축산농가에서 목초액을 이용한 암모니아 가스의 제거 특성에 관한 연구 (Ammonia Removal Characteristics by Pyroligneous Liquid at Livestock Farmhouse)

  • 박정호;전기일;정창훈
    • 한국환경과학회지
    • /
    • 제12권12호
    • /
    • pp.1309-1313
    • /
    • 2003
  • This study was carried out to obtain the optimal ammonia removal efficiency using pyroligenous liquid for the economical and environment-friendly odor removal at a petty livestock farmhouse. The ammonia removal efficiencies were evaluated due to changing dilution rates(${\times}$10, ${\times}$20, ${\times}$30, ${\times}$50 and ${\times}$100 times) and different spray amounts(10$m\ell$ and 20$m\ell$) of pyroligenous liquid. The wet scrubber device was used to remove odor in closed-type livestock farmhouse. According to dilution rate of the pyroligenous liquid, the optimum rate was 20 times and the removal efficiency increased by decreasing dilution rates. In the case of spray amounts with the optimum dilution, the amount was 20 me and the removal efficiency increased by increasing spray amount. Also, the removal efficiency by using wet deodorizing device was 83.0-97.0% with 20 times diluted liquid.

강변여과에 의한 이.취미 물질 제어 특성에 관한 타당성 연구 (A Feasibility study on Removal Characteristics of Taste and Odor using Bank Filtration Treatment)

  • 맹승규;박노석;임재림;김성수;정우창
    • 상하수도학회지
    • /
    • 제24권3호
    • /
    • pp.307-317
    • /
    • 2010
  • This study was conducted in order to investigate bulk organic matter characteristics and behavior of geosmin and 2-methylisoborneol (2-MIB) during riverbank filtration, which are general surrogates of taste and odor in drinking water. Column studies were used to simulate bank filtration systems. Most of the aliphatic organic matter was removed effectively after soil passage, and it is believed to be polysaccharides according to LC-OCD and F-EEM analysises. Removal efficiencies of geosmin and 2-MIB within the filtration column reached above 95%. It was found that the removal of total dissolved organic matter has a correlation with that of geosmin and 2-MIB in the near of filtration surface (about 50cm).

매립지 메탄 및 악취 배출 저감을 위한 바이오커버 및 바이오필터의 현장적용 평가 연구 (Evaluation of field application of biocover and biofilter to reduce landfill methane and odor emissions)

  • 채정석;전준민;오경철;류희욱;조경숙;김신도
    • 실내환경 및 냄새 학회지
    • /
    • 제16권2호
    • /
    • pp.139-149
    • /
    • 2017
  • In order to reduce odor and methane emission from the landfill, open biocovers and a closed biofilter were applied to the landfill site. Three biocovers and the biofilter are suitable for relatively small-sized landfills with facilities that cannot resource methane into recovery due to small volumes of methane emission. Biocover-1 consists only of the soil of the landfill site while biocover-2 is mixed with the earthworm casts and artificial soil (perlite). The biofilter formed a bio-layer by adding mixed food waste compost as packing material of biocover-2. The removal efficiency decreased over time on biocover-1. However, biocover-2 and the biofilter showed stable odor removal efficiency. The rates of methane removal efficiency were in order of biofilter (94.9%)>, biocover-1(42.3%)>, and biocover-2 (37.0%). The methane removal efficiency over time in biocover-1 was gradually decreased. However, drastic efficiency decline was observed in biocover-2 due to the hardening process. As a result of overturning the surface soil where the hardening process was observed, methane removal efficiency increased again. The biofilter showed stable methane removal efficiency without degradation. The estimate methane oxidation rate in biocover-1 was an average of 10.4%. Biocover-2 showed an efficiency of 46.3% after 25 days of forming biocover. However, due to hardening process efficiency dropped to 4.6%. After overturn of the surface soil, the rate subsequently increased to 17.9%, with an evaluated average of 12.5%.

