• Title/Summary/Keyword: Off axis ratio

Search Result 55, Processing Time 0.024 seconds

Studies on Curved Diffractive Optical Elements in EUV (극자외선 영역에서 곡면 DOEs에 관한 연구)

  • Choi, Sung-Eul;Lee, Yong-Woo;Kwon, Myung-Hoi;Kim, Yong-Hoo
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.304-312
    • /
    • 2005
  • Field performance of several different types of diffractive optical elements(DOEs) has been carried out. Using Zemax model, we have designed five different types of DOEs, such as transmissive flat-DOE, transmissive curved-DOE, reflective flat-DOE, reflective curved-DOE and parabolic mirror, We have applied two different wavelengths, i.e., 13 m(EUV) and 632.8 nm(visible) to above DOEs. Off_axis dominate aberrations and the diffraction limiting (Rayleigh limit) field angles have been investigated and compared at both wavelengths for each DOE. At diffraction limit, field angle of curved-DOEs was much greater than that of flat-DOEs for both transmission and reflective types. We also showed that dominated off_axis aberration of flat-DOEs was coma, but that of curved-DOEs was mixture of astigmatism and curvature of field. The measured field angle and expected OPD aberrations were well coincided with theoretical ones. Increasing the ratio of field angle with wavelength was more effective in curved-DOEs than flat-DOEs.

Magnetic Properties of RF Diode Sputtered FeN Multilayer Films (RF Diode 스퍼터 방법으로 증착된 FeN 다층 박막의 자기적 특성)

  • 최연봉;박세익;조순철
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.1
    • /
    • pp.42-47
    • /
    • 1995
  • FeN thin films for inductive recording heads were sputter deposited using RF diode sputtering mehtod from a pure iron target onto 7059 glass substrates, and their magnetic properties were measured. The magnetic properties were greatly affected by film thickness, gas pressure, sputter power and flow ratio of $N_{2}$ to Ar. Single layer FeN films with their thickness varied from $1,000\;{\AA}$ to $6,000\;{\AA}$ were doposited. 800 W sputter power, 3 mT gas pressure, $N_{2}$ to Ar flow ratio of 6.6 : 100 were the sputtering conditions. Up to 7 layers of FeN films having total thickness of $6,000\;{\AA}$ were deposited using $SiO_{2}$ of $30\;{\AA}$ thickness as intermediate layers and their coercivity and saturation magnetization were measured. The sputtering conditions were the same as those in the single layer films. Easy axis coercivity of the single layer FeN films gradually decreased as their thickness was increased, but for the films with their thicknesses above $3,000\;{\AA}$, the coercivity changed very little. As the number of the FeN layers were increased, the coercivity decreased We estimated the grain size of FeN films from the FWHM (Full Width at Half Maximum) of X-ray diffraction peaks. The grain size steadily decreased from about $200\;{\AA}$ to $120\;{\AA}$ as the number of layers were increased. Minimum hard axis coercivity of 0.4 Oe was obtained when the number of layers was four. Maximum relative permeability was 2,900 when the number of layers was three. The cut off frequeocy of the multilayer films were above 100 MHz.

  • PDF

Chest CT Parameters to Predict the Major Adverse Events in Acute Submassive Pulmonary Embolism (혈역학적으로 안정된 폐색전증 환자에서의 임상적 악화를 예측하는 전산화 단층촬영상 소견)

