• Title/Summary/Keyword: Office Buildings

Search Result 621, Processing Time 0.03 seconds

An Experimental Study on the Improvement of Insulation Performance in Old University Buildings and Economic Evaluation (노후화된 대학 건물의 단열성능 향상 실험 및 경제성 평가)

  • Lee, Jeongmin;So, Wonho;Cho, Kyungchan;Choi, Dongnyeok;Lee, Kwon-yeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.287-297
    • /
    • 2020
  • This study examined ways of improving the internal insulation performance of aging university buildings, and to enhance the convenience of occupants in university buildings and the insulation effect of aging buildings. This research was conducted to solve the problem of continuous requests for improving the insulation performance of office workers in the Nehemiah Hall building of Handong University. The results showed that the internal temperature of Nehemiah Hall was low compared to the internal temperature of the adjacent building. Considering the characteristics of the building, the university chose insulating materials under the theme of internal insulation. The experiment was conducted by installing internal wall insulation used in the market by producing a model room that miniaturized the university professor's office. Based on the experimental results, an economic evaluation was conducted to analyze the insulation effect by measuring the heating time and actual heat transmission coefficient. An economic evaluation was conducted by experiment and theory and on a winter and summer basis. According to the research, when an Isopink (30 T) was introduced as an internal insulation material in 60 offices of Nehemiah Hall, it could save up to 1,071,600 won in total during the winter season and 109,200 won during the summer season.

A Comparison Study on the Importance and Problems of Assessment Items of the G-SEED System (G-SEED 평가항목별 중요도 및 문제점 비교연구)

  • Jang, Hyun-Sook;Lee, Sang-Ho
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.113-120
    • /
    • 2014
  • The Green growth has been demanded in all industrial sectors due to environmental destruction and exhaustion of natural resources. Buildings have consumed 1/3 of the total energy and 40% of natural resources and have accounted for 50% of $CO_2$ emissions and 30-50% of waste materials. In 1991, BREEAM(Building Research Establishment Environmental Assessment Method) of the British BRE(Building Research Establishment) had begun reduction of $CO_2$ emissions and energy saving movements, in which all the countries around the world have participated. The Republic of Korea has taken part in this trend by declaring a "National Vision in the Green Growth" in 2008 and implementing regulations on "Low Carbon, Green Growth" in 2010. G-SEED(Green Standard for Energy and Environmental Design) based on GBCS(Green Building Certification System) has been actively promoted for its application. This study has limited its scope to G-SEED office buildings. It has conducted surveys of problems and assessment items of the G-SEED identified in the preceding study by the AHP(Analytic hierarchy process) method. The purpose of this study is to conduct a comparison analysis of problems and ranking of evaluation items recognized in the survey and to be presented as reference materials for G-SEED system improvements at its next amendments.

Evaluation of Rainwater Utilization for Miscellaneous Water Demands in Different Types of Buildings Using Geographic Information System

  • Kim, Jinyoung;An, Kyoungjin;Furumai, Hiroaki
    • Environmental Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.85-90
    • /
    • 2013
  • This study is an attempt to quantify rainwater utilization and miscellaneous water demand in Tokyo's 23 special wards, the core of the urban area in Tokyo, Japan, in order to elucidate the potential of further rainwater utilization. The rainwater utilization for miscellaneous appropriate water demands, including toilet flushing, air conditioning, and garden irrigation, were calculated for six different types of building: residential house, office, department store, supermarket, restaurant, and accommodation. Miscellaneous water demands in these different types of building were expressed in terms of equivalent rainfall of 767, 1,133, 3,318, 1,887, 16,574, and 2,227 (mm/yr), respectively, compared with 1,528 mm of Tokyo's average annual precipitation. Building types, numbers and its height were considered in this study area using geographic information system data to quantify miscellaneous water demands and the amount of rainwater utilization in each ward. Area precipitation-demand ratio was used to measure rainwater utilization potential for miscellaneous water demands. Office and commercial areas, such as Chiyoda ward, showed rainwater utilization potentials of <0.3, which was relatively low compared to those wards where many residential houses are located. This is attributed to the relatively high miscellaneous water demand. In light of rainwater utilization based on building level, the introduction of rainwater storage mechanisms with a storage depth of 50 mm for six different types of buildings was considered, and calculated as rainfall of 573, 679, 819, 766, 930, and 787 (mm), respectively. Total rainwater utilization using such storage facilities in each building from 23 wards resulted in the retention of 102,760,000 $m^3$ of water for use in miscellaneous applications annually, and this volume corresponded to 26.3% of annual miscellaneous water demand.

