• Title/Summary/Keyword: Observer-based

Search Result 1,103, Processing Time 0.025 seconds

A Systemic Review of Positive Behavior Support Intervention Studies on Problem Behaviors of Children With Autism Spectrum Disorders: Focusing on Korean Single-Subject Research Design (자폐스펙트럼장애 아동의 문제행동에 대한 긍정적 행동지원 중재 연구의 체계적 고찰: 단일대상연구 설계를 중심으로)

  • Yoo, Yung-Mee;Choi, Yoo-Im
    • Therapeutic Science for Rehabilitation
    • /
    • v.10 no.4
    • /
    • pp.7-24
    • /
    • 2021
  • Objective : This study examined the characteristics of the literature involving a single-subject research design among positive behavior support intervention studies to improve problem behavior in children with autism spectrum disorders and assess the quality level. Methods : This is a literature study, and the targets of analysis were nine single-subject research papers published between 2011 and 2020. The subject papers were analyzed by dividing them into general characteristics and the qualitative levels according to the content of the research method. Results : Analysis of analyzing the contents of the study showed that the subjects were preschool and elementary school-age children at the same ratio. Furthermore, the study design involved mostly the middle and multiple baseline designs among the behaviors. All papers presented social validity, intervention fidelity, and observer reliability. Problem behaviors included self-injury and aggression behaviors, disturbing behaviors, and seat break-away behaviors, while the most dependent variables were measured through partial interval recording. As a result of confirming the intervention effect, the effect was confirmed in intervention, maintenance, and generalization. All analysis studies showed high-quality levels. Conclusion : This study confirmed the content and qualitative level of the thesis that applied the single-subject research design among positive behavior support intervention studies for problem behaviors of children with autism spectrum disorders. Positive behavior support intervention, an evidence-based intervention for children with autism spectrum disorders, was confirmed an effective intervention for autism spectrum disorders.

Interpretation of Complete Tumor Response on MRI Following Chemoradiotherapy of Rectal Cancer: Inter-Reader Agreement and Associated Factors in Multi-Center Clinical Practice

  • Hae Young Kim;Seung Hyun Cho;Jong Keon Jang;Bohyun Kim;Chul-min Lee;Joon Seok Lim;Sung Kyoung Moon;Soon Nam Oh;Nieun Seo;Seong Ho Park
    • Korean Journal of Radiology
    • /
    • v.25 no.4
    • /
    • pp.351-362
    • /
    • 2024
  • Objective: To measure inter-reader agreement and identify associated factors in interpreting complete response (CR) on magnetic resonance imaging (MRI) following chemoradiotherapy (CRT) for rectal cancer. Materials and Methods: This retrospective study involved 10 readers from seven hospitals with experience of 80-10210 cases, and 149 patients who underwent surgery after CRT for rectal cancer. Using MRI-based tumor regression grading (mrTRG) and methods employed in daily practice, the readers independently assessed mrTRG, CR on T2-weighted images (T2WI) denoted as mrCRT2W, and CR on all images including diffusion-weighted images (DWI) denoted as mrCRoverall. The readers described their interpretation patterns and how they utilized DWI. Inter-reader agreement was measured using multi-rater kappa, and associated factors were analyzed using multivariable regression. Correlation between sensitivity and specificity of each reader was analyzed using Spearman coefficient. Results: The mrCRT2W and mrCRoverall rates varied widely among the readers, ranging 18.8%-40.3% and 18.1%-34.9%, respectively. Nine readers used DWI as a supplement sequence, which modified interpretations on T2WI in 2.7% of cases (36/1341 [149 patients × 9 readers]) and mostly (33/36) changed mrCRT2W to non-mrCRoverall. The kappa values for mrTRG, mrCRT2W, and mrCRoverall were 0.56 (95% confidence interval: 0.49, 0.62), 0.55 (0.52, 0.57), and 0.54 (0.51, 0.57), respectively. No use of rectal gel, larger initial tumor size, and higher initial cT stage exhibited significant association with a higher interreader agreement for assessing mrCRoverall (P ≤ 0.042). Strong negative correlations were observed between the sensitivity and specificity of individual readers (coefficient, -0.718 to -0.963; P ≤ 0.019). Conclusion: Inter-reader agreement was moderate for assessing CR on post-CRT MRI. Readers' varying standards on MRI interpretation (i.e., threshold effect), along with the use of rectal gel, initial tumor size, and initial cT stage, were significant factors associated with inter-reader agreement.

