• Title/Summary/Keyword: Occupational Values

Search Result 438, Processing Time 0.032 seconds

Exposure Assessment of Korean Farmers While Applying Chlorpyrifos, and Chlorothalonil on Pear and Red Pepper (노지고추 및 배 재배 농업인의 방제작업 중 Chlorpyrifos, Chlorothalonil 노출에 관한 연구)

  • Kang, Tae-Sun;Kim, Gil-Joong;Choe, In-Ja;Kwon, Young-Jun;Kim, Kyung-Ran;Lee, Kyung-Sook
    • Journal of agricultural medicine and community health
    • /
    • v.29 no.2
    • /
    • pp.249-263
    • /
    • 2004
  • Objectives: The objectives of the present study were to establish the exposure monitoring method of chlorpyrifos and chlorothalonil application to pear and field red pepper by vehicle-mounted sprayer, hand-held sprayer and to assess the risk. Methods and Results: Chlorpyrifos met all of requirements of sampling and analysis method(U.S. EPA), but chlorothalonil met only dermal patch method. Potential dermal and inhalation exposure was evaluated in 42 farmers. Compared with the hand-held sprayer application, vehicle mounted sprayer demonstrated producing relatively lower dermal exposure levels with statistical significance. In dermal exposure during hand-held application, there is no significant difference between pear and red pepper. Conclusions: This results show that application method is the main factor of dermal exposure. There was no statistically significant difference between each group of respiratory exposure level. The margin of safety (MOS) was calculated to assess the risk of pesticide exposure. All Chlorpyrifos MOS values are lower than 0.2, which mean working conditions are unsafe. In order to protect farmers, big efforts to control exposure are needed.

  • PDF

Pulmonary Function and Influence Factors among Residents around Gwangyang Steel Mill (광양 제철소 주변지역 거주자들의 폐기능과 영향 요인)

  • Hong, Eun-Ju;Ahn, Gi-Sub;Chung, Eun-Kyung;Choi, Jae-Ho;Guo, Xinbiao;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.3
    • /
    • pp.182-192
    • /
    • 2011
  • Objectives: This study aims to identify the influential factors on the pulmonary function of targeted general residents in the areas surrounding Gwangyang Steel Mill. Methods: An PFT (Pulmonary Function Test) was conducted from May 2007 to November 2007 on 974 target residents (438 male, 536 female), including an exposed group (674 people) who resided within a radius of 5 km from Gwangyang Steel Mill in Gwangyang-si, Jeollanam-do and a control group (300 people) who resided outside a radius of 15 km. A survey related to personal characteristics, life habits, respiratory diseases and allergic symptoms, medical histories and living environments of the residents was also conducted to identify influential factors on pulmonary function. Results: As %$FEV_1$ and %FVC of the exposed group are 99.17% and 96.98%, respectively, and those of the control group are 105.47% and 101.91%, respectively, with the PFT values of the exposed group being lower than those of the control group (p<0.001), it turns out that the pollution in the industrial complex is likely to trigger a reduction in the pulmonary function of local residents. The odds ratio analysis result for asthma diagnosis history indicates that the odds ratios tend to be higher among surveyed residents who are living near above-average traffic volumes and are using beds, where it is statistically meaningful that especially the odds ratios are higher if the residences are closer to roads (p<0.01, CI=1.12-4.52). The factors that affect the FEV1 are identified as smoking, passive smoking, asthma diagnosis history, nasal congestion symptoms and allergic eye disease ($R^2$=0.154, p<0.001). The factors that affect the FVC are identified as smoking, passive smoking, asthma diagnosis history and allergic coryza ($R^2$=0.158, p<0.001). In addition, the analysis result for the relevance of air pollution levels to pulmonary function ($FEV_1$, FVC) shows that FEV1 and FVC tend to decrease as the concentration of $O_3$ increases. Conclusions: We believe that this study may provide preliminary data for the development of preventive measures for health effects on the residents and environmental health control measures for environmental pollution in the industrial complex area.

Characteristics of Right Hemispheric Damaged Patients in Korean Focused Prosodic Sentences (한국어 초점 발화 시 우반구 손상인의 초점 운율 특성)