  • Jung, Sang-Ku;Kim, Won-Young;Lee, Choong-Wook;Seo, Dong-Woo;Lee, Youn-Sun;Lee, Jae-Ho;Oh, Bum-Jin;Kim, Won;Lim, Kyoung-Soo;Hong, Sang-Bum;Lim, Chae-Man;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.3
    • /
    • pp.184-190
    • /
    • 2010
  • Background: The purpose of this study was to determine the prognostic significance of chest computed tomographic (CT) parameters in acute submassive pulmonary embolism (PE). Methods: Between January 2006 and December 2009, 268 consecutive patients with acute submassive PE that was confirmed by chest CT with pulmonary angiography in emergency room were studied. One experienced radiologist measured CT parameters and judged the presence of right ventricular dysfunction. CT parameters were analyzed to determine their ability to predict a major adverse event (MAE). Results: There were 220 patients included and 61 (27.7%) had MAE. Left ventricular and right ventricular maximum minor axis ($36.4{\pm}8.0$ vs. $41.7{\pm}7.4$, p<0.01; $45.7{\pm}9.4$ vs. $41.5{\pm}7.6$, p<0.01), superior vena cava diameter ($19.2{\pm}3.4$ vs. $18.0{\pm}3.4$, p=0.02), azygos vein diameter ($10.0{\pm}2.2$ vs. $9.2{\pm}2.3$, p=0.02), septal displacement (19 vs. 18, p<0.01) were significantly higher in MAE group than in no MAE group. Patients with MAE had high right ventricular/left ventricular dimension ratio (RV/LV ratio) compared to patients without MAE ($1.34{\pm}0.48$ vs. $1.03{\pm}0.28$, p<0.01). The most useful cut-off value of RV/LV ratio for MAE was 1.3 and the area under the curve was 0.71 (0.62~0.79). Conclusion: RV/LV ratio on chest CT was a significant predictor of submassive PE related shock, intubation, in-hospital mortality, thrombolysis, thrombectomy within 30 days.

LABORATORY EXPERIMENTS OF OFF-AXIS MIRROR OPTICS OF ALUMINUM FOR SPACE INFRARED MISSIONS

  • Oseki, Shinji;Oyabu, Shinki;Ishihara, Daisuke;Enya, Keigo;Haze, Kanae;Kotani, Takayuki;Kaneda, Hidehiro;Nishiyama, Miho;Abe, Lyu;Yamamuro, Tomoyasu
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.359-361
    • /
    • 2017
  • We report our research on aluminum mirror optics for future infrared astronomical satellites. For space infrared missions, cooling the whole instrument is crucial to suppress the infrared background and detector noise. In this aspect, aluminum is appropriate for cryogenic optics, because the same material can be used for the whole structure of the instrument including optical components thanks to its excellent machinability, which helps to mitigate optical misalignment at low temperatures. We have fabricated aluminum mirrors with ultra-precision machining and measured the wave front errors (WFEs) of the mirrors with a Fizeau interferometer. Based on the power spectral densities of the WFEs, we confirmed that the surface accuracy of all the mirrors satisfied the requirements for the SPICA Coronagraph Instrument. We then integrated the mirrors into an optical system, and examined the image quality of the system with an optical laser. As a result, the total WFE is estimated to be 33 nm (rms) from the Strehl ratio. This is consistent with the WFEs estimated from the measurement of the individual mirrors.

Dielectric Properties of Continuous Composition Spreaded $BaTiO_3-SrTiO_3$ Thin Films Prepared by Off-Axis RF Magnetron Sputtering System

  • Kim, Yoon-Hoe;Jung, Keun;Yoon, Seok-Jin;Park, Kyung-Bong;Choi, Ji-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.326-326
    • /
    • 2010
  • The dielectric properties of continuous composition spreaded (CCS) $BaTiO_3-SrTiO_3$ (BST) thin filmsgrown at room temperature and annealed at different temperature ($350^{\circ}C$ and $550^{\circ}C$) were investigated. Moreover, electrical properties (leakage current and breakdown voltage) of CCS BST thin films were also investigated. The aluminum top-electrode, sized by $200{\times}200\;{\mu}m2$ and apart from each other by $300\;{\mu}m$, were deposited on the CCS BST thin films by the DC sputtering system. The dielectric properties of the CCS BST thin films were significantly influenced depending on the distance from $BaTiO_3$ and $SrTiO_3$ targets which was attributed to the $BaTiO_3-SrTiO_3$ composition ratio. The maps of dielectric constants and loss tangents were plotted via $1500\;{\mu}m$ - step measuring. The specific points showing the dielectric constant (k: ~300) and loss tangent (tand: ~0.008) at 1 MHz were found.