Body Images of Korean College Students: Based on a Cross-National Study Focusing on Korean, Chinese, and Japanese College Students. (한국 대학생의 신체이미지: 일본, 중국과의 비교를 토대로)

  • Wan-Suk Gim;Yeon-Jae Ryu
    • Korean Journal of Culture and Social Issue
    • /
    • v.18 no.2
    • /
    • pp.301-327
    • /
    • 2012
  • This study investigated body images based on the survey data drawn from college students in three East Asian countries(Korea, Japan, and China). 347 Korean, 341 Chinese, and 271 Japanese college students responded to questions designed to measure body images such as body-related values (operability, inclination, locus of evaluation, and instrumentality of appearance), body esteem (appearance, and health), and objectified body-consciousness ( surveillance and shame). The results showed that body images differ among countries. Regarding body-related values, Korean students have least conservative beliefs and followed by Japanese, and Chinese. Korean students showed the highest acceptance level for the voluntary body alteration(operability), highest inclination to body appearance over health. They also showed the strongest tendency of evaluating their body from the observer's point of view and the strongest belief about the social utility of body appearance compare to Japanese and Chinese students. Appearance- esteem of Korean was similar to Chinese but higher than Japanese. Surveillance and shame about body appearance of Korean students were similar to Japanese but higher than Chinese. Compare to male students, females showed stronger belief about the body appearance over health, lower appearance esteem, and higher surveillance and shame about body. Korean women showed the least conservative body-related values, and the levels of body appearance esteem and objectified body consciousness were located in between Japanese and Chinese women. Japanese women showed especially low body appearance esteem and highest surveillance and shame. Chinese women showed the most conservative body-related value, the highest appearance-esteem, and the lowest surveillance and shame. It was revealed that the body-related values indirectly affect to appearance-esteem through the mediating role of objectified body consciousness in Chinese and Japanese samples, but that the body-related values had direct effect on appearance-esteem as well in Korean sample.

  • PDF

Semi-Quantitative Scoring of Late Gadolinium Enhancement of the Left Ventricle in Patients with Ischemic Cardiomyopathy: Improving Interobserver Reliability and Agreement Using Consensus Guidance from the Asian Society of Cardiovascular Imaging-Practical Tutorial (ASCI-PT) 2020

  • Cherry Kim;Chul Hwan Park;Do Yeon Kim;Jaehyung Cha;Bae Young Lee;Chan Ho Park;Eun-Ju Kang;Hyun Jung Koo;Kakuya Kitagawa;Min Jae Cha;Rungroj Krittayaphong;Sang Il Choi;Sanjaya Viswamitra;Sung Min Ko;Sung Mok Kim;Sung Ho Hwang;Nguyen Ngoc Trang;Whal Lee;Young Jin Kim;Jongmin Lee;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • v.23 no.3
    • /
    • pp.298-307
    • /
    • 2022
  • Objective: This study aimed to evaluate the effect of implementing the consensus statement from the Asian Society of Cardiovascular Imaging-Practical Tutorial 2020 (ASCI-PT 2020) on the reliability of cardiac MR with late gadolinium enhancement (CMR-LGE) myocardial viability scoring between observers in the context of ischemic cardiomyopathy. Materials and Methods: A total of 17 cardiovascular imaging experts from five different countries evaluated CMR obtained in 26 patients (male:female, 23:3; median age [interquartile range], 55.5 years [50-61.8]) with ischemic cardiomyopathy. For LGE scoring, based on the 17 segments, the extent of LGE in each segment was graded using a five-point scoring system ranging from 0 to 4 before and after exposure according to the consensus statement. All scoring was performed via web-based review. Scores for slices, vascular territories, and total scores were obtained as the sum of the relevant segmental scores. Interobserver reliability for segment scores was assessed using Fleiss' kappa, while the intraclass correlation coefficient (ICC) was used for slice score, vascular territory score, and total score. Inter-observer agreement was assessed using the limits of agreement from the mean (LoA). Results: Interobserver reliability (Fleiss' kappa) in each segment ranged 0.242-0.662 before the consensus and increased to 0.301-0.774 after the consensus. The interobserver reliability (ICC) for each slice, each vascular territory, and total score increased after the consensus (slice, 0.728-0.805 and 0.849-0.884; vascular territory, 0.756-0.902 and 0.852-0.941; total score, 0.847 and 0.913, before and after implementing the consensus statement, respectively. Interobserver agreement in scoring also improved with the implementation of the consensus for all slices, vascular territories, and total score. The LoA for the total score narrowed from ± 10.36 points to ± 7.12 points. Conclusion: The interobserver reliability and agreement for CMR-LGE scoring for ischemic cardiomyopathy improved when following guidance from the ASCI-PT 2020 consensus statement.

