• 제목/요약/키워드: Odor Control

검색결과 421건 처리시간 0.024초

숯 제조시설의 악취물질 배출특성과 관리실태 조사 연구 (Evaluation of Malodor Release and Control Devices in Charcoal Manufacturing Facility)

  • 정주영;서병량;김재혁;진성민;정종수
    • 한국환경과학회지
    • /
    • 제21권7호
    • /
    • pp.883-890
    • /
    • 2012
  • Emission characteristics of gaseous odor compounds emitted from the charcoal manufacturing process were investigated, and evaluated the odor removal efficiency of odor control devices. It was found that the measured odor dilution ratio of emission gases ranged from 10,000 to 44,814, which exceed largely the emission standard in the stack. Methylmercaptan, trimethylamine, hydrogen sulfide, acetaldehyde were turned out as major odor compounds of the charcoal manufacturing process. It was revealed that the odor removal ratio of odor control devices were very low due to the its improper maintenance and wrong design.

악취관리제도의 국가간 비교연구 (A Comparative Study for Odor Control Regulations)

  • 양성봉;김석만
    • 한국대기환경학회지
    • /
    • 제16권1호
    • /
    • pp.79-87
    • /
    • 2000
  • This study analyzed the regulations concerning odor management or control in Korea, Japan, and developed countries such as USA and Germany. The Korean restriction standards and measurement methods for offensive odor substances are very similar to the Japanese standards and methods promulgated in 1976. Japan promulgated the odor control act and the specific measurement methods of the offensive odor substances in 1973. In Japan, currently, the local governments can establish their own odor restriction areas and proclaim their own standards suitable for their situations. Also, Japan has more strict regulations and more offensive odor substances to be monitored than Korea. The restriction standards of odor in German is quite similar to the permissible limits and standards of air pollutants at emission sources in Korea. Many states in USA are adopting their own restriction standards and measurement methods, e.q., the ambient air pollution standards, organic functionstest methods by dilation, and establishment and addition of air pollution control equipment at emission sources. Finally, this study analyzed the problems of the regulations, standards, and measurement methods concerning the Korean offensive odor management. Since the direct organic fuctions measurement(DOFMM) method is depending upon the personal sensitives of odor substances, the measurement odor value can be equivocal. That is, the odor measurement value by an examines can differ from that by the other examines. Also, there can be conflicts with the measured odor values depending upon the applied measurement methods, e.q., the DOFMM, the dilation method, and the instrumental analysis method.

  • PDF

양돈시설 내부의 악취조졸에 관한 기술 및 연구동향 (A Review of the Odor Control From Inside of Swine Production Facilities)

  • 김두환;김인배
    • 한국축산시설환경학회지
    • /
    • 제5권3호
    • /
    • pp.203-216
    • /
    • 1999
  • Recent public concern about air pollution caused by swine production facilities has forced to develop the methods to reduce and control the swine odors. Swine odors were affected the life of pig farm neighborhoods, swine productivity, pig health, diseases, and human right, safety, sanity as negatively. The first approaches of control of swine odors are the change or improve of the classical management systems, which are manure treatment method, manure storage facility, phase feeding, sex-divided feeding, feeder type, liquid-slurry feeding, environment control of swine building and dust control of indoor swine facility. The methods to control odor emission from manure have to include the diet modification as nutritional basis. In recent, research emphasis has focused on manipulating the swine diet to increase the nutrient utilization of the diet to reduce excretion products and reduction of odors. There are lots of feed additives and pit additives introduced as practical basis for reducing odor emissions. The ozone treatment method is candidate as the good system for reducing swine odor. But this system is still too expensive to practice in present.

양돈 분뇨의 악취특성 및 문제 해결을 위한 환경개선제 사용 현황 및 전망 (Current Status and Perspectives of Livestock Environment Improving Agents for the Characteristics and Control of Swine Manure Odor)

  • 이은영;임정수
    • 한국미생물·생명공학회지
    • /
    • 제38권3호
    • /
    • pp.244-254
    • /
    • 2010
  • The trend toward intensification of livestock raising, confinement in barn has increased in recent days. The move toward concentrated animal feeding operations reduces per unit costs and permits farmers to better earnings in spite of fluctuation in hog prices. However, this also results in outbreaks of a lot of animal wastes and odorous compounds. Emissions of these malodorous compounds produced from concentrated animal feeding operations have become a concern for both public and regulatory agencies and are causing the complaints of residents in rural area. For competitive sustainable swine production industry, odor management plans systematically identify potential odor sources, determine control strategies to reduce these odors, and establish criteria for implementing these strategies. Since, the malodor originates from microbial activities involving a variety of microbes, understanding the characteristics of the microflora present in swine manure is essential for developing effective odor control techniques. This paper reviews the available information in the literature related to the types of bacteria in swine manure, the potential odorous compounds associated with different bacterial genera, and the corresponding techniques used to control odor based on microbiological principles.

