• 제목/요약/키워드: Odorous gas

검색결과 61건 처리시간 0.022초

냉각 제습에 의한 음식물 쓰레기 처리장치 악취제거에 관한 실험적 연구 (A Study on an experimental basis a use deodorize stink of food-waste in order to cooling dehumidification)

  • 박일수;김재돌
    • 동력기계공학회지
    • /
    • 제12권1호
    • /
    • pp.35-40
    • /
    • 2008
  • This paper presents an effective cooling dehumidification method to remove odorous gas from food-wastes. The odorous gases, such as Styrene, Ammonia, Hydrogen sulfide and Acetaldehyde, are produced in environments where temperature is $50\sim80^{\circ}C$ and humidity is $40\sim70%$. Under such conditions, experiments are performed reiteratively using experiment equipments. The effect of the cooling dehumidification is measured via measuring instrument, and this research is focused on improving efficiency. The effect of cooling dehumidification using measuring instrument is validated. At $80^{\circ}C$, four type of gases that was mentioned previously showed generally better cooling efficiency with a good result for a component concentration. Among them, hydrogen sulfide gas demonstrated the highest reduction of 50%.

  • PDF

Aqeous Neutralizer as Reactive Solvents for Odorous Ammonia Removal

  • Park, Young-G.
    • Environmental Engineering Research
    • /
    • 제13권3호
    • /
    • pp.119-124
    • /
    • 2008
  • Ammonia is an inorganic compound that may cause severe odor problem. In this study the effectiveness of applying natural neutralizer to destroy and remove the odor-causing compound from gas streams was studied. Experimental result evaluated with a bench-scale apparatus via the neutralization of gas phase. This indicates that the natural neutralization depends on the gas concentration, gas residence time, temperature and pH. Removal efficiency of ammonia from gas stream was achieved by 95% using theconvection in the packed bed. This study proved the chemical neutralization technology was effective for controlling inorganic odor-causing compound.

제과공장의 폐수처리장에서 발생하는 악취 저감 (Reduction of the Offensive Odor from Confectionery Wastewater Plant)

  • 김영식;손병현;조상원;정종현
    • 한국환경보건학회지
    • /
    • 제24권1호
    • /
    • pp.62-69
    • /
    • 1998
  • It has been studied that the measurement of odor component emission at confectionery manufacture. The objects of this study were to investigate reduction of offensive odor. The survey effects of odorous materials are presented as follows. The countermeasure of operating process is to minimize sludge sediment in each unit facility. Especially, in summer, we have to clean the sludge frequently, because anaerobic decomposing is likely to occur easily. The sludge or scum from sedimentation tank pond, and floating tank should be treated quickly. We should avoid overloading operation. In the case of overloading, dissolved oxygen should be increased, the quality of wastewater input should be decreased. When dried cakes from condense tank or floating tank are left in treatment plant, we should cover, to prevent diffusion of smell with masking materials. The seasonal condition of operating should be fixed and the kind of coagulants should be changed because the wastewater in each season have different loading rates and organic materials. Odorous materials are very sensitive to the seasonal temperature variation. Especially, when the amount of rainfall is small and the high temperature of maintenance in long periods, air diffusion rate is large, so odorous materials can make great effect on surroundings comparision with other periods. To reduce odorous gas, as short term method, we had better take ceramic addition method. Especially, in summer we should take ceramic addition method. Also, as long term method, the size of wastewater treatment facility is the most important in the normal operating of wastewater treatment facility. But wastewater treatment facilities in this factory are too old, treatment process is old fashion, and the size is too small. So, large wastewater quantity to treat in summer. As results, the expansion of wastewater treatment facility and the process of improvement are required. Restriction level of odor was exceed. As it is overloaded in summer, the basis cause of odor is that the size of wastewater treatment facility is small. The prediction of air quality equilibrium density variation show that the odorous materials from working place are Amine materials whose smell strength is about 2.5(a little strong degree). We can suppose that in summer is sensitive to temperature variation, smell strength is larger as to reduce the origin of odor. We must expand wastewater treatment facility and improve the process A.S.A.P.

