• Title/Summary/Keyword: OIML

Search Result 8, Processing Time 0.023 seconds

On OIML Mixed Acceptance Sampling Plans and Optimal Target Value for Products in Prepackages (OIML 혼합 샘플링 검사계획에 대한 고찰과 최적 목표값의 설정 : 실량표시상품을 대상으로)

  • Seo, Sun-Keun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.41 no.1
    • /
    • pp.17-24
    • /
    • 2015
  • Mixed acceptance sampling plans for quantity of products in prepackages are widely used for compliance testing. To pass testing, random samples jointly comply with two legal requirements: (i) the average net content of an inspection lot shall be not less than the labelled quantity and (ii) the numbers of under-filled prepackages in a sample are less than or equal to permitted numbers. This paper discusses some drawbacks of the acceptance sampling plans and requirements recommended in OIML R87 (KS A 50087 translated by Korean) developed by the International Organization of Legal Metrology and evaluates the producer's and consumer's risks. In addition, problem of determining a target value in filling processes of prepackages under the OIML R87 requirements is addressed and illustrated with a numerical example.

Quality Assessment of Domestic Non-automatic Weighing Instruments for International Standards (국제표준에 대비한 국내 비자동저울의 품질평가에 관한 연구)

  • Namkoong Chai-Kwan;Kong Jae Hyang
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.6
    • /
    • pp.127-134
    • /
    • 2004
  • As the result of reduction of the barrier of national economy on matters of quality assurance of weighing instruments in recently, it is considering in domestic as well as international matters. Therefore, this study is to analysis and compare with international md national measuring standards on the electric self-indicating scale, to improve the quality of electronic machine by providing a reformation plan on currently problems of domestic manufactured, and to identify to introduce in domestic criteria from international standards. I had compared KSC 1313 to OIML R 76-1 as the performance assessment items, such as metrology Properties test, static temperature test, temperature effect testing under the un-load, electronic wave disturbance test, high-tempereature and high-humidity stability test and durability test. Therefore, only one company is passed all items of the test according to the international (reference) standards, but it is possible to improve the quality in general if it should be use the load cell and electric components which is stability of temperature change in order to supplementation to the static temperature test and temperature effect testing under the un-load. It is also possible to apply in the domestic with the OIML 76-1 after correcting the design.

Concentration of water flow to improve flowmeter accuracy and International Performance Standards (Q2/Q1) 1.6multiple Correlation of Reliability Securing (유량계측 정확도 향상을 위한 유로집중과 국제성능기준 전이유량비(Q2/Q1)1.6배수 신뢰성 확보의 상관관계)

  • Seo, Man Je
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.237-237
    • /
    • 2020
  • 수도계량기(이하 "수량계")는 액체용 적산부피계로 물 사용량을 적산 계량하기 위한 기계기구 또는 장치이며 수량계 검정기준에 의해 검사기준 합격제품을 사용하서 수도요금을 징수합니다. 사실상 국내계량에 관한 법률에 의거하여 전이유량비가 6.3배수(2014년) > 4.0배수(2016년) > 1.6배수(2017년)로 점점 향상되며 2017년 기준으로 국제법정계량기구(OIML)의 성능과 같은 1.6배수까지 향상되어 국내의 수량계 기술기준이 많은 부분 향상되었습니다. 그러나 국제법정계량기구(OIML)는 현재 1.6배수의 80배수까지 검사기준에 합격에 반하여 현제 국내의 검사기준은 1.6배수의 100배수까지만 합격기준을 가지고 있습니다. 이러한 기준은 점차 발전해가고 있는 후발국가에 속하는 자국의 검사기준이 너무 갑작스럽게 국제법정계량기구(OIML)의 기준보다 높은 검사기준을 시행하며 많은 문제가 발생한 것 같습니다. 위와 같은 문제를 해결하기 위하여 여러 복합적인 부품으로 이루어진 수량계의 유량 및 유속에 영향력이 있다고 보여지는 특정 부품 혹은 부위의 개선 및 개발로 해결할 수 있지 않을까 하는 의구심에 연구를 시작되었습니다. 유량 및 유속에 영향을 끼치는 유입부의 스트레이너, 내부 임펠러의 변경으로 성능검사에서 영향을 끼치는지를 유체역학 및 유동해석 등을 통하여 테스트 후 각각 단계 및 상황별 목업금형을 제작하여 현재 국내검사기준으로 진행되는 성능테스트인 기차테스트를 진행하였습니다. 먼저 수량계의 특성상 수량계 내부의 유량을 유체역학 및 유동해석으로 정확히 뽑아내는 것이 불가능하여 유입부 유출부의 유량의 흐름을 기준으로 유체역학 및 유동해석을 진행하였습니다. 테스트 후 그 결과 값으로 유입부의 스트레이너의 삽입 각도를 0°, 90°, 135°, 180°, 270°로 각각 제작하여 테스트를 진행하였으며, 내부 임펠러는 straight, SR, SL, SL R70, SL R60, R75, SR R65 형상으로 각각 제작하여 테스트를 진행하였습니다. 전반적으로 기존의 수량계보다 높은 성능을 보여주었으며, 특정 스트레이너의 삽입각도 및 임펠러의 형상에서는 기존보다 훨씬 유수율이 절감되는 결과값이 나왔습니다. 그로 인해 검사기준에 쉽게 부합할 수 있으며 물 사용량을 보다 정확히 계측하여 정확한 수도요금을 부과하여 국세 낭비로 인한 경제적 손실을 감소할 수 있을 것 같습니다.

