• Title/Summary/Keyword: Oblique Angle Images

Search Result 38, Processing Time 0.02 seconds

The Study of Grashey Method Viewing the Glenohumeral(shoulder) Joint (어깨관절의 접시오목을 나타내는 Grashey법에 대한 연구)

  • Lee, Jaeseob;Kim, Youngjae
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.331-335
    • /
    • 2015
  • Consideration of Glenohumeral joint's image with the Changed Body angle of the Glenohumeral joint's Oblique Position in Erect Position. Glenohumeral joint's of Grashey method is a shoulder oblique method available to view the shoulder joint. Grashey method projects AP view of the Glenohumeral joint's so that the Humerus head's subluxation or joint degeneration can be easily visualized. However in this view, the patients, erect position, have to keep their body obliquely. Oblique position is will be needed to get the good quality Glenohumeral joint's view. Therefore, we thought of examining a method which shows the Glenohumeral joint's well by angling the patient one side upward in erect position. For this study, total 20 subject with no history of neurological or psychiatric illness, were recruited for examinations. They consisted of 13 mails and 7 femails, Statistic group analysis was performed with ANOVA test. Score of the evaluation of the expects were $30^{\circ}$ at $0.40{\pm}0.499$, $35^{\circ}$ at $1.34{\pm}0.657$, $40^{\circ}$ at $1.84{\pm}0.573$, $45^{\circ}$ at $0.76{\pm}0.649$, and they were significant(P<0.05). The degree of $40^{\circ}$ views were shown to yield good quality shoulder oblique images.

Inter-Rater Reliability of Abdominal Muscles Thickness Using Ultrasonography for Different Probe Locations and Thickness Measurement Techniques

  • Lim, One-Bin;Hong, Ji-A;Yi, Chung-Hwi;Cynn, Heon-Seock;Jung, Doh-Heon;Park, Il-Woo
    • Physical Therapy Korea
    • /
    • v.18 no.4
    • /
    • pp.60-67
    • /
    • 2011
  • Ultrasonography (US) is a recent technique that has proven to be useful for assessing muscle thickness and guiding the rehabilitation decision-making of clinicians and researchers. The purpose of this study was to determine the inter-rater reliability of the US measurement of transversus abdominis (TrA), internal oblique (IO), and external oblique (EO) thicknesses for different probe locations and measurement techniques. Twenty healthy volunteers were recruited in this study. Muscle thicknesses of the transversus TrA, IO, and EO were measured three times in the hook-lying position. The three different probe locations were as follows: 1) Probe location 1 (PL1) was below the rib cage in direct vertical alignment with the anterior superior iliac spine (ASIS). 2) Probe location 2 (PL2) was halfway between the ASIS and the ribcage along the mid-axillary line. 3) Probe location 3 (PL3) was halfway between the iliac crest and the inferior angle of the rib cage, with adjustment to ensure the medial edge of the TrA. The two different techniques of thickness measurement from the captured images were as follows: 1) Muscle thickness was measured in the middle of the muscle belly, which was centered within the captured image (technique A; TA). 2) Muscle thickness was measured along a horizontal reference line located 2 cm apart from the medial edge of the TrA in the captured image (technique B; TB). The intraclass correlation coefficient (ICC [3,k]) was used to calculate the inter-rater reliability of the thickness measurement of TrA, IO and EO using the values from both the first and second examiner. In all three muscles, moderate to excellent reliability was found for all conditions (probe locations and measurement techniques) (ICC=.70~.97). In the PL1-TA condition, inter-rater reliability in the three muscle thicknesses was good to excellent (ICC=.85~.96). The reliability of all measurement conditions was excellent in IO (ICC=.95~.97). Therefore, the findings of this study suggest that TA can be applied to PL1 by clinicians and researchers in order to measure the thickness of abdominal muscles.

