• Title/Summary/Keyword: Occlusal analysis

Search Result 451, Processing Time 0.028 seconds

Computerized occlusal analysis: correlation with occlusal indexes to assess the outcome of orthodontic treatment or the severity of malocculusion

  • Lee, Sang-Min;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.46 no.1
    • /
    • pp.27-35
    • /
    • 2016
  • Objective: The aims of our study were to verify the validity of the T-Scan III system (Tekscan) as an objective occlusal evaluation tool, and to assess the differences between two occlusal indexes - the peer assessment rating (PAR) index and the American Board of Orthodontics objective grading system (OGS) - by comparing the scores derived from the T-Scan III system with the two occlusal indexes and analyzing the correlations between them. Methods: The final study sample included 48 adult volunteers (39 men and 9 women, mean age $24.14{\pm}3.16years$), after excluding 29 volunteers whose occlusion could not be evaluated by the T-Scan III system due to severe skeletal or occlusal problems. PAR index and OGS scores were assessed using dental study models, and measurements of centric occlusion, protrusive movement, and lateral excursion movement were obtained via the T-Scan III system. The results were analyzed to determine correlations. Results: Occlusal analysis by the T-Scan III system was clinically reliable (p < 0.05), and the PAR index and OGS scores were significantly correlated with several measurements obtained with the T-Scan III system (p < 0.05). Conclusions: The T-Scan III system is a quantitative and reliable method for occlusal evaluation, and represents a potential substitute for occlusal indexes. Compared to the PAR index, the OGS scores of more variables were significantly correlated with the T-Scan measurements.

An Analysis of Duration of Occlusal Sounds in TMD Patients (측두하악장애 화낮의 교합음 지속시간에 관한 분석)

  • Young-Mee Kwon;Jae-Kap Choi
    • Journal of Oral Medicine and Pain
    • /
    • v.14 no.1
    • /
    • pp.9-17
    • /
    • 1989
  • The author has measured the duration of occlusal sounds during centric occlusal tapping in 30 patients with TMD and 30 normal subjects as controls, and then correlated the duration of occlusal sounds with CMI, amount of centric slide, midline deviation, habitual side of mastication, and presence of occlusal interference. The results were as follows 1. The duration of occlusal sounds during centric occlusal tapping were 36.26 msec in TMD patients and 22.8 msec in normal subjects (p<0.01). 2. The correlation between duration of occlusal sounds and CMI was significant (p<0.01). 3. The correlations between duration of occlusal sounds with amount of centric slide, midline deviation, habitual side of mastication, and presence of occlusal interference were not significant (p<0.05).

  • PDF

Evaluation of occlusal strength using T-Scan Novus and Dental prescale II in dental prosthodontic treatments: A case report (보철물 수복 형태에 따른 T-Scan Novus와 Dental prescale II를 이용한 교합력 평가 활용 증례)

  • Su-Hyun Choi;Yu-Sung Choi;Jong-Hyuk Lee;Seung-Ryong Ha
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.160-178
    • /
    • 2023
  • Diagnosis and analysis of occlusal relationships are important factors in prosthetic treatment. A thorough occlusion analysis and evaluation should be performed before treatment to restore a stable interocclusal relationship. Analysis and evaluation are essential during the treatment process and at regular follow-ups. Recently, with the development of dental equipment and digital processing methods, new quantitative analysis methods that can record the patient's occlusal relationship have been introduced. Among them, the T-Scan Novus (Tekscan Inc., S. Boston, MA, USA) displays the strength of the initial contact point and the occlusal contact point of the teeth using a pressure sensor. With this, occlusal contact time of the teeth, anteroposterior and left-right balance of occlusal force can be compared. The Dental prescale II (GC Co., Tokyo, Japan) scans the occlusal contact point using a pressure-sensing film and analyzes the density of the contact point. It can measure the distribution and strength of the occlusal force of the teeth in the most natural occlusion state. Based on this, appropriate prosthetic treatment (four-unit fixed partial denture, removable partial denture, complete denture, and complete oral restoration cases) was performed according to the area and extent of the patient's tooth loss. The patient's occlusion at the first visit, treatment stage, right after treatment, and regular follow-up were compared and evaluated using a quantitative method for appropriate occlusion analysis using T-Scan Novus and Dental prescale II. This report enhances the understanding of occlusion analysis during prosthetic restoration. The results satisfied both the clinician and patients in terms of function and aesthetics.

