• Title/Summary/Keyword: Occlusion pressure

Search Result 130, Processing Time 0.031 seconds

Effectiveness of clinical remounting improving balanced occlusion of complete dentures (총의치 균형교합에 영향을 미치는 진료실재부착의 효과)

  • Lee, Ye-Jin;Kim, Jong-Hoi;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.328-334
    • /
    • 2020
  • Clinical remounting of complete denture is performed to refine occlusal harmony in maxillo-mandibular relation. It has been reported that patients who used adjusted dentures with clinical remounting felt less complications such as pain and discomfort in mastication. The purpose of this study was to assess effects of clinical remounting with case series. Seven patients with existing complete prosthesis were included. Clinical remounting procedure was done through interocclusal relation recording. In addition, occlusal force was measured with pressure indicating sensor and occlusal contact areas were evaluated with photo occlusion analysis. Occlusal contact areas of prosthesis were enlarged, while bite pressure was not increased. Hit and slide phenomenon of prosthesis was reduced concurrently. Clinical remounting procedure improved denture stability and increased occlusal contact area. Therefore, clinical remounting should be considered.

Changes in occlusal force and occlusal contact area after orthodontic treatment (교정 치료 후 교합력, 교합면적의 변화)

  • Choi, Yoon-Jeong;Chung, Choo-Ryung J.;Kim, Kyung-Ho
    • The korean journal of orthodontics
    • /
    • v.40 no.3
    • /
    • pp.176-183
    • /
    • 2010
  • Objective: This study was performed to evaluate functional changes of occlusion after orthodontic treatment by measuring the occlusal force (OcFr) and occlusal contact area (OcAr), and to compare OcFr and OcAr change according to premolar extractions. Methods: Data were obtained from 74 patients who had finished orthodontic treatment using fixed appliance aged between 18 and 40 years. Subjects were divided into groups who had four premolars extractions or non-extraction (Male extraction-16, Male nonextraction-18, Female extraction-19, Female nonextraction-21). All subjects were asked to bite pressure-sensitive sheets into maximum intercuspation with maximum bite force, and OcFr and OcAr were evaluated by measuring the sheet with a CCD camera. Records were taken right after debonding, 1 week, 1 month, 3 months, 6 months and 1 year after debonding. Results: OcFr and OcAr increased gradually in all groups during the 1 year retention period (p < 0.05). Male groups showed higher OcFr and OcAr than female groups throughout the retention periods (p < 0.05). There were no statistically significant differences of OcFr and OcAr between extraction and non-extraction groups in both males and females (p > 0.05). Conclusions: Occlusion was improved functionally throughout the 1 year retention, and premolar extraction did not induce a decline in the functional aspect of occlusion.

Implementation and estimation of the noninvasive vesical pressure measurement system for diagnosis of lower urinary tract symptom (하부요로 폐색진단을 위한 비침습적 방광내압 계측 시스템의 구현 및 평가)

  • Jeong, Do-Un;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.139-147
    • /
    • 2006
  • Lower urinary tract symptoms (LUTS) affect self-assessed quality of life. The prevalence of LUTS is commonly high in the elderly. The purpose of urodynamic investigation is to obtain information on the function of the urinary system. One of the most frequently used measurement procedures in urodynamics is filling and voiding cystometry. But in this system transurethral catheter is used and it makes patients uncomfortable. The aim of this study is to implement the system that could evaluate noninvasively the function of urinary tract. A new system has been developed to analyze urine flow rate and vesical pressure during voiding. These signals were recorded simultaneously and transmitted to a PC. For system evaluation, a model for the lower urinary system of men was constructed. From the evaluation of the model, vesical pressure was correlated with the occlusion degree. In a pilot study with five male subjects, maximum of standard deviation was 1.26, error rate was 3.49 and coefficient of variation was 3.48.