VISUALIZATION AND MEASUREMENT OF A NARROW-CONE DI GASOLINE SPRAY FOR THE IMPINGEMENT ANALYSIS

  • Park, J.S.;Im, K.S.;Kim, H.S.;Lai, M.C.
    • International Journal of Automotive Technology
    • /
    • v.5 no.4
    • /
    • pp.221-238
    • /
    • 2004
  • Wall interactions of direct injection spray were investigated using laser-sheet imaging, shadowgraphy, wetted footprint and phase Doppler interferometry techniques. A narrow-cone high-pressure swirl injector is used to inject iso-octane fuel onto a plate, which has three different impact angles inside a pressurized chamber. Heated air and plate conditions were compared with unheated cases. Injection interval was also varied in the heated case to compare dry- and wet- wall impingement behaviors. High-speed macroscopic Mie-scattering images showed that presence of wall and air temperature has only minor effect on the bulk spray structure and penetration speed for the narrow-cone injector tested. The overall bulk motions of the spray plume and its spatial position at a given time are basically unaffected until a few millimeters before impacting the wall. The surface properties of the impact surface, such as the temperature, the presence of a preexisting liquid film also have a small effect on the amount of wetting or the wetted footprint; however, they have strong influence on what occurs just after impact or after a film is formed. The shadowgraph in particular shows that the plate temperature has a significant effect on vapor phase propagation. Generally, 10-20% faster horizontal vapor phase propagation is observed along the wall at elevated temperature condition. For impingement onto a preexisting film, more splash and evaporation were also observed. Contrary to some preconceptions, there is no significant splashing and droplet rebounding from surfaces that are interposed in the path of the DI gasoline spray, especially for the oblique impact angle cases. There also appears to be a dense spray front consists of large sac spray droplets in the oblique impact angle cases. The bulk of the spray is not impacted on the surface, but rather is deflected by it The microscopic details as depicted by phase Doppler measurements show that the outcome of the droplet impaction events can be significantly influenced. Only droplets at the spray front have high enough Weber numbers for wall impact to wet, splash or rebound. Using the sign of vertical velocity, the time-resolved downward droplets and upward droplets are compared. The Weber number of upward moving droplets, which seldom exceeds unity, also decreases as the impact angle decreases, as the droplets tend to impact less and move along the wall in the deflected spray plume.

A Simulation Tool for Ultrasonic Inspection

  • Krishnamurthy, Adarsh;Mohan, K.V.;Karthikeyan, Soumya;Krishnamurthy, C.V.;Balasubramaniam, Krishnan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.3
    • /
    • pp.153-161
    • /
    • 2006
  • A simulation program SIMULTSONIC is under development at CNDE to help determine and/or help optimize ultrasonic probe locations for inspection of complex components. SIMULTSONIC provides a ray-trace based assessment for immersion and contact modes of inspection. The code written in Visual C++ operating in Microsoft Windows environment provides an interactive user interface. In this paper, a description of the various features of SIMULTSONIC is given followed by examples illustrating the capability of SIMULTSONIC to deal with inspection of canonical objects such as pipes. In particular, the use of SIMULTSONIC in the inspection of very thin-walled pipes (with 450 urn wall thickness) is described. Ray trace based assessment was done using SIMULTSONIC to determine the standoff distance and the angle of oblique incidence for an immersion mode focused transducer. A 3-cycle Hanning window pulse was chosen for simulations. Experiments were carried out to validate the simulations. The A-scans and the associated B-Scan images obtained through simulations show good correlation with experimental results, both with the arrival time of the signal as well as with the signal amplitudes.

Effect of Cage in Radiological Differences between Direct and Oblique Lateral Interbody Fusion Techniques

  • Ko, Myeong Jin;Park, Seung Won;Kim, Young Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.432-441
    • /
    • 2019
  • Objective : Few studies have reported direct comparative data of lumbar spine angles between direct lateral interbody fusion (DLIF) and oblique lateral interbody fusion (OLIF). The purpose of this study was to investigate the clinical and radiological outcomes of DLIF and OLIF, and determine influential factors. Methods : The same surgeon performed DLIF from May 2011 to August 2014 (n=201) and OLIF from September 2014 to September 2016 (n=142). Radiological parameters, cage height, cage angle (CA), cage width (CW), and cage location were assessed. We checked the cage location as the distance (mm) from the anterior margin of the disc space to the anterior metallic indicator of the cage in lateral images. Results : There were significant differences in intervertebral foramen height (FH; $22.0{\pm}2.4$ vs. $21.0{\pm}2.1mm$, p<0.001) and sagittal disc angle (SDA; $8.7{\pm}3.3$ vs. $11.3{\pm}3.2^{\circ}$, p<0.001) between the DLIF and OLIF groups at 7 days postoperatively. CA ($9.6{\pm}3.0$ vs. $8.1{\pm}2.9^{\circ}$, p<0.001) and CW ($21.2{\pm}1.6$ vs. $19.2{\pm}1.9mm$, p<0.001) were significantly larger in the OLIF group compared to the DLIF group. The cage location of the OLIF group was significantly more anterior than the DLIF group ($6.7{\pm}3.0$ vs. $9.1{\pm}3.6mm$, p<0.001). Cage subsidence at 1 year postoperatively was significantly worse in the DLIF group compared to the OLIF group ($1.0{\pm}1.5$ vs. $0.4{\pm}1.1mm$, p=0.001). Cage location was significantly correlated with postoperative FH (${\beta}=0.273$, p<0.001) and postoperative SDA (${\beta}=-0.358$, p<0.001). CA was significantly correlated with postoperative FH (${\beta}=-0.139$, p=0.044) and postoperative SDA (${\beta}=0.236$, p=0.001). Cage location (${\beta}=0.293$, p<0.001) and CW (${\beta}=-0.225$, p<0.001) were significantly correlated with cage subsidence. Conclusion : The cage location, CA, and CW seem to be important factors which result in the different-radiological outcomes between DLIF and OLIF.