  • Lee, Myung Soon;Park, Hyun
    • Therapeutic Science for Rehabilitation
    • /
    • v.8 no.3
    • /
    • pp.69-81
    • /
    • 2019
  • Objective: The purpose of this study was to examine the characteristics of prosody of ambiguous sentences in patients with right hemisphere damage(RHD). Methods: Sentences with each word prosodically focused were used to investigate. Several acoustic parameters such as intensity, F0, and duration were measured to identify characteristics of prosody in patients with lesions in the right hemisphere and normal controls. All speech samples were recorded using the Praat 4.3.14 software. Data were analyzed with the independent sample t-test using SPSS 18.0. Results: The results of this study are as follows: First, intensity of the first syllable of the focus word was different between the two groups in several sentences. Second, F0 was different between the two groups in all sentences. Third, duration was different between the groups in several sentences. Accordingly, prosody were varied and values of acoustic parameters differed due to the focus of utterance. The group with right hemisphere damage showed restricted prosody. Conclusions: Intensity, duration, and F0 are all used as elements of prosody in emphasizing structural and pragmatic meaning, but according to the focus, strength and duration were related to F0. In contrast, F0 has a significant linguistic difference, but there was a significant difference between the RHD and normal people, so F0 can be a discriminatory factor of rhyme evaluation of the right hemisphere damaged and it is necessary to accumulate more strong evidence through future research.

Explosion Characteristics Analysis of Low-Density Polyethylene Dust (저밀도 폴리에틸렌 분진의 폭발특성 분석)

  • Hyun-gil Kwon;Kyeong-seok Oh;Jong-bae Baek;Dong-hyun Seo
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.80-88
    • /
    • 2023
  • Ensuring safety in the designing of manufacturing and handling facilities for low-density polyethylene (LDPE) is difficult because there are no standards for the dust explosion characteristics of LDPE. In this study, a dust explosion test was performed on two dust samples collected from a bag filter (LDPE 1) during the LDPE manufacturing process and sedimentary dust (LDPE 2) leaked outside a facility such as a silo, and the LDPE 2 explosion test results were summarized. Particle size analysis showed that the volume-based particle diameter (median) was 95.04 ㎛ and the number density was 0-1 ㎛. The maximum explosion pressure (Pmax) was 6.6 bar, and the maximum rate of explosion pressure rise was 366 [bar/s] at 1500 g/m3. Accordingly, the dust explosion index (Kst) was 99.4 bar·m/s, which was confirmed as ST-1 grade. Moreover, the minimum ignition energy and minimum ignition temperature was 10 mJ and 450 ℃, respectively. Currently, manufacturing and handling design is based on the characteristic values of high-density polyethylene (HDPE). However, as the test results show that LDPE 2 dust has a higher risk than HDPE (particle diameter 61.6 ㎛), caution is required when using the HDPE design criteria in the LDPE manufacturing process.

Arm Span-Height Relationship for Prediction of Spirometric Values in Korean Adult Women (우리나라 성인여성에서 정상 폐활량 예측을 위한 양팔벌린 손끝길이와 신장과의 관계)

  • Koh, Won-Jung;Ju, Young-Su;Kim, Tae-Yub;Park, Jae-Sung;Yu, Seung-Do;Choi, Kwaung-Soo;Paek, Do-Myung;Han, Sung-Koo;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.786-794
    • /
    • 1999
  • Back ground : Arm span measurements provide a practical substitute for standing height to predict normal spirometric values in subjects unable to stand or those with a skeletal deformity such as kyphoscoliosis. The relationship between arm span and height has previously been reported as either a fixed ratio unaffected by age or as a regression equation in which the ratio varies as a function of age. The fixed ratio or regression equation is known to be specific for sex and race. Methods : We studied the relationship between standing height, arm span, and age in 381 Korean adult female subjects (ages 20 to 69 yrs) sampled in a general population. Results : The mean ratio for arm span to height is 1.004. Multiple linear analysis found arm span and age to be predictive of standing height (p=0.0001, $r^2$=0.76). We performed the analysis of the difference between the predicted height using either fixed ratio or regression equation and actual height. At the extremes of arm span and age, the ratio method either underestimated(at smaller arm span or younger age) or overestimated(at larger arm span or older age) as compared with actual height (p=0.0001). Conclusion : This results indicate that the estimated height using the fixed ratio method provides a less acceptable method of estimating height for the prediction of lung volumes in the Korean adult women when compared with the regression equations, especially at the extremes of stature or age.

  • PDF

Comparison of crown designs of different dental occupational groups, using CAD-CAM (CAD-CAM을 이용하여 디자인한 금관의 치과 직업군에 따른 형태 비교)

