• Title/Summary/Keyword: Office Buildings

Search Result 621, Processing Time 0.028 seconds

Survey Research on Thermal Situation of Office Buildings (사무소 건축물의 단열상황에 관한 조사연구)

  • Jung, Ui In;Kim, Bong Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.3
    • /
    • pp.145-152
    • /
    • 2013
  • This study is to evaluate the thermal insulation of the curtain wall of the buildings constructed since the 1990s to the buildings currently under construction in 2011 and to provide the basic data for repairing and reinforcing and designing the thermal insulation. To this effect, the temperature difference by part was analyzed through measuring the inside and outside surface temperature of the curtain wall of the office building, and thereafter, the conditions of the thermal insulation and the thermal bridge part were examined. The result of the study is as follows; Not only in the winter season when the temperature difference between the indoor-outdoor is over $20^{\circ}C$, but also in the summer season when there is a small temperature difference, the temperature difference between the inside and outside of the frame is $2^{\circ}C{\sim}4^{\circ}C$ equally. Under such conditions as stated above, the thermal bridge occurred, which resulted from the heat flow of the steel frame part (mullion, transom), and therefore, the reinforcement of the thermal insulation is considered to be needed.

Presumption Method for Optimum Correction Rate of Total Construction Cost Using the Median based on Historical Data Analysis in Public Office Buildings (공공건축물 실적자료 분석에 따른 중위수를 활용한 총공사비의 적정보정율 추정방법)

  • Yim, Jin-Ho;Park, Jun-Mo;Kim, Ok-Kyue
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.5
    • /
    • pp.415-422
    • /
    • 2014
  • There is growing difference between a planned value and an actual cost for increasing as an risk of construction cost. A construction cost index is an alternative to redeem a problem, but it is still very difficult to reduce an actual differential as a price fluctuation. Furthermore an existing theory of a construction cost index is overly complex, and is unsuitable for using in working-level. This study suggests an optimum correction rate in respect of a total construction cost. It is analyzing the actual cost of 53 public buildings that the Public Procurement Service ordered. The objects are main processes that include architectural works, mechanical works, electrical works, telecommunication works, and service facilities. It is compared a total construction cost based on absolute error rate using the median from frequentist principle. For this, it is selected the suitable regression model and set a correction rate.

The Relation of between the Architectural and Urban Form, Microclimate Factors and Buildings Energy Consumption (도시, 건축형태 및 미기후로 인한 건축물군의 에너지 소비량의 관계)

  • Lee, Gunwon;Jeong, Yunnam;Moon, Yoon-Deok
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.10
    • /
    • pp.923-934
    • /
    • 2019
  • This study investigates correlations between the impacts of urban and building form and microclimate on the energy consumption of buildings. It applies microscopic elements such as urban form, building form and character, and microclimate as factors in the energy consumption of buildings. To this end, the energy consumption of selected buildings in Seoul in August of 2017 was analyzed. Based on microscopic elements within a radius of 500 meters of 23 Automated Weather Station (AWS) measurement points selected by the Meteorological Office of the City of Seoul. With the exception of a few elements, the urban form and character elements demonstrate a significant relation to the energy consumption of buildings. It is also found that microclimate elements such as wind speed and humidity are pertinent to the energy consumption of buildings. It is helpful in that it suggests results for establishing more effective policies and strategies for enhancing the sustainability and resilience of cities.

The Development and Application of Office Price Index for Benchmark in Seoul using Repeat Sales Model (반복매매모형을 활용한 서울시 오피스 벤치마크 가격지수 개발 및 시험적 적용 연구)