경기도 시화공단 지역주민의 악취오염과 관련된 건강영향 평가 (Health Effects from Odor Pollution in Sihwa Industrial Complex)

  • 조수헌;김선민;주영수;김재용;최성우
    • Journal of Preventive Medicine and Public Health
    • /
    • 제32권4호
    • /
    • pp.473-481
    • /
    • 1999
  • Objectives: In recent days, the problem of odor pollution in community near Sihwa Industrial complex, Kynuggi Province is becoming of significant public concern. We have investigated the health effects of the Sihwa residents from odor pollution comparing with other less polluted areas. Methods: The Ansan and Kuri Cities were selected as control areas. The parents of the elementary and middle school students in these three areas were surveyed with structured questionnaire twice, Nov 1997 and Jure 1998 each. As a exposure index, the ambient air concentrations of five major air pollutants(particulates, $O_3,\;SO_2,\;NO_2$, CO) and subjective odor perception were used. We have focused health outcomes such as the prevalence of nonspecific irritant symptoms, respiratory disease among family members and the score of qualify of life(QOL). Results: Although the mean concentrations of major air pollutants except particulates were similar or lower in Sihwa than other areas, the odor perception rate and the monthly odor perception days were significantly higher. It suggested that odor producing chemical compounds are the major source of environmental pollution problem. There were higher prevalence rates of nonspecific irritant symptoms and respiratory disease among family members in Sihwa than other control areas. The QOL score was also lower in Sihwa. The odor perception proved to be a most important factor in reporting adverse health effects and lowering the QOL score. Conclusion: The residents living near Sihwa industrial complex were suffering from more adverse health symptoms and poorer QOL status than control areas. And it may be due to environmental odor pollution from industrial complex. Therefore, further research will be needed for monitoring of the responsible chemicals emitted from industries.

  • PDF

에어컨디셔너 공기질 개선의 신뢰도 확보를 위한 냄새 분석 기술 연구 (Research on Odor Analysis Technology to Secure the Reliability of Air Quality Improvement in Air Conditioners)

  • 강석현;허필호;안영철
    • 한국환경과학회지
    • /
    • 제30권1호
    • /
    • pp.45-55
    • /
    • 2021
  • In this study, the odor of the parts and the odor of the surrounding environment were classified and verified. In order to increase the reliability of odor quantitative/qualitative analysis, the selection criteria for 5 sensory evaluators were established, and the n-Butanol control solution for each odor intensity was periodically trained to recognize the odor intensity before sensory evaluation. In addition, although various odor thresholds have been used through several studies, verification of whether the odor intensity value obtained through GC/MSD analysis is similar to the degree to which a person directly smells and feels it. It is important to select the odor threshold that has the best correlation with the odor intensity calculated by the person smelling the odor. Finally, sampling and measuring flowing airflow and temporary odors such as odor component analysis was experimentally difficult due to limited collection space and differences in concentration of generated components. In this study, a quantitative analysis was made possible by using the low temperature concentration (cooling) trap method. Through this, it was confirmed that the correlation with the actual odor intensity was not caused by the product itself, but by the environmental factor discharged from the product after creating the odor environment.

다중회귀분석을 이용한 악취 관리지역에서의 복합취기강도와 개별악취물질들의 관계에 대한 연구 (The Relationship Between Odor Unit and Odorous Compounds in Control Areas Using Multiple Regression Analysis)

  • 김종보;정상진
    • 한국환경보건학회지
    • /
    • 제35권3호
    • /
    • pp.191-200
    • /
    • 2009
  • We investigated a trait of odor and the relationship between odor unit and odorous compounds using multiple regression analysis based on data compiled from Sihwa (SIC), Banwol (BIC), Banwol plating (BPIC) and Poseung industrial complex (PIC). These areas are odor control areas in Gyeonggi province. It was revealed that $NH_3$ and styrene concentrations in SIC and BPIC were relatively higher and $H_2S$ concentration especially in mc was more than five times higher than other areas. As a result of regression analysis using SAS, intensity of odor unit was highly related to concentrations of $H_2S$, TMA, styrene and n-valeraldehyde in SIC, $H_2S$, acetaldehyde, and butyraldehyde in BPIC and $NH_3$ in BIC.

