• Title/Summary/Keyword: Office buildings

Search Result 619, Processing Time 0.05 seconds

The Impact of Double-Skin Façades on Indoor Airflow in Naturally Ventilated Tall Office Buildings

  • Yohan, Kim;Mahjoub M. Elnimeiri;Raymond J. Clark
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.2
    • /
    • pp.129-136
    • /
    • 2023
  • Natural ventilation has proven to be an effective passive strategy in improving energy efficiency and providing healthy environments. However, such a strategy has not been commonly adopted to tall office buildings that traditionally rely on single-skin façades (SSFs), due to the high wind pressure that creates excessive air velocities and occupant discomfort at upper floors. Double-skin façades (DSFs) can provide an opportunity to facilitate natural ventilation in tall office buildings, as the fundamental components such as the additional skin and openings create a buffer to regulate the direct impact of wind pressure and the airflow around the buildings. This study investigates the impact of modified multi-story type DSFs on indoor airflow in a 60-story, 780-foot (238 m) naturally ventilated tall office building under isothermal conditions. Thus, the performance of wind effect related components was assessed based on the criteria (e.g., air velocity and airflow distribution), particularly with respect to opening size. Computational fluid dynamics (CFD) was utilized to simulate outdoor airflow around the tall office building, and indoor airflow at multiple heights in case of various DSF opening configurations. The simulation results indicate that the outer skin opening is the more influential parameter than the inner skin opening on the indoor airflow behavior. On the other hand, the variations of inner skin opening size help improve the indoor airflow with respect to the desired air velocity and airflow distribution. Despite some vortexes observed in the indoor spaces, cross ventilation can occur as positive pressure on the windward side and negative pressure on the other sides generate productive pressure differential. The results also demonstrate that DSFs with smaller openings suitably reduce not only the impact of wind pressure, but also the concentration of high air velocity near the windows on the windward side, compared to SSFs. Further insight on indoor airflow behaviors depending on DSF opening configurations leads to a better understanding of the DSF design strategies for effective natural ventilation in tall office buildings.

A Study on Architectural Design Factors for Tall Office Buildings with Regional Climates based on Sustainability

  • Cho, Jong Soo
    • Architectural research
    • /
    • v.7 no.2
    • /
    • pp.13-21
    • /
    • 2005
  • Throughout history, buildings have been interrelated with certain indigenous characteristics such as regional climate, culture and religions. In particular, the control of regional climate has been primarily a concern for compatibility with nature. In our modern age, technologies to control climate have been successfully developed in architecture but the consumption of large quantities of natural resources can also produce environmental problems. This study is based on the proposition that this negative trend can be minimized with architectural design that is motivated to coexist with a regional climate. This study develops these design strategies for tall office buildings by analyzing various combinations of building design configurations based on regional climates. The objective is to determine the optimum architecture of tall office buildings during the initial design process that will reduce energy consumption for regional climatic conditions. The eQUEST energy simulating program based on DOE-2.2 was used for this comparative analysis study of the energy use in tall office buildings based on architectural design variables and different regional climates. The results are statistically analyzed and presented in functional architectural design decision-making tables and charts. As a result of the comparison of architectural design consideration for tall office buildings in relation to regional climates, buildings physically need less energy consumption when the architecture is concerned with the regional climate and it produces a more reasonable design methodology. In reality, imbalanced planning which is architectural design's lack of regional characteristics requires additional natural resources to maintain desired comfortable indoor conditions. Therefore, the application of integrated architectural design with regional nature should be the first architectural design stage and this research produces the rational. This architectural design language approach must be a starting point to sustaining long-term planning.

User Evaluation of Common Spaces in Office Building - Focused on Universal Design - (오피스 건물의 공용공간 디자인에 대한 사용자 평가 - 유니버설 디자인을 중심으로 -)

  • Oh, Chan-Ohk
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.1
    • /
    • pp.20-29
    • /
    • 2012
  • The study was intended to evaluate common spaces of office building in view point of universal design. The common spaces were access road, main entrance, parking lot, corridor, and restroom. Two office buildings in Centum city of Busan were evaluated by their workers, each 100 ones. The check list for evaluating them consisted of 36 universal design elements which related to five common spaces. First, there were many universal design elements which need to be improved. Second, among five common spaces, restroom has the most elements to be rated low. First of all, at least one restroom for wheelchair should be provided each floor. Third, even though both of two office buildings were recently built, there were significant difference between their users' evaluations. This implies that the concept of universal design is not applied to office buildings well. Fourth, there were significant difference among users' evaluations according to age, especially in case of design related elements. This means that users' age is an important factor to be considered.

  • PDF

Planning Organizations and Planning Process of To(道) and Pu(府) Government Office Buildings under the Rule of Japanese Imperialism (일제강점기 도청사.부청사의 설계주체와 설계과정)

  • Kim, Myung-Sun
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.2
    • /
    • pp.102-109
    • /
    • 2011
  • Under the rule of Japanese Imperialism, there were two kinds of architectural government organizations inside the Chosun(朝鮮) Governor-General which designed To(道) and Pu(府) government office buildings; one was the organization inside the central government office and the other inside the local government offices(To and Pu). By the administrative approval procedure of the Chosun Governor-General, the local architectural organization planned site and floors of the building in the schematic design stage, and in the detail design stage not only the central but sometimes the local planned the building design. The design accomplished by the local in schematic stage was believed as a kind of guideline in detail design and the local organization was able to insist their own needs to the central and to change the central's planning. Even though the central had the authority of the design, the local took part in the planning of To and Pu government office buildings at least in the schematic design stage.

