• Title/Summary/Keyword: Oblique Rib

Search Result 11, Processing Time 0.027 seconds

Design Optimization of Three-Dimensional Channel Roughened by Oblique Ribs Using Response Surface Method (반응면 기법을 이용한 경사진 리브가 부착된 삼차원 열전달유로의 최적설계)

  • Kim, Hong-Min;Kim, Kwang-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.7
    • /
    • pp.879-886
    • /
    • 2004
  • A numerical optimization has been carried out to determine the shape of the three-dimensional channel with oblique ribs attached on both walls to enhance turbulent heat transfer. The response surface based optimization is used as an optimization technique with Reynolds-averaged Navier-Stokes analysis of fluid flow and heat transfer. Shear stress transport (SST) turbulence model is used as a turbulence closure. Numerical results fur heat transfer rate show good agreements with experimental data. four dimensionless variables such as, rib pitch-to-rib height ratio, rib height-to-channel height ratio, streamwise rib distance on opposite wall to rib pitch ratio, and the attack angle of the rib are chosen as design variables. The objective function is defined as a linear combination of heat-transfer and friction-loss related coefficients with a weighting factor. D-optimal method is used to determine the training points as a means of design of experiment. Sensitivity of the objective parameters to each design variable has been analyzed. And, optimal values of the design variables have been obtained in a range of the weighting factor.

Effects of Lower Rib Expansion Limitation on Maximal Respiratory Pressure and Abdominal Muscle Activity During Maximal Breathing in Healthy Subjects

  • Lee, Gyu-wan;Yoon, Tae-Lim;Lee, Young-jung;Kim, Ki-song;Yi, Chung-hwi
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.6
    • /
    • pp.394-399
    • /
    • 2020
  • Purpose: The aim of this study was to determine the effects of lower rib cage lateral expansion limitation on the maximal inspiratory and expiratory pressures and on abdominal muscle activity during maximal respiratory breathing in healthy subjects. Methods: Fifteen healthy male subjects voluntarily participated in this cross-sectional study. During maximal breathing, maximal inspiratory and expiratory pressures were measured, and abdominal muscle activity was determined with using surface electromyography. Also, the measurement was repeated with using a non-elastic belt to the lower rib cage for limiting of lateral expansion. A Wilcoxon signed-rank test was performed for obtaining the statistical difference with a significance level of 0.05. Results: The findings of this study are as follows: 1) There were no significant differences in maximal inspiratory and expiratory pressure with and without lower rib cage lateral expansion (p>0.05), 2) There was no significant difference in abdominal muscle activity during the maximal inspiratory phase (p>0.05). However, right external oblique muscle activity decreased significantly during maximum exhalation with lower rib expansion limitation (p<0.05). Conclusion: The results of the current study indicate that a non-elastic belt was effective in decreasing right external oblique muscle activity during forced expiratory breathing in healthy subjects.

The Study of Effectiveness in a Modified Rib Oblique Projection View Using a Chest Phantom (흉부팬텀을 이용한 변형된 늑골 사방향 검사의 유용성에 관한 연구)

  • Um, Ki-Tae;Lee, Min-Su;Kang, Sung-Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.525-532
    • /
    • 2018
  • This study is filmed by applying the axial angle variation of the X-ray tube instead of the patient's position change during the perimetric examination of the ribs. A Reference image with the rib oblique examination using a chest phantom and experimental images applied with a six-phase variation in the axial angle by increasing $5^{\circ}$ tube angle each from $5^{\circ}{\sim}30^{\circ}$ from the vertical incident direction of the chest phantom to the right horizontal axis were obtained. For the quantitative comparative evaluation of the images, SNR and CNR were calculated for regions of interest in the experimental images based on the reference image. Also, the left-right rib ratio in the reference image and the left-right rib ratio in the experimental images are measured and compared. As a result of the study, the experimental images with a tube angle of $25^{\circ}$ were best shown in the measurements of the SNR, CNR and left-right rib ratio compared to the reference image with a standard examination method. The modified rib examinations will consider useful, if it is difficult to maintain the patient's examination position.