  • PDF

Quality Assesment of Domestic Nonautomatic Weighing Instruments by International Standards (국제기준에 의한 국내 비자동저울의 품질 평가에 관한 연구)

  • 김홍원;남궁재관;김창열;공재향
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.263-268
    • /
    • 2004
  • This study is to improve the quality of electronic weighing machine by providing a reformation plan on currently problems of domestic manufactured nonautomatic weighing instruments, and by test items and criteria considering internal situation on base of identification of quality level of domestic manufactures electronic weighing machine according to the international standards.

  • PDF

Analysis of Performance comparision of nonautomatic weighing instruments (비자동저울의 성능비교 분석에 관한 연구)

  • 남궁재관;김홍원;공재향
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.3-8
    • /
    • 2003
  • This study is to improve the quality of electronic weighing machine by providing a reformation plan on currently problems of domestic manufactured nonautomatic weighing instruments, and by test items and criteria considering internal situation, on base of identification of quality level of domestic manufactures electronic weighing machine according to the international standards.

  • PDF

The Apparent Strains of Strain Gages in Cryogenic Environment (극저온 환경에서 스트레인 게이지의 겉보기 변형률 특성에 관한 연구)

  • 주진원;김갑순
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.6
    • /
    • pp.1099-1107
    • /
    • 1992
  • The apparent strain of temperature self-compensated strain gages at cryogenic temperature is presented. By joining the international round robin test on electrical strain gages at cryogenic temperatures, apparent strain curves of up to the fourth order with respect to the temperature are obtained with different strain gages and different materials. The liquid nitrogen and the liquid helium are employed to get the cryogenic environment. The results can be effectively utilized to determine the real strains by mechanical loading at cryogenic temperature. This paper also describes the optimal selection of strain gages and test materials for the use of strain gages at cryogenic temperature.

Development of monitoring system and quantitative confirmation device technology to prevent counterfeiting and falsification of meters (주유기 유량 변조방지를 위한 주유기 엔코더 신호 펄스 파형 모니터링 및 정량확인 시스템 개발)

  • Park, Kyu-Bag;Lee, Jeong-Woo;Lim, Dong-Wook;Kim, Ji-hun;Park, Jung-Rae;Ha, Seok-Jae
    • Design & Manufacturing
    • /
    • v.16 no.1
    • /
    • pp.55-61
    • /
    • 2022
  • As meters become digital and smart, energy data such as electricity, gas, heat, and water can be accurately and efficiently measured with a smart meter, providing consumers with data on energy used, so that real-time demand response and energy management services can be utilized. Although it is developing from a simple metering system to a smart metering industry to create a high value-added industry fused with ICT, illegal counterfeiting of electronic meters is causing problems in intelligent crimes such as manipulation and hacking of SW. The meter not only allows forgery of the meter data through arbitrary manipulation of the SW, but also leaves a fatal error in the metering performance, so that the OIML requires the validation of the SW from the authorized institution. In order to solve this problem, a quantitative confirmation device was developed in order to eradicate the act of cheating the fuel oil quantity through encoder pulse operation and program modulation, etc. In order to prevent the act of deceiving the lubricator, a device capable of checking pulse forgery was developed, manufactured, and verified. In addition, the performance of the device was verified by conducting an experiment on the meter being used in the actual field. It is judged that the developed quantitative confirmation device can be applied to other flow meters other than lubricators, and in this case, accurate measurement can be induced.