• 제목/요약/키워드: O-Cr system

검색결과 213건 처리시간 0.025초

플라즈마 용사법에 의한 열차폐 코팅의 열피로에 따른 AE신호 특성 연구 (A Study on Acoustic Emission Characteristics through the Cyclic Thermal Test of Thermal Barrier Coating by Plasma Spray Process)

  • 박진효;이구현;예경환;김승태;전채홍;김정석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1349-1352
    • /
    • 2005
  • This paper is to investigate a defect for thermal barrier coating layers by acoustic emission method in 4-point bending test. The two-layer thermal barrier coating is composed of $150\mu{m}\;CoNiCrAlY\;bond\;coating\;by\;vacuum\;plasma\;spray(VPS)\;process\;and\;250\mu{m}\;ZrO_2-8wt%Y_2O_3$ ceramic coating layer by air plasma spray(APS) process on Inconel-718. The specimen prepared by cyclic thermal test(500, 1000, 2000cycle) at $1050^{\circ}C$ The AE monitoring system is composed of PICO type sensor, a wide band pre-amplifier(40dB), PC and AE DSP(16/32 PAC) board. The AE event, amplitude, Cumulative energy and count of coating specimens is evaluated according to cyclic thermal test.

  • PDF

A Study on SPI(soil pollution index) in City Land

  • Kim, Young-Sik;Kim, Gi-Sun;Song, Mi-Ra
    • 한국환경보건학회지
    • /
    • 제33권6호
    • /
    • pp.502-505
    • /
    • 2007
  • To estimate the soil quality of Miryang area, soil analysis were conducted according to the city and out of city of soil expenses at according to analysis components and heavy metal pollution of irradiation sampling sites. The through soil components the principal element about the 71% $SiO_2\;and\;Al_2O_3$, the pH of field area near the city center was lower than that of the other field area, which indicated that this acidification was probably attributed to the acid rain caused by the traffic exhaust gas such as $SO_x\;and\;NO_x$. Acidification was more severe in the field area than in the farming land. The concentration of five heavy metals such as Cu, Cd, Pb, As and Cr were found to be lower than the standard of soil pollution. An assessment using the SPI(Soil Pollution Index), which was developed to estimate an overall soil quality, was performed. Each SPS(Soil Pollution Score) were evaluated with the results of the data from this study. The soil quality of most area of Miryang land was determined to Class 1, which indicated that the soil was healthy.

생쥐 간세포 Mitochondria의 전자전달계에 미치는 Chromium(VI)의 영향 (Effetcs of Hexavalent Chromium on the Mitochondrial Electron Transport System in Mouse Liver)

  • 부문종;유창규;최임순
    • Applied Microscopy
    • /
    • 제17권1호
    • /
    • pp.29-46
    • /
    • 1987
  • To study hexavalent chromium effects on mitochondrial electron transport, the activities of electron transport enzymes and conformational change of mitochondria treated with $40{\mu}M$ of sodium dichromate ($Na_{2}Cr_{2}O_{7}\;2H_{2}O$) were investigated. And so were those of liver mitochondria isolated from mouse intraperitoneally injected with sodium dichromate, 40mg per kg body weight. On both treatment with chromium(VI), the activities of electron transfer enzymes (Complex I and IV) were increased to some extent and the ultrastructural transformation of mitochondria from a condensed to an orthodox conformation was inhibited under State IV respiration. These results represent' inhibitory effect of hexavalent chromium on electron transport without inhibiting electron transfer enzymes (Complex I and IV) in mitochondria. On intraperitoneal treatment with hexavalent chromium as sodium dichromate and trivalent chromium as chromic chloride, containing 37.5 mg of chromium per kg body weight, respectively, the activities of electron transfer enzymes of liver isolated from mouse with chromium(VI) was reduced, but that with chromium(III) was not affected. And with chromium(VI), all mice after 12 hours of treatment died, only after 6 hours survived. With chromium(III), however, all survived. This indicates that hexavalent chromium is more toxic than trivalent chromiumin mouse liver.