Development of Unfolding Energy Spectrum with Clinical Linear Accelerator based on Transmission Data (물질투과율 측정정보 기반 의료용 선형가속기의 에너지스펙트럼 유도기술 개발)

  • Choi, Hyun Joon;Park, Hyo Jun;Yoo, Do Hyeon;Kim, Byoung-Chul;Yi, Chul-Young;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.41-47
    • /
    • 2016
  • Background: For the accurate dose assessment in radiation therapy, energy spectrum of the photon beam generated from the linac head is essential. The aim of this study is to develop the technique to accurately unfolding the energy spectrum with the transmission analysis method. Materials and Methods: Clinical linear accelerator and Monet Carlo method was employed to evaluate the transmission signals according to the thickness of the observer material, and then the response function of the ion chamber response was determined with the mono energy beam. Finally the energy spectrum was unfolded with HEPROW program. Elekta Synergy Flatform and Geant4 tool kits was used in this study. Results and Discussion: In the comparison between calculated and measured transmission signals using aluminum alloy as an attenuator, root mean squared error was 0.43%. In the comparison between unfolded spectrum using HEPROW program and calculated spectrum using Geant4, the difference of peak and mean energy were 0.066 and 0.03 MeV, respectively. However, for the accurate prediction of the energy spectrum, additional experiment with various type of material and improvement of the unfolding program is required. Conclusion: In this research, it is demonstrated that unfolding spectra technique could be used in megavoltage photon beam with aluminum alloy and HEPROW program.

Video Camera Characterization with White Balance (기준 백색 선택에 따른 비디오 카메라의 전달 특성)

  • 김은수;박종선;장수욱;한찬호;송규익
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.2
    • /
    • pp.23-34
    • /
    • 2004
  • Video camera can be a useful tool to capture images for use in colorimeter. However the RGB signals generated by different video camera are not equal for the same scene. The video camera for use in colorimeter is characterized based on the CIE standard colorimetric observer. One method of deriving a colorimetric characterization matrix between camera RGB output signals and CIE XYZ tristimulus values is least squares polynomial modeling. However it needs tedious experiments to obtain camera transfer matrix under various white balance point for the same camera. In this paper, a new method to obtain camera transfer matrix under different white balance by using 3${\times}$3 camera transfer matrix under a certain white balance point is proposed. According to the proposed method camera transfer matrix under any other white balance could be obtained by using colorimetric coordinates of phosphor derived from 3${\times}$3 linear transfer matrix under the certain white balance point. In experimental results, it is demonstrated that proposed method allow 3${\times}$3 linear transfer matrix under any other white balance having a reasonable degree of accuracy compared with the transfer matrix obtained by experiments.

Development of a Home-based Nursing Intervention, Mothering Program for Low-Birth-Weight Infants (저체중출생아를 위한 가정간호형 모성역할중재 프로그램 개발과 그 효과에 대한 연구)

