Implantable Flexible Sensor for Telemetrical Real-Time Blood Pressure Monitoring using Polymer/Metal Multilayer Processing Technique (폴리머/ 금속 다층 공정 기술을 이용한 실시간 혈압 모니터링을 위한 유연한 생체 삽입형 센서)

  • Lim Chang-Hyun;Kim Yong-Jun;Yoon Young-Ro;Yoon Hyoung-Ro;Shin Tae-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.599-604
    • /
    • 2004
  • Implantable flexible sensor using polymer/metal multilayer processing technique for telemetrical real-time blood pressure monitoring is presented. The realized sensor is mechanically flexible, which can be less invasively implanted and attached on the outside of blood vessel to monitor the variation of blood pressure. Therefore, unlike conventional detecting methods which install sensor on the inside of vessel, the suggested monitoring method can monitor the relative blood pressure without injuring blood vessel. The major factor of sudden death of adults is a disease of artery like angina pectoris and myocardial infarction. A disease of circulatory system resulted from vessel occlusion by plaque can be preventable and treatable early through continuous blood pressure monitoring. The procedure of suggested new method for monitoring variation of blood pressure is as follows. First, integrated sensor is attached to the outer wall of blood vessel. Second, it detects mechanical contraction and expansion of blood vessel. And then, reader antenna recognizes it using telemetrical method as the relative variation of blood pressure. There are not any active devices in the sensor system; therefore, the transmission of energy and signal depends on the principle of mutual inductance between internal antenna of LC resonator and external antenna of reader. To confirm the feasibility of the sensing mechanism, in vitro experiment using silicone rubber tubing and blood is practiced. First of all, pressure is applied to the silicone tubing which is filled by blood. Then the shift of resonant frequency with the change of applied pressure is measured. The frequency of 2.4 MHz is varied while the applied pressure is changed from 0 to 213.3 kPa. Therefore, the sensitivity of implantable blood pressure is 11.25 kHz/kPa.

THE STUDY ON THE PERIODONTAL VASCULAR CHANGES OF RAT INCISORS FOLLOWING EXPERIMENTAL TOOTH MOVEMENT (실험적 치아이동시 백서 상악절치 치근막의 혈관 변화에 대한 연구)

  • Hyun, Seong-Wook;Suhr, CheonsG-Hoon
    • The korean journal of orthodontics
    • /
    • v.18 no.2
    • /
    • pp.311-327
    • /
    • 1988
  • Vascular changes in the periodontal ligament of the rat incisors following application of experimental orthodontic forces were examined by the India ink perfusion method. 57 rats were used for this experiment. The rats were divided into experimental group (54 rats) and control group (3 rats). 54 experimental rats were divided into group I (27 rats) and group II (27 rats). The right and left upper incisors of group. I and group II rats were separated distally with forces of 20gm, 70gm respectively. The vascular changes of periodontal ligament were observed histologically by means of light microscope after 1, 2 and 3 days of tooth movement and 1,3,5,8,14, and 21 days after removal of orthodontic force. The results were as follows; 1. After one day of tooth movement, occlusion of blood vessels, hyalinization of periodontal ligament and resorption of alveolar bone adjacent to the alveolar crest on pressure side were observed. Above the tissue changes on the pressure side of group II were more severe than those of group I. Especially, septal bone of group II was separated after 2 days of tooth movement. 2. In tension zones, periodontal space was widened and periodontal fibers were orientated in the direction of puil. The blood vessels of periodontal ligament were distended. New bone deposition was seen along the inner surface of the alveolus after 2 days of tooth movement. 3. After 3 days of tooth movement, deposition of new bone was seen along the periosteal surface of alveolar bone on pressure side, progressing with increasing after removal of orthodontic force. Remodelling of the new bone was occurred 5 days after removal of orthodontic force. 4. 3 days after removal of orthodontic force, invasion of blood vessels into the marginal periodontal ligament on pressure side was observed clearly and the vessels below the epithelial attachment were increased. 5. After removal of orthodontic force, hyalinized structures disappeared concomittantly with an invasion of blood vessels from the neighboring periodontal ligament. 14 days after removal of orthodontic force, the vessels in the periodontal ligament of group I were finished the vascular rearrangement. 21 days after removal of orthodontic force, the vessels in the periodontal ligament of group II were finished the vascular rearrangement.

