• Title/Summary/Keyword: Oblique field

Search Result 143, Processing Time 0.021 seconds

Buzz Suppression of Supersonic Air Inlet by Cowl Position Modification (카울 위치변화에 의한 초음속 공기흡입구의 버즈억제)

  • Shin, Phil-Kwon;Park, Jong-Ho;Lee, Yong-Bum
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.10-17
    • /
    • 2005
  • An experimental study was conducted at a Mach number of 2.0 to investigate the buzz suppression method on an axisymmetric, external compression supersonic inlet. The inlet model has a fixed geometry with no internal contraction. The inlet configuration was altered by changing the cowling. Results show that source of buzz has been related to the existence in the flow field of velocity discontinuity across a vortex sheet which originates from a shock intersection point. With external compression inlet, buzz can be suppressed by positioning the oblique shock slightly inside or outside of the cowl.

Electro-Optical Characteristics of the UV Aligned LCD Cell (UV 배향된 액정셀에서의 전기광학 특성)

  • Lee, Byung-Soon;Lee, Ho-Young
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.4
    • /
    • pp.223-226
    • /
    • 2013
  • In this study, we investigated the electro-optical(EO) characteristic of fringe-field switching(FFS) mode cell by the two kinds of ultraviolet(UV) alignment method on the organic thin film(polyimide: PI). The suitable organic layersfor FFS cell and the aligning capabilities of nematic liquid crystal(NLC) using the in-situ photoalignment method were studied Disclination is observed after conventional photoalignment method for 1h, and in-situ photoalignment method for 1h. Monodomain alignment of the NLC can be observed via in-situ photoalignment method for 2h and 3h. It is considered that NLC alignment is due to photo-depolymerization of the polymer with oblique non-polarized UV irradiation on PI surface. An unstable V-T curve of UV-aligned FFS-LCD with conventional photoalignment method can be achieved. However, a stable V-T curve of UV-aligned FFS-LCD with in-situ photoalignment method(1h), and V-T curve of UV-aligned FFS-LCD with in-situphotoalignment method was much stable comparing with that of other UV-aligned FFS-LCD's. As a result, more stable EO performanceof UV-aligned FFS-LCD with in-situphotoalignment method for 3h is obtained than that of the other UV-aligned FFS-LCD's.

Study on In-Plane Switching mode with discotic compensation film (Discotic 필름 보상형 In-Plane Switching 모드에 관한 연구)

  • Song, I.S.;Baik, I.S.;Jung, B.S.;Jeon, Y.M.;Lee, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.518-521
    • /
    • 2004
  • We have investigated about compensation film to reduce the light leakage at an oblique angle in-plane switching mode. It is well known that uncompensated in-plane switching (US) and fringe field switching (FFS) liquid crystal displays (LCDs) have much better viewing angle than other modes owing to the in-plane rotation of the LC director. However, to accomplish optimal viewing angle characteristics in these devices, they must be compensated by one or more films. So, in this paper, we have studied how to reduce the light leakage with viewing angle using discotic film in dark state.

  • PDF

Estimation Carbon Storage of Urban Street trees Using UAV Imagery and SfM Technique (UAV 영상과 SfM 기술을 이용한 가로수의 탄소저장량 추정)

  • Kim, Da-Seul;Lee, Dong-Kun;Heo, Han-Kyul
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.22 no.6
    • /
    • pp.1-14
    • /
    • 2019
  • Carbon storage is one of the regulating ecosystem services provided by urban street trees. It is important that evaluating the economic value of ecosystem services accurately. The carbon storage of street trees was calculated by measuring the morphological parameter on the field. As the method is labor-intensive and time-consuming for the macro-scale research, remote sensing has been more widely used. The airborne Light Detection And Ranging (LiDAR) is used in obtaining the point clouds data of a densely planted area and extracting individual trees for the carbon storage estimation. However, the LiDAR has limitations such as high cost and complicated operations. In addition, trees change over time they need to be frequently. Therefore, Structure from Motion (SfM) photogrammetry with unmanned Aerial Vehicle (UAV) is a more suitable method for obtaining point clouds data. In this paper, a UAV loaded with a digital camera was employed to take oblique aerial images for generating point cloud of street trees. We extracted the diameter of breast height (DBH) from generated point cloud data to calculate the carbon storage. We compared DBH calculated from UAV data and measured data from the field in the selected area. The calculated DBH was used to estimate the carbon storage of street trees in the study area using a regression model. The results demonstrate the feasibility and effectiveness of applying UAV imagery and SfM technique to the carbon storage estimation of street trees. The technique can contribute to efficiently building inventories of the carbon storage of street trees in urban areas.