The shoulder diagnosis Scapula study of patients who visited the hospital (병원 내원한 환자 견갑골(scapula) 진단을 위한 연구)

  • Ahn, Byeong-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.13-20
    • /
    • 2010
  • True lateral scapula image was very important to diagnosis the scapula fracture and dislocation induced by traumatic injury. The aim of this study was to know the patient rotation angle to be showing the scapula true lateral in korean. d Materials Thirty patients(22men, 8 women, mean ages 53.4)with scapular pain, had supine Anteroposterior projection taken with $30^{\circ}$, $40^{\circ}$, $45^{\circ}$ trunk rotation angle changing the manual angulation material. Radiographs were evaluated independently by 5 experienced observers(1 orthopedics surgery specialist, 1 diagnostic radiology specialist, 3 radiological technologist) They assessed overlap of vertebral border and axillary border of scapula as follows; Totally overlapping of vertebral border and axillary border is 4, partially overlapping is 3, not overlapping is 2 and oblique location with two borders is 1. All observers scored using by PACS monitor.$30^{\circ}$ trunk rotation was scored $1.53{\pm}0.39$, $40^{\circ}$ trunk rotation was scored $3.83{\pm}0.15$ and $45^{\circ}$ trunk rotation was scored $2.17{\pm}0.43$. There was no difference(p<0.05) between group of more than 100cm of the girth of the chest and group of less than 100cm. Similarly, men and women group showed no difference(p<0.05) with trunk rotation statistically. There was no result of trunk rotation angle to radiograph the true scapula lateral image up to date. This studies were summarized as follows; Adaptation of $40^{\circ}$ trunk rotation was the best to show the true scapula lateral image in korean. Our results were very useful to get the true scapula lateral images in clinic.

A NEW MEASUREMENT METHOD OF FEMORAL ANTEVERSION BASED ON THREE DIMENSIONAL MODELING (3차원 모델링을 이용한 대퇴 전염각의 측정)

  • Kim, June-S.;Park, Hee-J.;Choi, Kwang-S.;Choi, Kui-W.;Kim, Sun-I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.141-144
    • /
    • 1997
  • Femoral neck anteversion is the angle between the neck and the knee axis projected on a plane perpendicular to the longitudinal axis. Conventional methods that use cross-sectional Computed Tomography(CT) images to estimate femoral anteversion have several problems because of the complex 3D structure of the femur. These are the ambiguity of defining the longitudinal axis, the femoral neck axis and condylar line, and the dependence on patient positioning. Especially the femoral neck axis that is known as a major source of error is hard to determine from a single or multiple 2D transverse images. So we developed a new method for measuring femoral anteversion by 3D modeling method. In this method, femoral head is modeled as a sphere. The center of femoral neck is the mid-point of the 2D reconstructed oblique image in the femoral neck part. Then neck axis is a line connecting foregoing two centers. We model the longitude of femur as a cylinder, and the long axis is defined from the fitted cylinder. The knee axis which is tangent to the back of the femoral condyles is easily determined by table-top method. By the definition of femoral anteversion, the femoral anteversion is easily calculated from this model.

  • PDF

Evaluation of usefulness for Stereotactic Partial Breast Irradiation(S-PBI) by using Surface Fiducial Marker (표면위치표지자를 적용한 정위적 부분유방방사선치료의 유용성 평가)