  • Ryu, Kang Min;Song, Ki Wook
    • Land and Housing Review
    • /
    • v.11 no.2
    • /
    • pp.33-46
    • /
    • 2020
  • As the fastest growing office transaction volume in Korea, there's been a need for development of indicators to accurately diagnose the office capital market. The purpose of this paper is experimentally calculate to the office price index for effective benchmark indices in Seoul. The quantitative methodology used a Case-Shiller Repeat Sales Model (1991), based on actual multiple office transaction dataset with over minimum 1,653 ㎡ from Q3 1999 to 4Q 2019 in the case of 1,536 buildings within Seoul Metropolitan. In addition, the collected historical data and spatial statistical analysis tools were treated with the SAS 9.4 and ArcGIS 10.7 programs. The main empirical results of research are briefly summarized as follows; First, Seoul office price index was estimated to be 344.3 point (2001.1Q=100.0P) at the end of 2019, and has more than tripled over the past two decades. it means that the sales price of office per 3.3 ㎡ has consistently risen more than 12% every year since 2000, which is far above the indices for apartment housing index, announced by the MOLIT (2009). Second, between quarterly and annual office price index for the two-step estimation of the MIT Real Estate Research Center (MIT/CRE), T, L, AL variables have statistically significant coefficient (Beta) all of the mode l (p<0.01). Third, it was possible to produce a more stable office price index against the basic index by using the Moore-Penrose's pseoudo inverse technique at low transaction frequency. Fourth, as an lagging indicators, the office price index is closely related to key macroeconomic indicators, such as GDP(+), KOSPI(+), interest rates (5-year KTB, -). This facts indicate that long-term office investment tends to outperform other financial assets owing to high return and low risk pattern. In conclusion, these findings are practically meaningful to presenting an new office price index that increases accuracy and then attempting to preliminary applications for the case of Seoul. Moreover, it can provide sincerely useful benchmark about investing an office and predicting changes of the sales price among market participants (e.g. policy maker, investor, landlord, tenant, user) in the future.

Distribution and Classification of Indoor Concentration of Microorganisms in Public Buildings (다중이용시설에서의 실내공기중 미생물 분포에 관한 연구)

  • Kim Yoon Shin;Lee Eun Gyu;Yup Moo Jong;Kim Key Young
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.1
    • /
    • pp.85-92
    • /
    • 2002
  • A measurement of indoor microorganism using Reuter Centrifugal Air Sampler(RCS) was undertaken during October 1991 - February 1999 and 6-Stage Cascade Air Sampler was undertaken during May 2001 - June 2001 in Seoul. Sites including book store, department store, theater, subway station, underground shopping center, hospital, office building, sports facility, and eduationa institutio were chosen to measure indoor microorganism. The results were as follows: 1. The average of total microorganism collected on the agar strip GK-A media were, in the order, subway station, hospital, underground shopping center, department store, book store, theater, sports facility, educational institution, office building in sites. The highest concentration of 711cfu/m$^3$ was found in the subway station and the lowest concentration of 44cfu/m$^3$ was found in office building. 2. The average of staphylococci collected on the agar strip GK-S media, in the order, were subway station, underground shopping center, hospital and department store, department store, theater, office building, sports facility and educational institution in sites. The highest concentration of 502cfu/m$^3$ was found in the subway station and the lowest concentration of 14cfu/m$^3$ was found in sports facility and educational institution. 3. The average of fungus collected on the agar strip GK-HS media, in the order, were underground hospital, shopping center, theater, subway station, department store, book store, sports facility, educational institution, and office building in sites. The highest concentration of 252cfu/m$^3$ was found in the hospital and the lowest concentration of 32cfu/m$^3$ was found in office building. 4. Ratio of Indoor/Outdoor, determined by site was 1.12-2.38 in total count, 1.00-2.35 in staphylococci, and 0.99-1.34 in fungus. 5. The positive results of test were 12-24% in indoor and 9-43% in outdoor. 6. By gram staining gram positive cocci were 59.9%, gram positive bacill 24.4%, gram negative bacilli 10.4%, and gram negative cocci 0.5%.

A study on the Energy resource in School Buildings with the Changes of Educational Facilities Standard (교육 시설기준 변화에 따른 학교건축물의 에너지원 변화에 관한 연구)