Effects of Contraction of Abdominal Muscles on Electromyographic Activities of Superficial Cervical Flexors, Rib Cage Elevation and Angle of Craniocervical Flexion During Deep Cervical Flexion Exercise (심부경부굴곡 운동 시 복근 수축이 표면경부굴곡근의 근활성도, 흉곽 거상, 두개경부굴곡 각도에 미치는 영향)

  • Park, Kyue-Nam;Won, Jong-Hyuck;Lee, Won-Hwee;Chung, Sung-Dae;Jung, Doh-Heon;Oh, Jae-Seop
    • Physical Therapy Korea
    • /
    • v.16 no.3
    • /
    • pp.9-15
    • /
    • 2009
  • The purpose of this study was to examine contraction of abdominal muscles on surface electromyographic (EMG) activity of superficial cervical flexors, rib cage elevation and angle of craniocervical flexion during deep cervical flexion exercise in supine position. Fifteen healthy subjects were participated for this study. All subjects performed deer cervical flexion exercise with two methods. The positions of two methods were no volitional contraction of abdominal muscles in hook-lying position with 45 degree hip flexion (method 1) and 90 degrees hip and knee flexion with feet off floor for inducing abdominal muscle contraction (method 2). Surface EMG activities were recorded from five muscles (sternocleidmastoid, anterior scaleneus, recuts abdominis, external oblique, internal oblique). And distance of rib cage elevation and angle of craniocervical flexion were measured using a three dimensional motion analysis system. The EMG activity of each muscle was normalized to the value of reference voluntary contraction (%RVC). The EMG activities, distance of rib cage elevation. and angle of craniocervical were compared using a paired t-test between two methods. The results showed that the EMG activities of sternocleidmastoid and anterior scaleneus during deep cervical flexion exercise in method 2 were significantly decreased compared to method 1 (p<.05). Distance of rib cage elevation and angle of craniocervical flexion were significantly decreased in method 2 (p<.05). The findings of this study indicated that deep cervical flexion exercise with contraction of abdominal muscles could be an effective method to prevent substitute motion for rib cage elevation and contraction of superficial neck flexor muscles.

  • PDF

Inter-Rater Reliability of Abdominal Muscles Thickness Using Ultrasonography for Different Probe Locations and Thickness Measurement Techniques

  • Lim, One-Bin;Hong, Ji-A;Yi, Chung-Hwi;Cynn, Heon-Seock;Jung, Doh-Heon;Park, Il-Woo
    • Physical Therapy Korea
    • /
    • v.18 no.4
    • /
    • pp.60-67
    • /
    • 2011
  • Ultrasonography (US) is a recent technique that has proven to be useful for assessing muscle thickness and guiding the rehabilitation decision-making of clinicians and researchers. The purpose of this study was to determine the inter-rater reliability of the US measurement of transversus abdominis (TrA), internal oblique (IO), and external oblique (EO) thicknesses for different probe locations and measurement techniques. Twenty healthy volunteers were recruited in this study. Muscle thicknesses of the transversus TrA, IO, and EO were measured three times in the hook-lying position. The three different probe locations were as follows: 1) Probe location 1 (PL1) was below the rib cage in direct vertical alignment with the anterior superior iliac spine (ASIS). 2) Probe location 2 (PL2) was halfway between the ASIS and the ribcage along the mid-axillary line. 3) Probe location 3 (PL3) was halfway between the iliac crest and the inferior angle of the rib cage, with adjustment to ensure the medial edge of the TrA. The two different techniques of thickness measurement from the captured images were as follows: 1) Muscle thickness was measured in the middle of the muscle belly, which was centered within the captured image (technique A; TA). 2) Muscle thickness was measured along a horizontal reference line located 2 cm apart from the medial edge of the TrA in the captured image (technique B; TB). The intraclass correlation coefficient (ICC [3,k]) was used to calculate the inter-rater reliability of the thickness measurement of TrA, IO and EO using the values from both the first and second examiner. In all three muscles, moderate to excellent reliability was found for all conditions (probe locations and measurement techniques) (ICC=.70~.97). In the PL1-TA condition, inter-rater reliability in the three muscle thicknesses was good to excellent (ICC=.85~.96). The reliability of all measurement conditions was excellent in IO (ICC=.95~.97). Therefore, the findings of this study suggest that TA can be applied to PL1 by clinicians and researchers in order to measure the thickness of abdominal muscles.

