• Title/Summary/Keyword: Observers

Search Result 644, Processing Time 0.026 seconds

Coincidence of calcified carotid atheromatous plaque, osteoporosis, and periodontal bone loss in dental panoramic radiographs

  • Ramesh, Aruna;Soroushian, Sheila;Ganguly, Rumpa
    • Imaging Science in Dentistry
    • /
    • v.43 no.4
    • /
    • pp.235-243
    • /
    • 2013
  • Purpose: This study was performed to assess the correlation of calcified carotid atheromatous plaque (CCAP), the mandibular cortical index, and periodontal bone loss in panoramic radiographs. Materials and Methods: One hundred eighty-five panoramic radiographs with CCAP and 234 without this finding were evaluated by 3 observers for the presence of osseous changes related to osteoporosis and periodontal bone loss. Chi-squared and Mann-Whitney U tests were used to compare the two groups for an association of CCAP with the mandibular cortical index and periodontal bone loss, respectively. Results: There was a statistically significant coincidence of CCAP and osseous changes related to osteopenia/osteoporosis, with a p-value <0.001. There was no statistically significant coincidence of CCAP and periodontal bone loss. When comparing the 2 groups, "With CCAP" and "Without CCAP", there was a statistically significant association with the mean body mass index (BMI), number of remaining teeth, positive history of diabetes mellitus, and vascular accidents. There was no statistically significant association with gender or a history of smoking. Conclusion: This study identified a possible concurrence of CCAP and mandibular cortical changes secondary to osteopenia/osteoporosis in panoramic radiographs. This could demonstrate the important role of dental professionals in screening for these systemic conditions, leading to timely and appropriate referrals resulting in early interventions and thus improving overall health.

Anatomy and morphology of the nasopalatine canal using cone-beam computed tomography

  • Thakur, Arpita Rai;Burde, Krishna;Guttal, Kruthika;Naikmasur, Venkatesh G.
    • Imaging Science in Dentistry
    • /
    • v.43 no.4
    • /
    • pp.273-281
    • /
    • 2013
  • Purpose: This study was performed to evaluate the general anatomy and morphology of the nasopalatine canal using cone-beam computed tomography (CBCT) and to determine the human anatomic variability of the nasopalatine canal in relation to age and gender. Materials and Methods: The study included 100 subjects aged between 20 and 86 years who were divided into the following 3 groups: 1) 20-34 years old; 2) 35-49 years old; 3) ${\geq}50$ years old. The subjects were equally distributed between the genders. CBCT was performed using a standard exposure and patient positioning protocol. The data of the CBCT images were sliced in three dimensions. Image planes on the three axes (X, Y, and Z) were sequentially analyzed for the location, morphology and dimensions of the nasopalatine canal by two independent observers. The correlation of age and gender with all the variables was evaluated. Results: The present study did not reveal statistically significant differences in the number of openings at the nasal fossa; diameter of the nasal fossa openings; diameter of the incisive fossa; shape, curvature, and angulation of the canal as viewed in the sagittal sections; antero-posterior dimensions and length of the canal in the sagittal sections; or the level of division of the canal in the coronal plane by age. However, males and females showed significant differences in the length of the canal in the sagittal sections and level of the division of the canal in the coronal plane. Conclusion: The present study highlighted important variability observed in the anatomy and morphology of the nasopalatine canal.

Interobserver Reliabilities of Modified Barthel Index, and Motor Assessment Scale in Stroke Patients (Modified Barthel Index 및 Motor Assessment Scale을 이용한 검사자간의 신뢰도 검사)