  • Kim, TaeHyeon;Kim, Jong-Eun;Lee, Ah-Reum;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.234-238
    • /
    • 2016
  • Purpose: Increasing use of computer aided design-computer aided manufacturing (CAD-CAM) system and number of design software made design of restoration easy and quick. Outcome of restoration has been dependent on dental technician's wax up proficiency, dentists can design restoration for themselves now. This study aims to investigate the outcome of restoration designs, according to handling skill of CAD-CAM design tool. Materials and methods: A patient's mandibular right 1st molar was prepared. After taking impression, stone model was made, scanned the stone model with 3 shape intra-oral scanner, stereolithography (STL) file was extracted. With 3shape dental designer, one dental technician with more than 5 years work experience (designer 0) and three dental technicians with less than 2years work experience (designer 1, 2, 3-group DT) and 4 1st year residents (designer 4, 5, 6, 7-group RT) designed gold crown on the same STL file. Designed crown's MD (mesio-distal) and BL (bucco-lingual) diameter, height of crown, inter-cuspal distance, number of occlusal contact points were compared. Statistical analysis was carried out, test of normality within each group, using independent t-test. Number of contact points were compared, using Wilcoxon signed-rank test. Results: There was no significant difference between group DT and group RT. Number of contact points also resulted in no significant difference. Conclusion: The outcome of each designed crowns showed no statistical differences, in values which can be expressed as numbers. Subjective factors were different. With increasing proficiency in handling designing software, fabrication of restorations according to each designer's occlusal concept can be made easy.

The study of bone density assessment on dental implant sites (임플란트 식립 부위의 골밀도 평가에 관한 연구)

  • Park, Su-Won;Jang, Soo-Mi;Choi, Byoung-Hwan;Son, Han-Na;Park, Bong-Chan;Kim, Chang-Hwan;Son, Jang-Ho;Sung, Iel-Yong;Lee, Ji-Ho; Cho, Yeong-Cheol
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.5
    • /
    • pp.417-422
    • /
    • 2010
  • Introduction: Bone density is one of the important factors for the long term success of endosseous implants. The bone density varies from site to site and from patient to patient. A preoperative evaluation of the bone density is quite useful to oral surgeons for planning dental implantation. More accurate information on the bone density will help surgeons identify suitable implant sites, thereby increase the success rate of dental implantation. This study examined the correlation between the bone density measured preoperatively by computed tomography (CT) and the implant primary stability measured by resonance frequency analysis. Furthermore, the effects of the implant sites, gender, age and generalized systemic disorder patients on the bone density and primary implant stability were examined. Materials and Methods: One hundred and fourteen patients were selected. None of the patients had undergone a tooth extraction or bone graft history in the previous year. Preoperatively, the patients underwent CT scanning to evaluate the Hounsfield unit (HU), and resonance frequency analysis (RFA) was used to evaluate the implant primary stability at the time of implant installation. All implants were 4.0 mm diameter and 11.5 mm length US II. All patients were recorded and the HU and implant stability quotient (ISQ) value were evaluated according to the sites, gender and age. Results: The highest HU values were found in the mandibular anterior site ($827.6{\pm}151.4$), followed by the mandibular molar site ($797{\pm}135.1$), mandibular premolar site ($753.8{\pm}171.2$), maxillary anterior site ($726.3{\pm}154.4$), maxillary premolar site ($656.7{\pm}173.8$) and maxillary molar site ($621.5{\pm}164.9$). The ISQ value was the highest in the mandibular premolar site ($81.5{\pm}2.4$) followed by the mandibular molar site ($80.0{\pm}5.7$), maxillary anterior site ($77.4{\pm}4.1$), mandibular anterior site ($76.4{\pm}11.9$), maxillary premolar site ($74.2{\pm}14.3$) and maxillary molar site ($73.7{\pm}7.4$). The mean HU and ISQ value were similar in females and males. (HU: P=0.331, ISQ: P=0.595) No significant difference was also found in the age group respectively. However, the correlation coefficients between the variables showed a closed correlation between the HU and ISQ value. Conclusion: These results showed close correlation between the bone density (HU) and primary stability value (ISQ) at the time of implant installation (Correlation coefficients=0.497, P<0.01). These results strengthen the hypothesis that it might be possible to predict and quantify the initial implant stability and bone density from a presurgical CT diagnosis.

Application of HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version) to screening test of noise-induced hearing loss (소음성 난청 선별검사에 HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version)의 적용)

  • Lee, Mi-Young;Suh, Suk-Kwon;Lee, Choong-Won
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.539-553
    • /
    • 1996
  • The study was conducted from May to September in 1994 to investigate applicability of the Hearing Handicap Inventory for the Elderly-Screening version(HHIE-S) in parallel with the pure-tone audiometer to the initial screening test of noise-induced hearing loss(NIHL) in some noise-exposed workers. Subjects were selected by systemic sampling that took every 10th person from 6, 700 workers taking the annual occupational health examination by the department of Health Maintenance of Dongsan Hospital Keimyung University in Taegu. The authors administered the pure-tone audiometric test and self-reported questionnaire of HHIE-S including items of sociodemographic and job-related variables concurrently. The final subjects analysed were 1,019(488 males and 531 females) excluding fourteen persons who had many missing values in their questionnaires. The reliability coefficients of HHIE-S scale by Cronbach's alpha were 0.84. In the univariate analysis of hearing handicap measured by the HHIE-S, work duration, military service and the hearing threshold loss at 1KHz and 4KHz by the initial audiometer were significant in males while age, work duration and hearing threshold loss at 1KHz and 4KHz were significant in females. In the stepwise linear regression analysis, hearing threshold loss at 1KHz and 4KHz, was the only selected variable explaining the hearing handicap in males and hearing threshold loss at 1KHz and 4KHz, age, and work duration were selected in females. In ROC curves for HHIE-S scores against NIHL as gold standard which was defined by the follow-up audiogram as more than 30dB of the average of 0.5/1/2KHz and 50dB at 4KHz, the optimal cutoff for the parallel HHIE-S appeared to be 8. The results suggest that HHIE-S appeared to have some reliability and validity in this data and might be used in screening NIHL in parallel with pure-tone audiometer in noise-exposed workers.