  • PDF

Staggered and Inverted Staggered Type Organic-Inorganic Hybrid TFTs with ZnO Channel Layer Deposited by Atomic Layer Deposition

  • Gong, Su-Cheol;Ryu, Sang-Ouk;Bang, Seok-Hwan;Jung, Woo-Ho;Jeon, Hyeong-Tag;Kim, Hyun-Chul;Choi, Young-Jun;Park, Hyung-Ho;Chang, Ho-Jung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.4
    • /
    • pp.17-22
    • /
    • 2009
  • Two different organic-inorganic hybrid thin film transistors (OITFTs) with the structures of glass/ITO/ZnO/PMMA/Al (staggered structure) and glass/ITO/PMMA/ZnO/Al (inverted staggered structure), were fabricated and their electrical and structural properties were compared. The ZnO thin films used as active channel layers were deposited by the atomic layer deposition (ALD) method at a temperature of $100^{\circ}C$. To investigate the effect of the substrates on their properties, the ZnO films were deposited on bare glass, PMMA/glass and ITO/glass substrates and their crystal properties and surface morphologies were analyzed. The structural properties of the ZnO films varied with the substrate conditions. The ZnO film deposited on the ITO/glass substrate showed better crystallinity and morphologies, such as a higher preferred c-axis orientation, lower FWHM value and larger particle size compared with the one deposited on the PMMA/glass substrate. The field effect mobility ($\mu$), threshold voltage ($V_T$) and $I_{on/off}$ switching ratio for the OITFT with the staggered structure were about $0.61\;cm^2/V{\cdot}s$, 5.5 V and $10^2$, whereas those of the OITFT with the inverted staggered structure were found to be $0.31\;cm^2/V{\cdot}s$, 6.8 V and 10, respectively. The improved electrical properties for the staggered OITFTs may originate from the improved crystal properties and larger particle size of the ZnO active layer.

  • PDF

Optimization of exposure parameters and relationship between subjective and technical image quality in cone-beam computed tomography

  • Park, Ha-Na;Min, Chang-Ki;Kim, Kyoung-A;Koh, Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.49 no.2
    • /
    • pp.139-151
    • /
    • 2019
  • Purpose: This study was performed to investigate the effect of exposure parameters on image quality obtained using a cone-beam computed tomography (CBCT) scanner and the relationship between physical factors and clinical image quality depending on the diagnostic task. Materials and Methods: CBCT images of a SedentexCT IQ phantom and a real skull phantom were obtained under different combinations of tube voltage and tube current (Alphard 3030 CBCT scanner, 78-90 kVp and 2-8 mA). The images obtained using a SedentexCT IQ phantom were analyzed technically, and the physical factors of image noise, contrast resolution, spatial resolution, and metal artifacts were measured. The images obtained using a real skull phantom were evaluated for each diagnostic task by 6 oral and maxillofacial radiologists, and each setting was classified as acceptable or unacceptable based on those evaluations. A statistical analysis of the relationships of exposure parameters and physical factors with observer scores was conducted. Results: For periapical diagnosis and implant planning, the tube current of the acceptable images was significantly higher than that of the unacceptable images. Image noise, the contrast-to-noise ratio (CNR), the line pair chart on the Z axis, and modulation transfer function (MTF) values showed statistically significant differences between the acceptable and unacceptable image groups. The cut-off values obtained using receiver operating characteristic curves for CNR and MTF 10 were useful for determining acceptability. Conclusion: Tube current had a major influence on clinical image quality. CNR and MTF 10 were useful physical factors that showed significantly associations with clinical image quality.

Evaluation of beam delivery accuracy for Small sized lung SBRT in low density lung tissue (Small sized lung SBRT 치료시 폐 실질 조직에서의 계획선량 전달 정확성 평가)

