• 제목/요약/키워드: Office Buildings

검색결과 621건 처리시간 0.028초

사무소용 건물의 설비유지관리 실태에 관한 조사연구 (A Study on the Actual Conditions of Maintenance for Service Facilities in Office Buildings)

  • 손장열;이승언
    • 대한설비공학회지:설비저널
    • /
    • 제14권1호
    • /
    • pp.12-20
    • /
    • 1985
  • This paper aims to present the basic data to establish resonable building maintenance standards by investigating and analyzing the actual conditions of maintenance for service facilities and the problems due to the situation. The subject buildings of investigation are 10 stories and above off ice buildings in Seoul. The results obtained from this study are as follows. 1. The equipment service life related to air-conditioning system is known as around 9years in case of breakdown maintenance and around 13 years in case of preventive maintenance. 2. The total mechanical room area against the total floor area is $4.40\%$, and the ratio of air-conditioning room area is $1.78\%$ on an average.

  • PDF

이미지 분류 기반 노후 건축물 균열 검사 모델 연구 (A Study on the Crack Inspection Model of Old Buildings Based on Image Classification)

  • 채종택;이웅균
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.331-332
    • /
    • 2023
  • With the aging of buildings, the number and importance of regular inspections of buildings are increasing. The current safety inspection goes through a procedure in which a skilled technician visits an old building, visually checks it, takes a photo, and finally organizes and judges it at the office. For this, field personnel and analysis and review personnel are required. Since the inspection procedure includes taking pictures, a huge amount of data has been accumulated from the time digital photos were used to the present. When a model that can check cracks outside a building is developed using these data, manpower and time required can be greatly reduced. Therefore, this study aims to create a model for classifying cracks that occur outside the building through the artificial intelligence method. The created model can be used as a basic model for determining cracks only by external photography in the future, and furthermore, it can be used as basic data for calculating the size and width of cracks.

  • PDF

그린빌딩화를 통한 청사 업무환경 개선을 위한 사용자 의식에 관한 연구 - 제주특별자치도 제 1, 2청사를 중심으로 - (A Study on User's awareness for Workable Environment Improvement of Public Building by Green Building Renovation - Focus on the 1st & 2nd Buildings of Jeju Special self-Governing Province -)

  • 오창훈;김태일;양건
    • 한국실내디자인학회논문집
    • /
    • 제19권3호
    • /
    • pp.162-171
    • /
    • 2010
  • In the field of architecture, the sustainable architectural concept, "green buildings," has been suggested as an alternative to solve the environmental problems; however, the concept has not yet been converted to awareness and development of related technology. The leading role of public sector has been socially and economically influential in the nation, hence green public buildings are significant to stimulate the spread of green buildings in the nation. This study is to draw an appropriate method of implementing the green building concept to the two main government office buildings of Jeju Special Self-Governing Province based on the plan to improve the work environment; it is also to provide long-term directions of implementing policies and reference for the public and private sector to utilize the green building concept. Its research methodology was the survey method. A total of 142 questionnaires were returned by government employees of the two buildings. It accounts for 20% of the total number of 711 workers of the buildings. According to the analysis of the returned questionnaire, the majority of the surveyed have a positive evaluurned toward the introduction of green buildings due to their expecturned for the possible i the buildingstheir work environment. In addition, they showed more interest in space planning with natural ventilation than automatic systems regarding applied methods for green buildings.

여름철 사무실내 한국인의 온열감 평가 (Evaluation of Korean Thermal Sensation in Office Buildings During the Summer Season)

  • 배귀남;이철희;이춘식
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.341-352
    • /
    • 1995
  • In this study, thermal parameters were measured and 213 occupants were also questioned in three office buildings located in Seoul during the summer season. Predicted mean vote-predicted percentage of dissatisfied(PMV-PPD) and standard new effective temperature(SET*) were used for evaluating Korean thermal sensation. The distribution of thermal sensation vote(TSV) and percentage of dissatisfied(PD) is very similar to that of PMV and PPD. By regression analysis, the following regression equation was obtained; TSV=0.339SET*-8.583. In this case, neutral temperature and comfort range are $25.3^{\circ}C$, $23.8{\sim}26.8^{\circ}C$ respectively. Present experimental results obtained from the field study is less sensitive to the temperature change than those obtained from the climate chamber study in Korea. But, thermal sensations are similar to each other near the neutral point. The neutral temperature and comfort range obtained by this experiment are higher than those of ANSI/ASHRAE Standard 55-1974 about $1.4{\sim}1.8^{\circ}C$.

  • PDF

사무소 건물에서 냉동기의 부분부하율 및 냉방 에너지 성능 특성 분석 (A Detailed Analysis of the Part Load Ratio and Cooling Energy Characteristics of Chiller Operation in an Office Building)

  • 서병모;유병호;이광호
    • 설비공학논문집
    • /
    • 제27권11호
    • /
    • pp.567-573
    • /
    • 2015
  • Commercial buildings account for significant portions of the total building energy in Korea, and thus, a variety of research on chiller operation has been carried out. However, most of the studies were carried out on the chiller itself, i.e., the part load ratio characteristics and the corresponding electricity energy consumption patterns were not analyzed in existing studies. In this study, the part load ratio and the operating characteristics of the vapor compression chiller were analyzed within an office building equipped with the conventional variable air volume system. As a result, significant portions of total operating hours, cooling load, and energy consumption turned out to be in the part load ratio range of 0 through 50%. Thus, energy consumption was significantly affected by the chiller COP at low part load conditions, indicating that chiller operation at the part load is an important factor in commercial buildings.

