• Title/Summary/Keyword: Office Buildings

Search Result 621, Processing Time 0.021 seconds

A Study on Information of the Green building Design for friendly environment (환경 친화를 위한 그린빌딩 디자인 정보에 관한 연구)

  • 강승모;김수정;권자인
    • Korean Institute of Interior Design Journal
    • /
    • no.25
    • /
    • pp.26-33
    • /
    • 2000
  • The end of the 20th century, on the ecological world-view which looks the whole things as systematic and admits the incessant change, human is considered to function with the environment mutually and to evolve in harmony with it. Because of the living style of the modern people whose most time spent inside of the buildings, eco-office elements are introduced in the inteior places where many general publics are gathered. We gather up the all information about Eco-office, introduction of green building certification system, Eco-office System Technics and provide source to how to design interact with eco-office.

  • PDF

Selection to the Optimal Windows Transmittance of Office Building on Sky Conditions (천공상태에 따른 오피스 창호의 적정 투과율 선정)

  • 임오연;김병수
    • Korean Institute of Interior Design Journal
    • /
    • no.38
    • /
    • pp.225-232
    • /
    • 2003
  • The purpose of this study is to select the optimal and minimum transmittance for visual amenity in office buildings. This study progressed as follows. The first, we select 5 films with various transmittance based on the current film makers whose films being used on the windows of office building nowadays and the case study of construction. And then we choose 6 kinds of transmittance as evaluation object including plain glass. The second, we made a mock-up models having different transmittance on the southern windows with model of real scale office building. The third, we select 17 pairs of adjectives for the evaluation of visual comfort on interior or exterior conditions with transmittance factor. The fourth, subjective evaluation experiment was done using selected evaluation adjectives and the result was analyzed. The results are as follows : the minimum transmittance appropriate for the office building is 30%∼40% and the optimal transmittance range is 40%∼60%.

Analysis of Energy Performance and PMV Improvement by Application of Passive Factor for Office Building Renewal (오피스건물 리뉴얼시 패시브 요소적용에 따른 에너지성능 및 PMV 개선에 관한 연구)

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.55-64
    • /
    • 2014
  • This paper presents a case study to investigate the monthly calculation method of ISO 13790 applied for a office building. The energy performance analysis according to improvement of insulation and air permeability of windows in K office buildings is investigated by means of building energy efficiency rating tool ($ECO_2-OD$). The K building energy system is tested experimently by the measurement of PMV(predicted mean vote) for the control of indoor thermal environment and heat transmission coefficient of windows and interior walls respectively, before and after the example K office building is remodeled passively. Therefore, Internet based energy assessment program of energy efficiency rating of office building can be applied as a program for the annual energy requirement and for evaluation of energy savings from the experimental and simulation results.

An Analysis of the Trend on the Interior Lighting Design of High-rise Office Buildings in Korea (국내 초고층 오피스 건축물의 조명설계 경향 분석)

  • Jeong, Keun-Young;Hong, Seong-Kwan;Choi, An-Seop;Lee, Jeong-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.157-160
    • /
    • 2007
  • Recently, may high-rise buildings have been constructed, and will be constructed so that concerns about high-rise buildings have increased. We need to develop energy saving techniques immediately because the high-rise buildings consume a lot of energy. The most of effective energy saving method is the application of the efficient lighting designs and fixtures. The purpose of this study is to analyze the trend of lighting design, fixture and control system in Korea and it can be used the lighting application guide-line for the high-rise buildings.

  • PDF

A Study on Process for District Office Building Maintenance with EPIQR+ (on Focusing Energy and Economics Evaluation) (EPIQR+를 이용한 구청사 건물에 대한 경제적, 에너지관점에서의 건물 재평가)

  • Kim, Tae Han
    • KIEAE Journal
    • /
    • v.9 no.5
    • /
    • pp.13-20
    • /
    • 2009
  • This study suggested practical application of decision aid tool on re-evaluation of current buildings with a focus on a energy and economics evaluation methodology. In Europe, over forty percent of all construction activities are for retrofit. For efficient construction, various tools for re-evaluating existing buildings have been developed and are in use. Legislations of relevant laws and studies are actively initiated. In particular, EPIQR (Energy Performance Indoor environment Quality Retrofit), which was developed through the EU's Third and Fourth Framework Programs laid a foundation on a new concept-based decision aid tool for re-evaluation of existing buildings. As for actual applications, based on this, EPIQR+ was developed to be in line with a building maintenance guideline (SIA 469) and is actively applied to public buildings. This tool quantifies the degree of damages of existing buildings and suggests alternatives to users in energy (SIA 380/1) and economical perspectives. This study examined these preceding tools and suggested some trenchant approaching for more comprehensive and efficient use of re-evaluation tools in building maintenance.