  • PDF

GNC용액을 이용한 음식물 쓰레기처리장에서 발생되는 악취 규제물질 제거 효과에 관한 연구 (By the GNC Solution, Removal Effect Offensive Odorous Compounds Generated from Food)

  • 홍종순;김재우
    • 환경위생공학
    • /
    • 제22권2호
    • /
    • pp.35-40
    • /
    • 2007
  • It disposes positively in the air pollution damage which is serious, in order help period the place where it improves the quality of existence and life of the local residents. It removed the offensive odor regulation material and the technique it will be able to prevent to sleep it researched it did. After scattering the GNC solution which develops the offensive odor regulation material which occurs from the food and trash treatment plant which is located to the S from the H, company after scattering the GNC solution which it develops collection it did a control criminal record control kind air and it analyzed. In this study, we investigated the emission concentrations of offensive odorous compounds of hydrogen sulfide, methyl mercaptan, dimethyl sulfide and dimethyl disulfide, trimethylamine, formaldehyde, acetaldehyde, propionaldehyde, buthylaldehyde, iso-valeric aldehyde, n-valeric aldehyde, ammonia. The concentrations of odorous compounds are determined by gas chromatography, HPLC and uv-vis spectroscopy. Hydrogen sulfide, methyl mercaptan, dimethyl sulfide and dimethyl disulfide were not detected at any point examined.

합판 제조용 목재 건조공정에서의 휘발성 유기화합물(VOCs) 배출특성 (Emission Characteristics of VOCs in Drying Process for Plywood Manufacturing)

  • 장정국;김미란
    • 한국환경과학회지
    • /
    • 제17권12호
    • /
    • pp.1381-1390
    • /
    • 2008
  • Emission characteristics of volatile organic compounds (VOCs) were investigated in the flue gas emitted from wood drying process for plywood manufacturing. The moisture content of raw timber was average 48%, and its density was $831.55kg/m^3$. But the moisture content of dried wood is needed less than around 10%, thus the moisture contents of flue gas should be remarkably high(about 18.2 V/V%). Therefore, the vapor in flue gas is equivalent to 320 ton-vapor/day when 1100 ton-wood/day is treated in the wood drying process. The temperature of flue gas ranges from $140^{\circ}C\;to\;150^{\circ}C$ in each dryer stack with exception of the input site of wood(about $110^{\circ}C$). The velocity of flue gas in each stack ranges from 1.7 to 9.7m/sec. In order to assess the concentrations and attribution rate of odorous compounds, it was analyzed about 40 VOCs in the flue gases. It was found that the major odorous compounds were 8 compounds, and the concentrations of major VOCs(ppm) were as follows; benzene: $0.054{\sim}0.052$, toluene: $1.011{\sim}2.547$, ethylbenzene: $0.472{\sim}2.023$, m,p-xylene: $0.504{\sim}3.245$, styrene: $0.015{\sim}0.148$, o-xylene : $0.271{\sim}1.097$, ethanol: $11.2{\sim}32.5$, ${\alpha}$-pinene: $0.908{\sim}10.578$, ${\beta}$-pinene: $0.982{\sim}14.278$. The attribution rate of terpenes (${\alpha}$-pinene, ${\beta}$-pinene) was about 60.56%, and that of aromatics and alcohols was about 22.77%, and 16.67%, respectively. It is suggested that the adequate control device should be used to control both the water soluble and non-soluble compounds because both compounds were mixed in flue gas.

생활폐기물 자동집하시설의 악취물질 배출특성 (Emission Characteristics of Odor Compounds from Pneumatic Waste Collection Plants)

  • 윤용경;김대근
    • 대한환경공학회지
    • /
    • 제34권8호
    • /
    • pp.541-548
    • /
    • 2012
  • 본 연구에서는 생활폐기물 자동집하시설에서의 악취물질 배출특성을 파악하고자 2개소(A시설, B시설)의 시설을 선정하여 공기관로 내의 이송가스와 최종배출가스를 대상으로 복합악취와 22종의 지정악취물질을 조사하였다. 생활폐기물 자동집하시설에서 배출되는 주된 악취물질은 암모니아, 황 화합물, 아세트알데하이드이었으며, 악취처리공정의 종류에 따라 최종배출구의 악취 배출특성이 상이하였다. 이송가스를 대상으로 한 악취기여도 평가에서는 A시설의 경우, 디메틸설파이드 26%, 아세트알데하이드 18%, 메틸머캅탄 14%의 악취기여도를 보였으며, B시설의 경우에는 메틸머캅탄 56%, 황화수소와 디메틸설파이드가 각각 15%이었다.

안산시 주거지역을 중심으로 한 환경대기 중 휘발성 유기화합물과 황계열 성분의 온라인 연속측정 연구 (On-line GC Analysis of Odorous VOC and S Gas Pollutant Levels in Ambient Air of a Residential Area at Ansan City, Korea)

  • 김기현;주도원;최여진;홍윤정;사재환;박종호;전의찬;최청렬;구윤서
    • 한국대기환경학회지
    • /
    • 제21권1호
    • /
    • pp.107-118
    • /
    • 2005
  • In this study, the concentrations of major odorous compounds including reduced sulfur compounds (OMS, CS$_2$, and DMDS) and aromatic VOC (benzene, toluene, xylene, etc.) were measured continuously using an on-line GC analytical system. Our measurements were made from a residential area of Ansan sity during about two week period of October, 2004. The highest mean concentrations of Sand VOC were found as 56.9 pbb of DMS and 21.7 ppb of toluene, respectively. The results of this study generally show that the pollution levels for both types of chemicals are significant relative to previous measurement results reported from comparable sites, if the results are compared simply in terms of the magnitude of the measured concentration data. Moreover, when the relative importance of different compounds is compared in terms of the odor strength, it indicated that the contribution of reduced S compounds may be much more important than that of VOC in the study area.