Effect of slice inclination and object position within the field of view on the measurement accuracy of potential implant sites on cone-beam computed tomography

  • Saberi, Bardia Vadiati;Khosravifard, Negar;Nourzadeh, Alireza
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.37-43
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the accuracy of linear measurements in the horizontal and vertical dimensions based on object position and slice inclination in cone-beam computed tomography (CBCT) images. Materials and Methods: Ten dry sheep hemi-mandibles, each with 4 sites (incisor, canine, premolar, and molar), were evaluated when either centrally or peripherally positioned within the field of view (FOV) with the image slices subjected to either oblique or orthogonal inclinations. Four types of images were created of each region: central/cross-sectional, central/coronal, peripheral/cross-sectional, and peripheral/coronal. The horizontal and vertical dimensions were measured for each region of each image type. Direct measurements of each region were obtained using a digital caliper in both horizontal and vertical dimensions. CBCT and direct measurements were compared using the Bland-Altman plot method. P values <0.05 were considered to indicate statistical significance. Results: The buccolingual dimension of the incisor and premolar areas and the height of the incisor, canine, and molar areas showed statistically significant differences on the peripheral/coronal images compared to the direct measurements (P<0.05). Molar area height in the central/coronal slices also differed significantly from the direct measurements (P<0.05). Cross-sectional images of either the central or peripheral position had no marked difference from the gold-standard values, indicating sufficient accuracy. Conclusion: Peripheral object positioning within the FOV in combination with applying an orthogonal inclination to the slices resulted in significant inaccuracies in the horizontal and vertical measurements. The most undesirable effect was observed in the molar area and the vertical dimension.

A Study on Model Establishment and Structural Analysis for Gun Blast Load (기총 폭발 하중에 대한 모델 수립과 구조 해석에 관한 연구)

  • Kim, Dae-Kwan;Han, Jae-Hung;Jang, Jae-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.7
    • /
    • pp.33-39
    • /
    • 2005
  • A mathematical model, GUNBLAST, of blast waves emitted from a gun muzzle is established, and structural response analyses for the blast load are performed. The blast wave can be divided into two kinds of waves, free field and reflected blast waves. In this research, the free field blast wave model is established by the use of a scaling approach, and the reflected blast wave is calculated by using the oblique shock theory and computational fluid dynamic calculation. GUNBLAST is applied to two kinds of structural models. To investigate the effect of the muzzle distance from a structural surface, the blast waves on a plate for various muzzle distances are compared to uniform loads. Moreover, the transient response analysis of an aircraft wing model with a 12.7mm gun is carried out by using MSC/NASTRAN. From the results, it can be shown that the blast wave can cause broad random vibration and high frequency damage to equipments mounted in the aircraft.

Magnetization Reversal of Exchange-biased Bilayers and Trilayers Probed using Front and Back LT-MOKE

  • Kim, Ki-Yeon;Kim, Ji-Wan;Choi, Hyeok-Cheol;You, Chun-Yeol;Shin, Sung-Chul;Lee, Jeong-Soo
    • Journal of Magnetics
    • /
    • v.14 no.1
    • /
    • pp.36-41
    • /
    • 2009
  • Magneto-optical Kerr effect (MOKE) magnetometry was used to investigate magnetization reversal dynamics in 30-nm NiFe/15-nm FeMn, 15-nm FeMn/30-nm CoFe bilayers, and 30-nm NiFe/(2,10)-nm FeMn/30-nm CoFe trilayers. The in-plane magnetization components of each ferromagnetic layer, both parallel and perpendicular to the applied field, were separately determined by measuring the longitudinal and transverse MOKE hysteresis loops from both the front and back sides of the film for an oblique incident s-polarized beam. The magnetization of the FeMn/CoFe bilayer was reversed abruptly and symmetrically through nucleation and domain wall propagation, while that of the NiFe/FeMn bilayer was reversed asymmetrically with a dominant rotation. In the NiFe/FeMn/CoFe trilayers, the magnetic reversal of the two ferromagnetic layers proceeded via nucleation and domain wall propagation for 2-nm FeMn, but via asymmetric rotation for 10-nm FeMn. The exchange-biased ferromagnetic layers showed the magnetization reversal along the same path in the film plane for the decreasing and increasing field branches from transverse MOKE hysteresis loops, which can be qualitatively explained by the theoretical model of the exchange-biased ferromagnetic/antiferromagnetic systems.

