• 제목/요약/키워드: Numerical ventilation

검색결과 323건 처리시간 0.026초

실내 오염물질의 희석환기에관한 모델링 (Modelling for Dilution Ventilation of Indoor Contamination Materials)

  • 심성훈;조상준;김광영
    • 한국기계연구소 소보
    • /
    • 통권19호
    • /
    • pp.31-42
    • /
    • 1989
  • To investigate design factors of dilution ventilation system, numerical analysis of air contamination flow and concentration distribution have been made, by using the low Reynolds number turbulent model. And flow visualization and measurement of particle concentration for that model also have been made. By comparing of these results we have secured the essential data for the adequate counterplan of dilution ventilation system. The results of this study are as follows: 1) Inlet should be located near the wall for the prevention of the formation of the recircula¬tion zone. 2) In case of natural exhaust, air contamination flow is driven to the far outlet from the inlet. 3) It is favorable for dilution to make turbuence as much as possible.

  • PDF

Numerical Analysis on the Effect of Parameters that Affect the Flow Rate through the Tunnel with Jet Fan Ventilation System

  • Kim, Sa-Ryang;Hur, Nahmkeon;Kim, Young-Il;Kim, Ki-Jung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권4호
    • /
    • pp.178-187
    • /
    • 2003
  • In this study, ventilation flow rate and pressure rise through a tunnel are simulated numerically using computational fluid dynamics (CFD) for various conditions such as roughness height of the surface of tunnel, swirl angle and hub/tip ratio of jet fan, and entrance and exit effects. By using a modified wall function, friction factor can be predicted with respect to the Moody chart within 10% of error for the circular pipe flow and 15% for the present tunnel. For more accurate design, the effect of the swirl angle and hub/tip ratio of jet fan, which is not included in the theoretical equation of pressure rise by jet fan needs to be considered.

국소환기시스템의 후드형상 개선에 따른 수치해석 (Numerical Analysis on Hood Shape Improvement of Local Ventilation System)

  • 이중섭;장성철;최주홍
    • 설비공학논문집
    • /
    • 제21권4호
    • /
    • pp.260-265
    • /
    • 2009
  • The aim of this study is to remove crack on a ventilation device at the suction part of zinc plating factory, and the main point is making optimum configuration by improving an existing hood system. The result shows that existing hood system has problem with duct configuration, angle and reducer. Model-5 shows lowest pressure difference as meaning of suction capability. The hood inlet surface has most uniform suction capability.

강제환기를 적용한 이글루형 탄약고 저장환경 개선에 관한 수치적 연구 (Numerical Study on Improvement of Storage Environment of Igloo-Shaped Magazine Using Forced Ventilation)

  • 윤해든;김성훈
    • 한국군사과학기술학회지
    • /
    • 제24권1호
    • /
    • pp.99-106
    • /
    • 2021
  • This study explores the improvement of storage environment of igloo-shaped magazine using forced ventilation. Conjugate heat transfer analysis of forced convection and conduction are performed to calculate the flow, temperature, and relative humidity field in igloo-shaped magazine. Through the conjugate heat transfer analysis, the effects of inlet vent, volume flow rates of jet, and jet angles on the condensation and relative humidity are numerically investigated. The area of condensation in igloo-shaped magazine and relative humidity at the surface of ammunitions are then calculated.

구획 화재의 상사 법칙 유효성에 관한 수치해석 연구 (Numerical Study on the Validity of Scaling Law for Compartment Fires)

  • 고권현
    • 한국화재소방학회논문지
    • /
    • 제28권4호
    • /
    • pp.29-34
    • /
    • 2014
  • 본 연구에서는 구획화재의 연구에 적용되는 환기 변수에 근거한 상사 법칙의 유효성을 평가하기 위해 실규모 및 2/5 축소 구획에 대한 화재를 FDS를 이용하여 모사하고 기존의 실험 및 해석 결과간의 상호 비교 분석을 수행하였다. 상층부 주요 위치에서의 온도에 대한 실험 결과를 근거로 수치해석 모델의 유효성을 확보하였다. 구획 내부의 온도 및 농도 분포와 구획 출구에서의 속도 분포 등에 대한 다양한 특성에 대한 분석을 통해 축소 법칙의 유효성을 평가하였다. 실규모 및 축소 구획에 대한 화재 해석 결과를 비교할 때, 구획 내부 유동 형태 및 화염의 분출 거동, 구획 내부 수직 온도 분포 등의 특성에 대해서 유사한 결과를 보여주었다.

존 모델을 이용한 종류식 배연 터널 화재시 연기 거동에 대한 수치해석적 연구 (A Numerical Study on Smoke Movement in Longitudinal Ventilation Tunnel Fires Using a Zone Model)

  • 김현정;노재성;김동현;장용준;유홍선
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1319-1324
    • /
    • 2007
  • Many researches have been performed to analyze the smoke movement in tunnel fires by using field model. Recently, FDS(Fire Dynamics Simulator) v.4, which is one of the field model and developed from NIST(National Institute of Standards and Technology), is widely used. In tunnel fires, FDS can show detail results in local point, but it has difficulties in boundary condition and taking long computing time as the number of grid increases. So, there is a need to use alternative method for tunnel fire simulation. A zone model is different kind of CFD method and solves ordinary differential equation based on conservation and auxiliary equations. It shows good macroscopic view in less computing time compared to field model. In this study, therefore, to confirm the applicability of CFAST in tunnel fire analysis, numerical simulations using CFAST are conducted to analyze smoke movement in longitudinal ventilation reduced-scale tunnel fires. Then the results are compared with experimental results. The differences of temperature and critical velocity between numerical results and experimental data are over $30^{\circ}C$ and 0.9m/s, respectively. These values are out of error range. It shows that CFAST 6.0 is hard to be used for tunnel fire simulation.