맥동식 침전지에서 맛·냄새 유발물질 제거 특성 (Removal Property of Taste and Odor Causing Material in Pulsator Clarifier)

  • 정일용;차민환
    • 한국물환경학회지
    • /
    • 제27권1호
    • /
    • pp.104-109
    • /
    • 2011
  • The removal efficiencies of 2-methylisoborneol (MIB) and geosmin were investigated to reveal removal characteristics of typical organic compounds causing disagreeable taste and odor at the conventional water treatment plant installed with pulsator clarifier patented by the French company $Degr{\acute{e}}mont$. The injection rate of Powdered Activated Carbon (PAC) into water was changed step wisely as we conducted jar tests in the laboratory and water treatment in the actual plant. 2-MIB concentration decreased linearly while geosmin did exponentially along with the injection rate of PAC at our jar tests. The removal efficiency of geosmin by PAC injection was considerably higher than that of 2-MIB. In the real pulsator clarifier, 2-MIB concentration started decreasing as the injection rate reached up to 10 mg/L of PAC. On the other hand, the concentration of geosmin in water decreased proportional to the injection rate of PAC. In the sand filtration, removal efficiencies of 2-MIB and geosmin on July were much higher than those on March. It was carefully suggested beforehand and found afterwards that general microorganisms notably existed in the sand filter with no chlorine in filter influent and backwash water and the sand filter biologically activated removed much more odor compounds. It was considered as the reason why the removal efficiency of 2-MIB and geosmin was increased. The microbial activity maybe increased in summer with water temperature rising and low filtration rate possibly increased contact time between odor compounds and general microorganisms.

Pulse UV 장치를 이용한 먹는 물의 이취미 유발물질 제거효과에 관한 연구 (Removal of taste and odor causing compounds in drinking water using Pulse UV System)

  • 손진식;박순호;정의택
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.219-228
    • /
    • 2012
  • Problems due to the taste and odor in drinking water are common in treatment facilities around the world. Taste and odor are perceived by the public as the primary indicators of the safely and acceptability of drinking water, and are mainly caused by the presence of two semi-volatile compounds-2-methylisoborneol(2-MIB) and geosmin. Conventional treatment processes in water treatment plants, such as coagulation, sedimentation and chlorination have been found to be ineffective for the removal of 2-MIB and geosmin. Pulse UV system is a new UV irradiation system that is a non-mercury lamp-based alternative to currently used continuous wave systems for water disinfection. This study shows pulse UV system to be effective in treatment of these two compounds. Geosmin removal efficiency of UV process alone achieved approximately 70% at 10sec contact time. 2-MIB removal efficiency of UV only process achieved approximately 60% at 10sec contact time. The addition of $H_{2}O_{2}$ 7mg/L increased geosmin and 2-MIB removal efficiency upto approximately 94% and 91%, respectively.

습식세정장치에서 발생되는 마이크로버블을 이용한 음식물쓰레기 발생 복합악취 처리 (Complex Mal-odor Treatment of Foodwaste with Micro-bubble generated from Enhanced Wet Scrubber)

  • 김예진;정재억;정용준
    • 한국환경과학회지
    • /
    • 제24권1호
    • /
    • pp.73-79
    • /
    • 2015
  • The objective of this work was to treat complex mal-odor of food waste with micro-bubbles from enhanced wet scrubber system, where the pilot plant was operated. Micro bubbles from the enhanced reactor of venturi scrubber were successfully generated through the air atomizing process with high velocity more than 60 m/sec and played an important role in the removal of mal-odor. Mal-odor was effectively changed into the micro-bubble and treated with washing chemicals together. Through establishing two series connection of the reactors, 85.2 % removal efficiency of complex mal-odor was obtained in case of average 940 times of input air. 0.35 kg/hr of sulfuric acid, 0.188 kg/hr of sodium hydroxide and 0.043 kg/hr of hypochlorite were injected for chemical washing.

미세 분무유 제거를 위한 신개념 특수필터 설계 (New Design of Cap Type Filter for Oil Mist Removal)

  • 김홍건
    • 한국생산제조학회지
    • /
    • 제20권1호
    • /
    • pp.13-16
    • /
    • 2011
  • It is a tendency where the number of the restaurant is increasing recently with advancement of the food service industry. In comparison, Noxiousness fine MIST and the removal are passively done in about offensive odor which occurs meat products processing as emitting like that in the atmosphere. Because adherence lamination in the exhaustion line pipe has need of a periodic cleaning and change, it must discontinue the business of long time. In this paper, The technique development on fine MIST, dust of offensive odor and filtering which occur meat products processing prevents adherence/lamination of fine MIST in exhaustion line pipe. And the source prevents the environmental matter which is emitted in the atmosphere under maximizing boil offensive odor and the filtering effect of noxiousness MIST.