  • PDF

The Characteristics of Voice Onset Time of the Korean Stops in the Benign Laryngeal Disorders (후두질환에 따른 자음의 음성발현시간의 특성)

  • Hong, Ki-Hwan;Lee, Hwa-Uk;Kim, Jin-Sung;Lee, Eun-Jung;So, Sang-Soo;Choi, Dong-Il;Ynng, Yoon-Soo
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.17 no.2
    • /
    • pp.98-102
    • /
    • 2006
  • Background and Objectives : Voice onset time(VOT) is defined as the time interval from oral release of a stop consonant to the onset of glottal pulsing in the following vowel. VOT is a temporal characteristics of stop consonants that reflects the complex timing of glottal articulation relative to supraglottal articulation. Stop consonants are characterized by creation of a pressure difference across a complete occlusion in the vocal tract, followed by a sudden release 'burst' due to opening that occlusion. The objects of this study is to evaluate a usefulness of voice onset time in the assessment of voice disorderd patients. Subjects : Subjects were 20 adults with normal voice and with benign laryngeal disorders. Subjects with voice disorders represented the following vocal pathologies : vocal polyp, vocal nodule, Reinke's edema and unilateral vocal fold paralysis(UVFP). Control subjects were matched for age (21-40 yews old) and sex(male) with the voice disorders subjects and had normal vocal qualities with no history of voice disorders. Methods : Each voice-disordered and matched control subject read the test passages containing three types of Korean bilabial consonants. VOT measures were made for the initial $/p/p^h/\;and\;/p'/$. VOT was measured using acoustic waveform or wide band spectrogram. Results : For each voiceless stop consonants, there was a significant difference in VOT between the voice disordered and normal subjects. The mean VOTs of the lax stops in UVFP was significantly shorter than those of control subjects in the UVFP. The mean VOTs of the aspirated stops in the vocal polyp and nodule were longer than those of control subjects, but not significant. The mean VOTs of the glottalized in voice disordered groups were longer than those of control subjects, and significant statistically in the UVFP. Conclusions : VOT may be a clinically useful acoustic parameter in the assessment of voice disordered patients, especially in the unilateral vocal fold paralysis.

  • PDF

Development of Artificial Vessels with Autologous Bone Marrow Cells and Polymers (자기 골수세포와 고분자 폴리머를 이용한 인공 혈관의 개발)

  • Choi, Jin-Wook;Lim, Sang-Hyun;Hong, You-Sun;Kim, Byung-Soo
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.160-169
    • /
    • 2008
  • Bakcground: To treat anastomosis site stenosis and occlusion of the artificial vessels used in vascular surgery, tissue-engineered artificial vessels using autologous cells have been constructed. We developed artificial vessels using a polymer scaffold and autologous bone marrow cells and performed an in vivo evaluation. Material and Method: We manufactured a vascular scaffold using biodegradable PLCL (poly lactide-co-${\varepsilon}$-caprolactone) and PGA (poly glycolic acid) fibers. Then we seeded autologous bone marrow cells onto the scaffold. After implantation of the artificial vessel into the abdominal aorta, we performed an angiography 3 weeks after surgery. After the dogs were euthanized we retrieved the artificial vessels and performed histological analysis. Result: Among the six dogs, 2 dogs died of massive bleeding due to a crack in the vascular scaffold 10 days after the operation. The remaining four dogs lived for 3 weeks after the operation. In these dogs. the angiography revealed no stenosis or occlusion at 3 weeks after the operation. Gross examination revealed small thrombi on the inner surface of the vessels and the histological analysis showed three layers of vessel structure similar to the native vessel. Immunohistochemical analysis demonstrated regeneration of the endothelial and smooth muscle cell layers. Conclusion: A tissue engineered vascular graft was manufactured using a polymer scaffold and autologous bone marrow cells that had a structure similar to that of the native artery. Further research is needed to determine how to accommodate the aortic pressure.