Delayed-type retrobulbar hematoma caused by low temperature after reconstruction of inferior blow-out fracture

  • Lee, Da Woon;Kim, Tae Hyung;Choi, Hwan Jun;Wee, Syeo Young
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.2
    • /
    • pp.110-114
    • /
    • 2021
  • Retrobulbar hemorrhage is a disastrous condition that can lead to permanent blindness. As such, rapid diagnosis and treatment are critical. Here, we report a patient who presented with retrobulbar hemorrhage following an orbital floor fracture. Restoration of inferior orbital wall with porous polyethylene implant was underwent. Four days after the orbital floor reconstruction, the patient smoked a cigarette outdoors in -3℃ weather. Cold temperature and smoking caused an increase in his systemic blood pressure. The elevated blood pressure increased intraorbital pressure to the extent of causing central retinal artery occlusion and exacerbated oozing. During exploratory surgery, 3 mL of hematoma and diffuse oozing without arterial bleeding were observed. Prompt diagnosis and treatment prevented vision impairment. Few studies have reported on the risk factors for retrobulbar hemorrhage. This case showed that daily activities, such as exposure to cold weather or tobacco smoking, could be risk factors for retrobulbar hemorrhage.

Resuscitative Endovascular Balloon Occlusion of the Aorta in Impending Traumatic Arrest: Is It Effective?

  • Chung, Jae Sik;Kim, Oh Hyun;Kim, Seongyup;Jang, Ji Young;An, Gyo Jin;Jung, Pil Young
    • Journal of Trauma and Injury
    • /
    • v.33 no.1
    • /
    • pp.23-30
    • /
    • 2020
  • Purpose: Hemorrhagic shock is the leading cause of death in trauma patients worldwide. Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a technique used to improve the hemodynamic stability of patients with traumatic shock and to temporarily control arterial hemorrhage. However, further research is required to determine whether REBOA with cardiopulmonary resuscitation (CPR) in near-arrest or arrest trauma patients can help resuscitation. We analyzed trauma patients who underwent REBOA according to their CPR status and evaluated the effects of REBOA in arrest situations. Methods: This study was a retrospective single-regional trauma center study conducted at a tertiary medical institution from February 2017 to November 2019. We evaluated the mortality of severely injured patients who underwent REBOA and analyzed the factors that influenced the outcome. Patients were divided into CPR and non-CPR groups. Results: We reviewed 1,596 trauma patients with shock, of whom 23 patients underwent REBOA (1.4%). Two patients were excluded due to failure and a repeated attempt of REBOA. The Glasgow Coma Scale score was lower in the CPR group than in the non-CPR group (p=0.009). Blood pressure readings at the emergency room were lower in the CPR group than in the non-CPR group, including systolic blood pressure (p=0.012), diastolic blood pressure (p=0.002), and mean arterial pressure (p=0.008). In addition, the mortality rate was higher in the CPR group (100%) than in the non-CPR group (50%) (p=0.012). The overall mortality rate was 76.2%. Conclusions: Our study suggests that if REBOA is deemed necessary in a timely manner, it is better to perform REBOA before an arrest occurs. Therefore, appropriate protocols, including pre-hospital REBOA, should be constructed to demonstrate the effectiveness of REBOA in reducing mortality in arrest or impending arrest patients.

The Role of Pulmonary Capillary Pressure in the Oxygen Free Radical-Induced Acute Lung Injury (산소기에 의한 급성 폐손상에서 폐모세혈관압의 역할에 관한 연구)

  • Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.6
    • /
    • pp.474-483
    • /
    • 1992
  • Background: Regardless of its causes, acute lung injury is characterized pathophysiologically by increased pulmonary arterial pressure and the protein-rich edema. Many inflammatory mediators are known to be involved in the pathogenesis of acute lung injury, including oxygen free radicals (OFR). But the changes in pulmonary capillary pressure in the OFR-induced acute lung injury is not clear. While the pulmonary edema characterized by the movement of fluid and solutes is dependent on the pressure gradient and the alveolar-capillary permeability, the role of pulmonary capillary pressure in the development of pulmonary edema is also not well understood. Method: Male Sprague-Dawley rats were divided into 5 groups: normal control (n=5), xanthine/xanthine oxidase (X/XO)-treated group (n=7), catalase-pretreated group (n=5), papaverine-pretreated group (n=7), and indomethacin-pretreated group (n=5). In isolated perfused rat lungs, the sequential changes in pulmonary arterial pressure, pulmonary capillary pressure by double occlusion method, and lung weight as a parameter of pulmonary edema were determined. Results: Pulmonary arterial pressure and pulmonary capillary pressure were increased by X/XO. This increase was significantly attenuated by catalase and papaverine, but indomethacin did not prevent the X/XO-induced increase. Lung weight gain was also observed by X/XO perfusion. It was prevented by catalase. Papaverine did not completely block the increase, but significantly delayed the onset. Indomethacin had no effect on the increase in lung weight. Conclusion: These data suggest that increased pulmonary capillary pressure by OFR may aggravate pulmonary edema in the presence of increased alveolar-capillary permeability and this may not be mediated by cyclooxygenase metabolites.

  • PDF

Implementation and Evaluation of the LUTS Diagnosis System Using FPGA (FPGA를 이용한 LUTS 진단 시스템 구현 및 평가)

  • Jeong, Do-Un;Chung, Wan-Young;Jeon, Gye-Rock
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.1
    • /
    • pp.6-14
    • /
    • 2007
  • The purpose of urodynamic investigation is to determine information on the function of the urinary system. One of the most frequently used measurement procedures in urodynamics is filling and voiding cystometry using invasive method. But in this method transurethral catheter is use and it makes patients uncomfortable. The aim of this study was to implement the system that could evaluate the function of urinary tract with noninvasive and comfortable method. Therefor in this study, a sensor and measuring system were implemented to measure uroflow, urophonography and noninvasive bladder pressure signal during urination for diagnosing the LUTS(lower urinary tract symptoms) using noninvasive method. The implemented system compose of the sensor parts, signal conditioning parts, system control parts using FPGA and PC monitoring program. For the evaluation of the implemented system, the simulation of system's control part was performed and the model system for the lower urinary system was designed. From the evaluation of the model system, the mean error rate of the uroflow measurement part was 1.08% and coefficient of variation was 1,48. And the mean error rate of the noninvasive bladder pressure measurement part was 2.41% and coefficient of variation was 2.81. urophongraphy signal analysis was accomplished in a time domain and frequency domain. Average RMS power was used in a time domain analysis, and MF was used in a frequency domain analysis. From the evaluation of the model system average RMS power and MF was dependent on the occlusion degree significantly and median frequency range of $60{\sim}160Hz$ was correlated with the occlusion.

  • PDF

Cerebrospinal Fluid Lumbar Tapping Utilization for Suspected Ventriculoperitoneal Shunt Under-Drainage Malfunctions

