• Title/Summary/Keyword: OAR

Search Result 119, Processing Time 0.021 seconds

Genetic Differentiation between Sheep and Goats Based on Microsatellite DNA

  • Sun, W.;Chang, H.;Ren, Z.J.;Yang, Z.P.;Geng, R.Q.;Lu, S.X.;Du, L.;Tsunoda, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.5
    • /
    • pp.583-587
    • /
    • 2004
  • The 7 sheep microsatellite markersOarFCB48, OarAE101, MAF33, OarFCB11, MAF70, OarFCB304 and OarFCB128, which were located on chromosomes 2, 4, 6, 9, 17 and 19, were selected to PCR in Hu sheep, Tong sheep and their closely related species,the goat. They were studied with the amplifying result of 7 microsatellite sites of Hu Sheep, Tong Sheep and goats, the data of allele number and range of allele' size of amplifying were analyzed with ANOVA. The results showed that there were no significant differences (p<0.05) in microsatellite DNA sites among 3 populations. Concerning the conservation of microsatellites in closely related species, selecting microsatellite sites located on the chromosome where the Robertsonian fusion was caused between sheep and goat, may be used in research into genetic differentiation and evolutionary relationships between sheep and goats.

Measurement of Dose Distribution in Small Fields of NEC LINAC 6 MVX Using Films and Tissue Equivalent Phantoms (필름 및 tissue equivalent 팬톰을 이용한 NEC LINAC 6 MVX 소조사면에 대한 선량분포 측정)

  • Suh, Tae-Suk;Park, Dong-Rak;Choe, Bo-Young;Yoon, Sei-Chul;Jang, Hong-Seok;Park, Il-Bong;Kim, Moon-Chan;Bahk, Yong-Whee;Shin, Kyung-Sub
    • Progress in Medical Physics
    • /
    • v.4 no.2
    • /
    • pp.9-17
    • /
    • 1993
  • The purpose of this paper is to develop a simple system to measure dose distribution in small fields of NEC LINAC 6 MVX using film and solid water instead of ion chamber and water phantom. Specific quantities measured include percent depth dose (PDD), off-axis ratio (OAR). We produced square fields of 1 to 3cm in perimeter in 1cm steps measured at SAD of 80cm. The PDD and OAR measured by film was compared with measurement made with ion chamber. We calculated the TMR from the basic PDD data using the conversion formula. The trends of our measured beam data and philips LINAC are similar each other. The measurement for the small field using film and solid water was simple. Hand-made film phantom was especially useful to measure OARs for the stereotactic radiosurgery.

  • PDF

The study of detector condition proper to the measurement of 6MV small x-rays beam (6MV 소형 x-선 beam 측정에 적합한 검출기의 조건에 관한 연구)

  • Yoo, Myung-Jin;Doh, Shin-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.219-225
    • /
    • 1999
  • The purpose of this study is to measure such parameters as TMR, OAR, TSF for small beams ranging in size from 12.5mm to 40mm by diode, ionization chamber, film, TLD and to determine proper detectors for the measurement of 6MV small x-ray beams. Diode and film show good results within 2% error for the TMR measurement of the beam as small as beam with diameter 12.5mm. Diode and film have excellent spatial resolution in the OAR measurement and the comparison between two detectors shows the error within 3%. But TMR and OAR can not be measured accurately by the ionization chambers. The TSF by diode and TLD records 0.890.96 for the beams with diameter 12.5mm 40mm. The TSF determined by 0.125cc ionization chamber and markus ionization chamber for the larger beams than the beams with diameter 25mm agrees within 2% comparing with that of diode and TLD.