Cardiovascular Responses and Nitric Oxide Production in Cerebral Ischemic Rats

  • Shinl, Chang-Yell;Lee, Nam-In;Je, Hyun-Dong;Kim, Jeong-Soo;Sung, Ji-Hyun;Kim, Dong-Seok;Lee, Doo-Won;Bae, Ki-Lyong;Sohn, Uy-Dong
    • Archives of Pharmacal Research
    • /
    • v.25 no.5
    • /
    • pp.697-703
    • /
    • 2002
  • We investigated that the role of nitric oxide (NO) on ischemic rats in brain and heart. Ischemia was induced by both common carotid arteries (CCA) occlusion for 24h following reperfusion. Then tissue samples were removed and measured NOx. In brain, NOx was increased by about 40% vs. normal and it was significantly inhibited by aminoguanidine, selective iNOS inhibitor. This result showed that NOx concentration was increased by iNOS. We investigated the role of $Ca^{2+}$ during ischemia. Nimodipine, L-type calcium channel blocker, didn't inhibit the increases of NOx concentration during ischemia. It suggested that increased NOx was due to calcium-independent NOS. MK-801, which N-methyl-D-aspartate (NMDA) receptor antagonist, didn't significantly prevent the increases of NOx. In heart, ischemia caused NOx decrease and it is inconsistent with NOx increase in brain. Aminoguanidine and nimodipine didnt affect on NOx decrease. But MK-801 more lowered NOx concentration than those of ischemia control group. It seemed that $Ca^{2+}$ influx in heart partially occurred via NMDA receptor and inhibited by NMDA receptor antagonist. The mean arterial pressure (MAP) in ischemic rats after 24h of CCA occlusion was decreased when compared to normal value, whereas the heart rates (HR) was not different between two groups. Aminoguanidine or MK801 had no effect on MAP or HR, but nimodipine reduced MAP. There was no difference the effects of aminoguanidine, nimodipine, or MK-801, on MAP and HR between normal rats and ischemic rats. In summary, ischemic model caused an increase of NOx concentration, suggesting that this may be produced via iNOS, which is calcium independent in brain. However in heart, ischemia decreased NOx concentration and NMDA receptor was partially involved. The basal MAP was decreased in ischemic rats but HR was not different from normal control, suggesting that increased NOx in brain of ischemic rat may result in the hypotension.

The Influences of Obstructive Apneas on Changes of Cardiovascular Function in Anesthetized Dogs with $\alpha$-chloralose ($\alpha$-chloralose로 마취한 개에서 폐쇄성 무호흡이 심혈관계 기능변화에 미치는 영향)

  • Jang, Jae-Soon;Kang, Ji-Ho;Lee, Sang-Haak;Choi, Young-Mee;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.3
    • /
    • pp.347-356
    • /
    • 2000
  • Background : Patients with obstructive sleep apnea syndrome are known to have high long-term mortality compared to healthy subjects because of their cardiovascular dysfunction. The observation of hemodynamic changes by obstructive apneas is helpful when attempting to understand the pathophysiological mechanism of the development of cardiovascular dysfunction in those patients. Therefore, we studied the changes in cardiovascular function with an animal model and tried to obtain the basic data for an ideal experimental model (this phrase is unclear), a requirement for a more advanced study. Methods : Sixteen anesthetized dogs with ${\alpha}$-chloralose delete were divided into two groups : 8 dogs of room air breathing group and 8 dogs of oxygen breathing group. We measured $PaO_2$, $PaCO_2$, heart rate, cardiac output, mean femoral artery pressure, and mean pulmonary artery pressure at specified times during the apnea-breathing cycle before endotracheal tube occlusion (baseline), 25 seconds after endotracheal tube occlusion (apneic period), 10 seconds (early phase of postapneic period, EPA) and 25 seconds (late phase of postapneic period, LPA) after spontaneous breathing. Results : In room air breathing group, the heart rate significantly decreased during the apneic period compared to that at baseline (P<0.01) and increased at EPA and LPA compared to that during the apneic period (P<0.01). But, the heart rate showed no significant changes during apneic and postapneic periods in the oxygen breathing group. Cardiac output tended to decrease during apneic period compared to that at baseline, but was statistically significant. Cardiac output significantly decreased at LP A compared to at baseline (P<0.01). Mean femoral artery pressure was significantly decreased at during apneic period compared to that at baseline (P<0.05). Conclusion : Through this experiment, we were partially able to understand the changes of cardiovascular function indirectly, but delete new experimental animal model displaying physiological mechanism close to natural sleep should be established, and the advanced study in the changes of cardiovascular function and their causes should be continued.

