• Title/Summary/Keyword: Oblique Image

Search Result 137, Processing Time 0.023 seconds

Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever

  • Park, Ji-Man;Kim, Hyun-Joo;Park, Eun-Jin;Kim, Myung-Rae;Kim, Sun-Jong
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.361-371
    • /
    • 2014
  • PURPOSE. In case of large horizontal discrepancy of alveolar ridge due to severe resorption, cantilevered crown is usually an unavoidable treatment modality. The purpose of this study was to evaluate the clinical criteria for the placement of the aforementioned implant crown. MATERIALS AND METHODS. The mandible model with 2 mm thick cortical bone and cancellous bone was fabricated from CT cross-section image. An external connection type implant was installed and cantilevered crowns with increasing offset of 3, 4, 5, 6, and 7 mm were connected. Vertical load and $30^{\circ}$ oblique load of 300 N was applied and stress around bone and implant component was analyzed. A total of 14 cases were modeled and finite element analysis was performed using COSMOS Works (Solid works Inc, USA). RESULTS. As for the location of the vertical load, the maximum stress generated on the lingual side of the implant became larger according to the increase of offset distance. When the oblique load was applied at $30^{\circ}$, the maximum stress was generated on the buccal side and its magnitude gradually decreased as the distance of the offset load increased to 5 mm. After that point, the magnitude of implant component's stress increased gradually. CONCLUSION. The results of this study suggest that for the patient with atrophied alveolar ridge following the loss of molar teeth, von-Mises stress on implant components was the lowest under the $30^{\circ}$ oblique load at the 5 mm offset point. Further studies for the various crown height and numbers of occusal points are needed to generalize the conclusion of present study.

Reduction of Gamma Distortion in Oblique Viewing Directions in Polymer-stabilized Vertical Alignment Liquid Crystal Mode

  • Kim, Hyo Joong;Lim, Young Jin;Murali, G.;Kim, Min Su;Kim, Gi Heon;Kim, Yong Hae;Lee, Gi-Dong;Lee, Seung Hee
    • Current Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.157-162
    • /
    • 2017
  • In large liquid crystal displays, the image quality in an oblique viewing direction is a crucial issue. From this perspective, 8-domain polymer-stabilized vertical alignment (PS-VA) mode has been developed to suppress the color shift in oblique viewing directions, compared to that in 4-domain PS-VA mode. To realize the 8-domain PS-VA, the four domains in a pixel are each divided into two regions, such that applying different electric potentials result in different tilt angles in these two regions, while keeping four azimuthal directions in each domain. However, applying different voltages in a pixel causes drawbacks, such as requiring additional processes to construct a capacitor and a transistor, which will further reduce the aperture ratio. Here we propose a different approach to form the 8-domain, by controlling surface polar anchoring energy and the width of patterned electrodes in two regions of a pixel. As a result, the gamma-distortion index (GDI), measured at an azimuthal angle of $0^{\circ}$, is reduced by about 23% and 8%, compared to that of a conventional 4-domain at polar angles of $30^{\circ}$ and $60^{\circ}$ respectively.

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

The Measurement of the Depth of Crack using Images of SLAM (SLAM 영상을 이용한 크랙 깊이 측정)

  • Hwang, Ki-Hwan;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.51-56
    • /
    • 1997
  • In this paper, we studied the configuration and depth measurement method of the crack in the interior of solid with scanning laser acoustic microscope. Precision measurement method of crack depth is required in SLAM because that system reconstructs the shadow image to the transmission coefficient. We proposed this method that used geometrical structure to the shadow area of SLAM images obtained from oblique incidence and the mode conversion of ultrasound in specimen and then experimented it. For this experiment, we fabricated various specimens which had the vertical line-crack with different depth and made the wedge as 20$^{\circ}$ for oblique incidence. Experimental results showed that the shadow area of SLAM images were proportional to the depth of crack. Measured depth error to the crack was less than 6% compared with practical crack depth.

  • PDF

Effect of Electrical Muscle Stimulation Belt for Abdominal Muscles Activation

  • Choi, Dayeong;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.4
    • /
    • pp.444-449
    • /
    • 2021
  • Objective: The purpose of this study is to observe the change in the thickness of abdominal muscles when electrical muscle stimulation (EMS) is applied to the abdomen during rest and abdominal muscle exercise to investigate the effect of EMS applied to the abdomen on the superficial and deep muscles thickness. Design: Cross sectional design. Methods: Twenty healthy subjects participated in this study. Subjects were performed resting position, resting position with EMS, curl-up and curl-up with EMS. The electrode of the EMS belt is attached to the abdominal wall between the 12th rib and iliac crest. The thickness of abdominal muscles including rectus abdominis (RA), external oblique (EO), internal oblique (IO), and transverse abdominis (TrA) were captured in each position by ultrasound image during expiration. All subjects were performed four positions randomly. Data were analyzed using repeated ANOVA with the level of significance set at 𝛼=0.05. Results: The muscle thickness of RA, EO, IO and TrA were significantly different at each position (p<0.05). The thickness of all abdominal muscles increased significantly when curl-up than curl-up with EMS. Both RA and EO thickness were significantly increased at resting position than resting position and EMS were combined(p<0.05). But IO and TrA thickness were decreased at resting position when EMS were combined. Conclusions: The results suggest that EMS activates superficial abdominal muscles RA and EO. Therefore, abdominal strengthening exercise combined EMS can activate abdominal muscles and can be applied to various patients and rehabilitation in clinical practice.