  • Ko, Seong-Gyu;Kim, Chun-Bae
    • The Journal of Korean Medicine
    • /
    • v.20 no.1 s.37
    • /
    • pp.60-65
    • /
    • 1999
  • We have conducted a study of the interobserver reliabilities of Modified Barthel Index and Motor Assessment Scale with 30 patients hospitalized with strokes in the department of circulatory internal medicine, Sang Ji University Oriental Hospital. The observations were performed by two staff and residents in the circulatory internal medicine department. Raters were assigned in random pairs to individual patients. Evaluations were performed independently by the two observers. In order to minimize the impact of fluctuations in the patients' clinical status, the second set of observations immediately followed the first. Each patient was used for only one pair of evaluations. The results were as follows. 1. Mean kappa value of 13 items in Modified Barthel Index(MBD was 0.742, which indicated excellent interobserver reliability. The kappa values indicated almost $perfect({\kappa}:\;0.81-1.00)$ for 4, substantial for $9({\kappa}:\;0.61-0.80)$, and moderate for $2({\kappa}:\;0.41-0.60)$ of 13 items. All items. except Grooming item, showed statistically significant interobserver agreement(p<0.01) 2. Mean kappa value of 8 items. except General tonus, in Motor Assessment Scale(MAS) was 0.823, which indicated excellent interobserver reliability. and this value of Motor Assessment Scale was more high than MBI' s value. 0.81. The kappa values indicated almost perfect for 5, substantial for 3 of 8 items. All items showed statistically significant interobserver agreement(P<0.01).

  • PDF

Facial profile parameters and their relative influence on bilabial prominence and the perceptions of facial profile attractiveness: A novel approach

  • Denize, Erin Stewart;McDonald, Fraser;Sherriff, Martyn;Naini, Farhad B.
    • The korean journal of orthodontics
    • /
    • v.44 no.4
    • /
    • pp.184-194
    • /
    • 2014
  • Objective: To evaluate the relative importance of bilabial prominence in relation to other facial profile parameters in a normal population. Methods: Profile stimulus images of 38 individuals (28 female and 10 male; ages 19-25 years) were shown to an unrelated group of first-year students (n = 42; ages 18-24 years). The images were individually viewed on a 17-inch monitor. The observers received standardized instructions before viewing. A six-question questionnaire was completed using a Likert-type scale. The responses were analyzed by ordered logistic regression to identify associations between profile characteristics and observer preferences. The Bayesian Information Criterion was used to select variables that explained observer preferences most accurately. Results: Nasal, bilabial, and chin prominences; the nasofrontal angle; and lip curls had the greatest effect on overall profile attractiveness perceptions. The lip-chin-throat angle and upper lip curl had the greatest effect on forehead prominence perceptions. The bilabial prominence, nasolabial angle (particularly the lower component), and mentolabial angle had the greatest effect on nasal prominence perceptions. The bilabial prominence, nasolabial angle, chin prominence, and submental length had the greatest effect on lip prominence perceptions. The bilabial prominence, nasolabial angle, mentolabial angle, and submental length had the greatest effect on chin prominence perceptions. Conclusions: More prominent lips, within normal limits, may be considered more attractive in the profile view. Profile parameters have a greater influence on their neighboring aesthetic units but indirectly influence related profile parameters, endorsing the importance of achieving an aesthetic balance between relative prominences of all aesthetic units of the facial profile.

Characterization and Color Reproduction Based on Average Picture Level if PDP Displays (평균화면밝기에 기반한 PDP 디스플레이의 특성화 및 색 재현)

  • Kwon, Oh-Seol;Ko, Kyung-Woo;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.5
    • /
    • pp.9-17
    • /
    • 2008
  • This paper proposes a method of color reproduction considering the viewing conditions of a PDP TV. Because of a change of peripheral environments by a temporal and spatial location of observers, the ambient lightings should be considered in the process of color reproduction of displays. A conventional method enhances the contrast and saturation of images by controlling voltage gains in each channel, so that there is a limit to implementing the phenomenon of human adaptation. This method also faces difficulties in reproducing the perceived colors under a variety of viewing conditions. Accordingly, in order to solve this problem, we first characterize the device by considering the brightness and the flare effect. The chromatic adaptation is finally applied to reproduce colors in a PDP TV using the information from the viewing conditions by the sensor. The images reproduced by the proposed method are visually more superior to those reproduced by a conventional method in the experiments.