퇴비 및 폐타이어 Granule을 이용한 악취 제거 (Odor Removal by Using Compost and Granular Scrap Tires)

  • 정윤진
    • 상하수도학회지
    • /
    • 제13권1호
    • /
    • pp.43-50
    • /
    • 1999
  • In spite of low energy requirement, and operation and construction cost, biofilters with soil beds have not been operated efficiently. Because of excess moisture in winter and rainy periods, saturated pores in the bed prevent passage and sorption of odorous compounds. Sometimes this results in septic conditions that release previously sorbed and oxidized sulfur. Therefore, an economical and effective alternative needs to be developed. The objectives of this study were to confirm applicability of the granular scrap tires with compost for treating odorous gas as well as to obtain optimum design parameters for proposed system. In lab-scaled test, multiple stage reactors had lower headloss than a single stage reactor and less headloss was occurred for the gas with higher moisture content. For practical purpose, pilot-scaled reactor was operated to remove odor from septic tank, manure and animal wastewater treatment plant and composting machine. According to the results of pilot scaled test, $H_2S$ can be always removed completely and ammonia/amine can be removed excellently when proper moisture content is provided. The results from lab and pilot test showed that granular scrap tire could be replaced with soil as supporting material for biofilter showed excellent drainage because of its ability to reject moisture.

  • PDF

Decomposition of Odorous Gases in a Pilot-scale Nonthermal Plasma Reactor

  • Hwang, Yoon-Ho;Jo, Young-Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제21권E2호
    • /
    • pp.57-65
    • /
    • 2005
  • An experimental study was performed on the decomposition of gaseous ammonia and two selected volatile organic compounds (VOCs: toluene and acetone) in a combined nonthermal plasma reactor with corona and glow discharges. A lab pilot scale reactor (206 liter) equipped with a high electric power pack was used to determine the decomposition efficiency in relation with the inlet concentration and applied voltage. Three different types of discharging electrode such as wired rack, wire strings for corona discharge, and thin plate for glow discharge were put in order in the reactor. While decomposition of ammonia decreased with an increase in the initial concentration, acetone showed an opposite result. In the case of toluene however no explicit tendency was found in toluene and aceton. Negative discharge resulted in high decomposition efficiency than the positive one for all gases. A better removal of gas phase element could be achieved when fume dust were present simultaneously.

Triple-bed Adsorbent Tube를 이용한 가스상 극미량 복합 악취 및 휘발성 유기화합물의 동시 분석 (Simultaneous Analyses for Trace Multi-Odorous and Volatile Organic Compounds in Gas using a Triple-bed Adsorbent Tube)

  • 서용수;이제근
    • Korean Chemical Engineering Research
    • /
    • 제48권2호
    • /
    • pp.244-252
    • /
    • 2010
  • 본 연구에서는 Triple-bed 흡착튜브를 제작하여 열탈착장치와 GC-MS로써 다성분 복합 악취성물질 및 휘발성유기 화합물을 동시분석 가능성을 평가하고자 하였다. Triple-bed 흡착튜브는 하나의 튜브에 Tenax-TA와 소량의 Carbopack B 및 Carbosieve SIII 흡착제를 흡착강도 순으로 3단 배열된 것이다. GC-MS의 분석조건은 mass range 20~350 m/z, 불순물 1 ppm 이하의 헬륨을 운반가스로 하여 저비점 저분자량 물질의 분리동정에 효과적일 수 있도록 하고, 목적이온 추출을 통하여 정량하였다. 그 결과 ppbv 수준의 $C_1{\sim}C_5$의 알콜(4), 알데히드(6), 케톤(2) 그리고 황화합물(2)을 포함한 14종의 물질 모두 99%이상의 회수율과 양호한 재현성 및 직진성으로 동시분석이 가능하였다. 비교적 휘발성이 강하고 분자량이 낮은 물질인 메틸알콜, 아세트알데히드는 상대습도 45% 이하, 흡착유속 50 mL/min, 흡착량 2 L 이하에서 높은 회수율로 보다 안정적으로 정량분석이 가능하였다. 또한 목적이온 추출은 물질피크가 겹쳐 나타난 경우에도 다성분 물질을 각각 정량 가능하였다.