The Relationship between Habitual Patient-Reported Symptoms and Signs in the Soft Contact Lens Wearers (소프트 콘택트렌즈 착용자에서 평상시 나타난 증상에 관한 연구)

  • Lee, Koon-Ja;Buyn, Jang-Won;Mun, Mi-Young;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.19-28
    • /
    • 2008
  • Purpose: To understand symptoms and signs in soft contact lens wearers the authors evaluate the attribution of the tear test to the contact lens related symptoms and signs. Methods: Sixty-two healthy soft contact lens wearers (23.95${\pm}$4.38 years old, 18.60${\pm}$16.92 months of prior lens wear) were participated in this study. 3 kinds of tear test and McMonnies' questionnaire test were performed for the soft contact lens wearers and subjective symptoms and objective signs were graded using CCLRU scales during the study period. Results: In this surveys, we found ocular dryness, redness and tiredness are the most common frequent and severe symptoms in soft contact lens wearers. Frequency of the ocular dryness, redness and tiredness are associated with grittiness, burning sensation and foreign body sensation respectively, and severity of the photophobia, foreign body sensation are associated with unstable vision and grittiness and which are associated with score of McMonnies' Questionnaire. Conjunctival redness and limbal redness are major signs but those are not need to be clinical care and rarely occurred corneal and conjunctival staining which are associated with tear break-up-time statistically. Conclusions: Dryness, redness and tiredness are primary common symptoms in Korean soft contact lens wearers. The frequency of those symptoms are increased with the period of soft contact lens wear and those are associated with other symptoms but have no relationship with signs.

  • PDF

A Comparative Study on the Local Transmittance Homogeneity of the Ocular Lens (안경 렌즈의 국소적 투과율 균일도 비교 연구)

  • Park, Sang-Kook;Ri, Hyeong-Cheol;Jang, Yun-Seog;Sung, Duk-Yong;Kang, Sung-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.471-476
    • /
    • 2015
  • Purpose: We have analyzed the transmittance distribution of various ocular lenses using local transmittance microscope to investigate the optical homogeneity of the lens. Methods: The local transmittance of the laser which is focused on the surface of the spectacle lens was measured by using the photo-detector, lock-in amplifier and motorized-stage. 25 multi-coated lenses with non-tinted of 5 groups and 45 multicoated lenses with tinted of 9 groups were analyzed as a sample respectively. Results: Average and deviation of local transmittance for nontinted lenses were measured almost uniformly with various refractive index and coating. However, deviation of transmittance of for tinted lenses was analyzed as about 3.7 times larger than that of non-tinted lenses. Inhomogeneity of local transmittance of for tinted lenses was also analyzed as about 3.1 times larger than that of non-tinted lenses. Conclusions: We could analyze that standard deviation of transmittance and inhomogeneity of local transmittance of for tinted lenses is larger than that of non-tinted lenses using the local transmittance microscope. These analysis using local transmittance microscope can be utilized as a way to evaluate lens performance and improve optical homogeneity.

Improved 3D Resolution Analysis of N-Ocular Imaging Systems with the Defocusing Effect of an Imaging Lens

  • Lee, Min-Chul;Inoue, Kotaro;Cho, Myungjin
    • Journal of information and communication convergence engineering
    • /
    • v.13 no.4
    • /
    • pp.270-274
    • /
    • 2015
  • In this paper, we propose an improved framework to analyze an N-ocular imaging system under fixed constrained resources such as the number of image sensors, the pixel size of image sensors, the distance between adjacent image sensors, the focal length of image sensors, and field of view of image sensors. This proposed framework takes into consideration, for the first time, the defocusing effect of the imaging lenses according to the object distance. Based on the proposed framework, the N-ocular imaging system such as integral imaging is analyzed in terms of depth resolution using two-point-source resolution analysis. By taking into consideration the defocusing effect of the imaging lenses using ray projection model, it is shown that an improved depth resolution can be obtained near the central depth plane as the number of cameras increases. To validate the proposed framework, Monte Carlo simulations are carried out and the results are analyzed.

The Change of the Near Eye Position according to the Spectacle and Contact Lens Wearing (안경과 콘택트렌즈 착용에 따른 근거리안위의 변화)

