• Title/Summary/Keyword: Off-axis level

Search Result 33, Processing Time 0.027 seconds

Tension-Compression Asymmetry in the Off-Axis Nonlinear Rate-Dependent Behavior of a Unidirectional Carbon/Epoxy Laminate at High Temperature and Incorporation into Viscoplasticity Modeling

  • Kawai, M.;Zhang, J.Q.;Saito, S.;Xiao, Y.;Hatta, H.
    • Advanced Composite Materials
    • /
    • v.18 no.3
    • /
    • pp.265-285
    • /
    • 2009
  • Off-axis compressive deformation behavior of a unidirectional CFRP laminate at high temperature and its strain-rate dependence in a quasi-static range are examined for various fiber orientations. By comparing the off-axis compressive and tensile behaviors at an equal strain rate, the effect of different loading modes on the flow stress level, rate-dependence and nonlinearity of the off-axis inelastic deformation is elucidated. The experimental results indicate that the compressive flow stress levels for relatively larger off-axis angles of $30^{\circ}$, $45^{\circ}$ and $90^{\circ}$ are about 50 percent larger than in tension for the same fiber orientations, respectively. The nonlinear deformations under off-axis tensile and compressive loading conditions exhibit significant strain-rate dependence. Similar features are observed in the fiber-orientation dependence of the off-axis flow stress levels under tension and compression and in the off-axis flow stress differential in tension and compression, regardless of the strain rate. A phenomenological theory of viscoplasticity is then developed which can describe the tension-compression asymmetry as well as the rate dependence, nonlinearity and fiber orientation dependence of the off-axis tensile and compressive behaviors of unidirectional composites in a unified manner. It is demonstrated by comparing with experimental results that the proposed viscoplastic constitutive model can be applied with reasonable accuracy to predict the different, nonlinear and rate-dependent behaviors of the unidirectional composite under off-axis tensile and compressive loading conditions.

Novel PVA pixel design for mobile application with excellent off-axis image quality

  • Kim, Jae-Hyun;Kim, Gee-Bum;Choi, Ji-Youn;Jang, Yong-Kyu;Ahn, Seon-Hong;Kim, Kyeong-Hyeon;Kim, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.295-298
    • /
    • 2008
  • We developed a novel PVA pixel design for mobile application with excellent off-axis image quality and optical performance by introducing Active Level Shift technology and optimizing pixel structure. Our new pixel design enables better off-axis image quality without sacrificing other optical properties compared with a conventional mPVA structure.

  • PDF

A Proposal of the Maximum Allowable Off-axis e.i.r.p. Level of HAPS Ground Station for Frequency Sharing with 47/48GHz FSS system (47/48GHz FSS 위성 시스템과의 주파수 공유를 위한 HAPS 지상국의 최대 허용 off-axis e.i.r.p. 레벨 제안)

  • Kang, Young-Heung;Choi, Mun-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.3
    • /
    • pp.459-464
    • /
    • 2007
  • Resolution 122 requires to study power limitation applicable for HAPS ground stations to facilitate sharing with space station receivers in 47/48GHz bands. ITU-R Recommendation 1481-1 recommends to improve the side lobe characteristics of HAPS ground station antenna for frequency sharing between FSS system and HAPS system. In this paper, we propose the maximum allowable off-axis e.i.r.p. level of HAPS ground station antennas by considering power limitation to HAPS ground station in Resolution 122, and by improving the side lobe characteristics of HAPS ground station antennas in Recommendation SF.1481-1. The simulation results show that the unfeasible sharing distance between HAPS ground station and FSS earth station can be reduced remarkably, and give the possibility of frequency sharing between two above systems.

A Proposal of the Maximum Allowable Off-axis Level for HAPS Ground Station in 47/48GHz Bands (47/48GHz 대역의 HAPS 지상국을 위한 최대 허용 off-axis 레벨 제안)

  • Choi Mun-Hwan;Kang Young-Heung;Park Jong-Min;Ku Bon-Jun;Ahn Do-Seob
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.611-614
    • /
    • 2006
  • Resolution 122 requires to study power limitation applicable for HAPS ground stations to facilitate sharing with space station receivers in 47/48GHz bands. ITU-R Recommendation 1481-1 recommends to improve the side lobe characteristics of HAPS ground station antenna for sharing between FSS system and HAPS system. Thus, in this paper, we propose maximum allowable off-axis e.i.r.p. level of HAPS ground station antennas by considering power limitation to HAPS ground station in Resolution 122 in order to reduce unfeasible separate distance between HAPS and GSO FSS service coverage and improve the side lobe characteristics of HAPS ground station antennas in Recommendation SF.1481-1.

  • PDF

Analysis of Acetone Absorption Spectra Using Off-axis Integrated Cavity Output Spectroscopy for a Real-time Breath Test

  • Lim Lee;Yonghee Kim;Byung Jae Chun;Taek-Soo Kim;Seung-Kyu Park;Kwang-Hoon Ko;Ki-Hee Song;Hyunmin Park
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.761-765
    • /
    • 2023
  • We analyzed the absorption spectra of acetone in the 3.37 ㎛ mid-infrared range using the off-axis integrated cavity output spectroscopy technique to develop a real-time, in-line breath analysis device. The linear relationship between acetone concentration and absorption increase was confirmed as 0.32%/ppm, indicating that the developed device allows for a quantitative analysis of acetone concentration in exhaled breath. To further confirm the feasibility of using our device for breath analysis, we measured the acetone concentration of human breath samples at the sub-ppm level.