Diagnosis with Ultrasound for Rib Fractures in the Golf (골프 운동중 발생한 늑골 골절의 초음파 진단)

  • Lim, Che-Joon;Youn, Te-Hyun;An, Ki-Yong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.1
    • /
    • pp.50-54
    • /
    • 2008
  • Purpose: In most cases, the main cause of chest or back pain during playing golf is rib fractures. This kind of rib fractures can be easily overlooked in plain radiographs. The purpose of this article is to clarify the value of the ultrasound in detecting rib fractures. Materials and Methods: We compared the findings of chest-X rays (anteroposterior, left or right lateral, both oblique view) with those of the ultrasound in 56 patients between the ages of 20th & 60th who were diagnosed rib fractures. Their chief complaints were chest or back pain which developed during playing golf. The results were analyzed statistically. Results: Among 56 cases of rib fractures, 34 cases were diagnosed with initial X-rays. 51 cases were diagnosed with ultrasound. The sensitivity of radiograph and ultrasound were 60.71% & 91.07%, respectively. Dignosis was ultrasound with statical significance whereas radiography did not(p=0.0004). Conclusion: It was concluded that ultrasound is a valuable tool in the diagnosis of the rib fractures which were undetected with X-rays during playing golf.

  • PDF

Effect of Electrical Muscle Stimulation Belt for Abdominal Muscles Activation

  • Choi, Dayeong;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.4
    • /
    • pp.444-449
    • /
    • 2021
  • Objective: The purpose of this study is to observe the change in the thickness of abdominal muscles when electrical muscle stimulation (EMS) is applied to the abdomen during rest and abdominal muscle exercise to investigate the effect of EMS applied to the abdomen on the superficial and deep muscles thickness. Design: Cross sectional design. Methods: Twenty healthy subjects participated in this study. Subjects were performed resting position, resting position with EMS, curl-up and curl-up with EMS. The electrode of the EMS belt is attached to the abdominal wall between the 12th rib and iliac crest. The thickness of abdominal muscles including rectus abdominis (RA), external oblique (EO), internal oblique (IO), and transverse abdominis (TrA) were captured in each position by ultrasound image during expiration. All subjects were performed four positions randomly. Data were analyzed using repeated ANOVA with the level of significance set at 𝛼=0.05. Results: The muscle thickness of RA, EO, IO and TrA were significantly different at each position (p<0.05). The thickness of all abdominal muscles increased significantly when curl-up than curl-up with EMS. Both RA and EO thickness were significantly increased at resting position than resting position and EMS were combined(p<0.05). But IO and TrA thickness were decreased at resting position when EMS were combined. Conclusions: The results suggest that EMS activates superficial abdominal muscles RA and EO. Therefore, abdominal strengthening exercise combined EMS can activate abdominal muscles and can be applied to various patients and rehabilitation in clinical practice.

Detection of peri-implant bone defects using cone-beam computed tomography and digital periapical radiography with parallel and oblique projection

