• Title/Summary/Keyword: Occupational Values

Search Result 438, Processing Time 0.028 seconds

Effects of Factors Associated with Urine Hippuric Acid Correction Values in Urinary Creatinine by HPLC and Jaffe Method and Specific Gravity HPLC Jaffe Method (HPLC와 Jaffe method의 요중 크레아티닌 및 비중이 마뇨산 보정값에 미치는 요인에 관한 연구)

  • Kim, Key-Young;Kim, Jong-Gyu;Yoon, Ki-Nam;Park, Wha-Me;Park, Hun-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.4
    • /
    • pp.493-505
    • /
    • 2015
  • Objectives: The purpose of this study was to evaluate the relevance of adjusting a urinary sample for urine hippuric correction value and its effects. Urinary biological monitoring data are typically adjusted to a constant creatinine and specific gravity concentration to correct for variable dilutions among spot samples. This study was conducted to evaluate the suitability of adjusting the urinary concentrations of urine creatinine and specific gravity(SG). Methods: We measured the concentrations of hippuric acid, in spot urine samples collected from control(119), case(120) individuals. The value of hippuric acid was adjusted by SG and urinary creatinine(HPLC & Jaffe). Results: The major results were as follows. The concentrations of urinary creatinine and SG for the control group were 1.84 g/L(SD 0.99) for arithmetic mean and 1.56 g/L(GSD 1.86) for geometric mean by HPLC method, 1.57 g/L (SD, 0.82) for arithmetic mean and 1.33 g/L(GSD 1.85) for geometric mean by Jaffe method, 1.028(SD 0.09) for arithmetic mean and 1.02(GSD 1.06) for geometric mean by refractometer. Hippuric acid levels were 0.40 g/L(SD 0.51) by arithmetic mean and 0.20 g/L(GSD 3.59). In that case the exposed group was 1.40 g/L(SD 0.58) for arithmetic mean and 1.28 g/L(GSD 1.55) for geometric mean by HPLC method, 1.27 g/L(SD 0.56) for arithmetic mean and 1.14 g/L(GSD 1.62) for geometric mean by Jaffe method, 1.045 L(SD 0.27) for arithmetic mean and 1.02(GSD 1.13) for geometric mean by refractometer(P<0.05). Hippuric acid levels were 0.67 g/L(SD 0.79) for arithmetic mean and 0.39 g/L(GSD 2.94)(p<0.05). The urine creatinine concentrations were affected by gender(p < 0.01) but SG levels were not affected by gender or age(p>0.05). After adjustment, urine hippuric acid was correlated with creatinine(HPLC & Jaffe)(r=0.723, P<0.05, r=0.708, P<0.05) and SG(r=0.936, P<0.05) and the control group shows significantly higher than the case group. In the case group for adjusted urine hippuric acid was correlated with creatinine(HPLC & Jaffe), (r=0.736, P<0.05), r=0.549, P<0.05), SG(r=0.549, P<0.05). After adjusting urine hippuric acid by urine creatinine(HPLC and Jaffe method) and specific gravity, significant associations were found between the control group and case group, respectively(r=0.832, P<0.05, r=0.845, P<0.05) and (r=0.841, P<0.05, r=0.849, P<0.05). Specific gravity adjustment appears to be more appropriate for variations in the urine creatinine method. Conclusion: we found that urinary creatinine concentrations were significantly affected by gender, and other factors and that care should therefore be exercised when correcting urinary metabolites according to the urinary creatinine concentration in spot urine. It is determined that additional study is needed for biological monitoring.