A study of Full Width at Half Maximum(FWHM) according to the Filter's Cut off level in SPECT camera (SPECT filter의 cut off level에 따른 반폭치(FWHM) 크기에 관한 연구)

  • Park, Soung-Ock;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.63-69
    • /
    • 2003
  • Filtering is necessary to reduce statistical noise and to increase image quality in SPECT images. Noises controled by low-pass filter designed to suppress high spatial frequency in SPECT image. Most SPECT filter function control the degree of high frequency supression by chosing a cut of frequency. The location of cut off frequency determines the affect image noise and spatial resolution. If select the low cut off frequency, its provide good noise suppression but insufficient image quantity and high cut off frequencies increase the image resolution but insufficient noise suppression. The purpose of this study was to determines the optimam cut off level with comparison of FWHM according to cut off level in each kiters-Band-limited, Sheep-logan, Sheep-logan Hanning, Generalized Hamming, Low pass cosine, Parazen and Butterworth filter in SPECT camera. We recorded image along the X, Y, Z-axis with $^{99m}TcO_4$ point source and measured FWHM by use profile curve. We find averaged length is $9.16\;mm{\sim}18.14\;mm$ of FWHM in X, Y, and Z-axis, and Band-limited and Generalized Hamming filters measures 9.16 mm at 0.7 cycle/pixel cut off frequency.

  • PDF

Optimal Efficiency Control of Induction Generators in Wind Energy Conversion Systems using Support Vector Regression

  • Lee, Dong-Choon;Abo-Khalil, Ahmed. G.
    • Journal of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.345-353
    • /
    • 2008
  • In this paper, a novel loss minimization of an induction generator in wind energy generation systems is presented. The proposed algorithm is based on the flux level reduction, for which the generator d-axis current reference is estimated using support vector regression (SVR). Wind speed is employed as an input of the SVR and the samples of the generator d-axis current reference are used as output to train the SVR algorithm off-line. Data samples for wind speed and d-axis current are collected for the training process, which plots a relation of input and output. The predicted off-line function and the instantaneous wind speed are then used to determine the d-axis current reference. It is shown that the effect of loss minimization is more significant at low wind speed and the loss reduction is about to 40% at 4[m/s] wind speed. The validity of the proposed scheme has been verified by experimental results.

Variation in the Main Kuroshio Path South of Japan

  • Sekine, Yoshihiko
    • Journal of the korean society of oceanography
    • /
    • v.37 no.3
    • /
    • pp.196-200
    • /
    • 2002
  • The time variation in the Kuroshio is studied by use of nine observed distances of the main Kuroshio axis from the Japanese coast. The observed distances over 1975 - 1995 are estimated from the Prompt Report of Oceanographic Conditions published by Hydrographic Department of the Maritime Safety Agency of Japan. It is shown that large sea level difference between Naze and Nishinoomote, which represents the volume transport of the southern inflow south of Kyushu, coincides with larger distance of the Kuroshio in the upstream area from off Kyushu to off eastern Kii Peninsula and smaller distance in the downstream area from off Omae-zaki to off Boso Peninsula. In contrast, large sea level difference between Nishinoomote and Aburatsu, which represents the volume transport of northern inflow south of Kyushu, corresponds to smaller distance in the upstream area and larger distance in the downstream area. Path dynamics of the Kuroshio is discussed with reference to the variation in Volume transport south of Kyushu.

Loss Minimization Control for Induction Generators in Wind Power Systems Using Support Vector Regression

  • Abo-Khalil, Ahmed G.;Lee, Dong-Choon
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.344-346
    • /
    • 2006
  • In this paper, a novel algorithm for increasing the steady state efficiency during light load operation of the induction generator that integrated with a wind power generation system is presented. The proposed algorithm based on the flux level reduction, where the flux level is estimated using Support-Vector -Machines for regression (SVR) for the optimum d-axis current of the generator. SVR is trained off-line to estimate the unknown mapping between the system's inputs and outputs, and then is used online to calculate the optimum d-axis current for minimizing generator loss. The experimental results show that SVR can define the flux-power loss accurately and determine the optimum d-axis current value precisely. The loss minimization process is more effective at low wind speed and the percent of power saving can approach to 40%.

  • PDF

Comparative Evaluation of Resolution according to Frequency Change for SPECT (단일광자방출전산화단층촬영(SPECT)을 위한 주파수 변동에 따른 분해능 비교평가)

  • Kim, Sung-Chul;Park, Soo-Yeun;Cho, Young-Kwon;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.322-331
    • /
    • 2009
  • In clinical SPECT, FWHM provides quality information of the images obtained under different observing conditions. Therefore, the purpose of this study was to determine the optimum cut off level with comparison of FWHM according to cut off levels in each filter - Band limited, Sheep-Logan, Hanning, Hamming, Low pass cosine, Parazen and Butterworth filter in a SPECT camera. I recorded images along the X, Y, Z-axis with 99mTcO4 point source and measured FWHM with profile curves. In conclusion, all filters showed the longest figures of FWHM with cut off level 0.4, which has the worst image resolution. The images with cut off level 0.7 showed best image resolution. The shortest average of FWHM in MS2 was $11.07\pm0.07mm$ using the Butterworth filter, in MS3 it was $8.44\pm0.19mm$ through using the Hanning filter.