• Title/Summary/Keyword: Oblique condition

Search Result 149, Processing Time 0.025 seconds

A Study on the Optimum Design of Stiffened Plates under Combined Loads (조합하중이 작용하는 보강평판의 최적설계 연구)

  • 원종진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1059-1068
    • /
    • 1990
  • The minimum weight design for the simply-supported eccentrically stiffened plates subjected to combined loads is studied according to the stiffening configuration. The optimal programming is accomplished by formulating the design requirements in terms of a mathematical programming problem, and by using the gradient projection algorithm. The Huber type equilibrium equation is used as the governing equation for the overall buckling. The overall buckling of stiffened plates and the local buckling of the unstiffened plate between stiffeners and the stiffeners themselves are used as behavior constraints. Results of design examples for the orthogonally stiffening case compared with those of the other study support that the present study is feasible. Design examples for the symmetrically oblique stiffening case are presented and the results indicate that a significant improvement in design efficiency may be achieved through symmetrically oblique stiffening compared to the orthogonal stiffening under the combined loading condition.

Reliability and Validity of Ultrasound Imaging and sEMG Measurement to External Abdominal Oblique and Lumbar Multifidus Muscles (외복사근과 다열근에 대한 초음파 영상과 표면 근전도 측정방법의 신뢰도와 타당도)

  • Kim, Chang-Yong;Choi, Jong-Duk;Kim, Suhn-Yeop;Oh, Duck-Won;Kim, Jin-Kyung
    • Physical Therapy Korea
    • /
    • v.18 no.1
    • /
    • pp.37-46
    • /
    • 2011
  • The purpose of this study was to investigate intra-rater reliability and determine the validity of electromyography (EMG) measurements to represent muscle activity and ultrasonography (US) to represent muscle thickness during manual muscle testing (MMT) to external abdominal oblique (EO) and lumbar multifidus (MF). Twenty healthy subjects were recruited for this study and asked to perform MMT at differing levels. The subjects' muscle activity using EMG was measured by a ratio to maximum voluntary contraction (MVC) and root mean square (RMS) methods. The subjects' muscle thickness using US was measured by raw muscle thickness and change ratio of thickness to maximum (MVC) or resting condition. In three trials, measurements were performed on each subject by one examiner. The intra-rater reliability of measurements of EMG and US to EO and MF was calculated using intra-class coefficients. The intra-rater reliability of all measurements was excellent (ICC=.75~.98) in EMG and US. The conduct validity was calculated by one-way ANOVA with repeated measurements to compare whether the EMG and US measurements were different between MMT at different levels. There was only a significant difference between all grades at %MVC thickness measurement of US. These results suggest that a %MVC thickness measurement of US was a more sensitive and discriminate in all manual muscle testing grades. This information will be useful for the selection of US measurement and analysis methods in clinics.

A STUDY ON THE VARIOUS IMPLANT SYSTEMS USING THE FINITE ELEMENT STRESS ANALYSIS (수종의 임플랜트 시스템에 따른 유한요소법적 응력분석에 관한 연구)

  • Yu Seong-Hyun;Park Won-Hee;Park Ju-Jin;Lee Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.207-216
    • /
    • 2006
  • Statement of Problem: To conduct a successful function of implant prosthesis in oral cavity for a long time, it is important that not only structure materials must have the biocompatibility, but also the prosthesis must be designed for the stress, which is occurred in occlusion, to scatter adequately within the limitation of alveolar bone around implant and bio-capacity of load support. Now implant which is used in clinical part has a very various shapes, recently the fixture that has tapered form of internal connection is often selected. However the stress analysis of fixtures still requires more studies. Purpose: The purpose of this study is to stress analysis of the implant prosthesis according to the different implant systems using finite element method. Material and methods: This study we make the finite element models that three type implant fixture ; $Br{\aa}nemark$, Camlog, Frialit-2 were placed in the area of mandibular first premolar and prosthesis fabricated, which we compared with stress distribution using the finite element analysis under two loading condition. Conclusion: The conclusions were as follows: 1. In all implant system, oblique loading of maximum Von mises stress of implant, alveolar bone and crown is higher than vertical loading of those. 2. Regardless of loading conditions and the type of system. cortical bone which contacts with implant fixture top area has high stress, and cancellous bone has a little stress. 3. Under the vertical loading, maximum Von mises stress of $Br{\aa}nemark$ system with external connection type and tapered form is lower than Camlog and Frialit-2 system with internal connection type and tapered form, but under oblique loading Camlog and Frialit-2 system is lower than $Br{\aa}nemark$ system.

