• Title/Summary/Keyword: Occupational Values

Search Result 438, Processing Time 0.036 seconds

The Measurement and Estimation of Minimum Flash Point Behavior for Binary Mixtures Using Tag Open-Cup Tester (Tag 개방식 장치를 이용한 이성분계 혼합물의 최소인화점 현상의 측정 및 예측)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.50-55
    • /
    • 2008
  • The flash points for the systems, ethlybenzene+n-butanol and ethlybenzene+n-hexanol, were measured by using Tag open-cup tester (ASTM D1310-86). These binary mixtures exhibited MFPB (minimum flash point behavior), which leads to the minimum on the flash point vs composition curve. The experimental data were compared with the values calculated by the Raoult's law, the UNIQUAC equation and the NRTL equation. The calculated values based on the UNIQUAC and NRTL equations were found to be better than those based on the Raoult's law. It was concluded that the UNIQUAC and NRTL equations were more effective than the Raoult' law at describing the activity coefficients for nonideal solution such as the ethlybenzene+n-butanol and ethlybenzene+n-hexanol systems. And the predictive curve of the flash point prediction model based on the NRTL equation described the experimentally-derived data more effectively than was the case when the prediction model was based upon the UNIQUAC equation.

  • PDF

Flash Point Determination of Binary Liquid Solution Containing Nonflammable Component (비가연성 성분을 포함한 이성분계 액상 용액의 인화점 결정)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.3
    • /
    • pp.40-45
    • /
    • 2019
  • Flash point is the important flammability indicator characterizing the risk of fire and explosion of flammable liquid mixture. In this study, flash points of water+formic acid and water+acrylic acid were measured by Seta flash apparatus. The flash points estimated by the methods based on empirical equation and Raoult's law were compared with experimental flash points. Absolute average errors of the results estimated by Raoult's law are $10.7^{\circ}C$ and $4.8^{\circ}C$ for water+formic acid and water+acrylic acid, respectively. Absolute average errors of the results estimated by empirical equation are $1.0^{\circ}C$ and $0.5^{\circ}C$ for water+formic acid and water+acrylic acid, respectively. In conclusion, the estimated values by empirical equation simulated the measured values better than those calculated by Raoult's law.

A Study on the Selection of Candidates for Substances Subject to Permission Using Chemicals Ranking and Scoring (CRS) (화학물질 우선순위 선정기법(CRS)을 활용한 허가대상 후보물질 선정 연구)

  • Kim, Hyo-dong;Park, Kyo-shik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.3
    • /
    • pp.253-267
    • /
    • 2022
  • Objectives: This study was performed to check whether the CRS (Chemical Ranking and Scoring) system is appropriate as a method to determine substances as candidates for substances subject to permission and to apply this system to the selection of candidates for substances subject to permission. Methods: A risk score was obtained by multiplying the hazard score and the exposure score and then ranking them. The hazard sub-indicators are carcinogenicity, germ cell mutagenicity, reproductive toxicity, specific target organ toxicity-repeated exposure, respiratory sensitization and endocrine disrupting chemicals. Exposure sub-indicators are persistence, bioaccumulation and emission volume. Sensitivity analysis was performed for missing values. Correlation analysis and multivariable linear regression analysis were performed among hazard, exposure and risk in order to confirm that CRS was an appropriate method. Results: As a result of the sensitivity analysis on missing values, it was confirmed that the effect on the risk ranking was not sensitive. Correlation and regression analysis confirmed that exposure had a greater effect on risk than hazard. Conclusions: The CRS system, which derives a risk score using a hazard and exposure score, is judged to be appropriate as a method for the selection of preliminary of candidates for substances subject to permission. Benzene, cadmium, nickel, and cobalt were selected as priority candidates for substances subject to permission.

Evaluation of Single and Binary Mixture Toxicity of Organic UV-Filters Using H295R Cells (H295R 세포를 활용한 유기 UV-Filters의 단일 및 혼합독성 평가)