  • Han, Kyung-Ja
    • Journal of Home Health Care Nursing
    • /
    • v.8 no.1
    • /
    • pp.5-24
    • /
    • 2001
  • The purpose of this study was to develop a parenting intervention program and determine the efficacy of the program with low-birth weight infants and their mothers. Nine dyads for the experimental group and twelve dyads for the control group discharged from the Neonatal Intensive Care Unit of a University Hospital in Seoul were recruited for the study. For the intervention group, programmed education and support which focused on the maternal sensitivity of the infant's behavior. rearing environment. motherinfant interaction and infant care were given to each subject. Individual counseling and home visits were provided at discharge, one week after discharge. and one and three months of corrected age in every infant. Structured questionaires were administered and feeding interactions were videotaped and coded by a blinded certified observer. A Quasi-experimental design was conducted for this study. Postpartum depression, maternal self esteem. infant care burden, HOME. mother-infant interaction, and infant development were measured. Results were in favor of the intervention versus the control group. On the Beck depression inventory, intervention mothers showed decreasing trends in depressive symptom vs control mothers although, there were statistically no significant differences between the two groups at each time. The mean score of experimental group was 11.55(mild depression state) at discharge and became 8,6(normal state) at 1 month of corrected age. On the other hand, the mean score of the control group was 13.92(mild depression state) at discharge and became 14.0. Maternal self esteem in both groups improved over time. Infant care burden in both groups was also shown to increase over time. There was a significant difference between the two groups in HOME(p=.0340) at 3 months of corrected age. HOME scores of the experimental group and the control's were 31.10 and 25.58, respectively. Mothers' emotional and language responses were significantly high in the intervention group compared with the control group(p=.0155). Intervention group (53.33) showed a significantly high quality of motherinfant interaction compared with the in control group (42.80)(p =.0340). Intervention group mothers appeared have a better quality of mother-infant interaction behaviors. On the other hand, there was no statistical difference in the infant part between groups. Intervention group infants had higher trends in a general developmental quotient: although, there was no statistical difference between groups. The general developmental quotient of intervention infants was 102.56 and control's was 91.28. However, the developmental quotient of the domain of 'individuality-sociality' was higher in the intervention group infants compared with the control's(p=.0155). The concerns identified by parents revealed two domains of an infants' health management -knowledge and skills in caregiving of lowbirthweight-infants, characteristics of lowbirthweight infants, identifying a developmental milestone, coping with emergency situations and relaxation strategies of mothers from the infant care burden. Interview data with the mothers of low-birth weight infants can be used to develop intervention program contents. Limited intervention time and frequency due to time and cost limitations of this study should be modified. The intervention should be continuously implemented when low-birth weight infants become three years old. An NNNS demonstration appeared to be a very effective intervention for the mothers to improve the quality of mother-infant interactions. Therefore intervening in the mothers of low-birth weight infants as early after delivery as possible is desirable. This study has shown that home visit interventions are worthwhile for mothers only beyond the approach as an essential factor in ability of facilitating a growth fostering environment. In conclusion. the intervention program of this study was very effective in enhancing the parenting for the mothers of low-birth weight infants, resulting in health promotion of low-birth weight infants. The home-visit outreach intervention program of this study will contribute to the health delivery system in this country where there is a lack of continuous follow-up programs for low-birth weight infants after discharge from NICU, if it is activated as part of the home visit programs in community health systems.

  • PDF

The Study of Radiation Exposed dose According to 131I Radiation Isotope Therapy (131I 방사성 동위원소 치료에 따른 피폭 선량 연구)

  • Chang, Boseok;Yu, Seung-Man
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.653-659
    • /
    • 2019
  • The purpose of this study is to measure the (air dose rate of radiation dose) the discharged patient who was administrated high dose $^{131}I$ treatment, and to predict exposure radiation dose in public person. The dosimetric evaluation was performed according to the distance and angle using three copper rings in 30 patients who were treated with over 200mCi high dose Iodine therapy. The two observer were measured using a GM surverymeter with 8 point azimuth angle and three difference distance 50, 100, 150cm for precise radion dose measurement. We set up three predictive simulations to calculate the exposure dose based on this data. The most highest radiation dose rate was showed measuring angle $0^{\circ}$ at the height of 1m. The each distance average dose rate was used the azimuth angle average value of radiation dose rate. The maximum values of the external radiation dose rate depending on the distance were $214{\pm}16.5$, $59{\pm}9.1$ and $38{\pm}5.8{\mu}Sv/h$ at 50, 100, 150cm, respectively. If high dose Iodine treatment patient moves 5 hours using public transportation, an unspecified person in a side seat at 50cm is exposed 1.14 mSv radiation dose. A person who cares for 4days at a distance of 1 meter from a patient wearing a urine bag receives a maximum radiation dose of 6.5mSv. The maximum dose of radiation that a guardian can receive is 1.08mSv at a distance of 1.5m for 7days. The annual radiation dose limit is exceeded in a short time when applied the our developed radiation dose predictive modeling on the general public person who was around the patients with Iodine therapy. This study can be helpful in suggesting a reasonable guideline of the general public person protection system after discharge of high dose Iodine administered patients.

