• Title/Summary/Keyword: Office Buildings

Search Result 621, Processing Time 0.023 seconds

Characterization of Live Fire Load in Buildings - Heat Release Characteristics of Typical Live Fire Load in Post Office Building - (건축물의 적재가연물 특성에 관한 연구 -우체국 적재가연물의 연소성상 -)

  • Nam, Dong-Gun;Yuji, Hasemi;SaKong, Seong-Ho;Jung, Jong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.7-10
    • /
    • 2008
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in post office buildings in Japan. In this report, burning behavior of typical combustible objects in post office buildings are studied by measuring heat release rates of plastic palettes with and without postal envelopes or packages and special containers loading numbers of palettes. The test results suggest that dynamic heat release rate is highly dependent on the condition of palettes especially if they load appropriate amount of postal envelopes or not.

  • PDF

A Study on the Environmental Load of Office Buildings in Seoul

  • Lee, Sang-Hyung;Lee, Yun-Gyu;Yang, Kwan-Seob;Ahn, Tae-Kyung;Lee, Seung-Eon;Park, Hyo-Soon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.58-64
    • /
    • 2001
  • This study is to examine the emission quantity of $CO_2$ gas as the environmental load in office buildings. After the investigation of monthly consumption of each energy source(electricity and natural gas), it is analyzed that the $CO_2$ emission quantity of 34 office buildings surveyed is 22.4 kg-c/$m^2$-year, which consists of 17.5 kg-c/$m^2$-year by consurunlelectncif. and 4.9 kg-c/$m^2$-year by consuming natural gas. And the $CO_2$ emission quantity of each load in those buildings consists of 68% emitted by general electricity, 16% by cooling load and 16% by beating load. It is also proposed that the $CO_2$ emission quantity of cooling and heating load is profoundly pertinent to the variation of outdoor temperature.

  • PDF

A study on the environmental load of office buildings in Seoul (서울지역 사무소 건물의 환경부하에 관한 연구)

  • 이상형;이윤규;양관섭;안태경;이승언;박효순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.244-249
    • /
    • 1999
  • This study is to examine the emission rate of $CO_2$gas as the environmental load in office buildings. After the investigation of monthly consumption of each energy source(electricity and natural gas), it is analyzed that the $CO_2$emission rate of 34 office buildings surveyed is 22.4kg-$c/m^2$.year, which consists of 17.5kg-$c/m^2$.year by consuming electricity, and 4.9kg-$c/m^2$.year by consuming natural gas. And the $CO_2$emission rate of each load in those buildings consists of 68% emitted by general electricity, 16% by cooling load and 16% by heating load. It is also proposed that the $CO_2$emission rate of cooling and heating load is profoundly pertinent to the variation of outdoor temperature.

  • PDF

A Study on Grouped Management System of Post Office Buildings (우정건축물의 효율적인 관리시스템 구축 방안)

  • Gang, Oh-Sik;Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.103-107
    • /
    • 2008
  • There are about 160 post office buildings of medium and/or large scale in Korea Energy saving and efficient manpower management for the buildings are important. In this paper, patterns of the operation and energy consumption of the post office buildings are analyzed. The authors suggest an integrated and grouped management of the dispersed post office buildings using internet, through which more improved efficiency can be expected.

Who Occupies the Green Building: a Case of Australia

  • Kim, Sumin;Kim, Jinu;Lim, Benson T.H.
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.549-553
    • /
    • 2015
  • For successful outcome of real estate development projects, it is important to understand the potential tenants as they drive the demand for properties. The aim of this study is to investigate tenant characteristics of the Australian green office building sector. The specific objectives are to; (1) compare and contrast the increment trend of green buildings within the green office building sector; (2) identify the tenancy profile of green buildings; (3) ascertain the possible industry concentrations within the current green building sector; and (4) explore the relationship between green building occupants' characteristics and their tenancy. Descriptive statistics shows that Finance, Insurance and Real Estate (FIRE) industries along with government owned companies are the major tenants of green office buildings in the NSW State of Australia. In particular, real estate companies occupy more than half of the NSW based green office buildings whilst one third of them are the tenants of the 6-star rated buildings - the highest rated building in the current form of Australian Green Star accreditation scheme.

  • PDF

Remodeling and Extension of reused Goon(郡) Office Buildings in the Japanese Colonial Period (일제강점기 기존 건물을 전용한 군청사의 개축 및 증축 양상)

  • Kim, Myungsun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4992-4998
    • /
    • 2015
  • The purpose of this study is to investigate that which Goon office buildings were reused from existing buildings and to identify remodeling and extension ways of the reused to match Goon's administration work. This study used literature research method, i.e., analysing the digital images, the annotation, and the official documents between the Japanese government-general of Korea and To(道), and articles of newspapers and journals. The reused were governmental offices of Joseon(朝鮮) dynasty, existing Goon office buildings of Korean empire government and old buildings with unknown purposes. They were remodelled and extended to match Goon's administration work. Common remodelling was making large space with desks for civil petitions and projecting an small entrance from the center of main building's facade. Common extension was constructing accessory buildings with simple wooden structure, locating them to back or side of the reused, and connecting them through external corridor. As many as 30% of 218 Goon office buildings were reused. About 57% of them were replaced as new office buildings, however the number of the new was rapidly decreased after mid 1930s.