  • Saberi, Bardia Vadiati;Khosravifard, Negar;Ghandari, Farnaz;Hadinezhad, Arash
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.265-272
    • /
    • 2019
  • Purpose: To compare the diagnostic accuracy of cone-beam computed tomography (CBCT) with that of parallel(PPA) and oblique projected periapical(OPA) radiography for the detection of different types of peri-implant bone defects. Materials and Methods: Forty implants inserted into bovine rib blocks were used. Thirty had standardized bone defects(10 each of angular, fenestration, and dehiscence defects), and 10 were defect-free controls. CBCT, PPA, and OPA images of the samples were acquired. The images were evaluated twice by each of 2 blinded observers regarding the presence or absence and the type of the defects. The area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were determined for each radiographic technique. The 3 modalities were compared using the Fisher exact and chi-square tests, with P<0.05 considered as statistical significance. Results: High inter-examiner reliability was observed for the 3 techniques. Angular defects were detected with high sensitivity and specificity by all 3 modalities. CBCT and OPA showed similar AUC and sensitivity in the detection of fenestration defects. In the identification of dehiscence defects, CBCT showed the highest sensitivity, followed by OPA and PPA, respectively. CBCT and OPA had a significantly greater ability than PPA to detect fenestration and dehiscence defects(P<0.05). Conclusion: The application of OPA radiography in addition to routine PPA imaging as a radiographic follow-up method for dental implantation greatly enhances the visualization of fenestration and dehiscence defects. CBCT properly depicted all defect types studied, but it involves a relatively high dose of radiation and cost.

Intra- and Inter-rater Reliabilities of Infrasternal Angle Measurement

  • Kim, Moon-Hwan;Weon, Jong-Hyuck
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.3
    • /
    • pp.154-158
    • /
    • 2015
  • Purpose: The purpose of this study was to propose a new reference point for measurement of the infrasternal angle and to investigate the intra- and inter-rater reliabilities of infrasternal angle measurement using photographs. Methods: Twenty-four healthy male college students participated as subjects in this study. Photographs were taken of subjects in two postures, one standing with the shoulders relaxed and one standing with the shoulders at $150^{\circ}$ abduction. All photographs were analyzed using Image J software. Raters used the photographs to measure the infrasternal angle between the xiphoid process, the medial margin of rib and navel on the right and left sides. The reliability of the infrasternal angle measurement was assessed by means of intraclass correlation coefficients [ICC (3,1)]. The level of statistical significance was set at p<0.05. Results: The intra- and inter-rater reliabilities of the infrasternal angle measurement for the right side at rest were excellent (ICC=0.866 and 0.813, respectively), as were those for the left side at rest (ICC=0.919 and 0.846, respectively). At $150^{\circ}$ shoulder abduction, the intra- and inter-rater reliabilities for measurement of the infrasternal angle on the right side were excellent (ICC=0.972 and 0.778, respectively), as were those for the left side (ICC=0.914 and 0.826, respectively). Conclusion: These findings suggest that this technique can be successfully used to measure the infrasternal angle, thus suggesting a new reference point for determining the length of the internal oblique and external oblique muscles in clinical situations.

Shape Control using Piezoelectric Materials and Shape Memory Alloy (압전재료와 형상기억합금을 이용한 형상제어)

  • Park, H.C.;Hwang, W.;Oh, J.T.;Bae, S.M.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1311-1320
    • /
    • 2000
  • In this study, shape memory alloy(SMA) wires and piezoceramic actuators(PZT's) are employed in order to generate higher modes on the beam deformations. Compressive force is generated and applied to the beam by the pre-strained SMA wires attached at both ends of the beam. PZT's apply concentrated moments to several locations on the beam. Combinations of the compressive force and concentrated moments are investigated in order to understand the higher-mode deformation of beams. The first desired mode shape is obtained by controlling the temperature of the SMA wires. The first and third mode shapes are performed experimentally by heating SMA wires up to phase transformation temperature. The adaptive wing is defined as a wing whose shape parameters such as the camber, wing twist and thickness can be varied in order to change the wing shape for various flight conditions. In this research, control of the camber has been studied. The wing model consists of three plates and many ribs. Two of the plates are placed parallel to each other and they are clamped at one edge. Third plate connects the other edges of the parallel plates together. Each rib is made of SMA wire and connected to the parallel plates. It generates concentrated force and applies to the plates in oblique directions. The PZT's are bonded onto the plates and exert concentrated moments upon the plate at several locations. The object of this research is to generate various shape of wing by combining the concentrated forces and moments.

  • PDF