Evaluation of Worker's Health and Occupational Exposure to Perchloroethylene in Laundries (Perchlotoethylene을 사용하는 세탁소 작업자들의 직업성 폭로와 건강에 관한 연구)

  • An, Sun-Hee;Lee, Jong-Hwoa;Park, Jong-An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.224-239
    • /
    • 1994
  • In this study we examined several subjective symptoms in an exposed group and an unexposed group to perchloroethylene. The exposed group consists to 30 workers employed in 23 dry-cleaning establishments located in Chung Cheung Do, whereas the unexposed group consists of 42 officers employed in a certain university. This study was conducted from October, 1993 to March, 1994. Also we investigated personal exposure levels and area concentration of PCE, and performed hematological and biochemical examination in blood and urine samples from the exposed group. The results are : 1. The exposed group highly complains several subjective symptoms, particularly in neuropsychiatry, eye, respiratory system and digestive system, compared with the unexposed group. But complaint rates in the exposed group are not related with PCE exposure levels. 2. PCE exposure levels for all dry-cleaning establishment varied widely, from 0.18 to 37.58ppm. The mean exposure level for centers of chain was 16.85ppm, and for local laundries was 8.83ppm, while for self-service establishment it was 3.07ppm. Eighty three percent of the workers were exposed less than the half-level(25.0ppm) of the Korea 50.0ppm standard for eight-hour PCE exposure. Seventeen percent of them exceeded the half-level of the Korea TLV. 3. Statistical correlation exists between the work load(number of operation cycles of equipment and the mass of processed textiles) and the personal exposure levels to be observed. 4. In hematological examination the values of WBC, RBC, Hgb, Hct, MCV, MCH, MCHC and PLT in the exposed group were within normal ranges. In biochemical examination(GOT, GPT, ALP, U-A and LDH) most of the items were within normal ranges. From this surveys conducted on 23 dry-cleaning establishments, the complaint rates of the exposed group to PCE in several subjective symptoms were higher than those of the unexposed group, and PCE exposure levels in all dry-cleaning establishment were below the Koera standard 50.0ppm. In hematological and biochemical examination the significant abnormalities by occupational exposure to PCE were not observed. However, the workers employed in dry-cleaning establishments are always faced with risk, becauses they are also exposed to several organic solvents used to remove stains. Therefore, various measures to improve occupational environment in dry-cleaning establishment should be considered.

  • PDF

Effects of Vibration Stimulation Therapy on Neglect of Stroke Patients (진동감각 자극치료가 뇌졸중 환자의 편측무시에 미치는 영향)

  • Jeon, So-Hyun
    • Journal of Society of Occupational Therapy for the Aged and Dementia
    • /
    • v.12 no.2
    • /
    • pp.87-95
    • /
    • 2018
  • Objective : Vibration stimulators are easier to obtain in clinical settings than other treatment tools, and it is advantageous that the arm activation training can be performed passively. Despite the following advantages, recent studies on vibration sense have not been activated yet. The purpose of this study was to investigate the effect of vibration sensation on the hands of the affected upper limb on unilateral reduction of stroke patients. Method : Patients with unilateral neglect due to stroke were enrolled in this study for about 3 weeks from October 19, 2018 to November 7, The research design used ABA design among the single-subject experimental research design, and a total of 18 circuits (4 baseline, 6 intervention, 3 baseline regression) were performed once a day on weekdays Respectively. MMES-K was used to select the subjects. Line bisection test (LBT), Albert's test and Star Cancellation Test (SCT) were used as unilateral neglect test. For the analysis, the baseline and intervention period measurements were visually analyzed using graphs and mean values were used. Result : All three evaluations showed that the number of errors missed during the training period was lower than the baseline period, and this decrease remained after training. The error was reduced by an average of $2{\pm}1.2$ omissions and an average omissions of $0.6{\pm}0.5$ omitting an average of $4.5{\pm}1$ omissions in the line break test. As a result of the Albert test, the average error decreased by $22.5{\pm}1.9$ omissions and $8{\pm}7.3$ omissions and $0.3{\pm}0.5$ omissions, respectively. In the star clearance test, the average error decreased from $26{\pm}4.6$ to $21.8{\pm}1.7$ and $20{\pm}0$, respectively. Conclusion : In this study, vibrotactile stimulation therapy showed a continuous effect on improving unilateral neglect. Based on these findings, further research should be conducted in order to improve objectivity in future studies. Further research on various arbitration methods that maximize the effect of intervention will be needed.