  • PDF

Development of Ceramic Humidity Sensor for the Korean Next Generation Reactor

  • Lee, Na-Young;Hwang, Il-Soon;Song, Chang-Rock;Yoo, Han-Ill;Park, Sang-Duk;Yang, Jun-Seong
    • Nuclear Engineering and Technology
    • /
    • 제30권5호
    • /
    • pp.435-443
    • /
    • 1998
  • Leak-before-break(LBB) approach has been shown to be both cost effective and risk reductive when applied to high energy Piping in nuclear Power Plants. For the Korean Next Generation Reactor (KNGR) development, LBB application is considered for the Main Steam Line(MSL) piping inside containment. Unlike the primary system leakages, the MSL leak detection systems must be based on principles other than radioactivity measurements. Among humidity, heat and acoustic noise currently being considered as indicators of leakage, we explored humidity as an effective one and developed ceramic-based humidity sensor which can be qualified for LBB applications. The ceramic material, sintered and annealed MgCr$_2$O$_4$-TiO$_2$, is shown to increase its electrical conductivity drastically upon water vapor adsorption over the entire temperature range of interest. With this ceramic sensor specimen, we suggested installation-inside-the-piping method by which we can detect leakage more rapidly and sensitively. In this paper, we describe the progress in the development and characterization of ceramic humidity sensor for the LBB application to the MSL of KNGR.

  • PDF

하수의 질소제거시 컴퓨터 시뮬레이션을 이용한 UCT(University of Cape Town) 공정의 운영인자 검토 (Investigation of Operating Parameters on UCT Process for the Purpose of Nitrogen Removal Using Computer Simulation)

  • 김병군;서인석;이해군;김창원
    • 환경위생공학
    • /
    • 제13권2호
    • /
    • pp.66-75
    • /
    • 1998
  • The computer simulation model was used to forecast the concentrations of COD$_{cr}$, NH$_{4}$$^{+}$-N and NO$_{3}$$^{-}$-N in each reactors. In the biological wastewater treatment system, the computer simulation model was used to observe the behavior of pollutants especially. In this research, effect of SRT, feeding pattern and recirculation rate on UCT(University of Cape Town) process was evaluated by computer simulation model. T-N removal was affected to the SRT. SRT for effective T-N removal was 15 days or longer. Feeding pattern in UCT process was affected to the T-N removal. Feeding pattern which 100% loading to the first reactor was most effective for T-N removal. The effect of recirculation rate was clear for T-N removal. The recirculation from anoxic reactor to anaerobic reactor was not need but the recirculation from oxic reactor to anoxic reactor was need. In aspect of nitrogen removal efficiency, A/O process was higher than UCT process.

  • PDF

TiO2 졸-겔 코팅 막에 의한 Humic Acid의 광분해 -화학적 산화법에 의한 부식산의 분해처리 기술에 관한 연구 (II)- (The Photocatalytic Degradation of Humic Acid by TiO2 Sol-Gel Coating -Characterization of Humic Acid in the Chemical Oxidation Treatment (II)-)

  • 석상일;안복엽;서태수;이동석
    • 대한환경공학회지
    • /
    • 제22권4호
    • /
    • pp.765-773
    • /
    • 2000
  • $TiO_2$ 코팅매체를 이용한 humid acid의 광분해 특성을 조사하였다. $TiO_2$ 코팅은 $TiOCl_2$ 수용액을 암모니아수로 침전시킨 겔을 과산화수소로 용해한 용액 혹은 졸이나 titanium tetraisopropoxide (TTIP)의 가수분해로부터 제조한 졸을 이용하여 dip-coating법으로 제조하였다. Titanium peroxo 용액을 열처리하여 제조한 졸을 이용한 코팅층은 X-선 회절 분석으로부터 $25^{\circ}C{\sim}500^{\circ}C$ 온도 범위에서 모두 anatase형 결정구조를 가지고 있었다. 반면에 TTIP의 가수분해로 생성된 졸로부터 만든 코팅막은 $400^{\circ}C$ 이상에서 anatase의 결정형이 나타났다. 이로부터 titanium peroxo 용액을 열처리하여 제조한 졸은 내열성 및 비내열성 기판에도 결정성 $TiO_2$ 코팅층을 만들 수 있는 장점이 있다. 코팅막의 두께 및 균일성은 인출속도, 코팅졸의 농도 및 코팅 횟수에 영향을 받았으며, 코팅막의 두께에 따라 다양한 간섭색상을 나타냈다. 0.2M 졸을 이용하여 인출속도 2.5cm/min로 2회 코팅했을 경우, 약 50nm 두께의 투명하면서도 균일한 흐린 남색을 띠는 $TiO_2$ 코팅막을 얻을 수 있었다. 이상의 방법으로 직경 0.3cm의 유리구슬에 $TiO_2$ 코팅막을 제조한 후 $580cm^3$의 반응조를 사용하여 $UV/H_2O_2$ 공정으로 humic acid를 40분 동안 광반응시킨 결과, 초기 시료의 $COD_{cr}$ (40ppm) 을 약 85% 이상, 흡광물질을 약 95% 이상 제거하였다.