Numerical Study on Prediction of Flare Slamming Load on Container Ship under Head Sea and Oblique Sea Conditions (선수파 및 사파조건에서 컨테이너선의 선수 플레어 슬래밍 하중 추정에 관한 수치적 연구)

  • Seo, Dae-Won;Oh, Jungkeun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.4
    • /
    • pp.489-497
    • /
    • 2019
  • A ship operating under rough sea conditions is exposed to a slamming load due owing to its motion relative to encountered waves. In the process of reentering the water, the ship's structure is temporarily subjected to an impact pressure. In particular, bow flare slamming often occurs in large container ships with a large flare angle, and can cause structural damage. Numerical simulations were performed in this study, and the results were compared with reliable experimental results. The simulation results were also used to estimate the bow flare slamming pressures on a container ship under head sea and oblique sea conditions. It was found that a maximum impact pressure of 475 kPa was generated near the 0.975 station of the container ship under a head sea condition.

The Effects of Hip Joint Movement on the Lumbo-pelvic Muscle Activities and Pelvic Rotation During Four-point Kneeling Arm and Leg Lift Exercise in Healthy Subjects

  • Nam-goo Kang;Won-jeong Jeong;Min-ju Ko;Jae-seop ,Oh
    • Physical Therapy Korea
    • /
    • v.30 no.2
    • /
    • pp.144-151
    • /
    • 2023
  • Background: The gluteus maximus (GM) muscle comprise the lumbo-pelvic complex and is an important stabilizing muscle during leg extension. In patients with low back pain (LBP) with weakness of the GM, spine leads to compensatory muscle activities such as instantaneous increase of the erector spinae (ES) muscle activity. Four-point kneeling arm and leg lift (FKALL) is most common types of lumbopelvic and GM muscles strengthening exercise. We assumed that altered hip position during FKALL may increase thoraco-lumbar stabilizer like GM activity more effectively method. Objects: The purpose of this study was investigated that effects of the three exercise postures on the right-sided GM, internal oblique (IO), external oblique (EO), and multifidus (MF) muscle activities and pelvic kinematic during FKALL. Methods: Twenty eight healthy individuals participated in this study. The exercises were performed three conditions of FKALL (pure FKALL, FKALL with 120° hip flexion of the supporting leg, FKALL with 30° hip abduction of the lifted leg). Participants performed FKALL exercises three times each condition, and motion sensor used to measure pelvic tilt and rotation angle. Results: This study demonstrated that no significant change in pelvic angle during hip movement in the FKALL (p > 0.05). However, the MF and GM muscle activities in FKALL with hip flexion and hip abduction is greater than pure FKALL position (p < 0.001). Conclusion: Our finding suggests that change the posture of the hip joint to facilitate GM muscle activation during trunk stabilization exercises such as the FKALL.

NUMERICAL SIMULATION OF SUPERSONIC FLOW USING POROUS AND ROUGH WALL BOUNDARY CONDITIONS (다공성 벽면(porous-wall)과 거칠기가 있는 벽면(rough-wall)에 과한 경계조건을 이용한 초음속 흐름의 수치모사)

  • Kwak, E.K.;Yoo, I.Y.;Lee, S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.104-111
    • /
    • 2009
  • The existing code which solves two-dimensional RANS(Reynolds Averaged Navier-Stokes) equations and 2-equation turbulence model equations was modified to enable numerical simulation of various supersonic flows. For this, various boundary conditions have been implemented to the code. Bleed boundary condition was incorporated into the code for calculating wall mean flow quantities. Furthermore, the boundary conditions for the turbulence quantities along rough surfaces as well as porous walls were applied to the code. The code was verified and validated by comparing the computational results against the experimental data for the supersonic flows over bleed region on a flat plate. Using the newly modified code, numerical simulations were performed and compared with other computational results as well as the experimental data for the supersonic flows over an oblique shock with a bleed region.