Change of Reliability for Distal Metatarsal Articular Angle Measurement before and after Proximal Chevron Osteotomy (근위 갈매기 절골술 시행 전과 후의 원위 중족골 관절면각의 측정에 대한 신뢰성의 변화)

  • Park, Chul Hyun;Lee, Dong Yeol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.20 no.4
    • /
    • pp.145-151
    • /
    • 2016
  • Purpose: To evaluate the reliability of preoperative and postoperative distal metatarsal articular angle (DMAA) measurements and to determine whether such reliability is different in accordance with the foot and ankle fellowship and the number of years in practice. Materials and Methods: Between July 2012 and June 2014, a total of 20 patients (24 feet) were treated with proximal chevron osteotomy and distal soft tissue procedure for symptomatic hallux valgus deformity. DMAA were measured twice with an interval of two weeks between the preoperative and postoperative dorsoplantar radiographs by four observers; two of whom were foot and ankle surgeons (A and B), one knee surgeon, and one senior resident. The intraobserver reproducibility and interobserver reliability were assessed by intraclass correlation coefficients. Moreover, the limit of agreement between the preoperative and postoperative DMAA measurements were assessed using a Bland-Altman plot. Results: The intraobserver reproducibility of the foot and ankle surgeon A, knee surgeon, and senior resident improved from 0.796, 0.575, and 0.586 preoperatively to 0.968, 0.864, and 0.864 postoperatively, respectively. The interobserver reliability of foot and ankle surgeon A-B, foot and ankle surgeon A-knee surgeon, and foot and ankle surgeon A-senior resident improved from 0.874, 0.688, and 0.677 preoperatively to 0.971, 0.917, and 0.838 postoperatively, respectively. Conclusion: The intra- and interobserver reliabilities for DMAA measurement improved after proximal chevron osteotomy. Therefore, the necessity of additional procedures to correct the increased DMAA should be reevaluated after proximal chevron osteotomy in the hallux valgus with an increased DMAA.

Comparision of two cephalometric superimposition methods - Nasion-sella line method and Anterior cranial base method (두가지 두부 방사선 사진 중첩 방법의 비교 - Nasion-Sella line 중첩과 Anterior cranial base 중첩)

  • Kyung, Seung-Hyun;Moon, Yon-Sik
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.633-641
    • /
    • 1997
  • Spatial change of craniofacial structures from growth or orthopedic force is usually evaluated by cephalometric superimpositions at different points in time.As the evaluation cu be changed according to cephalometric superimposition method,selettion for correct superimposition method is very important.Double registration of nineteen pairs of female lateral head films,their growth period is average 3.7 years and age is overage 10.7 years,were performed by two observers.Comparisions was made between two methods and the results revealed the following, 1. NS line and ACB superimpositions ate not markedly different in reliability due to almost same registration error of them. 2. The investigation was undertaken to examine interobserver difference.In NS line method, there is no significance in all measurements. In ACB method,significant difference was revealed in 4 measurements of 7 measurements was 3. In the investigation of intermethod difference, there is no significance between NS line and ACB superimpositions

  • PDF

The reproducibility of ultrasonographic assessment of local cross-sectional dimensions of masseter muscle (초음파를 이용한 교근의 단면두께 측정의 재현성에 대한 연구)

  • Chung Gi-Chung;Han Won-Jeong;Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.35 no.2
    • /
    • pp.97-103
    • /
    • 2005
  • Purpose : To determine if ultrasonography is a reliable technique to assess masseter muscle sites within intra- and interobserver and the scanning level and/or the muscle condition affect local cross-sectional dismension (LCSD) measurements of masseter muscle. Materials and Methods : 10 subjects without sign and symptom of temporomandibular disorders and missing posterior teeth were examined by ultrasonography. Bilateral ultrasonographic examinations were performed with a linear (B-scan) 7.5 MHz small-part transducer to register LCSDS of the masseter muscle on three different levels. Scans were made on relaxed and clenching condition. Three oral and maxillofacial radiologists measured at two sessions with a time interval of at least 5 minutes. Results : Variables such as 'condition' and 'level' had a significant effect on muscle measurements (p<0.05). There was no significant difference between 'sessions'(p>0.05) and 'observers' (p>0.05). LCSDS on lower scan level were significantly thinner than those on upper and middle level. Those on clenching condition were significantly thicker than those on relaxed condition (p<0.05). The scanning level with the highest reproducibility was middle with clenching condition (ICC=0.90, $MSE=0.55\%$). Conclusion : The data suggested that ultrasonography was a reliable method for measuring LSCD of masseter muscle in intra- and Interobserver and middle scan level showed the most reliable data.