A Study on the Plannig Characteristics & Improvement of Citizen Cultural Space in Public Building in terms of Cultural Administration - Focused on the Cases Since 2000's - (문화행정의 관점에서 본 공공청사 시민문화공간 공간계획 특성 및 개선방안에 관한 연구 - 2000년 이후의 사례를 중심으로 -)

  • Kang, Eun-Jin;Choi, Sang-Hun
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.2
    • /
    • pp.174-181
    • /
    • 2014
  • The purpose of the study for this thesis is to look into the status and issues of government office buildings since the self-government policy through comparing and analyzing government office buildings, between domestically and to provide improvement plans of the citizen cultural space and with the self-government budget, enhance the utility and efficiency of the government office buildings and to take a role of a reference in the future when citizen cultural space is formed in the government office buildings. As the result of the study, the space planning characteristics of government office building's citizen cultural space in terms of cultural administration is as follows. First, percentage of room to strengthen the sense of community is small. Therefore, the place where residents can argue there is a need. Second, it is necessary to expand the venue and art collection that are missing in public government buildings. Third, since the lecture room for lack of civic education, it should be taken into account when making cultural space for the citizens. Fourth, thread observatory and souvenir shops, providing information is not enough, it is to be further expanded. Fifth, rented facility for public is hall be provided with a diversity.

Forecasting and Prolonging Method of Optimum Economic Life for Office Buildings using Life Cycle Cost (LCC분석에 의한 오피스건축물의 최적경제수명추정분석 및 장수명화에 관한 연구)

  • Yang Bong-Seog;Jeong Hee-Cheol;Kim Kyung-Rai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.2 no.4 s.8
    • /
    • pp.135-143
    • /
    • 2001
  • The purpose of this study is to estimate and analyze the optimum economic life of office buildings in consideration of their LCC (Life Cycle Cost), and thereby, explore the ways to manage the outlived office buildings economically. In estimating the economic life, initial investment cost and maintenance cost are taken into due consideration. For this study, those office buildings in Yeouido and Mapo region were sampled. The surveyed details were reduced to unit area to calculate a unit value, and then, their optimum economic life was estimated using LCC. Five alternatives for management of outlived office buildings were compared in terms of reconstruction or rehabilitation cost.

  • PDF

Failure of Earth Leakage Breaker and Power Quality Analysis in Office Buildings (사무용 빌딩에서의 누전차단기 오동작과 전력품질 분석)

  • Lee, Sang-Ick;Yoo, Jae-Geun;Jeong, Jong-Wook;Lim, Yong-Bae;Jeon, Jeong-Chay
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.211-216
    • /
    • 2004
  • This paper presented a actual conditions on a false-tripping of ELB(Electrical Leakage Breaker) and an assessment of the harmonics due to non-linear electronic equipment such as personal computers, printers, fax machines, and test equipments in several office buildings. Actual conditions on a failure of ELB were surveyed and analyzed by making up a question to safety managers of in office buildings. Also, power quality measurements such as harmonic currents, voltage and current waveforms and current imbalance were made at various office buildings where nuisance tripping of ELB is often occurred. The results of this study can be used in making decisions regarding cause of ELB trip and operating md tripping characteristics test of ELB when subjected to distorted current waveforms.

  • PDF

Recommended Practice for Demand Factor by Feature Parameters and Regression Analysis depending on Power Consumption Characteristics in Office Buildings (사무소용빌딩의 전력소비특성을 고려한 특징파라메터 및 회귀분석을 통한 조명 및 일반동력부하의 수용률 분석)

  • Kim, Se-Dong;Nam, Ki-Beom;Jung, Hyung-Yong;Shin, Hwa-Young;Kim, Sung-Hwan
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.331-336
    • /
    • 2005
  • It is increased electrical energy consumption with the development of intelligence society in the office buildings and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design demand factor in office buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 54 office buildings and 34 electrical design offices. In this dissertation, it is necessary to analyse the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried linear and nonlinear regression analysis.

  • PDF

Recommended Practice for Demand Factor and Maximum Utilization Factor by Feature Parameters and Regression Analysis depending on Power Consumption Characteristics in Office Buildings (사무소용빌딩의 전력소비특성을 고려한 특징파라메터 및 회귀분석을 통한 수용률과 변압기최대이용률 비교 분석)

  • Kim, Se-Dong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.241-244
    • /
    • 2007
  • It is increased electrical energy consumption with the development of intelligence society in office buildings and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design demand factor in office buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 132 office buildings. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried linear and nonlinear regression analysis.

  • PDF

Analysis of the Building Energy Efficiency Rating Certified for Public Office Buildings (공공기관 업무용 건물의 건축물에너지효율등급 인증 현황 분석)

  • Lee, Han-Sol;Kim, Seo-Hun;Kim, Jonghun;Kim, Jun-Tae;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.75-82
    • /
    • 2015
  • Purpose: The first grade of Korea's Building Energy Efficiency Rating System(BEERS) is required for new government office buildings as a mandatory measure to reduce greenhouse gas emission. However, there is no specific criteria about performance that which level should apply to energy-saving design element for obtaining Building Energy Efficiency Rating 1st grade. Therefore, Certification status should be analyzed firstly, about the office building which is certificated. Certification analysis for office buildings acquired certification therefore should be done first. Method: In this study, Certification status(Office buildings acquired Building Energy Efficiency Rating Certification)was analyzed by classified year, region, specific scale etc. And we analyzed statistically by eliciting an average value of each element influencing to the amount of energy. Result: Energy demands were gradually decreased due to revision of thermal insulation standards for enhanced u-value. Energy consumptions were different from the kind of equipment and yearly trends applied depending on the size of the building. Total primary energy consumptions were influenced by heat source types and the primary energy scale factors.