BONE DENSITY AND HISTOMORPHOMETRY ASSESSMENT OF DENTAL IMPLANT USING COMPUTERIZED TOMOGRAPHY (컴퓨터 영상을 이용한 임플란트 식립부위의 골밀도와 조직학적 연구)

  • Son, Jang-Ho;Choi, Byung-Hwan;Park, Soo-Won;Cho, Yeong-Cheol;Sung, Iel-Yong;Lee, Ji-Ho;Byun, Ki-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.136-142
    • /
    • 2009
  • Bone density in the recipient implant site seems to be an important factor for long term success of endosseous implants. Preoperative evaluation of bone density is very helpful to assist the clinician with the treatment planning of implant therapy. Accurate information on bone density will help the surgeon identify suitable implant sites, thereby improving the success rate of the procedure. Purpose; The aim of this study was to evaluate a correlation between bone density measured preoperatively with computerized tomography and histologically measured bone density by bone biopsy. Patients and methods; Twenty seven patients were selected. All the patients were in good health, with no systemic disorder and additional bone graft. Preoperatively the patients underwent CT scanning to evaluate Houmsfield Unit(HU). Each patients wore a surgical template for implant placement. During surgery 2mm in diameter and 6mm in length specimens were taken. Histomorphometric analysis was performed using digitalized image analysis software Axiovision 4.3. Also, the Resonance frequency analysis(RFA) and insertion torque values were recorded. Results; The highest histomorphometric values was found in the posterior mandible $32.3{\pm}3.8$, followed by $29.9{\pm}2.6$ for the posterior maxilla, $29.4{\pm}2.6$ for the anterior maxilla, $28.6{\pm}2.3$ for the anterior mandible(p=0.214). The hounsfield unit was $989.2{\pm}258.1$ in the posterior mandible, $845.0{\pm}241.5$ in the anterior maxilla, $744.5{\pm}92.6$ in the anterior mandible, $697.3{\pm}136.9$ in the posterior maxilla(p=0.045). This results may suggest that there are strong correlation between the histomorphometric values and hounsfield unit(r=0.760, p<0.05). The RF measurements were $81.9{\pm}2.4$ ISQ in the posterior mandible, $79.0{\pm}1.4$ ISQ in the anterior mandible, $78.3{\pm}4.6$ ISQ in the posterior maxilla, $76.5{\pm}5.0$ ISQ in the anterior maxilla(p=0.048). The insertion torque values was $43.2{\pm}4.2\;Ncm$ in the posterior mandible, $42.0{\pm}0.0\;Ncm$ in the anterior mandible, $41.3{\pm}4.1\;Ncm$ in the posterior maxilla, $40.8{\pm}3.8\;Ncm$ in the anterior maxilla(p=0.612). This results may suggest that there are statistical significance between the hounsfield unit and the insertion torque values(r=0.494, p<0.05), the histomorphometric values and the insertion torque values(r=0.689, p<0.05). But there was no correlation between histomorphometric values and ISQ. There was no statistical significance in age and gender effect on parameters. Conclusions; There was significant correlations between bone density and implant stability parameters. The bone density measurements using preoperative CT may help clinicians to predict primary stability before implant insertion, which is associated with implant survival rates.

Quality Characteristics of Baked Yackwa Made with Various Amounts of Goami Powder and Wheat Flour (고아미와 밀가루 배합 비율에 따른 구운 약과의 품질 특성)