  • PDF

Assessment of endodontically treated teeth by using different radiographic methods: an ex vivo comparison between CBCT and other radiographic techniques

  • Demiralp, Kemal Ozgur;Kamburoglu, Kivanc;Gungor, Kahraman;Yuksel, Selcen;Demiralp, Gokcen;Ucok, Ozlem
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.129-137
    • /
    • 2012
  • Purpose: To compare different radiographic methods for assessing endodontically treated teeth. Materials and Methods: Root canal treatments were applied in 120 extracted mandibular teeth, which were divided into four groups: (1) ideal root canal treatment (60 teeth), (2) insufficient lateral condensation (20 teeth), (3) root canals filled short of the apex (20 teeth), (4) overfilled root canal treatment (20 teeth). The teeth were imaged using intraoral film, panoramic film, digital intraoral systems (CCD and PSP), CCD obtained with portable X-ray source, digital panoramic, and CBCT images obtained at 0.3 $mm^3$ and 0.2 $mm^3$ voxel size. Images were evaluated separately by three observers, twice. Kappa coefficients were calculated. The percentage of correct readings obtained from each modality was calculated and compared using a t-test (p<0.05). Results: The intra-observer kappa for each observer ranged between 0.327 and 0.849. The inter-observer kappa for each observer for both readings ranged between 0.312 and 0.749. For the ideal root canal treatment group, CBCT with 0.2 $mm^3$ voxel images revealed the best results. For insufficient lateral condensation, the best readings were found with periapical film followed by CCD and PSP. The assessment of teeth with root canals filled short of the apex showed the highest percentage of correct readings by CBCT and CCD. For the overfilled canal treatment group, PSP images and conventional periapical film radiographs had the best scores. Conclusion: CBCT was found to be successful in the assessment of teeth with ideal root canal treatment and teeth with canals filled short of the apex.

Women's Ready -to-Wear Dresses in Korea(I) (여자 기성복에 관한 연구(I)-봄철 One-piece Dress를 중심으로-)

  • 현순옥
    • Journal of the Korean Home Economics Association
    • /
    • v.17 no.3
    • /
    • pp.13-21
    • /
    • 1979
  • The purpose of this study were : (1) to analyze the commercial sizes in Korea , (2) to investigate the designs and materials of one-piece dresses, and (3) to ascertain the prices and tendency to sale of dresses. A questionaire and the interviews with some producers were used for this study. The questionaire was made with many items after the pretest. For the statistical analysis, 99 dresses were used among 141 dresses which were examined. The observation of ten observers was made in markets(group A), department stores (group B), and commercial agents of manufacture (group C). The period of observation was from April 10 to May 4 , 1979. The results of this study indicated that : (1) According to makers , the commercial sizes in Korea were different. The sizes were based on only waist in group A , body measurements in group B, and either of them in group C. (2) In dress style, the box dresses were popular in three groups. (3) The type of sleeve in group A, B and C showed in following order : set in sleeve > dropped shoulder > raglan sleeve. (4) The most necklines were finished with collars. The shirtwaist collars were popular in group A and C and the flat collars in group C. (5) In dress material , cotton/polyester was popular in group A, wool in group B, and silk in group C. The use of natural fiber and color in three groups decreased in following order : C>B>A. (6) The prices of dresses were from 10,000 to 35,000 won in group A, form 23,8000 to 49, 800 won in group B, and from 12,500 to 90,000 won in group C. (7) In case of group C, the elements which had influence on sale were color, design, and price.

  • PDF