Energy self-sufficiency of office buildings in four Asian cities

  • Kim, Jong-Jin
    • Advances in Energy Research
    • /
    • v.2 no.1
    • /
    • pp.11-20
    • /
    • 2014
  • This paper examines the climatic and technical feasibilities of zero energy buildings in Seoul, Shanghai, Singapore and Riyadh. Annual and seasonal energy demands of office buildings of various scales in the above cities were compared. Using optimally tilted rooftop PV panels, solar energy production potentials of the buildings were estimated. Based on the estimates of onsite renewable energy production and building energy consumption, the energy self-sufficiencies of the test buildings were assessed. The economic feasibilities of the PV systems in the four locations were analyzed. Strategies for achieving zero energy buildings are suggested.

The Method of Evaluating The Potential for Conversion Legal Problems with Conversion And Basic Capacity of Vacant Onces in Tokyo

  • Sato, Kouichi;Matsumura, Shuichi;Namiki, Kenji
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.301-306
    • /
    • 2002
  • In Japan, the vacancy rates of office buildings have been at high in big cities since 1992. This problem is especially acute in Tokyo, where it is estimated that over 2.27 million square meters of office floor area will be oversupplied in 2003: big urban redevelopment projects will be completed in 2003. Under these circumstances, International Cooperative Research and Development on Sustainable Urban Management by Conversion of Buildings, called “SUMCOB”, has been carried out. This research aims to regenerate urban areas by converting redundant offices into flats, although instances of conversion are still very few in Japan. This paper introduces part of current results by SUMCOB, and discusses legal problems with conversion and basic capacity of vacant offices in Tokyo. It has been confirmed that there are no constraints concerned with Real Estate Registration Law (although it requires the change of the registration after conversion). and City Planning Law. However, some criteria are incompatible with Building Standard Law and Fire Service Law if the use of the building is changed from offices to flats. Typical incompatibility between offices and flats is lightening. If the buildings do not satisfy criteria for flats, the cost of renovation works for conversion will increase. To examine the basic capacity of vacant office buildings for conversion, field surveys in Tokyo have carried out at three areas: Kodenmacho (Chuo-ku), Toranomon (Minato-ku), and Iwamonocho (Chiyoda-ku). They are typical office areas that are included in center core of Tokyo. In Chuo-ku, the oldest commercial area in Tokyo, textile merchants have been located their headquarters. In Minato-ku, many rental office buildings have been located and several large scale redevelopments are advancing. Chiyoda-ku includes Marunouchi area, which is the prime office area in Japan. Thirty percent of the buildings in survey areas suffer from over twenty percent vacant floor rate, and fifty five percent were constructed before 1990. Especially most of buildings over forty percent vacant floor rate were constructed in 1980s. Vacant office problems haven't been seen in old buildings in Tokyo yet. The number of dwelling units made from office space will influence the conversion scheme. Seventy percent of the office buildings in survey areas have floor area of less than two hundred square meters. If they have been subdivided into two bedrooms type or three bedrooms type, the number of dwelling units in a floor would be less than three. The difficulty of conversion planning derives from frontage size, depth size, and their proportion. The five categories are proposed to grasp actual requirements for converting offices into flats.

  • PDF

The Effect of Eco-friendly Characteristics on the Price of Office Buildings (친환경 특성이 오피스 빌딩 가격에 미치는 영향)

  • So, Soung Kue;Cho, Joo Hyun
    • Korea Real Estate Review
    • /
    • v.28 no.2
    • /
    • pp.49-64
    • /
    • 2018
  • The purpose of this study is to analyze the effect of eco-friendly building certification grade on the price and cost of office in Seoul office building. For this purpose, multiple regression analysis is used to examine the prices of buildings. In order to identify the effect of environmental cost reduction of buildings with high eco-friendly certification, we also performed LCC (Life Cycle Cost) + LCA (Life Cycle Assessment) analysis. Results of our analysis show that office buildings with a higher level of eco-friendly certification are priced significantly higher. Through LCC analysis, it was also found that buildings with high levels of eco-friendly certification cost less than those with lower-level certification. Furthermore, it was confirmed that office buildings with higher-level environmental certification have total lower environmental load costs (TCA = LCC+LCA) than buildings without certification. According to the TCA analysis, buildings with a high level eco-certification generated lower social costs than buildings with lower-level or no certification.

Low-energy Tall Buildings? Room for Improvement as Demonstrated by New York City Energy Benchmarking Data

  • Leung, Luke;Ray, Stephen D.
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.4
    • /
    • pp.285-291
    • /
    • 2013
  • This paper proposes a framework for understanding the energy consumption differences between tall and low-rise buildings. Energy usage data from 706 office buildings in New York illustrates expected correlations from the framework. Notable correlations include: taller buildings tend to use more energy until a plateau at 30~39 floors; tall buildings in Manhattan use 20% more energy than low-rise buildings in Manhattan, while tall buildings outside Manhattan use 4% more energy than low-rise buildings outside Manhattan. Additional correlations are discussed, among which is the trend that the Energy Star program in New York City assigns higher ratings to tall buildings with higher EUIs than low-rise buildings with the same EUI. Since Energy Star is based on regressions of existing buildings, the Energy Star ratings suggest taller buildings have higher EUIs than shorter buildings, which is confirmed by the New York City energy benchmarking data.