  • Kim, Hyun-Ah;Yang, Jung-Su;Kim, Yong-Sik
    • Culinary science and hospitality research
    • /
    • v.19 no.1
    • /
    • pp.179-188
    • /
    • 2013
  • This study was performed to examine the quality characteristics of goami baked yackwa. To determine the optimal amount of wheat flour for goami powder yackwa((100, 80:20, 60:40, 40:60, 20:80, 100), the measurement of weight, hardness, moisture contents, color value and sensory evaluation were carried out(yackwa dough 14g: 12mm to the height of the mold was formed, Baked conditions: $160^{\circ}C$, 20Min., Dip conditions: $60^{\circ}C$, 30Min.). As a result, weight after baked or dipped in syrup were heavier when made with 100% of wheat flour yackwa. The moisture contents and hardness were the highest in 100% goami yackwa. L-values, a-values and b-values were also the highest in 100% goami yackwa. In a sensory evaluation, the overall preference were the highest in 100% goami yackwa and 100% wheat flour yackwa. From these results, goami was shown to be possible to make high quality yackwa.

  • PDF

The Effects of Subjective Beliefs and Values on Use Intention of Artificial Intelligence Robots: Difference according to Occupation and Employment (인공지능 로봇에 대한 주관적 신념과 가치가 이용의도에 미치는 영향: 직종 및 고용형태에 따른 차이 비교)

  • Seok, SeungHye
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.7
    • /
    • pp.536-550
    • /
    • 2018
  • This paper examine how acceptance of AI robots can be achieved according to occupational groups when the discourse on human labor and occupation changes due to the new industrial revolution is spreading steadily. Previous research on the acceptance of new technologies and products has predicted use behavior through subjective beliefs and values that do not change well over the short term. Therefore, this study compares the beliefs, values, and use intention of AI robots according to occupation. As a result, the subjective belief factor for AI robots was classified into belief in rationality(reason) and belief in benevolence(emotion). The value factors were divided into acceptance value(role performance, communication, social comparison) and avoidance value(risk, complexity). There was a significant difference in the effect of these on the use intention of AI robot by occupation and employment types. This result suggests that there are gaps in the occupation group at the rate of technology acceptance, as opposed to the existing prediction that AI robots will be rapidly expanded by professionals.

A Study on Composition of Solvent Thinners and Evaporation in the Air (일부 신나의 구성성분과 공기중 증발에 관한 연구)

  • Zoh, Kyung Ehi;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.245-263
    • /
    • 1997
  • For twelve solvent thinners, evaporation rates of components were investigated and models to estimate the actual concentration have been evaluated. Also, the current ACGIH TLVs (Threshold Limit Values) for the concentration of organic mixtures have been adjusted. The results of this study are summarized as follows : 1. Airborne concentrations of solvent thinner components were related to their respective vapor pressure (r=0.96). On the other hand, there was no significant relation between the concentrations in the air of the thinner compounds and the original amount in liquid form. 2. Airborne concentrations of each chemical were estimated by temperature at $8.5{\pm}1$, $16.7{\pm}1$ and $31.5{\pm}2^{\circ}C$ with an air velocity of 1.5 m/s. The concentrations were increased by increasing temperature (p<0.05). The percentage of concentrations were proportionate to their respective percentage of vapor pressure. Among the chemicals studied, n-butyl acetate, n-butyl alcohol, m-xylene, p-xylene and o-xylene showed a clear relationship to temperature. 3. Airborne concentration of each chemical was estimated by air velocity at 0.05, 1.50 and 2.50 m/s, with a constant temperature at $17{\pm}2^{\circ}C$. The concentrations were increased by increasing air velocity (p<0.05). The percentage of concentrations were proportionate to their respective percentage of vapor pressure. Among the chemicals studied, n-butyl alcohol, m-xylene and p-xylene showed a clear relationship to velocity. 4. In estimating the concentrations of solvent thinners by temperature and air velocity, ACGIH TLVs for mixtures tended to be larger than the values obtained by ACGIH exposure index. It shows that ACGIH TLVs for mixtures are not adequate for evaluating the airborne concentration of thinners and other organic mixtures. 5. The evaporation rate of the thinners were compared to the theoretical equations of Hummel, Braun and Mackay. The Hummel and Braun methods were close to exposure index but Makay's showed an underestimated value. In order to see the accuracy of each three models, the SSE (Error Sum of Squares) calculated for Hummel's was 1.73, being the closest to the actual values. 6. Present ACGIH TLVs for mixtures are not appropriate evaluate industrial environments. In this study, a correction of TLVs using vapor pressure of respective components was suggested. In order to evaluate the corrected TLVs a paired t-test was performed. There was no significant difference between the exposure index and the concentration over suggested TLVs (p>0.05). Thus, this corrected TLVs seem appropriate in order to evaluate actual industrial workplaces organic chemical concentration in the air.