A Study on the Evacuation Performance Review for the Office Buildings (업무용 빌딩의 피난 성능 검토에 관한 연구)

  • 오혁진;백승태;김우석;이수경
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.1-6
    • /
    • 2003
  • In this study, it reviewed about evacuation performance of a specified Office Building. assessment tools is FAST 3.1.7 (Estimation of Flash Over, Estimation of Layer Height Down Flow Time), SIMULEX 32-bit (Estimation of Evacuation Time), JASMINE 3.25d. (Smoke Flow Assessment of a specified time) Result from Fire Scenario # 1, Flash Over is not generated in Compartment. Evacuation Time is estimated 25.2 sec by SIMULEX 32-bit. layer height until this time (25.2 sec) was estimated 2.4 m by FAST 3.1.7. After ignition until this time (25.2 sec), smoke was not release to the a corridor. In consequence, We concluded that people in building are completing the safe evacuation without the damage of smoke. Result from Fire Scenario # 1, Flash Over generated 6 min 33.2 sec in Compartment. Evacuation Time is estimated 1 min 25.5 sec by SIMULEX 32-bit. layer height down flow time is 1 min 40.8 sec by FAST 3.1.7 and 5 min 23 sec by theoretical calculation. Also, total building evacuation time was estimated 2 min 26.6 sec. After ignition until this time (2 min 26.6 sec), smoke released to the a corridor but it amount was few little. Therefore, generated smoke in compartment not effected to the people in buildings.

An Economic Evaluation Study of Office Remodeling and Green-remodeling Projects : A Simulation Approach to a Rental Office in GBD, Seoul (생애주기를 고려한 오피스 건물의 리모델링과 그린리모델링의 경제성 평가 연구 : 서울시 강남업무지구의 임대오피스 사례)

  • Lee, Seong-Ho;Lee, Jae-Su
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.3
    • /
    • pp.23-34
    • /
    • 2018
  • Due to a waste of energy in korea, about 525,000 which are 75 percent of total buildings are at least 15 years old buildings that need remodeling. There are two current remodeling systems. One is a remodeling system to reduce a waste of resources from the reconstruction. The other is a green-remodeling system aimed to energy savings and reducing environmental costs. This study is to analyze quantitatively these current systems with respect to the cost-benefit caused by the life cycle and suggests the political and institutional implications through the interpretation of the results. For a quantitative analysis, we analyzed reducing maintenance costs and rent benefits with simulation by using opportunity costs, construction costs, plan costs and supervision costs as expense variables and using the reduced floor area ratio, institutional incentives, energy, water resources and certified emission reduction(CER) as benefit variables. As a result of the empirical study, the green-modeling was more beneficial in the field of environment such as the energy savings, however, the final benefits of remodeling which has no green building certification costs but more floor area ratio incentives were more economical. The green-remodeling system focused on reducing environmental costs and energy savings needs a equatable institutional incentive system.

Evaluation of Thermal and Visual Environment for the Glazing and Shading Device in an Office Building with Installed of Venetian Blind (베네시안 블라인드가 적용된 오피스 건물의 외피 투과체 계획을 위한 열·빛 환경 평가에 대한 연구)

  • Kim, Chul-Ho;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.101-109
    • /
    • 2015
  • Purpose: Glazing and shading devices influence a lot on the thermal and visual environment in office buildings. Solar heat and daylight are contrary concept, therefore proper arrangement of thermal and optical performance is needed when designing a glazing and shading devices. The purpose of this study is to examine the conditions of the glazing and shading devices available for promoting the reduction of cooling loads + lighting loads and the improvement in thermal comfort and visual comfort for the summer season in an office building installed with venetian blind. Method: This study established 12 simulation cases which have different glazings and the positions of venetian blind for evaluating different thermal and optical performance. And by using EnergyPlus v8.1 and Window v7.2 program, we quantitatively analyzed cooling loads + lighting loads, thermal comfort and visual comfort in an office building installed with the glazing and shading devices. Result: Consequently, Case 9(Double Low-E+Exterior Blind) is the best arrangement of solar heat gain and daylight influx, thereby becomes the most excellent case of reducing cooling+lighting loads(46.8%) and simultaneously becomes the enhancement case in thermal comfort. Also, DGI(Daylight glare index) under clear sky conditions in summer was evaluated to be 19.6, and thereby satisfied the recommendation level of allowing visual comfort.

Role and its Spatial utilization as a Government office of the Nambyeol-gung(南別宮) after the Japanese invasion of Korea in 1592 (임진왜란(壬辰倭亂) 이후 남별궁(南別宮)의 공해적(公廨的) 역할과 그 공간 활용) - 장서각 소장 "소공동홍고양가도형"."사대부가배치도형"의 분석을 통하여 -)