  • PDF

Numerical Simulation of Supersonic Inlet Flow (초음속 흡입구 유동의 수치모사)

  • Kwak, Ein-Keun;Yoo, Il-Yong;Lee, Seung-Soo;Jung, Suk-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.133-137
    • /
    • 2009
  • Numerical simulations of flows in an axisymmetric supersonic inlet with bleed regions were performed. For the simulations, the existing code which solves the RANS(Reynolds Averaged Navier-Stokes) equations and 2-equation turbulence model equations was transformed to axisymmetric form and bleed boundary condition was applied to the code. In this paper, the modified code was validated by comparing the results against an experimental data and other computational results for flow on a bump and over an oblique shock with bleed region. Using the code, numerical simulations were performed for the flow in the inlet with multiple bleed regions.

  • PDF

A Case of Mandibular Prognathism Treated by Oblique Osteotomy (사선골절단술에 의한 하악 전돌증의 치험례)

  • Choie, Mok-Kyun;Bae, Chang;Lee, Bong-Won
    • The Journal of the Korean dental association
    • /
    • v.17 no.2 s.117
    • /
    • pp.129-135
    • /
    • 1979
  • This 27 year-old male patient had severe mandibular prognathism (right and left mesio-occlusion were 0.4㎝ and 1.2㎝ , respectively). He had good oral health relatively exception of missing teeth. We examined all of his oral and skeletal status with full mouth x-ray taking, study model, and cephalogram. His general condition was good but above examination indicated the surgical operation for the mandibular prognathism. His laboratory tests were within normal limits. We determined surgical operation which was done by extraoral approach bilaterally. Incisions were made bilaterally 1.5㎝ beneath the inferior border of the mandible in the selected area and then the inferior border of the ascending rami was exposed. Retracting the periosteum to the lingual and buccal a slight amount, the cut in the bone was performed by use of bone drill. Avoiding T.M.J. troubles, the proximal segmant was not fixed to anterior segment, being in overlapping state buccally, in order to expect a natural healing by the environmental muscles and ligaments. We had immobilization with intermaxillary fixation by using the multiple Stout's method. He was discharged 17 days after operation. His general condition and operation results were good and satisfactory.

  • PDF

A Study on Free Surface Cutting Force System of Conical Tipped Circular Cutting Edge Ball End Mill (圓錐팁 Ball End Mill 의 3次元 曲面切削力系에 관한 硏究)

  • 박천향;맹희구
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.4
    • /
    • pp.440-451
    • /
    • 1985
  • This study is concerned with the analysis of cutting force system acting on ball-nose end mill in three-dimensional surface machining process. Conical tipped circular cutting edge element model and free surface machining process types are proposed to apply oblique cutting theory, and then derived equations are used for numerical approach of cutting force curves by matrix method. This approach has a good agreement with experimental results both in magnitude and shape within the range of 15 percent, which was conformed on 6061-T6 aluminum workpiece having twofold curvatured surface. From the cutting load variation to edge location, it is confirmed that circular cutting edge shapes has a better cutting ability than that of straight and both have a singularity near a tool point. It is also verified that what kind of machining condition is recommendable for three-dimensional machining process in connection with deflection of the cutter to workpiece and tool point wearing or system stability.

RANS Simulations for KRISO Container Ship and VLCC Tanker (KRISO 컨테이너 및 VLCC선형에 대한 RANS 시뮬레이션)

  • Kim, Jin;Park, Il-Ryong;Kim, Kwang-Soo;Van, Suak-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.6 s.144
    • /
    • pp.593-600
    • /
    • 2005
  • The finite volume based multi-block RANS code, WAVIS developed at KRISO, is used to simulate the turbulent flow field around the KRISO container ship (KCS) and the modified KRISO tanker (KVLCC2M). The realizable k-$\varepsilon$ turbulence model with a wall function is employed for the turbulence closure. The free surface flow with and without propeller is mainly investigated for the KCS and the double model flow is concerned for the KVLCC2M which is obliquely towed in still water. The computed results are compared with the experimental data provided by CFD Tokyo Workshop 2005 in terms of wave profiles, hull surface pressure and wake distribution with and without propeller for the HCS and wake distribution and hydrodynamic forces and moments with various drift angles for the KVLCC2M.