  • PDF

Investigation of the Guidance Levels for Protecting Populations from Chemical Exposure and the Estimation of the Level of Concern Using Acute Toxicity Data (화학사고 시 수용체 보호를 위한 독성끝점 농도와 급성독성 자료를 활용한 우려농도 예측값 조사)

  • Lee, Jiyun;Kim, Sunshin;Yang, Wonho;Yoon, Junheon;Ryu, Jisung;Kim, Jungkon;Ji, Kyunghee
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.1
    • /
    • pp.44-54
    • /
    • 2018
  • Objectives: To protect individuals working at the site as well as the surrounding general population from a chemical accident, several emergency exposure guidance levels have been used to set a level of concern for certain chemicals. However, a level of concern has not been established for many substances that are frequently used or produced in large quantities in Korean workplaces. In the present study, we investigated the guidance levels for protecting populations from chemical exposure and the estimation of level of concern using acute inhalation and oral toxicity data. Methods: The number of chemicals to which emergency exposure guidance levels (e.g., ERPG-2, AEGL-2, PAC-2, and IDLH) can be applied were determined among 822 hazardous chemicals according to the 'Technical Guidelines for the Selection of Accident Scenarios (revised December 2016)'. The ERPG and AEGL values were compared across all three tiers for the 31 substances that appeared on both lists. We examined the degree of difference between the emergency exposure guidance levels and the estimates of level of concern calculated from acute inhalation or acute oral toxicity data. Results: Among the 822 hazardous chemicals, emergency exposure guidance levels can be applied to 359 substances, suggesting that the estimates of level of concern should be calculated using acute toxicity data for 56.3% of the hazardous chemicals. When comparing the concordance rates of ERPG and AEGL for 31 substances, the difference between the two criteria was generally small. However, about 40% of the substances have values diverging by more than three-fold in at least one tier. Such discrepancies may cause interpretation and communication problems in risk management. The emergency exposure guidance levels were similar to the estimates of level of concern calculated using acute inhalation toxicity data, but the differences were significant when using acute oral toxicity data. These results indicate that the level of concern derived from acute oral toxicity data may be insufficient to protect the population in some cases. Conclusion: Our study suggests that the development of standardized guidance values for emergency chemical exposure in the Korean population should be encouraged. It is also necessary to analyze acute toxicity data and fill the information gaps for substances that are important in Korean workplace situations.

A Comparative Analysis of Whole Blood Cadmium by Atomic Absorption Spectrophotometry with a Graphite Furnace (흑연로 원자흡수분광법에 의한 혈액중 카드뮴 정량분석)