  • Oh, Hye Gyung;Son, Sang Jun;Park, Jang Pil;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.7-15
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate beam delivery accuracy for small sized lung SBRT through experiment. In order to assess the accuracy, Eclipse TPS(Treatment planning system) equipped Acuros XB and radiochromic film were used for the dose distribution. Comparing calculated and measured dose distribution, evaluated the margin for PTV(Planning target volume) in lung tissue. Materials and Methods : Acquiring CT images for Rando phantom, planned virtual target volume by size(diameter 2, 3, 4, 5 cm) in right lung. All plans were normalized to the target Volume=prescribed 95 % with 6MV FFF VMAT 2 Arc. To compare with calculated and measured dose distribution, film was inserted in rando phantom and irradiated in axial direction. The indexes of evaluation are percentage difference(%Diff) for absolute dose, RMSE(Root-mean-square-error) value for relative dose, coverage ratio and average dose in PTV. Results: The maximum difference at center point was -4.65 % in diameter 2 cm size. And the RMSE value between the calculated and measured off-axis dose distribution indicated that the measured dose distribution in diameter 2 cm was different from calculated and inaccurate compare to diameter 5 cm. In addition, Distance prescribed 95 % dose($D_{95}$) in diameter 2 cm was not covered in PTV and average dose value was lowest in all sizes. Conclusion: This study demonstrated that small sized PTV was not enough covered with prescribed dose in low density lung tissue. All indexes of experimental results in diameter 2 cm were much different from other sizes. It is showed that minimized PTV is not accurate and affects the results of radiation therapy. It is considered that extended margin at small PTV in low density lung tissue for enhancing target center dose is necessary and don't need to constraint Maximum dose in optimization.

Development of 3-D Stereotactic Localization System and Radiation Measurement for Stereotactic Radiosurgery (방사선수술을 위한 3차원 정위 시스템 및 방사선량 측정 시스템 개발)

  • Suh, Tae-Suk;Suh, Doug-Young;Park, Sung-Hun;Jang, Hong-Seok;Choe, Bo-Young;Yoon, Sei-Chul;Shinn, Kyung-Sub;Bahk, Yong-Whee;Kim, Il-Hwan;Kang, Wee-Sang;Ha, Sung-Whan;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.25-36
    • /
    • 1995
  • The purpose of this research is to develop stereotactic localization and radiation measurement system for the efficient and precise radiosurgery. The algorithm to obtain a 3-D stereotactic coordinates of the target has been developed using a Fisher CT or angio localization. The procedure of stereotactic localization was programmed with PC computer, and consists of three steps: (1) transferring patient images into PC; (2) marking the position of target and reference points of the localizer from the patient image; (3) computing the stereotactic 3-D coordinates of target associated with position information of localizer. Coordinate transformation was quickly done on a real time base. The difference of coordinates computed from between Angio and CT localization method was within 2 mm, which could be generally accepted for the reliability of the localization system developed. We measured dose distribution in small fields of NEC 6 MVX linear accelerator using various detector; ion chamber, film, diode. Specific quantities measured include output factor, percent depth dose (PDD), tissue maximum ratio (TMR), off-axis ratio (OAR). There was small variation of measured data according to the different kinds of detectors used. The overall trends of measured beam data were similar enough to rely on our measurement. The measurement was performed with the use of hand-made spherical water phantom and film for standard arc set-up. We obtained the dose distribution as we expected. In conclusion, PC-based 3-D stereotactic localization system was developed to determine the stereotactic coordinate of the target. A convenient technique for the small field measurement was demonstrated. Those methods will be much helpful for the stereotactic radiosurgery.

  • PDF

Dosimetry and Three Dimensional Planning for Stereotactic Radiosurgery with SIEMENS 6-MV LINAC (6-MV선형가속기를 이용한 입체방사선수술의 선량측정 및 3차원적 치료계획)

  • Choi Dong-Rak;Cho Byong Chul;Suh Tae-Suk;Chung Su Mi;Choi Il Bong;Shinn Kyung Sub
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.175-181
    • /
    • 1993
  • Radiosurgery requires integral procedure where special devices and computer systems are needed for localization, dose planning and treatment. The aim of this work is to verify the overall mechanical accuracy of our LINAC and develop dose calculation algorithm for LINAC radiosurgery. The alignment of treatment machine and the performance testing of the entire system were extensively carried out and the basic data such as percent depth dose, off-axis ratio and output factor were measured. A three dimensional treatment planning system for stereotactic radiosurgery has been developed. We used an IBM personal computer with C programming language (IBM personal system/2, Model 80386, IBM Co., USA) for calculating the dose distribution. As a result, deviations at isocenter on gantry and table rotation for our treatment machine were acceptable since they were less than 2 mm. According to the phantom experiments, the focusing isocenter were successful by the error of less than 2 mm. Finally, the mechanical accuracy of our three dimensional planning system was confirmed by film dosimetry in sphere phantom.

  • PDF