A STUDY ON OCCLUSAL CONTACT USING COMPUTERIZED OCCLUSAL ANALYSIS SYSTEM (Computerized Occlusal Analysis System을 이용한 Occlusal Contact에 관한 연구)

  • 연태호;김영구
    • Journal of Oral Medicine and Pain
    • /
    • v.14 no.1
    • /
    • pp.81-88
    • /
    • 1989
  • 저자는 정상 치열을 가지며 두개하악장애의 증상 및 병력이 없는 성인 21명을 대상으로 computerized occlusal analysis system인 T-Scan system을 이용하여 교합력에 따른 치아접촉수와 총치아접촉시간을 측정한 후 정량적인 분석을 시도하여 다음과 같은 결론을 얻었다. 1. 최대 측두근 전부 근활성도의 약 20%, 50%, 80% 수준의 교합력에서 치아접촉수의 평균은 각각 1.6개, 8.8개, 16.7개로 교합력이 증가할수록 유의하게 증가하였다. 2. 최대 측두근 전부 근활성도의 약 20%, 50%, 80% 수준의 교합력에서 치아당 치아접촉수이 평균은 대구치에서는 0.2, 1.4, 2.2 개였으며 소구치에서는 0.1, 0.5, 1.1개였고, 전치에서는 0.1, 0.2, 0.6개로 교합력이 증가함에 따라 유의하게 증가하였다. 3. 치아접촉분포로 구분된 대칭군과 비대칭군간의 총치아접촉시간에는 유의한 차이가 없었다.

  • PDF

Comparison of two computerized occlusal analysis systems for indicating occlusal contacts

  • Jeong, Min-Young;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.49-54
    • /
    • 2020
  • PURPOSE. The purpose of this study was to compare the performance of Accura to that of the T-scan for indicating occlusal contacts. MATERIALS AND METHODS. Twenty-four subjects were selected. Their maxillary dental casts were scanned with a model scanner. The Stereolithography files of the casts were positioned to align with the occlusal plane. Occlusal surfaces of every tooth were divided into three to six anatomic regions. T-scan and Accura recordings were made during two masticatory cycles. The T-scan and Accura images were captured at the maximum bite force and overlapped to the cast. Photographs of interocclusal records were used as the reference during overlap. The occlusal contacts were counted to compare the T-scan and Accura. McNemar's test was used for statistical significance and the corresponding P-values were calculated from a chi-square distribution with one degree of freedom. The accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of Accura were calculated relative to the T-scan values as a control. RESULTS. No statistical differences (P>.05) were found between the T-scan and Accura methods. The accuracy of Accura was 75.8%, sensitivity was 82.1%, specificity was 60.1%, PPV was 82.9%, and NPV was 60.1%. CONCLUSION. Accura could be another possible option as a computerized occlusal analysis system for indicating occlusal contacts at maximum intercuspation.

Relationship between articulation paper mark size and percentage of force measured with computerized occlusal analysis

  • Qadeer, Sarah;Kerstein, Robert;Kim, Ryan Jin-Yung;Huh, Jung-Bo;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.1
    • /
    • pp.7-12
    • /
    • 2012
  • PURPOSE. Articulation paper mark size is widely accepted as an indicator of forceful tooth contacts. However, mark size is indicative of contact location and surface area only, and does not quantify occlusal force. The purpose of this study is to determine if a relationship exists between the size of paper marks and the percentage of force applied to the same tooth. MATERIALS AND METHODS. Thirty dentate female subjects intercuspated into articulation paper strips to mark occlusal contacts on their maxillary posterior teeth, followed by taking photographs. Then each subject made a multi-bite digital occlusal force percentage recording. The surface area of the largest and darkest articulation paper mark (n = 240 marks) in each quadrant (n = 60 quadrants) was calculated in photographic pixels, and compared with the force percentage present on the same tooth. RESULTS. Regression analysis shows a bi-variant fit of force % on tooth (P<.05). The correlation coefficient between the mark area and the percentage of force indicated a low positive correlation. The coefficient of determination showed a low causative relationship between mark area and force ($r^2$ = 0.067). The largest paper mark in each quadrant was matched with the most forceful tooth in that same quadrant only 38.3% of time. Only 6 2/3% of mark surface area could be explained by applied occlusal force, while most of the mark area results from other factors unrelated to the applied occlusal force. CONCLUSION. The findings of this study indicate that size of articulation paper mark is an unreliable indicator of applied occlusal force, to guide treatment occlusal adjustments.

Changes of bite force and dynamic functional occlusion analysis after occlusal stabilization splint therapy in sleep bruxism patients: a pilot study (수면이갈이 환자에서 교합안정장치 사용 후 교합력 및 동기능적교합분석: 예비 연구)