  • Chung, Jung-Nam
    • Journal of architectural history
    • /
    • v.18 no.4
    • /
    • pp.43-62
    • /
    • 2009
  • No.87 Sogong-dong where is the Chosun hotel stand. There was the Nambeol-gung(south ern royal villa) which had been a reception hall for enboys of the toadied country before Hwangudan圜丘壇 being set up in the year 1897. The site of the Nambeol-gung was Gyeongjeong慶貞 princess's a lot for house in the early 15th century. But after princess's death, it occurred property dispute between her son and four daughters. As a result of the dispute, a lot and a house of all the princess's properties reverted to the government. At reverted this lot was established a big royal villa in the year 1583 and that royal villa was granted to Uian prince. The villa reverted to the government again when the Uian義安 prince was dead in 12 years old by an epidemic. After the Imjin Invasion壬辰倭亂, another houses and buildings got to be role as a palace because of all the palace in the capital was burnt down to ashes. Among others Nambeol-gung was brought into play as the royal audience chamber. As well as, the villa became brought out role as a reception hall for enboys of the toadied country instead of a damaged reception hall the Taepyong-gwan太平館. In period when the envoy didn't come, the Nambeol-gung was used to extraordinary office of government like Dogam都監. This situation is to mean that the Nambeol-gung is not the royal villa any more. Because of the Nambeol-gung was built as a royal villa, that spaces were composited like space of house and palace. But this spatial composition and spatial name were not fit to hold a ceremony of government office. After all, Nambeol-gung was used change only the spatial name conform to ceremony of office keep up the spatial composition.

  • PDF

A Study on the 'Transparency' of Office Lobbies (오피스 로비 공간에 나타난 '투명성'의 표현에 관한 연구)

  • Lee, Hyo-Chang;Ha, Mi-Kyoung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.113-118
    • /
    • 2006
  • The lobby is the space that contributes the most to conveying the first impression of an enterprise or company that is occupying a building, and enhances the quality of the urban or business environment around an office building. Transparency is the biggest change in architecture since the modern age began, and it is the most important element of the lobby expression methods. Therefore this study was an attempt to understand the expression method of transparency which is expressed in the lobby space of office buildings, and used documentary survey and field survey to analyze it. In the examination of the theoretical background of transparency to make a specific study purpose, and based on an on-the-spot probe document, an attempt was made to grasp the expression method of Visual Transparency and Phenomenal Transparency. The data collected during this investigation was studied and a correlation coefficient. A summary of the findings of this study is as follows: 1) Transparent materials does not appear often in floors. But Phenomenal Transparency material is used in the floor. 2) During the survey it was discovered that Visual Transparency was often used in the walls of each investigated building. Phenomenal Transparency materials are found less in walls than in the floors of lobbies. 3) The expression methods that appeared the most in ceilings among the Visual Transparent expression methods. In the case of Phenomenal Transparency, the highest distribution is seen in ceilings. 4) The result of the analyzation of the correlation coefficient of Visual Transparency and Phenomenal Transparency is as follows: Expression method: There is more than one expression method of transparency, 'Open Sight', 'Light Material' and 'Surface Material' methods were introduced in case of the introduction of 'Transparent Material' among Visual Transparency in office building lobby space planning. If the 'Superimposed Space' method is introduced, then the 'Ambiguous Border' or 'Dual Sight' methods are introduced.

  • PDF

Organizations and Records of Local Government Office in the 19th Century Through an Analysis on the Transition Documents in Yeongnam Region (19세기 영남지역 중기(重記)를 통해 본 지방관아의 조직과 기록물 연구)

  • Son, Ke-young
    • Journal of Korean Library and Information Science Society
    • /
    • v.48 no.2
    • /
    • pp.237-262
    • /
    • 2017
  • During the Joseon period, space, organization, and personnel were essential in order to perform the administrative work for local governance. For that reason local government records were created, managed, and stored as the results of its administration. Buildings and spaces of local government office can be divided in 3 sections such as 1) administrator's space for governance and living; 2) petty officials' administrative space; 3) granary space for store rations and grains paid as tax. Because of its grand scale, a local government office had considerably complex organizational structure. In order to survey the types and forms of local government records, focusing on six transition documents (junggi, 重記) in the 19th Century Yeongnam Region, this study selected the record type documents in the item lists of the transition documents, then, classified the record type documents which were managed by the organizations in local government offices with several types: program of items (jeolmok, 節目), list of personnel or land (an, 案), register (daejang, 大帳), certified copy (deungnok, 謄錄) and muniment (wanmun, 完文), and examined these documents.

The Field Survey of Indoor Environment of the Office Building (오피스 건물의 실내 환경 실태 조사)

  • Yang, Young Kwon;Kang, In Sung;Chung, Min Hee;Moon, Jin Woo;Park, Jin Chul
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.71-76
    • /
    • 2016
  • Purpose: This study aimed at improving the indoor environment of the office building by measuring the indoor environment and conducting a survey. Method: The measurement was conducted from January 13 to March 16 in 2012, targeting 44 sites in same office building located in Seoul, South Korea. The lists of measurement such as dry-blub temperature, relative humidity, formaldehyde (HCHO), asbestos, carbon monoxide (CO), carbon dioxide (CO2), volatile organic compounds (VOCs) and particle pollution (PM10) were measured. In addition, illuminance which belongs to light environment and noise in sound[acoustical] environment were measured respectively. Result: The buildings showed overall pleasant conditions. In terms of the thermal, air, sound, and visual environment, each measurements were satisfied with the requirements in standard, within pleasant ranges, except several sites. However, the survey results were revealed that the office workers were mostly dissatisfied with their indoor environment. Given that the measured values were mostly within standards, the results of survey might have resulted from a compensation mentality biased toward the subjects in psychological terms.