신·재생에너지 공급의무화제도(RPS) 비율을 고려한 타당성 분석의 공사비 산정 프로세스 (Process of Cost Estimation in Feasibility Analysis Considering ratio of Renewable Portfolio Standard)

  • 양현주;김종협;한상원;현창택
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.44-45
    • /
    • 2014
  • Recently the Korean government also has strictly restricted a law such as GBCC(Green Building Certification Criteria)and RPS(Renewable Portfolio Standard) on the construction. Especially the government announced a obligation of renewable energy consumption over 12% for all the public buildings of total area over 1,000㎡ since 2014. Regarding to the policy, this study presented the economics of energy analysis of the public office buildings that supplies 12% renewable energy output in the early stage of construction project. This paper calculated on CO2 emission by the geothermal, solar heat, and solar photovoltaic system and estimated the saving cost. Reduced cost through the energy saving are predicted to influence on the total construction cost. As a result air pollution and energy saving cost are expected that renewable energy system would be saving total initial cost of construction on planning phase.

  • PDF

창면적비 및 향변화에 따른 슬랫형 블라인드의 최적각도 제어 알고리즘 산출 및 비교분석 (Development and comparative analysis of slat angle control algorithm of venetian blind according to window-to-wall ratio and zone orientation)

  • 권혁주;이금호;이광호
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: Most contemporary office buildings supply external views, a sense of openness and a sense of time to their occupants by adopting the curtain walls, which are equipped with an outer cover having large window area. As a result, the amount of radiation increases, adversely affecting cooling load during the summer in office buildings. Although solar radiation decreases heating load and reduces energy costs during the winter period, due to the characteristics of offices where occupants work largely during daytime, the cooling load is important compared to the heating. Therefore, diverse measures to resolve those trade-offs and annual energy cost have been investigated. Method: In this study, the annual thermal load was comparatively analyzed according to the slat angle of the venetian blind along with lighting control technique. Result: After selecting effective conditions, in order to resolve such issues, this study established automated control strategies of slat angle depending on the window-to-wall ratio and zone orientation, so that the findings of this study can be effectively generalized to other circumstances.

고층건물에서 로비층의 평면형태가 연돌효과에 미치는 영향 (Effect of the a floor plan of lobby floor for the Stack Effect in a High-rise Building)

  • 이준호;임현우;서정민;이중훈;송두삼
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.293-299
    • /
    • 2009
  • Many kinds of problems by stack effect occur in the high-rise buildings that have the simple plan on the first floor designed only by an external wall and an E/V shaft wall. Therefore, some buildings in the foreign countries has made the additional inside walls between lobby and E/V hall as a countermeasure on stack effect. An additional wall in the lobby is very useful countermeasure on stack problems because lobby is a main airflow path in the building. Decreasing effect on stack problems by an additional wall of lobby is reported in this study. An ordinary office building that has a simple lobby plan is simulated and measured in this study. The results show that characteristics on stack effect are changed by methods of applying additional walls and that alternations of countermeasures which building conditions like the kinds of problems and the problem's velocity etc. are considered are very important.

  • PDF

산란광 광량 적산시 Digital Dust Indicator에 의한 도서관과 학생회관내 $PM_{10}$ 농도의 일변화 (Diurnal Variation of $PM_{10}$ Concentrations in Library and Student Buildings using Scattering Light Integrated Type Digital Dust Indicator)

  • 김만구;권영진;정영림
    • 한국대기환경학회지
    • /
    • 제13권2호
    • /
    • pp.115-122
    • /
    • 1997
  • Diurnal variation of $PM_{10}$ concentration was investigated for 24 sites in library including reading room, bookstock room, lobby, office and so on, and 9 sites in student building at Kangwon National University using scattering light integrated type digital dust indicator. The dimensional conversion factors for mass concentrations (K) were determined by comparing between the $PM_{10}$ concentrations collected by $PM_{10}$ hig volume air sampler and the digital dust indicator. The dimensional conversion factor (K) was 3.33 for indoor air in this experiment. The highest concentrations were 649 $\mug/m^3$/day for smoking room in the library and 242 $\mug/m^3$/day for circle room in the student building. Most of spaces in the library except a office and bookstock rooms were over 150 $\mug/m^3$/day of $PM_{10}$ concentrations and 6 indoor spaces were over the guideline for indoor air quality in student building except a health center and two restaurants. Therefore, it should be required to make an improvement on the indoor air quaility for public facilities in the university buildings.

  • PDF

사무소건물 조명기기와 열원기기의 고효율기기로의 교체에 관한 경제성 검토 (Feasibility Study on Retrofitting Lighting and Heat Source Equipments in Office Buildings)

  • 이철구;김종대;임태순
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권2호
    • /
    • pp.13-18
    • /
    • 2016
  • Energy saving has been main concern, thus government supporting policies which are based on Fundamentals of Low-carbon Green Growth Act', 'Green Building Support Act, have been prepared in Korea. The objective of this study is to estimate energy conservation effectiveness and economic advantage assuming that lighting equipments and heat source equipments would be retrofitted. Office building, which has total floor area of $30,000m^2$, was a subject of this study. From the estimations, electric rate will be decreased by 62,886,000 won per year due to lighting equipments retrofit, and gas rate will be decreased 11,141,000 won or 17,332,000 won per year due to heat source equipments retrofit (in case of COP 1.2 or 1.5). Payback period of each case that are calculated by energy saving cost and retrofit cost are estimated 27.9 year, 38.6 year and 29.2 year, thus economic supporting policies is necessary for effective energy saving in buildings. Meanwhile payback period of heat source equipment for new building is estimated 6.1 year and 8.3 year.