  • Park, Jong An;Oh, Hye Jeong;Lee, Jong Hwa
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.301-312
    • /
    • 1996
  • This study was performed to search a optimal analyzing method of cadmium in whole-blood. Cadmium was determined by graphite furnace atomic absorption spectrometry(GFAAS). We investigated the effect of ashing temperature on the absorbance of cadmium in a simple dilution(ten-fold) method with triton X-100 and matrix modifier methods treated with $NH_4H_2PO_4$(1 and 3%) and $Pd(NO_3)_2$(0.00l and 0.005%) as matrix modifier. We also compared the reported reference values of standard blood with values resulted from optimal analyzing conditions of this study. In case of a simple dilution method, when ashing temperature was set at $450^{\circ}C$, the absorbance of sample and background were $0.334{\pm}0.012$ and $1.382{\pm}0.245$, respectively. Background level was higher than the value(0.8) that can be corrected by $D_2$ background correction method. As ashing temperature was rised to $500^{\circ}C$, the absorbance of sample and background were $0.178{\pm}0.008$ and $0.711{\pm}0.223$ respectively. The higher ashing temperature($450^{\circ}C-650^{\circ}C$) was, the lower the absorbance of sample was. In case of a matrix modifier method with $NH_4H_2PO_4$(1 and 3%), when ashing temperature was rised from $500^{\circ}C$ to $650^{\circ}C$, the absorbance of sample slightly changed. The absorbances of sample at $600^{\circ}C$ were $0.230{\pm}0.017$ and $0.137{\pm}0.012$, respectively. These values were larger than that of simple dilution method. But the absorbance of background was higher than the level that can be corrected by $D_2$ method. In case of a matrix modifier method with $Pd(NO_3)_2$(0.001 and 0.005%), the absorbance of sample and background were higher than those of other methods and were stable and reproducible. When ashing temperature was over $550^{\circ}C$, the absorbance of sample was significantly decreased. In case of 0.005% $Pd(NO_3)_2$ carbon residue remained in graphite tube affected the absorbance of sample and background. From these results, We propose that in case of a simple dilution(ten-fold) method with triton X-100 ashing temperature must be maintained below $400^{\circ}C$. In order to diminish the absorbance of background, the alternative method is attenuation of injection volume or multiplication of dilution ratio. We recommend $Pd(NO_3)_2$ than $NH_4H_2PO_4$ as a matrix modifier. In case of a matrix modifier method with $Pd(NO_3)_2$ ashing temperature might be maintained below $550^{\circ}C$.

  • PDF

Rapid HPLC Method for the Simultaneous Determination of Eight Urinary Metabolites of Toluene, Xylene and Styrene

  • Lee, Cheol-Woo;Lee, Jeong-Mi;Lee, Jae-Hyun;Eom, Han-Young;Kim, Min-Kyung;Suh, Joon-Hyuk;Yeom, Hye-Sun;Kim, Un-Yong;Youm, Jeong-Rok;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.9
    • /
    • pp.2021-2026
    • /
    • 2009
  • Toluene, xylene and styrene are volatile organic solvents that are commonly used in mixtures in many industries. Because these solvents are metabolized and then excreted in urine, their urinary metabolites are thought to be biomarkers of occupational exposure to these solvents. Therefore, a simple, rapid, and yet reliable analytical method for determining the metabolites is required for accurate biological monitoring. In the present study, a simple and rapid HPLC-UV method was developed for the simultaneous determination of eight major metabolites of toluene, xylene and styrene: hippuric acid (HA), mandelic acid (MA), o-, m- and p-methylhippuric acids (o-, m- and p-MHAs), and o-, m- and p-cresols. A monolithic column was employed as the stationary phase and several conditions, including flow rate, composition of mobile phase and column temperature, were variables for the optimization of the chromatographic resolution. All eight metabolites were successfully resolved within 5 minutes in 10% aqueous ethanol containing 0.3% acetic acid and 1.6% $\beta$-cyclodextrin, using a flow rate gradient of 1.0 - 5.0 mL/min at 25 ${^{\circ}C}$. The performance of this method was validated by linearity, intra- and inter-day accuracy, and precision. The linearity was observed with correlation coefficients of 0.9998 for HA, 0.9999 for MA, 0.9989 for o-MHA, 0.9998 for m-MHA, 0.9991 for p-MHA, 0.9997 for o-cresol, 0.9998 for m-cresol, and 0.9986 for p-cresol. The intra- and inter-day precision of the method were less than 5.89% (CV) and the accuracy ranged from 92.95 to 106.62%. The validity was further confirmed by analysis of reference samples that were prepared by the inter-laboratory quality assurance program of the Korea Occupational Safety and Health Agency (KOSHA, Seoul, Korea). All measured concentrations of the analytes agreed with the certified values.