Evolution of Tall Building Structures with Perimeter Diagonals for Sustainable Vertical Built Environments

  • Kyoung Sun Moon
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.4
    • /
    • pp.307-320
    • /
    • 2023
  • Tall buildings are built with an abundant amount of materials, including structural materials, coming from our limited natural resources. Tall buildings that began from about 10-story tall office towers have evolved to over 150-story tall mixed-use megastructures. As a building becomes taller, structural material requirement to resist lateral wind loads becomes exponentially larger. Therefore, it is crucial to employ efficient structural systems and optimize their design, which will contribute to sustainable vertical built environments through preservation of resources. Tube type structures with large perimeter diagonals are among the most efficient structural systems for tall buildings. Developments of braced tube, braced megatube, diagrid structures, and their optimal design strategies are reviewed. Superframed conjoined towers, produced by interconnecting multiple clustered braced tubes, are presented as a new design direction to achieve not only structural but also architectural and social sustainable design goals.

A Study on the Representation Method of Traditionality of Mekuro-Kazoen BLDG. in Japan (일본 메구로가조엔건물의 저농성표현기법연구)

  • Kim, Eun-Joong
    • Journal of architectural history
    • /
    • v.7 no.1 s.14
    • /
    • pp.109-120
    • /
    • 1998
  • Mekuro-Kazoen BLDG. is a complex of office, hotel, and banquet halls, builted in 1991, Tokyo, Japan. This building suggest us various issues about the representation of traditionality in current architecture. We can find the possibility of representation of traditionality in large complex, in past, rarely applicated. Even in Japan, such trial in official building as New Office Building of Tokyo in Sinzuku shows a application only in the elevation plan. In Mekuro-Kazoen BLDG, the applications of traditionality are found not only in external appearance, but also in interior design. And the traditional Japanese gardens in front of building and in atrium enrich the traditionality And the modenity and traditionality in this building are represented simultaneously not deteriorating each other. The issue of representation of traditionality in architecture should be succeed not only in now but also in the future. The method of application need to be studied and improved. The fields of application also should be extended such as large complex buildings and future-oriented buildings.

  • PDF

Study on Live Loads in Office Buildings (사무실 적재하중의 통계적 조사 연구)

  • 김상효;조형근;배규웅;박홍석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1989.10a
    • /
    • pp.25-28
    • /
    • 1989
  • Live load data in domestic office buildings have been collected in a systematic manner. Based on surveyed data, equivalent uniformly distributed load intensities, which produce the same load effect as the actual spatially varying live load, have been obtained for various structural members(such as slab, beam, column, etc.). Influence surface method has been employed to compute load effects under real live load, inclucing beam moment, slab moment as well as axial force and moments in column. The results have been examined to find probabilistic characteristics and relationship between influence area and load intensity(or coefficient of variation). The results were also compared with other survey results and found to be reasonable.

  • PDF

A Study on the Interior Design Method of Mekuro-Kazoen BLDG. in Japan (일본 메구로가조엔 건물의 실내설계기법에 관한 연구 - 전통성의 현대적 표현 사례 -)

  • 김은중
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 1999.04a
    • /
    • pp.110-113
    • /
    • 1999
  • Mekuro-Kazoen BLDG. is complex of office, hotel, hotel, and banquet hall, built in 1991, Tokyo, Japan. This building suggest us various issue about the representation of traditionality in current architecture. We can find the possibility of representation of traditionality in large complex, in past, rarely applicated. Even in Japan, such trial in official building as New Office Building of Tokyo in Sinzuku shows a application only in the elevation plan. In Mekuro-Kazoen BLDG. the application of traditionality are fond not only in external appearance, but also in interior design. And the modernity and traditionality in this building are represented simultaneously not deterioating each other. the issues of representation of traditionality in interior design should be succeed not only in now but also in future. The method of application need to be studied and improved. The fields of application also should be extended such as large complex buildings and future-oriented buildings.

  • PDF

An Analysis on Building Shading Plan for a City Hall considering Energy Saving

  • Kim, Jin Lee;No, Sang Tae
    • KIEAE Journal
    • /
    • v.16 no.2
    • /
    • pp.5-10
    • /
    • 2016
  • Purpose: Recently, many public office buildings which were built by curtain wall increased rapidly, but the results of the investigation of the government, these buildings have been found that the heating and cooling thermal load is high, and showed low energy efficiency. Method: To evaluate the effects by applying outdoor louver and indoor blind, which can control solar radiation in order to reduce the heating and cooling load of public office building which was built by glass curtain wall. The heating and cooling load was calculated via Energyplus, building and outdoor louver, indoor blind were modeled by Google sketchup connected to Energyplus. Result: The results of this study were as follows; the case of applying various outdoor louver, the heating and cooling load all decreased as compared to the case without applying outdoor louver, the case of applying indoor blind, the heating and cooling load decreased as compared to the case without applying indoor blind, but indoor blind showed low energy performance comparing outdoor louver.