  • Bomee Lee;Inhye Lee;Kyunghee Ji
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.3
    • /
    • pp.201-211
    • /
    • 2024
  • Background: Organic ultraviolet (UV) filters are widely used in sunscreen products and have been identified as an emerging contaminant. Organic UV filters co-exist with multiple components, but their mixture toxicity remains largely unknown. Objectives: We investigated the toxicity of single and binary mixtures of commonly used UV-filters using the human adrenocarcinoma (H295R) cell line. Methods: After exposure to non-cytotoxic concentrations of avobenzone (AVO), homosalate (HS), octisalate (OS), octinoxate (OMC), and octocrylene (OC), the levels of testosterone (T) and 17β-estradiol (E2) were measured. The median effective concentration (EC50) values for the E2 of the individual substances were used to determine the mixture effect of four binary combinations: OMC+AVB, OMC+HS, OMC+OS, and OMC+OC. The synergistic, additive, and antagonistic effects of the mixture were determined by calculating toxic units (TU). To examine the mechanism of mixture toxicity, eight genes involved in steroidogenesis were analyzed using the real-time polymerase chain reaction. Results: The significant increase in E2 in H295R cells exposed to AVO, HS, OS, OMC, and OC suggest an estrogenic effect of the tested UV-filters. A significant decrease in T was observed in cells exposed to HS and OS. EC50 values for E2 increase were 105 nM for AVO, 110 nM for HS, 120 nM for OS, 55 nM for OMC, and 80 nM for OC. Both binary mixtures consisting of OMC+HS and OMC+OS have synergistic effects. Conclusions: Our results showed that five types of UV-filter substances increase E2 in H295R cells. We examined the mixture toxicity in terms of increased estrogenicity and confirmed that E2 significantly increased when OMC was mixed with a salicylate-based UV-filters. These findings highlight the importance of determining the impact of UV filter mixtures.

Comparing the Effects of Hip Exercises versus Ankle Stabilization Exercises in Subjects with Chronic Ankle Instability (만성 발목 불안정 대상자에 대한 엉덩이근육운동과 발목안정화운동의 효과 비교)

  • Jin-Seok Han;Seung-Chul Chon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.3
    • /
    • pp.49-59
    • /
    • 2024
  • Purpose : Chronic ankle instability (CAI) can impair strength and balance, leading to activity limitations and restricted participation. Traditionally, ankle stabilization exercises have been applied, and more recently, the effects of hip muscle exercises have been studied. The purpose of this study was to determine the immediate effects of hip exercises (HE) and ankle stabilization exercises (ASE) on dynamic balance, performance and ankle function in subjects with CAI. We also compared the difference in effectiveness between HE and ASE. Methods : A total of 34 subjects with CAI participated, ane were randomly divided into two groups: the HE group and the ASE group. The HE group performed a program consisting of exercises above 70 % MVIC, while the ASE group performed a traditional ankle stabilization exercise program. The subjects in each group completed their respective exercise program for a total of 30 minutes once a day and were assessed before and after the intervention. Dynamic balance was assessed using the Y-balance test (YBT). Performance was assessed using the hop for distance test (HDT), and side-hop test (SHT). Ankle function was assessed using foot and ankle ability measure (FAAM) questionnaires. Results : YBT, HDT, and FAAM values increased significantly in both groups after the intervention (p<.05), and there was no significant difference between the groups. SHT values decreased significantly in both groups after the intervention (p<.05), and there was no significant difference between the groups. Conclusion : Although no significant superiority was observed between HE and ASE in this study, both exercise programs were effective in improving dynamic balance, performance, and ankle function in subjects with CAI. These findings suggest that both HE and ASE can be suitable interventions for CAI, highlighting the need for individualized treatment plans. Future research is warranted to explore the long-term effects of exercise programs on CAI subjects of different ages and occupational characteristics.

Characteristic comparison of Andersen and total suspended particulate samplers in a particulate matter generation chamber (입자 발생 챔버를 이용한 Andersen과 총분진 시료채취기의 특성 비교)

  • Park, Ju-Myon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.3
    • /
    • pp.177-184
    • /
    • 2008
  • The purpose of this study was to compare the performance characteristics of Andersen and total suspended particulate (TSP) samplers in terms of particle size distribution (PSD) and mass sampling efficiency. In the present study, two Andersen and four TSP samplers were selected and tested to quantitatively estimate human exposure to fly ash representing industrial particulate matter (PM) in a carefully controlled chamber. The PSD characteristics, a mass median aerodynamic diameter and a geometric standard deviation, were found from the sampled PM of airborne samplers in the chamber. An Andersen sampler was compared with a TSP sampler quantified by a coulter counter multisizer, as a reference sampler, to describe the correlation of mass sampling efficiencies between two types of samplers. Overall results indicate that Andersen samplers overestimated small PM due to particle bounce phenomena between impaction stages. There was reasonably good correlation ($R^2$ = 0.89 and 0.91) between the mass sampling efficiencies of Andersen and TSP samplers during the two tests. However, the lower values of slope (0.71 and 0.72) in two tests showed that the Andersen sampler underestimated PM (> AD $10.1\;{\mu}m$) with sufficient inertia due to a relatively lower Andersen inlet velocity at 0.8 m/s comparing with the operating air velocity at 2.1 m/s in the sampling zone of a chamber.