  • Han, Sun-Hee;Kim, Bong-Hwan;Kim, Hak-Jun;Park, Jun-Sung;Park, Hae-Been;Kim, Mi-Jeong;Park, Ju-Hyeong;Kim, Jin-Sol;Lee, Kyeong-Hoon;Kim, Jong-Hwan;Ha, Na-Ri
    • Journal of Korean Clinical Health Science
    • /
    • v.3 no.4
    • /
    • pp.435-443
    • /
    • 2015
  • Purpose. This study was to investigate comparison of the near eye position according to the spectacle and contact lens wearing. Methods. We measured the AC/A ratio and near horizontal phoria using modified Thorington method in each case spectacle and contact lens wearing of equivalent spherical power after measuring the full corrected diopter for 20 subjects (men 5, woman 15, $21.15{\pm}1.35$ years) without specific ocular diseases, ocular surgery experience and vision anomalies. Results. It was shown high correlation between spectacle and contact lens wearing as AC/A ratio is a correlation coefficient 0.99 (p=0.00), near horizontal phoria is a correlation coefficient 0.95 (p=0.00). And contact lens wearing increased as AC/A ratio by $0.32{\pm}1.35$ ${\Delta}/D$ (p=0.31) and near horizontal phoria by $-0.17{\pm}2.18$ ${\Delta}$ (p=0.73) than spectacle wearing but there was no statistically significant difference. As the higher myopic grade AC/A ratio increased and then was shown decreased tendency in -6.00 D < $SED{\leq}-4.00$ D group (p>0.05) and as the higher myopic grade near exophoria increased but there was no statistically significant difference (p>0.05). Conclusions. We should consider that the subjects who had the lower AC/A ratio or higher near exophoria in -6.00 D < $SED{\leq}-4.00$ D group were necessary to measure AC/A ratio and near horizontal phoria when they were wearing contact lens because contact lens wearing tended to increase the near exophoria than spectacle wearing.

The Correlation of Myopic Refractive Error and Ocular Components in Primary School Students (초등학생의 근시성 굴절이상과 안광학 성분들의 관련성)

  • Jeon, Soon-Woo;Lee, Hyun-Joo;Hwang, Hye-Kyung;Park, Chun-Man
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.299-303
    • /
    • 2012
  • Purpose: In this study the correlation among the myopic refractive error and ocular components in primary school students was investigated. Methods: The subjects were 62 children who had no eye diseases. The refractive error, corneal radius, anterior chamber depth, lens thickness, axial length were measured and analysed. Results: Myopic refractive error in primary school students was negatively correlated with the axial length (1~3rd grade r=-0.653, p=0.000/4~6th grade r=-0.742, p=0.000), AL/CR ratio (1~3rd grade r=-0.571, p=0.000/4~6th grade r=-0.852, p=0.000). Conclusions: It was shown that the axial length and axial length(AL)/corneal radius(CR) ratio were very important data for myopic refractive error in primary school students.

Optical system design for stereoscopic video-recorder (비디오 입체영상녹화를 위한 광학계 설계)

  • Hong, Kyung-Hee
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.506-509
    • /
    • 2002
  • An optical system for a stereoscopic video recorder is designed with the field of view 42$^{\circ}$ and effective diameter 22 mm. We can use it by attaching it to the front lens of any video camera or camcorder to record a stereoscopic scene. This system is a double Kepler type afocal system to make the image erect and a bi-ocular type to record and display the stereoscopic scene. The optical tube length is folded with several flat mirrors and a beam splitter to be compact. This optical system is composed of 4 groups of lenses and each group serves as a relay lens for minimizing the vignetting effect. Whole field stereoscopic scenes may be captured by perpendicularly polarized alternated recording with a chopper and two perpendicular polarizers, without any loss of light energy. The displayed images may be seen stereoscopically with polarized spectacles and are kinetic because of an afterimage effect.

The Effects of Spherical and Aspherical RGP Contact Lenses on Visual Performance (구면 및 비구면 RGP 콘텍트렌즈가 시력의 질에 미치는 영향)

  • Kim, Soo-Hyun;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.31-38
    • /
    • 2009
  • Purpose: This study was to evaluate corneal topography, contrast sensitivity and ocular response of a RGP, back surface aspherical contact lens compared with a spherical contact lens. Methods: A total 37 subjects were fitted with a spherical lens in right eye and an aspherical in the left eye and were evaluated for changes in corneal topography and contrast sensitivity over a 2-month period. Results: Thirty-four of 37 subjects completed the 2-month study. The corneal topography did not show differences between spherical and aspherical RGP lenses. The eyes fitted with the aspherical lenses demonstrated a greater reduction in contrast sensitivity compared with their spherical counterparts under photopic condition. Subjects preferred comfort and ocular responses provided by the spherical lens. Conclusions: Corneal topography when comparing spherical and back surface aspherical RGP lenses did not show any significant difference in the subjects. Spherical RGP lens yields better contrast sensitivity and preference than aspherical RGP lens at photopic condition. Further investigation of aberrations induced by contact lens design is warranted to explain the observed differences in visual performance.