후각 센서를 이용한 냄새 인식 및 실감형 멀티미디어 표현 기술 (A technology of realistic multi-media display and odor recognition using olfactory sensors)

  • 이현구;노용완
    • 디지털산업정보학회논문지
    • /
    • 제6권4호
    • /
    • pp.33-43
    • /
    • 2010
  • In this paper, we propose a floral scent recognition using odor sensors and a odor display using odor distribution system. Proposed odor recognition has method of correlation coefficient between sensors that select optimal sensors in floral scent recognition system of selective multi-sensors. Proposed floral scent recognition system consists of four module such as floral scent acquisition module, optimal sensor decision module, entropy-based floral scent detection module, and floral scent recognition module. Odor distribution system consists of generation module of distribution information, control module of distribution, output module of distribution. We applied to floral scent recognition for performance evaluation of proposed sensors decision method. As a result, application of proposed method with floral scent recognition obtained recognition rate of 95.67% case of using 16 sensors while applied floral scent recognition system of proposed sensor decision method confirmed recognition rate of 96% using only 8 sensors. Also, we applied to odor display of proposed method and obtained 3.18 thorough MOS experimentation.

응축수를 이용한 냉각기의 냄새원인물질 평가방법 검토 (Examination about evaluation method of odor active compounds in evaporator by using condensed water)

  • 김선화;김경환;정영림;김만구;김재호;박하영;지용준
    • 분석과학
    • /
    • 제20권5호
    • /
    • pp.361-369
    • /
    • 2007
  • 냉각기에서 방출되는 불쾌한 냄새는 실내 공기질을 저하시키는 주요 원인이다. 냄새문제를 해결하기 위해서는 냄새원인을 규명하여야 한다. 냉각기에서 냄새가 발생될 때 공기시료는 냄새강도는 약하고 순간적이어서 채취하여 분석하는데 많은 어려움이 따른다. 이 연구에서 응축수를 이용하여 냉각기의 냄새원인물질의 평가 가능성을 확인하였다. 응축수는 headspace-solidphase microextraction(HS-SPME) 방법을 이용하여 채취하였다. GC/FID/Olfactometry(GC/FID/O)로 냄새물질을 확인한 후, GC/AED, GC/MS로 정성하였다. 직접관능평가 결과 및 GC/FID/O의 개별냄새물질 분석 결과, 공기시료와 매우 유사하게 나타났다. 냄새원인물질은 주로 산소를 포함하는 alcohols와 acids로 확인되었다. 응축수를 이용한 냄새원인물질 평가 방법은 채취 용이성, 비용, 분석적인 측면에서 효과적인 방법으로 평가 되었다.

생활폐기물 자동집하시설의 악취물질 배출특성 (Emission Characteristics of Odor Compounds from Pneumatic Waste Collection Plants)

  • 윤용경;김대근
    • 대한환경공학회지
    • /
    • 제34권8호
    • /
    • pp.541-548
    • /
    • 2012
  • 본 연구에서는 생활폐기물 자동집하시설에서의 악취물질 배출특성을 파악하고자 2개소(A시설, B시설)의 시설을 선정하여 공기관로 내의 이송가스와 최종배출가스를 대상으로 복합악취와 22종의 지정악취물질을 조사하였다. 생활폐기물 자동집하시설에서 배출되는 주된 악취물질은 암모니아, 황 화합물, 아세트알데하이드이었으며, 악취처리공정의 종류에 따라 최종배출구의 악취 배출특성이 상이하였다. 이송가스를 대상으로 한 악취기여도 평가에서는 A시설의 경우, 디메틸설파이드 26%, 아세트알데하이드 18%, 메틸머캅탄 14%의 악취기여도를 보였으며, B시설의 경우에는 메틸머캅탄 56%, 황화수소와 디메틸설파이드가 각각 15%이었다.