  • Lee, Jong-Beom;Ahn, Ho-Young;Lee, Hong-Jae;Yang, Ji-Ho;Yi, Jin-Seok;Lee, Il-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • Objective : The diagnosis of shunt malfunction can be challenging since neuroimaging results are not always correlated with clinical outcomes. The purpose of this study was to evaluate the efficacy of a simple, minimally invasive cerebrospinal fluid (CSF) lumbar tapping test that predicts shunt under-drainage in hydrocephalus patients. Methods : We retrospectively reviewed the clinical and radiological features of 48 patients who underwent routine CSF lumbar tapping after ventriculoperitoneal shunt (VPS) operation using a programmable shunting device. We compared shunt valve opening pressure and CSF lumbar tapping pressure to check under-drainage. Results : The mean pressure difference between valve opening pressure and CSF lumbar tapping pressure of all patients were $2.21{\pm}24.57mmH_2O$. The frequency of CSF lumbar tapping was $2.06{\pm}1.26times$. Eighty five times lumbar tapping of 41 patients showed that their VPS function was normal which was consistent with clinical improvement and decreased ventricle size on computed tomography scan. The mean pressure difference in these patients was $-3.69{\pm}19.20mmH_2O$. The mean frequency of CSF lumbar tapping was $2.07{\pm}1.25times$. Fourteen cases of 10 patients revealed suspected VPS malfunction which were consistent with radiological results and clinical symptoms, defined as changes in ventricle size and no clinical improvement. The mean pressure difference was $38.07{\pm}23.58mmH_2O$. The mean frequency of CSF lumbar tapping was $1.44{\pm}1.01times$. Pressure difference greater than $35mmH_2O$ was shown in 2.35% of the normal VPS function group (2 of 85) whereas it was shown in 64.29% of the suspected VPS malfunction group (9 of 14). The difference was statistically significant (p=0.000001). Among 10 patients with under-drainage, 5 patients underwent shunt revision. The causes of the shunt malfunction included 3 cases of proximal occlusion and 2 cases of distal obstruction and valve malfunction. Conclusion : Under-drainage of CSF should be suspected if CSF lumbar tapping pressure is $35mmH_2O$ higher than the valve opening pressure and shunt malfunction evaluation or adjustment of the valve opening pressure should be made.

The methods for occlusal force measurement and their clinical applicatio (임상가를 위한 특집 3 - 교합력 측정의 방법과 임상적 적용)

  • Park, Ji-Man;Heo, Seong-Joo;Chun, Yoon-Sic
    • The Journal of the Korean dental association
    • /
    • v.50 no.1
    • /
    • pp.22-30
    • /
    • 2012
  • The methods for the occlusal force measurement have long been developed. The occlusal analyzing equipment utilizing the pressure-sensitive film (Prescale) is useful for the assessment and comparison among large group of patients. On the other hand, the apparatus which uses the grid-based sensor sheet (T-scan) can be a useful assistant for acquiring the well-balanced occlusion. The device that can process the electrical input from the strain gauge which is attached to the tooth surface can collect the dynamic data of actual masticatory force. This device has been developed for the measurement of actual mastication with the food bolus and it can be a useful method for the comparison before and after the restorative treatment. Occlusal force measurement can be applied for the analysis of therapeutic action, diagnosis of crack- tooth syndrome, temporomandibul ar disease, and idiopathic implant loosening.

Influence of Phellodendri Cortex Methanol Extract on the Responses of the Blood Pressure in the Rabbits and Cats (황백(黃柏) Methanol Extract의 가토(家兎) 및 가묘(家猫)의 혈압반응(血壓反應)에 미치는 영향(影響))

  • Lim, Dong-Yoon
    • Journal of Pharmaceutical Investigation
    • /
    • v.9 no.3
    • /
    • pp.27-38
    • /
    • 1979
  • This study was attempted to investigate the pharmacological action, especially depressor action of Phellodendri cortex and to elucidate the mechanism of its action, making use of Phellodendri cortex methanol extract (PCME) because its hypotensive action is not clear. Influence of PCME on the blood pressure of the rabbits and cats were observed in this study. PCME, when given intravenously in the rabbits and cats, elicited the hypotensive action, but intraventricular PCME in the rabbits did not show depressor action. Accumulation and tachyphylaxis by PCME administered into the ear-vein of the rabbits were not shown. Depressor effect of PCME in the rabbits was attenuated significantly by pretreatment with phentolamine, guanethidine, chorisondamine and atropine, but not by propranolol, diphenhydramine, cyproheptadine and vagotomization. The pressor activity of angiotensin was unimpaired after injection of maximal hypotensive doses (100mg/kg) of PCME, but the pressor activity of norepinephrine and carotid occlusion was abolished markedly. In addition, PCME given into jugular vein of the cats weakened norepinephrine pressor responses and caused the reversal of epinephrine pressor responses. These results suggest that the hypotensive action of PCME may be due to dual mechanisms by interference with peripheral sympathetic function, alpha adrenoceptor blocking action, and peripheral parasympathomimetics action, muscarinic action.

  • PDF