  • PDF

초임계수 산화공정에서 Ethylenediaminetetraacetic Acid (EDTA) 분해 최적화 연구 (Optimal Condition for Decomposition of Ethylenediaminetetraacetic Acid (EDTA) in Supercritical Water Oxidation)

  • 이현철;인정현;김종화;이창하
    • Korean Chemical Engineering Research
    • /
    • 제43권2호
    • /
    • pp.318-323
    • /
    • 2005
  • 초임계수 산화는 난분해성 유기화합물의 분해를 위한 공정으로 각광받고 있다. 본 연구에서는 연속반응기에서 온도 $387-500^{\circ}C$, 압력 250 bar의 초임계수 조건하에서(EDTA 분해효율) 체류시간 15.9-88.9초의 범위의 EDTA 분해효율을 측정하였다. 이때 산화제로는 과산화수소($H_2O_2$)를 사용하였다. EDTA의 분해효율은 온도 및 산화제투입량의 증가에 따라 상승하였으며, 반응물 도입유속의 감소 즉, 체류시간의 증가에 따라서 상승하였다. 본 연구결과 온도 $500^{\circ}C$, 압력 250 bar, 산화제 투입량 400%의 조건에서 최대 99.6%의 분해효율을 나타내었다. 분해효율에 미치는 온도의 영향이 산화제 투입량 증가의 영향보다 컸으며, 5,000 mg/L의 EDTA($COD_{Cr}$로서 3,063 mg/L)의 99% 이상 분해효율은 온도 $500^{\circ}C$와 압력 250 bar의 초임계수 산화조건에서 산화제투입량 200% 이상 및 체류시간 40.1초 이상에서 얻을 수 있었다.

RF 마그네트론 스퍼터링으로 증착된 리튬 이온 이차전지 양극용 바나듐 옥사이드 박막에 관한 연구 (A Study on the Vanadium Oxide Thin Films as Cathode for Lithium Ion Battery Deposited by RF Magnetron Sputtering)

  • 장기준;김기출
    • 한국산학기술학회논문지
    • /
    • 제20권6호
    • /
    • pp.80-85
    • /
    • 2019
  • 이산화바나듐은 잘 알려진 금속-절연체 상전이 물질이며, 바나듐 레독스 흐름 전지는 대규모 에너지 저장장치로 활용하기 위해서 많은 연구가 이루어져왔다. 본 연구에서는 바나듐 옥사이드 ($VO_x$) 박막을 리튬이온 이차전지의 양극으로 적용하는 연구를 수행하였다. 이를 위해서 $VO_x$ 박막을 실리콘 웨이퍼 위에 열산화공정으로 300 nm 두께의 $SiO_2$ 층이 형성된 Si 기판 및 쿼츠 기판 위에 RF 마그네트론 스퍼터 시스템으로 60분 동안 $500^{\circ}C$에서 다른 RF 파워로 증착하였다. 증착된 $VO_x$ 박막의 표면형상을 전계방출 주사전자현미경으로 조사하였고, 결정학적 특성을 Raman 분광학으로 분석하였다. 투과율 및 흡수율과 같은 광학적 특성은 자외선-가시광선 분광계로 조사하였다. Cu Foil 위에 증착된 $VO_x$ 박막을 리튬이온전지의 양극물질로 적용하여 CR2032 코인셀을 제작하였고, 전기화학적 특성을 조사하였다. 그 결과 증착된 $VO_x$ 박막은 RF 파워가 증가할수록 낟알 크기가 증가하였고, RF 파워 200 W 이상에서 증착된 박막은 $VO_2$상을 나타내었다. 증착된 $VO_x$ 박막의 투과율은 결정상에 따라 다른 값을 나타내었다. $VO_x$ 박막의 이차전지 특성은 높은 표면적을 가질수록, 결정상이 혼재될수록 높은 충방전 특성을 나타내었다.