  • PDF

A Study on Dosimetry for Small Fields of Photon Beam (광자선 소조사면의 선량 측정에 관한 연구)

  • 강위생;하성환;박찬일
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.57-68
    • /
    • 1994
  • Purpose : The purposes are to discuss the reason to measure dose distributions of circular small fields for stereotactic radiosurgery based on medical linear accelerator, finding of beam axis, and considering points on dosimetry using home-made small water phantom, and to report dosimetric results of 10MV X-ray of Clinac-18, like as TMR, OAR and field size factor required for treatment planning. Method and material : Dose-response linearity and dose-rate dependence of a p-type silicon (Si) diode, of which size and sensitivity are proper for small field dosimetry, are determined by means of measurement. Two water tanks being same in shape and size, with internal dimension, 30${\times}$30${\times}$30cm$^3$ were home-made with acrylic plates and connected by a hose. One of them a used as a water phantom and the other as a device to control depth of the Si detector in the phantom. Two orthogonal dose profiles at a specified depth were used to determine beam axis. TMR's of 4 circular cones, 10, 20, 30 and 40mm at 100cm SAD were measured, and OAR's of them were measured at 4 depths, d$\sub$max/, 6, 10, 15cm at 100cm SCD. Field size factor (FSF) defined by the ratio of D$\sub$max/ of a given cone at SAD to MU were also measured. Result : The dose-response linearity of the Si detector was almost perfect. Its sensitivity decreased with increasing dose rate but stable for high dose rate like as 100MU/min and higher even though dose out of field could be a little bit overestimated because of low dose rate. Method determining beam axis by two orthogonal profiles was simple and gave 0.05mm accuracy. Adjustment of depth of the detector in a water phantom by insertion and remove of some acryl pates under an auxiliary water tank was also simple and accurate. TMR, OAR and FSF measured by Si detector were sufficiently accurate for application to treatment planning of linac-based stereotactic radiosurgery. OAR in field was nearly independent of depth. Conclusion : The Si detector was appropriate for dosimetry of small circular fields for linac-based stereotactic radiosurgery. The beam axis could be determined by two orthogonal dose profiles. The adjustment of depth of the detector in water was possible by addition or removal of some acryl plates under the auxiliary water tank and simple. TMR, OAR and FSF were accurate enough to apply to stereotactic radiosurgery planning. OAR data at one depth are sufficient for radiosurgery planning.

  • PDF

Small Field Dosimetry for Stereotacitc Radiosurgery (뇌정위적 방사전수술을 위한 소조사면 측정)

  • 최동락;안용찬;이정일;허승재
    • Progress in Medical Physics
    • /
    • v.6 no.1
    • /
    • pp.59-64
    • /
    • 1995
  • The aim of presentation is to obtain the beam parameters for tratment planning of steretactic radiosurgery. The dosimerical parameters such as TMR, scatter factor, and OAR was measured using diode, film, micro ion chamber, and thimble chanber for water phantom scanning. The results were compared each other. As a result, we determined OAR from film and scatter factor and TMR from diode as a basic data for treatment planning.

  • PDF

Verification of Clinical Usefulness of Jaw Tracking in IMRT (IMRT에 있어 Jaw Tracking 의 임상적 유용성 검증)

  • Kim, Jin-young;Kim, Ki-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.105-109
    • /
    • 2020
  • Intensity-modulated radiotherapy(IMRT) has disadvantages such as increasing the low doses of irradiation to normal tissues and accumulated dose for the whole volume by leakage and transmission of the Multi Leaf Collimator (MLC). The accumulated dose and low dose may increase the occurrence of secondary malignant neoplasms. For this reasons, the jaw tracking function of the TrueBeam (Varian Medical Systems, Palo Alto, CA) was developed to reduce the leakage and transmission dose of the MLC with existing linear accelerators. But quantitative analysis of the dose reduction has not been verified. Therefore, in the present study, we intended to verify the clinical possibility of utilizing the jaw tracking function in brain tumor with comparison of treatment plans. To accomplish this, 3 types of original treatment plans were made using Eclipse11 (Varian Medical Systems, Palo Alto, CA): 1) beyond 2 cm distance from the Organs At Risk (OARs); 2) within 2 cm distance from the OARs; and 3) intersecting with the OARs. Jaw tracking treatment plans were also made with copies of the original treatment planning using Smart LMC Version 11.0.31 (Varian Medical Systems, Palo Alto, CA). A comparison between the 2 types of treatment planning methods was performed using the difference of the mean dose and maximum dose to the OARs in cumulative Dose Volume Histogram (DVH). In the DVH comparison, the maximum difference of 0.5 % was observed between the planning methods in the case of over 2 cm distance, and the maximum of 0.6 % was obtained for within the 2 cm distance. For the case intersecting with the OAR, the maximum difference of 2 % was achieved. According to these results, it could be realized that the differences of mean dose and maximum dose to the OARs was larger when the OARs and PTV were closer. Therefore, treatment plans with the jaw tracking function consistently affected the dose reduction and the clinical possibility could be verified.