  • Kim, Tae-Woo;Lee, Kang-Guk;Hong, Won-Hwa
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.73-80
    • /
    • 2010
  • Since the Korean War, Korea has experienced modernization. The population increase by baby booming has asked for more space for educational facilities. In such a situation, the purpose of educational facilities was to accommodate continuously increasing students, rather than seeking for quantitative demands. In addition, in accordance with social changes, educational shifts were required. After the revision of the seventh national curriculum in education in 1997, the school buildings became varied. The design of buildings in accordance with educational curriculum has been improved, but still lack of forming comfortable environment and considering energy efficiency in school buildings. For the improvement of educational environments, educational media such as TV and computers have been provided, and energy systems, including heating and cooling systems, has been continuously increased. As a result, it appeared that energy use in school buildings and facilities has been steadily increased and that the structure of energy consumption has been also changed, especially with regard to electricity use. Living in the 21st century, human beings face global environmental issues, such as global warming, geographical climate changes, and ozone destruction that are the consequences of fossil energy use. Therefore, even in industrial areas, considering a counterplan for low energy use is being paid attention. Starting with Kyoto Protocol in 1992, people try to decrease carbon dioxide and to develop alternative energies (i.e. natural energy); for example, solar energy, wind force, terrestrial heat, and water power. Advanced countries already set up a criterion for $CO_2$ decrease ranging from office buildings to residential houses and also propose alternatives for the $CO_2$ decrease. However, there is no such a plan for low energy use and $CO_2$ decrease in school facilities, and any research on the actual conditions was not accomplished. Thus, this study examines energy demand in classrooms that take up a large portion of energy demand in school building structure.

Estimation of the Potential Area for Roof Greening in Gyeonggi-do and Its Implications (경기도의 옥상녹화 가용면적 추정과 이의 정책적 함의)

  • Park, Eun-Jin;Nam, MiA;Kang, Gyui
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.1
    • /
    • pp.107-117
    • /
    • 2012
  • We estimated the potential area roof greening in Gyeonggi-do that will mitigate the heat island effect. The estimation was based on building age, roof shape, and building use which were recorded in the building register from "Sewoomteo, the Building Administration System in the Ministry of Land, Transport and Maritime Affairs. The estimated potential roof greening area in Gyeonggi-do was approximately $102.5km^2$ assuming that the buildings for residence, public, education(school), office, shopping mall are appropriate for roof greening. The area occupied by apartment buildings over six-story was 76.3% of the potential roof greening area 10.2% for individual houses, 5.9% for under five-story apartment buildings, and 3.7% for school buildings. The result indicated that it is residential buildings that we need to pay attention for roof greening, especially high-rise buildings over six-story. Greening of the whole estimated area, $102.5km^2$, in Gyeonggi-do will result in the increase of green space per capita by $8.74m^2$. This is 1.65 times greater than the area of current urban parks, and 1.97 times greater than the total area of neighborhood parks, children's parks, and pocket parks. Greening of the estimated roof area will increase green coverage of urban area by twice, adding to current green coverage of the urban areas, 11.3%, in 10 major cities. In particular, the effect of roof greening would be remarkable in inceasing the green space of Anyang City, Gwangmyeong City, and Guri City where neighborhood park area falls short.

A Study on the Performance Increase in Building Energy Technology according to the Korea's Zero Energy Building Policy (한국의 제로에너지건축 정책 추진에 따른 건축물 에너지기술 성능 연구)

  • Shim, Hong-Souk;Lee, Sungjoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.543-553
    • /
    • 2021
  • As a key policy for achieving the goal of reducing GHG in the building sector, Korea has enforced the mandatory certification of zero-energy buildings for new buildings in the public sector from 2020. This study evaluated a policy to achieve Net Zero by identifying the trend of changes in building energy performance according to policy and presenting a methodology to analyze the current performance state of energy technology applied to buildings. The final goal was to help stakeholders apply appropriate energy technologies for new buildings. For this study, data collected on building energy efficiency certification over the last four years have shown a gradual increase in energy performance. In addition, K-means cluster analysis was used to analyze the performance status of energy technologies applied to buildings. The high and low clusters of education and office facilities were used to analyze the comparative group (2016-2020, 2020). As a result, the solar module area in both high and low clusters of education facilities increased by 261.1% and 283.5%. In contrast, the solar module area decreased by both high and low clusters of office facilities. The most passive and active technologies showed an increase in energy performance.