  • PDF

Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation (요골동맥 직경 변화에 따른 맥파 측정 시스템 개발)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Kim, Jong-Yeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.

Anti-inflammatory effect of non-thermal atmospheric pressure plasma for periodontitis treatment: in vitro pilot study (치주염 치료를 위한 저온상압 플라즈마의 항염효과: 예비 실험)

  • Park, You li;Kim, Hyun-Joo;Lee, Ju-Youn;Jeong, Sung-Hee;Kwon, Eun-Young;Joo, Ji-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.2
    • /
    • pp.88-94
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the anti-inflammatory effects of non-thermal atmospheric pressure plasma (NTP) on human gingival fibroblasts (HGFs) for clinical application of periodontal treatment. Materials and Methods: HGFs were treated with Porphyromonas gingivalis (Pg) lipopolysaccharide (LPS). Customized NTP device was developed for periodontal in vitro study. Cell viability was evaluated with cell counting kit-8. The levels of inflammatory cytokines, including interleukin (IL)-8 and 6, were determined by enzyme-linked immunosorbent assay. Results: When NTP was applied, the cell viability did not change significantly, and there was no difference for 6 h and 24h. When Pg LPS was treated to HGFs, the secretion of IL-8 and IL-6 was increased compared to the control group. But when the NTP was applied, the secretion of them was significantly decreased. Conclusion: NTP did not affect cell viability of HGFs. And it inhibited the LPS-induced production of IL-8 and IL-6.

Comparisons of occlusal force according to occlusal relationship, skeletal pattern, age and gender in Koreans (한국인에서의 부정교합 여부와 골격형태, 연령, 성별에 따른 교합력의 비교)

  • Yoon, Hye-Rim;Choi, Yoon-Jeong;Kim, Kyung-Ho;Chung, Choo-Ryung
    • The korean journal of orthodontics
    • /
    • v.40 no.5
    • /
    • pp.304-313
    • /
    • 2010
  • Objective: The aim of this study was to evaluate the occlusal force and contact area and to find its associating factors in Koreans. Methods: Occlusal force and contact area in maximum intercuspation were measured using the Dental $Prescale^{(R)}$ system in 651 subjects (15 with normal occlusion, 636 with various malocclusions divided into subgroups according to the skeletal pattern, Angle's molar relationship, age and gender). Results: Occlusal force of the normal occlusion group ($744.5{\pm}262.6N$) was significantly higher than those of the malocclusion group ($439.0{\pm}229.9N$, $p$ < 0.05). Occlusal force was similar regardless of differences in ANB angle or Angle's molar classification, however the increase in vertical dimension significantly reduced occlusal force ($p$ < 0.05). Conclusions: Occlusal force was significantly lower in the malocclusion group compared to the normal occlusion group, and in females compared to males, but it was not affected by age, antero-posterior skeletal pattern or molar classification. Although a hyperdivergent facial pattern indicated lower occlusal force compared to a hypodivergent facial pattern, the differences in skeletal pattern were not the primary cause of its decrease, but a secondary result induced by the differences in occlusal contact area according to the facial pattern.

Complete denture fabricated by Jiro Abe's method for edentulous patient with severe alveolar ridge resorption: a case report (심한 치조제 흡수를 보이는 무치악 환자에서 Jiro Abe법에 의한 완전틀니 제작 증례)

  • Jun, Daejeon;Yang, Dong-Hun;Vang, Mongsook;Yang, Hongso;Park, Sangwon;Yun, Kwidug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.338-345
    • /
    • 2014
  • Fabrication of complete denture by Jiro Abe's method was introduced that enhance the retention and stability of denture by sealing around the denture border with mucous membrane to make negative pressure at the inner surface of denture base when swallowing or occlusion. In this case, taking impression and fabricating complete denture by the Jiro Abe's method for an edentulous patient with severe mandibular alveolar bone resorption allowed us to obtain clinically enhance stability of denture and improve satisfaction of patient.