The Dosimetric Effect on Real PTV and OARs at Various Image Fusion Protocol for Pituitary Adenomas (뇌하수체 종양의 방사선 수술 시 영상 융합 프로토콜이 실제 PTV와 OAR 선량에 미치는 영향)

  • Lee, Kyung-Nam;Lee, Dong-Joon;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.354-359
    • /
    • 2010
  • The purpose of this study is to verify the dosimetric effect on real PTV (planning target volume) coverage and safety of OARs (organs at risk) at various image fusion protocol-based radiosurgery plan for pituitary adenomas. Real PTV coverage and its variation was acquired and maximum dose and the volume absorbing above threshold dose were also measured for verifying the safety of optic pathway and brainstem. The protocol that can reduce superior-inferior uncertainty by using both axial and coronal MR (magnetic resonance) image sets shows relatively lower values than that of case using only axial image sets. As a result, the image fusion protocol with both axial and coronal image sets can be beneficial to generate OAR-weighted radiosurgery plan.

A Comparison of Two Kinds of Markers Applied in Analysis of Genetic Diversity in Sheep and Goat Populations

  • Yang, Z.P.;Chang, H.;Sun, W.;Gen, R.Q.;Mao, Y.J.;Tsunoda, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.7
    • /
    • pp.892-896
    • /
    • 2004
  • A genetic examination using 14 structural loci and 7 microsatellite markers was carried out among random samples of Hu sheep (Hu), Tong sheep (Tong) and Yantse River Delta White goat (YRD); The mean heterozygosity (H), mean polymorphism information contents (PIC) and mean effective numbers of alleles (Ne) calculated based on the data from the above two types of genetic markers were compared. The standard genetic distances among the three populations based on two types of gene frequencies were calculated and compared. The results show that the mean heterozygosity (H), mean polymorphism information contents (PIC) and mean effective numbers of alleles (Ne) based on 7 microsatellite markers are greater than those based on the structural loci. The standard genetic distances based on structural loci among the three populations are: 0.0268-0.2487, the standard genetic distances based on microsatellite markers are: 0.2321-1.2313. The study indicates that structural and microsatellite markers reflect the genetic variation of the three populations consistently: Tong>Hu>YRD. The differentiation between related species or interpopulations can be expressed more effectively by microsatellite markers than structural markers. Oar FCB11, MAF33, Oar AE101, Oar FCB128 and OarFCB304 can be used as representative loci for research on genetic differentiation between sheep and goat.

Dose comparison according to Smooth Thickness application of Range compensator during proton therapy for brain tumor patient (뇌종양 환자의 양성자 치료 시 Range Compensator의 Smooth Thickness 적용에 따른 선량비교)

