Discharging for Multiple PHEVs with Demand Side Management in Vehicle-to-Building

  • Nguyen, Hung Khanh;Song, Ju Bin
    • Journal of Communications and Networks
    • /
    • v.14 no.6
    • /
    • pp.662-671
    • /
    • 2012
  • Plug-in hybrid electric vehicles (PHEVs) will be widely used in future transportation systems to reduce oil fuel consumption. Therefore, the electrical energy demand will be increased due to the charging of a large number of vehicles. Without intelligent control strategies, the charging process can easily overload the electricity grid at peak hours. In this paper, we consider a smart charging and discharging process for multiple PHEVs in a building's garage to optimize the energy consumption profile of the building. We formulate a centralized optimization problem in which the building controller or planner aims to minimize the square Euclidean distance between the instantaneous energy demand and the average demand of the building by controlling the charging and discharging schedules of PHEVs (or 'users'). The PHEVs' batteries will be charged during low-demand periods and discharged during high-demand periods in order to reduce the peak load of the building. In a decentralized system, we design an energy cost-sharing model and apply a non-cooperative approach to formulate an energy charging and discharging scheduling game, in which the players are the users, their strategies are the battery charging and discharging schedules, and the utility function of each user is defined as the negative total energy payment to the building. Based on the game theory setup, we also propose a distributed algorithm in which each PHEV independently selects its best strategy to maximize the utility function. The PHEVs update the building planner with their energy charging and discharging schedules. We also show that the PHEV owners will have an incentive to participate in the energy charging and discharging game. Simulation results verify that the proposed distributed algorithm will minimize the peak load and the total energy cost simultaneously.