  • PDF

주방환기용 그리스 필터의 입자포집 특성에 관한 수치해석 (A Numerical Study on the Particle Collection Characteristics of a Grease Filter for Kitchen Ventilation)

  • 김기정;배귀남;김영일;허남건
    • 설비공학논문집
    • /
    • 제14권10호
    • /
    • pp.792-800
    • /
    • 2002
  • A grease filter is used to remove grease generated from a cooking appliance in a kitchen. This numerical study has been conducted to investigate the particle collection characteristics of a grease filter having nominal flowrate of $100m^3$/h. The flow field and particle trajectories in the grease filter with a flow chamber were simulated by using the commercial code of STAR-CD. The air velocity and pressure distributions were discussed in detail. The pressure drop of a grease filter rapidly increases with increasing the air flowrate. The numerical values of the pressure drop are slightly lower than the experimental values when the air flowrates are 50, 75, and 100㎥/h. The particle collection efficiency of a grease filter increases with increasing the particle diameter, the particle density, and the air flowrate, which means that the inertial impaction is a dominant particle removal mechanism in a grease filter. The cut-off diameter of the tested grease filter representing 50-% collection efficiency is about 11.6$\mu$m for water droplets at $100m^3$/h.

수치해석적 방법을 이용한 비등온 고농도 연무의 배기량 산정에 관한 연구 (The Numerical Study on the Ventilation of Non-isothermal Concentrated Fume)

  • 임석채;장혁상;하지수
    • 대한환경공학회지
    • /
    • 제30권5호
    • /
    • pp.534-543
    • /
    • 2008
  • 연무거동을 해석하는 방법 중에서 실물을 이용한 실험방법이 가장 믿을 수 있는 자료를 제공하지만 여러 가지 제한사항들로 인해 축소모델실험을 이용한 상사방법이나 CFD(computational fluid dynamics)를 이용한 수치해석적 방법이 대안으로 채택되고 있다. 본 연구는 연무거동을 수치해석적 방법으로 예측하여 연층의 높이에 따른 배기량을 산정하고자 했다. 수치해석에 사용된 격자는 축소실험에서 사용된 모델 A, B와 동일한 크기 및 형상을 가진다. 배기량은 수치해석으로 예측된 연소생성물들의 몰비를 이용하여 연층의 높이를 예측하고 그때의 배기가스 온도 및 유속으로 산정되었다. 수치해석 결과, 벽면 열손실 및 복사효과를 고려하여 예측된 배기량이 축소모델 실험결과의 표준편차 범위 내에 존재하였지만 에너지 방출량이 증가할수록 예측된 연무의 온도가 실험과 많은 차이를 보였고 비교적 열손실에 의한 영향이 적은 모델 B를 이용한 계산결과에서는 연무의 거동이 실험결과와 유사한 패턴을 가지는 것으로 나타났다. 따라서 열손실을 보정할 적절한 보정계수를 구할 수 있다면 배기량 산정에 관한 다양한 후속연구를 수치해석적 방법을 이용해 진행할 수 있을 것이라 사료된다.

버스전용 지하주차장의 환기 특성에 관한 수치해석적 연구 (Numerical Simulation on Ventilation Characteristics of an Underground Bus Parking Lot)

  • 승삼선;이승철
    • 한국산학기술학회논문지
    • /
    • 제8권2호
    • /
    • pp.179-184
    • /
    • 2007
  • 본 연구에서는 전산유체역학 기법을 도입하여 17대 버스가 주차된 지하주차장의 환기특성을 분석하였다. 그 결과 지하주차장내 버스 4대가 운행할 때 CO와 $NO_x$의 평균농도는 각각 1.3과 0.3 ppm으로 나타났다. 또한 15대 버스가 공회전할 때 지하주차장내의 CO와 $NO_x$의 평균농도는 2.9와 0.8 ppm으로 각각 나타났다 따라서 두 가지 경우의 결과가 허용기준을 충족하여 지하주차장에 설치될 환기설비의 용량 및 위치는 적정한 것으로 판단된다.

  • PDF

지하 수처리시설 유지관리층 환기설비의 성능평가 (Evaluation of the Ventilation Efficiency in an Underground Sewage Disposal Plant)

  • 강한기;이재헌
    • 설비공학논문집
    • /
    • 제19권10호
    • /
    • pp.695-702
    • /
    • 2007
  • In this paper, the ventilation efficiencies of an underground sewage disposal plant were investigated for ventilating system without fan, ventilating system with eleven cross flow fans and ventilating system with sixteen cross flow fans by numerical method. It has been found that the air change effectiveness of the system without fan was predicted 0.44. It means that an additional ventilating equipment is needed to maintain good indoor air quality. For the ventilating system with sixteen cross flow fans, the air change effectiveness was predicted 0.55. The air change effectiveness of the ventilating system with eleven cross flow fans was predicted 0.51. It is known that the air change effectiveness above 0.5 is enough to eliminate pollutant and bad smell in the indoor. Therefore, it is recommended to select the ventilating system with eleven cross flow fans for the underground sewage disposal plant in an economic point of view.