액체방사성폐기물에 대한 화학적, 생물학적 제염기술 개발 및 APR1400 액체폐기물관리계통 적용을 위한 타당성 연구 (Development of Chemical and Biological Decontamination Technology for Radioactive Liquid Wastes and Feasibility Study for Application to Liquid Waste Management System in APR1400)

  • 손영주;이승엽;정재연;김창락
    • 방사성폐기물학회지
    • /
    • 제17권1호
    • /
    • pp.59-73
    • /
    • 2019
  • 원자력발전소 운영 과정에서 발생되는 폐기물인 폐수지를 원천적으로 저감하기 위해, 새로운 폐수 정화기술을 개발하고 원전 폐수처리시스템에 가상적으로 적용하여 효용성을 평가하고자 하였다. 본 기술의 기본 원리는 폐수에 존재하는 주요 핵종이온들을 생물학적 혹은 화학적 방법을 통해 무기 결정광물로 바꾸는 방식이다. 실험실에서 폐수를 대상으로 회분식실험을 통해 핵종 제거율을 측정한 결과, 생물학적 방법은 24시간 이내에 세슘을 80% 이상 제거하였고, 화학적 방법은 95% 이상 세슘을 선택적으로 제거할 수 있었다. 그리고 원전 폐수에 존재하는 다른 주요 핵종들(Co, Ni, Fe, Cr, Mn, Eu)에 대해서도 초기 99% 이상의 높은 제거율을 보여 주었다. 우리는 APR1400 원자력발전소의 폐수처리시스템 공정에서 역삼투압(R/O)과 유기 이온교환수지 모듈 사이에 가상으로 본 기술 모듈을 설치하였다. 가상의 모듈 설치를 통한 기술적 타당성 평가를 통해, 우리는 폐수의 주요 핵종들이 90% 이상 선택적으로 제거되고 폐수지의 발생량이 대폭 감소된다는 결과를 얻을 수 있었다. 이러한 결과가 의미하는 바는 본 기술이 향후 미래에 상용화되었을 경우, 폐수지 관리 비용을 크게 감소시키고 수지 수명도 대폭 연장시킬 수 있어, 결과적으로 월성 방사성폐기물 처분시설의 저장고 포화시점을 최대한 늦출 수 있는 이점이 있다.

원전낙뢰보호 및 접지계통에 대한 규제기술연구 (A Study on the Regulatory Technology for Lightning Protection and Grounding System in Nuclear Power Plants)

  • 이재도;주운표;이상근;김대식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.66-68
    • /
    • 2007
  • The regulatory guide, RG-1.204 and its underlying or confirmatory research, NUREG/CR-6866 were studied for Korean application to LPGS of NPPs. However they excluded the application to that of NPPs. So US-NRC approved selectively industrial standards to that of NPPs on Nov 2005. It is necessary to understand the basis of regulatory technology related regulatory positions on LPGS and important to implement the guidance on LPGS as a resonable standard. The paper is examined what and how state of the art of relevant technology applied to the LPGS as well as the trip-out events related to electrical system were involved with LPGS. We reviewed the relevant standards applicable to Korean NPPs. Following are concluded to recommend. (1) IEEE 510-1050 is recommended as a guide for I&C grounding against EMI and lighting transients (2) IEEE Std-665, 510-666, Std-C62.23 for electrical grounding against voltage surges and lighting transients (3) Inspection should be thoroughly be implemented a frequency of 3-5 year period according to NFPA780 or KSC-IEC 61024.

  • PDF