A Feng Shui Analysis of the Locations of the Main Buildings in the Palaces of Joseon Dynasty (조선시대 궁궐 정전(正殿)의 배치형식에 투영된 풍수구조)

  • Jung, Woo-Jin;Go, Je-Hee
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.34 no.1
    • /
    • pp.18-39
    • /
    • 2016
  • The study pertains to reviewing and discussing of the master plan of the main buildings in the palaces of Joseon Dynasty regarding on a Feng Shui concept that has been implemented on the palace axis that is originated from the main mountain. Gyeongbokgung (景福宮) Palace is located on the northwest coner of Hanyang (漢陽) and on the tip of the main mountain which is in contrast a quite distinguishable from the location of the Fobidden city in Beijing located in the middle of a vast basin. Changdeokgung (昌德宮) Palace as well is also located on the tip of Eungbong (鷹峯), a part of Samkaksan (三角山) mountain, of which the locations were designed for the palaces to receive the benevolent force from the main mountain. The same concept was also applied to appointing the ideal location of the maJor buildings such as Jungjeon (正殿: The throne hall), Pyunjeon (便殿: The king's office) and Chimjeon (寢殿: The king and queen's residence) in the palace that must receive the benevolent force from the qui stream also originated from the main mountain, as such that the buildings have in close relationship with the king. Amisa (蛾眉砂) had been considered as an important geographical milestone of the estate where the palace is located, especially as the guiding landmark for other buildings that must be on the land axis. The land axis with the Amisa as the starting point attributed the Feng Shui as an important measure that determines the location and the shape of other buildings. The buildings location was appeared as having the conceptual buildings location as 'front office-back bedroom building (前朝後寢)' and 'three gates-three sectors (三問三朝)' as per the Rites of Zhou (周禮). On both palaces, Amisa is located on the benevolent point of the land, and the king's bed room buildings are located near the Amisa. The main offices were located on the south of the king's bed room buildings. By practicing this type of concept, consequently the king can receive the pure benevolent force first. In the case of the clearly distinguished locations of the buildings in Gyeongbokgung Palace, Chimjeon, Pyunjeon and Jungjeon were located on the same main qui stream. However, in Changdeokgung Palace where scattered qui stream is observed, the buildings are located on the scattered qui stream. The study found that the type of location of Jungjeon receives least amount of benefit from the Feng Shui but reflects primarily the king's authority rather than order and formality of the space.

Impact of Indoor Plants on Indoor Air Quality and Occupational Health in Newly Built Public Building Offices - Focusing on Allergic Conjunctivitis and Stress-related Symptom Questionnaires - (신축건물 사무실내 식물 적용의 실내 공기질 및 재실자 건강영향 평가 - 알레르기 비결막염 및 스트레스 관련 증상설문을 중심으로 -)

  • Lee, Yong Won;Lim, Young Wook;Kim, Kwang-Jin;Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.4
    • /
    • pp.334-348
    • /
    • 2017
  • Objectives: We investigated the impacts of indoor plants on indoor air quality and occupational health, focusing on allergic rhinconjunctivitis and stress among employees in new office buildings. Methods: A total of 34 employees working at new public office buildings were enrolled as subjects (n=17, with indoor plants) and as a control (n=17) group. Before and after introducing indoor plants for three months, indoor air quality measurements including VOCs and aldehydes and questionnaires on sick building syndrome, AR symptoms (ARIA based), stress (DASS 42, KOSS, and SACL), and indoor characteristics were performed and statistically analysed. Results: Among the 34 enrolled subjects, 19 were included in the probable AR subject group (subjects with indoor plants, n=8, control n=11) and completed all questionnaires. Statistical analyses were done for total, AR subject groups, and controls. As a result, it was confirmed that major indoor air pollutants decreased after the introduction of indoor plants (p<0.5). Among major symptoms of allergic rhinoconjunctivitis, watery rhinorrhea, nasal stuffiness, and nasal itching indexes decreased (p<0.5, respectively). A decrease was noted in some areas of work-related stress indexes (mainly KOSS) among the subject group (total and AR) and a decrease of indoor environmental attractiveness among the control group (total and AR) (p<0.5, for all). Conclusions: Indoor plants may help reduce indoor air pollutants and decrease AR symptoms and work-related stress of employees in newly built office buildings. Various further follow-up studies on the mechanism of environmental, physical, and emotional influences and utilization of indoor plants in association with allergic diseases will be needed.