  • Kim, JongYeol;Jung, DongMin;Kim, SeYoung;Yoo, HyunJong;Choi, JungHoan;Park, HyoKuk;Baek, JongGeol;Lee, SangKyu;Cho, JeongHee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.99-108
    • /
    • 2021
  • Purpose: The goal of this study is to evaluate usefulness of noninvasive method instead of previous inserting Fiducial Marker Method when performing Stereotactic Partial Breast Irradiation in CyberKnife. Material and methods: For consistency of Imaging Center, we evaluated both oblique images at angle 45 and 315 acquired from 2D Simulator and CyberKnife quantitatively through dice similarity coefficient. Also, location reproducibility of Surface Fiducial Marker was analyzed from 2D Simulator, treatment plans and CyberKinfe images by using 8 Fiducial Markers made of gold attached to ATOM Phantom based on our institution's protocols. Results: The results of the estimated consistency were 0.87 and 0.9 at the oblique angle 45 and 315, respectively. For location consistency of Surface Fiducial Markers, values of horizontal vertical direction of left breast were Superior/Inferior 0.3 mm, Left/Right -0.3 mm, Anterior/Posterior 0.4 mm, and the values of rotational direction were Roll 0.3 °, Pitch 0.2 °, Yaw 0.4 °. The values of horizontal vertical direction of right breast were Superior/Inferior -0.1 mm, Left/Right -0.1 mm, Anterior/Posterior -0.1 mm, and the values of rotational direction were Roll 0.2°, Pitch 0.1°, Yaw 0.1°. Conclusions: We expect that the protocols used by Surface Fiducial Markers when performing Stereotactic Partial Breast Irradiation in CyberKnife will provide protection from pain and cut expenses for treatment and reduce treatment errors and make treatment more accurate by suggesting treatment protocols based on high consistency of Imaging Center and reproducibility of Fiducial Markers.

The Comparison of Quantitative Indices by Changing an Angle of LAO View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 좌전사위상 각도의 변화에 따른 정량적 지표 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Ryu, Jae-Kwang;Kim, Seong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.57-61
    • /
    • 2012
  • Purpose: The multi-gated cardiac blood pool scan is to evaluate the function of left ventricle (LV) and usefully observe a value of ejection fraction (EF) for a patient who is receiving chemotherapy. To calculate LVEF, we should adjust an angle of left anterior oblique (LAO) view to separate both ventricles. And by overlapped ventricles, it is possible to affect LVEF. The purpose of this study is to investigate and compare quantitative indices by changing an angle of LAO view. Materials and methods: We analyzed the 49 patients who were examined by multi-gated cardiac blood pool scan in department of nuclear medicine at Asan Medical Center from June to September 2011. Firstly, we acquired "Best septal" view. And then, we got images by addition and subtraction of angle for LAO view to anterior and lateral. We compared three LAO views for 20 people by 5 degrees and 39 people by 10 degrees. And we analyzed quantitative indices, EF, end diastole and end systole counts, by automated and manual region of interest (ROI) modes. Results: Firstly, we analyzed quantitative indices by automated ROI mode. In case of 5 degrees, the averages of EF are $61.0{\pm}7.5$, $62.1{\pm}7.1$, $60.9{\pm}6.7%$ ($p$=0.841) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $62.4{\pm}9.5$, $62.3{\pm}10.8$, $61.6{\pm}.9.3%$ ($p$=0.938) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Secondly, we analyzed quantitative indices by manual ROI mode. In case of 5 degrees, the averages of EF are $62.8{\pm}7.1$, $63.6{\pm}7.5$, $62.7{\pm}7.3%$ ($p$=0.903) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $65.5{\pm}9.0$, $66.3{\pm}8.7$, $63.5{\pm}.9.3%$ (p=0.473) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Conclusion: When an image is nearly "Best septal" view, the difference of LAO angle would not affect to change LVEF. Although there was no difference in quantitative analysis, deviations could happen when to interpret wall motion qualitatively by reading physicians.

  • PDF

A Study on Point Cloud Generation Method from UAV Image Using Incremental Bundle Adjustment and Stereo Image Matching Technique (Incremental Bundle Adjustment와 스테레오 영상 정합 기법을 적용한 무인항공기 영상에서의 포인트 클라우드 생성방안 연구)

  • Rhee, Sooahm;Hwang, Yunhyuk;Kim, Soohyeon
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_1
    • /
    • pp.941-951
    • /
    • 2018
  • Utilization and demand of UAV (unmanned aerial vehicle) for the generation of 3D city model are increasing. In this study, we performed an experiment to adjustment position/orientation of UAV with incomplete attitude information and to extract point cloud data. In order to correct the attitude of the UAV, the rotation angle was calculated by using the continuous position information of UAV movements. Based on this, the corrected position/orientation information was obtained by applying IBA (Incremental Bundle Adjustment) based on photogrammetry. Each pair was transformed into an epipolar image, and the MDR (Multi-Dimensional Relaxation) technique was applied to obtain high precision DSM. Each extracted pair is aggregated and output in the form of a single point cloud or DSM. Using the DJI inspire1 and Phantom4 images, we can confirm that the point cloud can be extracted which expresses the railing of the building clearly. In the future, research will be conducted on improving the matching performance and establishing sensor models of oblique images. After that, we will continue the image processing technology for the generation of the 3D city model through the study of the extraction of 3D cloud It should be developed.