An Experimental Study of the Effect of the Test-well Arrangement on the Partitioning Interwell Tracer Test for the Estimation of the NAPL Saturation (지하수 유동 방향에 대한 관정배열이 분배추적자 시험에 미치는 영향 분석)

  • Kim, Bo-A;Kim, Yongcheol;Yeo, In Wook;Ko, Kyung-Seok
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.111-122
    • /
    • 2014
  • Partitioning interwell tracer test (PITT) is a method to quantify and qualify a site contaminated with NAPLs (Non-Aqueous Phase Liquids). Analytical description of PITT assumes that the injection-pumping well pair is on the line of the ambient groundwater flow direction, but the test-well pair could frequently be off the line in a real field site, which could be an erroneous factor in analyzing PITT data. The purpose of this work is to study the influence of the angle of the test-well pair on the ambient groundwater flow direction based on the result from PITT. From the experiments, it was found that the obliqueness of the test-well pair to the ambient groundwater flow direction could affect the tracer test resulting in a decreased NAPL estimation efficiency. In case of an oblique arrangement of the test-well pair to the ambient flow direction, it was found that the injection of a chase fluid could enhance the estimation efficiency. An increase of the pumping rate could enhance the recovery rate but it cannot be said that a high pumping rate can increase the test efficiency because a high pumping rate cannot give partitioning tracers enough time to partition into NAPLs. The results have a implication that because the arrangement of the test-well pair is a controlling factor in performing and interpreting PITT in the field in addition to the known factors such as heterogeneity and the source zone architecture, flow direction should be seriously considered in arranging test-well pair.

MR Neurography: Current Several Issues for Novice Radiologists (자기공명영상 신경조영술: 경험이 적은 영상의학과 의사가 이해해야 할 몇 가지 쟁점들)

  • Dong-ho Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.81-100
    • /
    • 2020
  • Magnetic resonance neurography (MRN) has been increasingly used in recent years for the assessment of peripheral neuropathies. Fat suppression T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) have typically been used to provide high contrast MRN. Isotropic 3-dimensional (3D) sequences with fast spin echo, post-processing imaging techniques, and fast imaging methods, among others, allow good visualization of peripheral nerves that have a small diameter, complex anatomy, and oblique course within a reasonable scan time. However, there are still several issues when performing high contrast and high resolution MRN including standard sequence; fat saturation techniques; balance between resolution, field of view, and slice thickness; post-processing techniques; 2D vs. 3D image acquisition; different T2 contrasts between proximal and distal nerves; high T2 signal intensity of adjacent veins or joint fluid; geometric distortion; and appropriate p-values on DWI. The proper understanding of these issues will help novice radiologists evaluate peripheral neuropathies using MRN.

Factor Analysis for Exploratory Research in the Distribution Science Field (유통과학분야에서 탐색적 연구를 위한 요인분석)

  • Yim, Myung-Seong
    • Journal of Distribution Science
    • /
    • v.13 no.9
    • /
    • pp.103-112
    • /
    • 2015
  • Purpose - This paper aims to provide a step-by-step approach to factor analytic procedures, such as principal component analysis (PCA) and exploratory factor analysis (EFA), and to offer a guideline for factor analysis. Authors have argued that the results of PCA and EFA are substantially similar. Additionally, they assert that PCA is a more appropriate technique for factor analysis because PCA produces easily interpreted results that are likely to be the basis of better decisions. For these reasons, many researchers have used PCA as a technique instead of EFA. However, these techniques are clearly different. PCA should be used for data reduction. On the other hand, EFA has been tailored to identify any underlying factor structure, a set of measured variables that cause the manifest variables to covary. Thus, it is needed for a guideline and for procedures to use in factor analysis. To date, however, these two techniques have been indiscriminately misused. Research design, data, and methodology - This research conducted a literature review. For this, we summarized the meaningful and consistent arguments and drew up guidelines and suggested procedures for rigorous EFA. Results - PCA can be used instead of common factor analysis when all measured variables have high communality. However, common factor analysis is recommended for EFA. First, researchers should evaluate the sample size and check for sampling adequacy before conducting factor analysis. If these conditions are not satisfied, then the next steps cannot be followed. Sample size must be at least 100 with communality above 0.5 and a minimum subject to item ratio of at least 5:1, with a minimum of five items in EFA. Next, Bartlett's sphericity test and the Kaiser-Mayer-Olkin (KMO) measure should be assessed for sampling adequacy. The chi-square value for Bartlett's test should be significant. In addition, a KMO of more than 0.8 is recommended. The next step is to conduct a factor analysis. The analysis is composed of three stages. The first stage determines a rotation technique. Generally, ML or PAF will suggest to researchers the best results. Selection of one of the two techniques heavily hinges on data normality. ML requires normally distributed data; on the other hand, PAF does not. The second step is associated with determining the number of factors to retain in the EFA. The best way to determine the number of factors to retain is to apply three methods including eigenvalues greater than 1.0, the scree plot test, and the variance extracted. The last step is to select one of two rotation methods: orthogonal or oblique. If the research suggests some variables that are correlated to each other, then the oblique method should be selected for factor rotation because the method assumes all factors are correlated in the research. If not, the orthogonal method is possible for factor rotation. Conclusions - Recommendations are offered for the best factor analytic practice for empirical research.