  • PDF

Relationship between Environmental Exposure and Biological Monitoring Values in Workers Exposed to Styrene (스타이렌 폭로 근로자의 환경중 폭로농도와 생물학적 모니터링에 관한 연구)

  • Paik, Jong-Min;Lee, Jong-Yung;Kim, Jung-Man
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.161-170
    • /
    • 1997
  • This is an effort to confirm changes biological monitoring according to changes in levels of exposure to styrene for industrial workers. This study was conducted on 108 workers, including male of 64 and female 44 who were working at factories of FRP, dipping, and coating. An improved passive monitor method(organic vapor monitor; OVM) was employed to determine levels of exposure. The biological monitoring include blood styrene concentration, urinary mandelic acid(MA), and urinary phenylglyoxylic acid(PGA). Biological monitoring were made through the Collection of blood and urine. The mean value of exposure to styrene was 21.0ppm, which is measured by organic vapor monitor, one of improved passive monitors. The highest exposure level was observed among workers in boat factories, laminating procedure workers, processing workers, respectively(p<0.01). For exposure level, 11% of subjects under study showed over 50ppm which is time weighted average(TWA). The correlation coefficient between biological specimens and the exposure level was 0.62 for blood styrene concentration, 0.58 for MA corrected by creatinine, and 0.70 for PGA corrected by creatinine, respectively(p<0.01). The regression analyses found exposure level relative importance in explaining variance in biological monitoring. In additional to that, gender was a significant factor in explaining variance of MA and MA+PGA. Almost half of variance(49%) in blood styrene concentration was explained by predictors, including exposure level, age, gender, duration, and drinking volume during the last week(p<0.01). The very high correlation(higher than 0.95 was found when a comparison was made among three types of corrected methods, including uncorrected specific gravity and creatinine. In conclusion, these findings suggest OVM to represent levels of exposure to styrene for industrial workers. A discussion was made on possible use of specific gravity sample for biological monitoring. Exposure level may be predicted on MA, PGA in urine, which could be applied to represent biological monitoring.

  • PDF

Characteristics of Metallic Elements Concentration of Fine Particles(PM10, PM2.5) at Busan in 2004 (2004년 부산지역 미세먼지(PM10, PM2.5) 중의 금속 농도 특성)

  • Jeon Byung-Il;Hwang Yong-Sik;Lee Hyeok-Woo;Yang Ah-Reum;Kim Hyun-Jung;Seol Jae-Hwan;Kang Young-Jin;Kim Taek-Hoon;Jang Hyun-Seok
    • Journal of the Korean earth science society
    • /
    • v.26 no.6
    • /
    • pp.573-583
    • /
    • 2005
  • [ $PM_{10}\;and\;PM_{2.5}$ ] aerosols were collected at Busan from March, 2004 to December, 2004, and the concentrations of some metal elements were chemically analyzed to study their characteristics. The mean concentration of $PM_{10}$ was $58.2{\mu}g/m^3$ with a range of 8.3 to $161.1{\mu}g/m^3$. The mean concentration of $PM_{2.5}$ was $29.3{\mu}g/m^3$ with a range of 2.8 to $65.3\mu}g/m^3$. The mean mass concentrations of Asian dust and non Asian dust in $PM_{10}$ were $121.5\mu}g/m^3$ and $56.0{\mu}g/,^3$ respectively. The mean values of crustal enrichment factors for six elements (Cd, Cr, Cu, Ni, Pb and Zn) were all higher than 10, possibly suggesting the influence of anthropogenic sources. The crustal enrichment factors of some heavy metal elements in non-Asian dust (NAD) were higher than those in Asian dust (AD), possibly due to anthropogenic emissions transported from industries around this area by westerly wind. The soil contribution ratios for $PM_{10}$ and $PM_{2.5}$ were $15.2\%$ and $17.5\%$ on the whole. and those of AD/NAD for $PM_{10}$ and $PM_{2.5}$ were 1.9 and 2.1, respectively.