  • Kim, Tae Woan;Kim, Dae Woong;Kim, Jae Weon;Jeong, Kyeong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.139-148
    • /
    • 2016
  • Purpose : Range Compensator used for proton therapy compensates the proton beam dose which delivers to the normal tissues according to the Target's Distal Margin dose. We are going to check the improvement of dose on the target part by comparing the dose of PTV and OAR according to applying in different method of Smooth Thickness of Range Compensator which is used in brain tumor therapy. Materials and Methods : For 10 brain tumor patients taking proton therapy in National Cancer Center, Apply Smooth Thickness applied in Range Compensator in order from one to five by using Compensator Editor of Eclipse Proton Planning System(Version 10.0, Varian, USA). The therapy plan algorithm used Proton Convolution Superposition(version 8.1.20 or 10.0.28), and we compared Dmax, Dmin, Homogeneity Index, Conformity Index and OAR dose around tumor by applying Smooth Thickness in phase. Results : When Smooth Thickness was applied from one to five, the Dmax of PTV was decreased max 4.3%, minimum at 0.8 and average of 1.81%. Dmin increased max 1.8%, min 1.8% and average. Difference between max dose and minimum dose decreased at max 5.9% min 1.4% and average 2.6%. Homogeneity Index decreased average of 0.018 and Conformity Index didn't had a meaningful change. OAR dose decreased in Brain Stem at max 1.6%, min 0.1% and average 0.6% and in Optic Chiasm max 1.3%, min 0.3%, and average 0.5%. However, patient C and patient E had an increase each 0.3% and 0.6%. Additionally, in Rt. Optic Nerve, there was a decrease at max 1.5%, min 0.3%, and average 0.8%, however, patient B had 0.1% increase. In Lt. Optic Nerve, there was a decrease at max 1.8%, min 0.3%, and average 0.7%, however, patient H had 0.4 increase. Conclusion : As Smooth Thickness of Range Compensator which is used as the proton treatment for brain tumor patients is applied in stages, the resolution of Compensator increased and as a result the most optimized amount of proton beam dose can be delivered. This is considered to be able to irradiate the equal amount at PTV and reduce the unnecessary dose applied at OAR to reduce the side effects.

  • PDF

Comparison of Volumetric Modulated Arc Therapy and Non-coplanar Fixed-field Intensity Modulated Radiation Therapy for Irregular Target adjacent to Organ At Risk (손상위험장기에 인접한 불규칙한 모양의 타겟 치료 시, 용적변조회전 방사선치료와 비동일평면상의 빔을 이용한 세기변조 방사선치료의 유용성 평가 및 비교)

  • Kim, Kyung Ah;Na, Kyung Soo;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.57-68
    • /
    • 2017
  • Purpose: The purpose of this study was to compare volumetric modulated arc therapy(VMAT) with fixed-field intensity modulated radiation therapy(IMRT) using non-coplanar beam when the shape of target is irregular and the location is adjacent to organ at risk(OAR). Materials and Methods: The subjects of this study were a total of 6 patients who had radiation therapy for whole scalp(2 patients), partial scalp(2 patients), and whole ventricle(2 patients) by True Beam STX(Varian Medical Systems, USA). VMAT plans consisted of coplanar or non-coplanar arcs which can minimize the volume of OAR included in beamlets. All fixed-field IMRT plans consisted of non-coplanar beams using more than 2 angles of Couch. Results: The VMAT and IMRT plans were compared with regard to the maximum dose of both lens, both optic nerves, optic chiasm, and brain stem and the mean dose of both eyeballs and hippocampus. VMAT plans showed higher dose than ncIMRT plans at more than 6 of all OARs in every patient, and the ratio was from 1.1 times to 8.2 times. In case of total scalp and partial scalp, the volume of brain which received more than 20 Gy in the VMAT plans was 2 times larger than the volume in the ncIMRT plans. In case of whole ventricle, there was no significant difference. Target coverage was satisfied in both plans($PTV_{100%}=95%$). The maximum dose in target volume and required monitor unit(MU) of ncIMRT were higher than them of VMAT plans. Conclusion: Even though ncIMRT is less efficient than VMAT with regard to required MU and treatment time, the dose to OARs is much lower than VMAT and PTV Coverage is similar with VMAT. If the shape of target is irregular and location is adjacent to OAR, comparison VMAT plan with ncIMRT plan deserves to be considered.

  • PDF