A Study on Fume Formation Ratio on Flux Cored Arc Welding Process (플럭스 코어드 아크 용접 공정에서의 흄 형성량에 관한 연구)

  • Yoon, Chung-Sik;Paik, Nam-Won
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.108-112
    • /
    • 1999
  • A study was conducted for the effects of input energy on fume formation ratios based on electrode(FFR$_{electrode}(g/kg_{electrode})),\;deposited\;metal(FFR_{weld}(g/kg_{weld}))\;and\;slag(FFR_{slag}(g/kg_{slag}))\;at\;CO_2$ flux cored arc welding on stainless steel. Experiments were run in well designed welding fume box. Six types of flux cored wires were used and three levels of current and voltages were given. The measured values of $FFR_{electrode},\;FFR_{weld},\;FFR_{slag}\;are\;7.90{\pm}1.47\;g/kg_{electrode},\;9.18{\pm}1.65\;g/kg_{\electrode},\;71.8{\pm}24.2\;g/kg_{slag}$ respectively. Fume formation ratios are not increased dramatically by input energy because of simultaneous increasing of melted electrodes, deposited metal and slag. The results indicate that the test of fume formation ratios in the research on production of low fume welding wire can be run at the fixed condition of input energy rather than various condition.

  • PDF

Study on Male Nursing College Students' Subjectivity in Their Attitude toward Jobs (남자 간호 대학생의 직업 가치관에 대한 주관적 구조)

  • Doo, Hyun-Jung;Kim, Yoon-Sook
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.14 no.2
    • /
    • pp.167-175
    • /
    • 2008
  • Purpose: The purpose of this study was to explore the structure and characteristics of male college nursing students' personality-based career attitudes. Method: The Q-methodology was used to identify factors in male nursing students' personality-based career attitudes. A Q sample was collected from literature reviews (Kim & Kim, 2005). The subjects consisted of 30 male nursing students. Result: The results of the study show that male nursing students can be categorized into four types. The five factors extracted all had eigen values greater than 1.0 and explained approximately 50.84% of the variation in responses (32.62, 7.59, 5.70 and 4.93% respectively). The categories were labeled 'Repair intention style', 'Belief intention style', 'Stability intention style', and 'Self-regulation intention style'. Conclusion: Through a process that analyzes subjective structure, male nursing students' personality based career attitudes create occupational consciousness, professional accomplishment and professional ethics as a nursing profession. Content of curriculum and development of a reasonable and realistic course consultation program should be done.

The Compatibility of MSDS through the Investigation of the Combustible Properties for MEK (MEK의 연소특성 고찰을 통한 MSDS의 적정성)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.3
    • /
    • pp.36-41
    • /
    • 2008
  • For the safety design and operation of many chemical process, it is necessary to know certain explosion limit, flash point and autoignition temperature(AIT) of handling substances. Also it is necessary to know explosion limit at high temperature and pressure. For the safe handling of MEK(methyl ethyl ketone), explosion limit at $25^{\circ}C$ and the temperature dependence of the explosion limits were investigated. And flash point and AIT for MEK were experimented. By using the literatures data, the lower and upper explosion limits of MEK recommended 1.8 vol% and 11.0 vol%, respectively. In this study, measured the lower and upper flash points of MEK were $-5^{\circ}C$ and $22^{\circ}C$, respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for MEK, and the experimental AIT of MEK was $507^{\circ}C$. The new equations for predicting the temperature dependence of the explosion limits of MEK is proposed. The values calculated by the proposed equations were a good agreement with the literature data.

SHIELD DESIGN OF CONCRETE WALL BETWEEN DECAY TANK ROOM AND PRIMARY PUMP ROOM IN TRIGA FACILITY

  • Khan, M J H;Rahman, M;Ahmed, F U;Bhuiyan, S I;Haque, A;Zulquarnain, A
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.190-193
    • /
    • 2007
  • The objective of this study is to recommend the radiation protection design parameters from the shielding point of view for concrete wall between the decay tank room and the primary pump room in TRIGA Mark-II Research Reactor Facility. The shield design for this concrete wall has been performed with the help of Point-kernel Shielding Code Micro-Shield 5.05 and this design was also validated based on the measured dose rate values with Radiation Survey Meter (G-M Counter) considering the ICRP-60 (1990) recommendations for occupational dose rate limit ($10{\mu}Sv/hr$). The recommended shield design parameters are: (i) thickness of 114.3 cm Ilmenite-Magnetite Concrete (IMC) or 129.54 cm Ordinary Reinforced Concrete (ORC) for concrete wall A (ii) thickness of 66.04 cm Ilmenite-Magnetite Concrete (IMC) or 78.74 cm Ordinary Reinforced Concrete (ORC) for concrete wall B and (iii) door thickness of 3.175 cm Mild Steel (MS) on the entrance of decay tank room. In shielding efficiency analysis, the use of I-M concrete in the design of this concrete wall shows that it reduced the dose rate by a factor of at least 3.52 times approximately compared to ordinary reinforced concrete.