  • Jaeyeon, Kim;Yiseul, Choi;Yool Bin, Song;Wonse, Park;Seong Taek, Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.204-212
    • /
    • 2022
  • Purpose: The aim of this study was to compare changes of bite force, occlusal contact area, and dynamic functional occlusion analysis after occlusal stabilization splint therapy during sleep for one month in a patient with bruxism. Materials and Methods: From October 2021 to July 2022, sleep bruxism of 30 patients who visited the Department of Oral Medicine at Yonsei University College of Dentistry Hospital were recruited. The participants were divided into two groups: using an occlusal stabilization splint during sleep (treatment; n = 15) and not using an occlusal stabilization splint (control; n = 15). Before using the occlusal stabilization splint and one month after, bite force, occlusal contact area and dynamic functional occlusion analysis (ratio of left/right bite forces, average bite forces, maximum bite forces, and maximum contact areas during lateral and anterior and posterior mandibular movements) were performed. Results: There was no difference in bite force and occlusal contact area between the treatment group using the occlusal stabilization splint and the control group not using the occlusal stabilization splint during sleep for one month. However, there were significant differences in the average bite force and maximum bite force in the lateral and anterior and posterior mandibular movements and the maximum contact areas in the anterior and posterior mandibular movements. Conclusion: The occlusal stabilization splint is helpful for sleep bruxism patients who lateral and anterior and posterior mandibular movements. In addition, further studies are needed a double-blind study with a large population.

A STUDY ON THE OCCLUSAL PLANE INCLINATION IN LATERAL CEPHALOGRAPH (교합평면 경사도에 관한 두부방사선학적 연구)

  • Lee, Sung-Youn;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.21 no.2 s.34
    • /
    • pp.367-397
    • /
    • 1991
  • This study was aimed to investigate the occlusal plane inclination in relation to the skeletal and dental assessment measurements in order to provide a reference in orthodontic treatment planning as the occlusal plane should be reconstructed orthodontically or gnathologically. The sample consisted of 73 normal occlusions and 113 malocclusions of adults. The computerized statistical analysis of 38 occlusal plane's and 29 skeletal and dental measurements were carried out with SPSS. The conclusions were as follows; 1 In normal occlusion, COP-NaPog was average $83.63^{\circ}$ (2.44) and occlusal plane inclination had a strong negative correlation with SNB and FH-NaPog. 2. In normal occlusion, ArANS plane was nearly parallel to the occlusal plane. 3. In malocclusion, the larger the mandibular plane angle and the shorter the ramus height was, the more downward the occlusal plane had a tendency to tip anteriorly. 4. Occlusal plane was more horizontal in deep bite group, while it was steeper in openbite group. 5. The curve of Spee was severe in deep bite group but in openbite group mandibular occlusal plane showed average reverse curvature, where it was found that the configuration of the occlusal plane contributed to the excess or deficiency of anterior overbite.

  • PDF

Computerized analysis of occlusal contacts in bruxism patients treated with occlusal splint therapy

  • Gumus, Hasan Onder;Kilinc, Halil Ibrahim;Tuna, Suleyman Hakan;Ozcan, Nihal
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.256-261
    • /
    • 2013
  • PURPOSE. Occlusal splints are commonly used to prevent tooth wear caused by bruxism. However, the effects of splints on occlusion are still unclear. Although it is rarely alluded in literature, splints can provoke severe occlusal alterations and other complications. This study was aimed to identify differences in the responses of individuals with bruxism and healthy individuals to a full-arch maxillary stabilization splint in terms of occlusal changes. MATERIALS AND METHODS. Occlusal contacts in 20 (5 male, 15 female) bruxism patients and 20 (5 male, 15 female) controls with normal occlusion were evaluated before and after occlusal splint therapy. T-Scan III, a computerized occlusal analysis system, was used to simultaneously measure occlusion and disclusion times as well as left-right and anterior-posterior contact distributions before splint therapy and 3 months after therapy. Wilcoxon and Mann-Whitney U tests were used for statistical analyses (${\alpha}$=.05). RESULTS. No differences were found in the posterior contact of bruxism patients before and after stabilization splint treatment. However, differences in posterior contact were observed between bruxists and normal individuals prior to treatment, and this difference disappeared following treatment. CONCLUSION. The results of this study showed the use of a stabilization splint may not have an effect on occlusion. However, the area of posterior occlusal contact among bruxists was found to be greater than that of normal individuals. According to this study, the clinical use of splints may be harmless.

A STUDY ON THE OCCLUSAL CONTACT OF THE SUBJECTS WITH TEMPOROMANDIBULAR JOINT SOUND (측두악관절 잡음자의 교합접촉에 관한 연구)

  • Yoon, Kwang-Hyun;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.1
    • /
    • pp.51-61
    • /
    • 1993
  • The purpose of this study was to evaluate a possible occlusal contributing factor on the pathogenesis of temporomandibular joint sound by a new computer aided method for analysis of occlusal contact. 20 subjects without temporomandibular joint sound as control group and 20 subjects with temporomandibular joint sound as experimental group in the TMJ clinic, dental infirmary, School of Dentistry, Chosun University were selected so as to investigate the distribution and intensity of the bilateral occlusal contacts on silicone rubber bites in habitual intercusal position through a computer aided system. The following results were obtained : 1. The distribution and intensity of the occlusal contact could be analyzed and expressed as color density value per levels by this computer aided method. 2. There was not statistical significance between control and experimental group in total occlusal contacts. 3. There was statistical significance between control and experimental group In the total difference of right and left occlusal contacts.(P<0.05).

  • PDF