고주파 연면방전체를 이용한 $NH_3$ 처리성능에 관한 연구 (A Study on Removal Performance of $NH_3$ Odor Gas Using High Frequency Surface Discharge Body)

  • 이주상
    • 환경위생공학
    • /
    • 제11권1호
    • /
    • pp.9-15
    • /
    • 1996
  • The purpose of this study was to evaluate the decomposition efficiency of $NH_3$ odor gas using high frequency surface discharge body. The results from this study are as follows; 1, Voltage and frequency of electric elements have effects on removal of $NH_3$ odor. The higher these two elements were set up, the more efficiently deodorizing processing worked. In this experiment, the optimum voltage and frequency applicable were observed around AC 6.0 kVp-p and 24.0 kHz respectively. 2. The temperature, humidity and residence time were observed strong variables for NH$_3$ removal process. Its performance had limits at high temperature and humidity conditions. The longer the residence time continued, the more efficiently deodorization process worked. The experimental results showed that the deodorization was efficiently processed under such conditions as $30.0^{\circ}C$ in temperature, 60rh% in humidity and 0.3 sec in residence time. 3. It was observed that in deodorization experiment, $NH_3$ odor gas was perfectly decomposed under the concentration condition below 15.0ppm. Moreover it was considered as economic and practical in terms of maintenance cost when compared with other deodorization methods.

  • PDF

FRP제품 가공시 발생하는 분진 및 악취 제거 시스템 개발 (System Development of Removing Dust and Odor from Manufacturing Process of FRP Products)

  • 윤희관;김재용
    • 공업화학
    • /
    • 제20권5호
    • /
    • pp.547-552
    • /
    • 2009
  • 본 연구에서는 fiber reinforced plastics (FRP) 제품 가공시 발생하는 분진 및 악취 물질로 인한 작업현장의 악조건을 개선하기 위하여 activated carbon fiber (ACF) 장착 하이브리드 백필터를 개발하였다. FRP 제조업체 2개사에 ACF 백필터를 설치함에 있어 천장, 벽하단 부분에 덕트를 설치함은 물론 이동식 집진 덕트를 설치함으로써 집진효율을 높였다. 펄스젯트식 탈진방식을 채택하여 효과적인 시스템 운영을 유도함으로써 작업환경을 개선하고자 하였다. 하이브리드 백필터 시스템 운용시 이에 따르는 분진과 악취에 대한 제거동향을 고찰하였다.

Analysis on an Oxidation-Reduction Reaction of Photocatalytic Plasma Complex Module

  • KIM, Young-Do;KWON, Woo-Taeg
    • 웰빙융합연구
    • /
    • 제5권2호
    • /
    • pp.21-27
    • /
    • 2022
  • Purpose: This study is about photocatalytic technology and plasma oxidation-reduction technology. To the main cause of exposure to odor pollution, two deodorization techniques were applied to develop a module with higher removal efficiency and ozone reduction effect. Research design, data and methodology: A composite module was constructed by arranging two types of dry deodorization equipment (catalyst, adsorbent) in one module. This method was designed to increase the responsiveness to the components of complex odors and the environment. standard, unity, two types of oxidizing photo-catalyst technology and plasma dry deodorization device installed in one module to increase the potential by reduction to 76% of ozone, 100%, and 82%. Results: The complex odor disposal efficiency was 92%. Ammonia was processed with 50% hydrogen sulfide and 100% hydrogen sulfide, and ozone was 0.01ppm, achieving a target value of 0.07ppm or less. The combined odor showed a disposal efficiency of 93%, ammonia was 82% and hydrogen sulfide was 100% processed, and ozone achieved a target value of 0.07 ppm or less. Conclusions: Ozone removal efficiency was 76% by increasing Oxidation-Reduction Reaction(ORR). The H2S removal efficiency of the deodorizer was higher than that of the biofilter system currently used in sewage disposal plants.