  • PDF

Septic Implantation Syndrome Following Anterior Lens Capsule Disruption by Cat Claw in Three Dogs (개에서 고양이 발톱에 의한 수정체 전낭 파열 후 감염체 착상 증후군의 발생 3 증례)

  • Kang, Seonmi;Lee, Euiri;Park, Sangwan;Park, Sungwon;Noh, Hyunwoo;Seo, Kangmoon
    • Journal of Veterinary Clinics
    • /
    • v.31 no.4
    • /
    • pp.344-349
    • /
    • 2014
  • A 5-year-old intact female Maltese, a 4-year-old neutered male Chihuahua, and a 5-year-old neutered male Maltese were referred to Veterinary Medical Teaching Hospital of Seoul National University for assessment of traumatic corneal laceration accompanied by anterior lens capsule disruption by cat claw. Severe uveitis, hypopyon, fibrinous exudate, diffuse corneal edema, and/or glaucoma were observed. B-mode ocular ultrasound showed lens capsule rupture and hyperechoic lens in all three cases. Despite aggressive treatments, the three eyes continued to deteriorate with endophthalmitis, leading to enucleation. Septic implantation syndrome associated with phakitis, severe pyogranulomatous endophthalmitis, and keratitis was confirmed by histopathological examination.

The status of care for Soft Contact Lens and periodic examination (연성 콘택트렌즈의 관리 및 정기검사 실태)

  • Shin, Jang Cheol
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.107-113
    • /
    • 2000
  • This study has analyzed soft contact lens care-after-sale and periodic examinations at optical shops and eye clinics. And I wish to make that use of educational data for the soft contact lens lesson of the department of ocular optics. This questionnaire studied the status of care for soft contact lens and periodic examination, of students who wears soft contact lens. The results are as follows: First, 7.5% of students questioned wore soft contact lens. More women than men wore soft contact lens. The soft contact lens wearers purchased lens mainly at optical shops. 78.5% of them wore daily wear lens. Because of cosmetic advantages of soft contact lens. 47.9% of them wore soft contact lens. 72.5% of them wore soft contact lens less than 12 hours per a day. 32.0% of them has worn soft contact lens more than 6 months less than 1 year. 51.1% of them experienced irritation. 39.7% of them have exchanged soft contact lens between 6 and 9 months. Secondly, when purchasing lenses. 60% of soft contact lens wearers were given instructions of general care, such as duration of wearing lens, how to remove protein, how to store, and how to sterilize at both of eye clinics and optical shops. But the proportion of instructions, such as side effects and periodic examination which were given to soft contact lens wearers, is lower both at eye clinics and optical shops. Especially at optical shops, the proportion of instruction for periodic examination, is lower than at eye clinics(p<0.05). Thirdly, The proportion of operations of periodic examinations after use of soft contact lens both at eye clinics and optical shops, is low. The soft contact lens wearers have had more periodic examinations at eye clinics than at optical shops. But the rate of non-periodic examination at optical shop is 87.9%. And for periodic examinations, general care was done at optical shops. On the other hand, eye examinations, general care, and treatments were done more at eye clinics. Fourthly, 60.3% of the soft contact lens wearers understood the necessity of the periodic examinations, but actually, only 6.4% of them were given the schedule for the periodic examinations, and 2.5% of them were given at an optical shop(p<0.01).

  • PDF

Eye Irritation Test of Lens Washing Agents as ReNuTM (렌즈 보존액 ReNuTM에 대한 안점막자극시험)

  • Jang, Woo-Yeong;Lee, Jeong-Yeong;Joo, Kyung-Bok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.293-304
    • /
    • 2005
  • As the eye irritant test of lens washing agent, ReNu$^{TM}$ was analysed using Draize methods (1959) according to KFDA Guidelines. In addition, to test the potential toxicity of test articles the ratio of inflammatory cells and non-inflammatory epitheloid cells were also observed using smear cytology methods against ocular discharge. At test, the histopathological changes on the cornea, iris, retina and sclera were also observed in all animals. Slight irritancy of the cornea and conjunctiva were observed at 1, 2 and 3 days after dropping in non-washing group. The Mean Index of Ocular Irritation(MIOI) of these points are detected as 4.17, 3.00 and 1.33, respectively. In washing group, slight irritancy of the cornea and conjunctiva were observed at 1 and 2 days after dropping with MIOI as 0.67 and 1.33, respectively. Therefore, ReNu$^{TM}$ was considered as non-irritating materials because the MIOI is detected below 5.00 throughout the whole experimental periods in both washing and non-washing groups. The Index of Acute Ocular Irritation(IAOI) is also detected as 4.17(1 day after dropping). Except of the somewhat increase trend of the inflammatory cell ratios in ocular discharge at 1 day after dropping of non-washing group, but significances are not detected, on the other hand, no meaningful changes on smear cytology of ocular discharges are observed in this study. In addition, no abnormal histopathological changes on the cornea, iris, retina and sclera were also not detected in ReNu$^{TM}$ dropping group compared to that of non-treated control eyes.

  • PDF