Development of a Multi-View Camera System Prototype (다각사진촬영시스템 프로토타입 개발)

  • Park, Seon-Dong;Seo, Sang-Il;Yoon, Dong-Jin;Shin, Jin-Soo;Lee, Chang-No
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.2
    • /
    • pp.261-271
    • /
    • 2009
  • Due to the recent rise of a need for 3 dimensional geospatial information on urban areas, general interest in aerial multi-view cameras has been on an increase. The conventional geospatial information system depends solely upon vertical images, while the multi-view camera is capable of taking both vertical and oblique images taken from multiple directions, thus making it easier for the user to interpret the object. Through our research we developed a prototype of a multi-view camera system that includes a camera system, GPS/INS, a flight management system, and a control system. We also studied and experimented with the camera viewing angles, the synchronization of image capture, the exposure delay, the data storage that must be considered for the development of the multi-view camera system.

A Study on Necktie Image of Striped Pattern according to Area-Ratio Variation of Chromatic and Achromatic Colors (무채색과 유채색의 면적비 변와에 따른 스트라이프 패턴의 넥타이 이미지 연구)

  • Sung, Nam-Suk;Choi, Su-Koung
    • Journal of the Korean Society of Costume
    • /
    • v.59 no.4
    • /
    • pp.67-81
    • /
    • 2009
  • This study aims to characterize the effect of different combinations of chromatic-achromatic colors and 1:2:3 area-ratio variation of stripe necktie, and gender on the image of male wearer. The experimental materials developed for this study are a set of stimuli and response scales. The stimuli consist of 84 color pictures manipulated with every combination of 12 different colors and 7 different area-ratio. The 7-point scale designed for visual evaluation of image formation included 26 bipolar adjectives. The subjects were 2016 undergraduate students in Gyeongnam, Seoul, Busan, and Daegu areas. The results of this study were as follows. The analyses of images of male wearer in terms of combinations of chromatic-achromatic colors and I :2:3 area-ratio variation of oblique stripe necktie reveal that the concerned factors are of five characteristic dimensions of youth-activity, ability, attractiveness, appeal, and warmness. In addition, it has been found that individual images of male wearer are affected by observer's gender as well as combinations of chromatic-achromatic colors and 1:2:3 area-ratio variation of stripe neckties and that those images vary with every combination of each factor. The study results are highly expected to be used as useful sources in developing necktie designs.

Development of 3-D Stereo PIV and Its Application to a Delta Wing

  • Kim, Beom-Seok;Lee, Hyun;Choi, Jang-Woon;Kadooka, Yoshimasa;Tago, Yoshio;Lee, Young-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.658-663
    • /
    • 2003
  • A process of 3-D stereo particle image velocimetry(PIV)was developed for the measurement of an illuminated sliced section field of 3-D complex flows. The present method includes modeling of camera by a calibrator based on the homogeneous coordinate system, transformation of the oblique-angled image to the right-angled image, identification of 2-D velocity vectors by 2-D cross-correlation equation, stereo matching of 2-D velocity vectors of two cameras, accurate calculation of 3-D velocity vectors by homogeneous coordinate system, removal of error vectors by a statistical method followed by a continuity equation criteria, and finally 3-D display as the post processing. An experimental system was also used for the application of the proposed method. Two high speed digital CCD cameras and an Argon-Ion Laser for the illumination were adopted to clarify the time-dependent characteristics of the leading edge extension(LEX) in a highly swept shape applied to a delta wing found in modern air-fighters.

  • PDF

Algorithm for Discrimination of Brown Rice Kernels Using Machine Vision

  • C.S. Hwang;Noh, S.H.;Lee, J.W.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.823-833
    • /
    • 1996
  • An ultimate purpose of this study is to develop an automatic brown rice quality inspection system using image processing technique. In this study emphasis was put on developing an algorithm for discriminating the brown rice kernels depending on their external quality with a color image processing system equipped with an adaptor for magnifying the input image and optical fiber for oblique illumination. Primarily , geometrical and optical features of sample images were analyzed with unhulled paddy and various brown rice kernel samples such as sound, cracked, green-transparent , green-opaque, colored, white-opaque and brokens. Secondary, an algorithm for discrimination of the rice kernels in static state was developed on the basis of the geometrical and optical parameters screened by a statistical analysis(STEPWISE and DISCRIM Procedure, SAS ver.6). Brown rice samples could be discriminated by the algorithm developed in this study with an accuracy of 90% to 96% for the sound , cracked, colored, broken and unhulled , about 81% for the green-transparent and the white-opaque and about 75% for the green-opaque, respectively. A total computing time required for classification was about 100 seconds/1000 kernels with the PC 80486-DX2, 66MHz.

  • PDF

The Age Related Changes of Thickness and Symmetry of Deep Trunk Muscles (노화에 따른 심부 복부근육의 두께 변화와 대칭성 변화)

  • Seo, Dong-Kwon;Lee, Seung-Won
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.3
    • /
    • pp.379-385
    • /
    • 2013
  • PURPOSE: This study is research about deep trunk muscles (DTM) that is important and serve to control the movement of the trunk to provide stability during movement for human. In this study, trying to prove a change of DTM of aging in the ultrasound image. METHODS: We measured via an ultrasound image during rest and contraction of DTM in 42 young and 48 old people, and then we measured the change of thickness and symmetry. RESULTS: Symmetry showed a significant difference only external oblique (EO) in the young(p<.05). In the elderly, it was found that ratio of contraction was greater transverse abdominis than EO. CONCLUSION: I considered it could lead to improvement of activity of daily life by applying intervention for recovery of motor control of TrA for the elderly in clinical practice.