Diagnostic Performance of Digital Breast Tomosynthesis with the Two-Dimensional Synthesized Mammogram for Suspicious Breast Microcalcifications Compared to Full-Field Digital Mammography in Stereotactic Breast Biopsy (정위적 유방 조직검사 시 미세석회화 의심 병변에서의 디지털 유방단층영상합성법과 전역 디지털 유방촬영술의 진단능 비교)

  • Jiwon Shin;Ok Hee Woo;Hye Seon Shin;Sung Eun Song;Kyu Ran Cho;Bo Kyoung Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1090-1103
    • /
    • 2022
  • Purpose To evaluate the diagnostic performance of digital breast tomosynthesis (DBT) with the two-dimensional synthesized mammogram (2DSM), compared to full-field digital mammography (FFDM), for suspicious microcalcifications in the breast ahead of stereotactic biopsy and to assess the diagnostic image visibility of the images. Materials and Methods This retrospective study involved 189 patients with microcalcifications, which were histopathologically verified by stereotactic breast biopsy, who underwent DBT with 2DSM and FFDM between January 8, 2015, and January 20, 2020. Two radiologists assessed all cases of microcalcifications based on Breast Imaging Reporting and Data System (BI-RADS) independently. They were blinded to the histopathologic outcome and additionally evaluated lesion visibility using a fivepoint scoring scale. Results Overall, the inter-observer agreement was excellent (0.9559). Under the setting of category 4A as negative due to the low possibility of malignancy and to avoid the dilution of malignancy criteria in our study, McNemar tests confirmed no significant difference between the performances of the two modalities in detecting microcalcifications with a high potential for malignancy (4B, 4C, or 5; p = 0.1573); however, the tests showed a significant difference between their performances in detecting microcalcifications with a high potential for benignancy (4A; p = 0.0009). DBT with 2DSM demonstrated superior visibility and diagnostic performance than FFDM in dense breasts. Conclusion DBT with 2DSM is superior to FFDM in terms of total diagnostic accuracy and lesion visibility for benign microcalcifications in dense breasts. This study suggests a promising role for DBT with 2DSM as an accommodating tool for stereotactic biopsy in female with dense breasts and suspicious breast microcalcifications.

Quantification of the Elastic Property of Normal Thigh Muscles Using MR Elastography: Our Initial Experience (자기 공명 탄성 검사를 이용한 대퇴 근육의 탄성도의 정량화: 초기 경험)

  • Junghoon Kim;Jeong Ah Ryu;Juhan Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1556-1564
    • /
    • 2021
  • Purpose This study aimed to apply MR elastography (MRE) to achieve in vivo evaluation of the elastic properties of thigh muscles and validate the feasibility of quantifying the elasticity of normal thigh muscles using MRE. Materials and Methods This prospective study included 10 volunteer subjects [mean age, 32.5 years, (range, 23-45 years)] who reported normal activities of daily living and underwent both T2-weighted axial images and MRE of thigh muscles on the same day. A sequence with a motion-encoding gradient was used in the MRE to map the propagating shear waves in the muscle. Elastic properties were quantified as the shear modulus of the following four thigh muscles at rest; the vastus medialis, vastus lateralis, adductor magnus, and biceps femoris. Results The mean shear modulus was 0.98 ± 0.32 kPa and 1.00 ± 0.33 kPa for the vastus medialis, 1.10 ± 0.46 kPa and 1.07 ± 0.43 kPa for the vastus lateralis, 0.91 ± 0.41 kPa and 0.93 ± 0.47 kPa for the adductor magnus, and 0.99 ± 0.37 kPa and 0.94 ± 0.32 kPa for the biceps femoris, with reader 1 and 2, respectively. No significant difference was observed in the shear modulus based on sex (p < 0.05). Aging consistently showed a statistically significant negative correlation (p < 0.05) with the shear modulus of the thigh muscles, except for the vastus medialis (p = 0.194 for reader 1 and p = 0.355 for reader 2). Conclusion MRE is a quantitative technique used to measure the elastic properties of individual muscles with excellent inter-observer agreement. Age was consistently significantly negatively correlated with the shear stiffness of muscles, except for the vastus medialis.