• Title/Summary/Keyword: Numerical ventilation

Search Result 323, Processing Time 0.03 seconds

The Analysis of Ventilation of Road Tunnel in Fire (도로터널 화재시의 환기분석)

  • Kom, Sung-Joon;Ryu, Jin-Woong
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.9-13
    • /
    • 2003
  • Numerical experiments are done by a commercial code, PHOENICS to evaluate the backlayer phenomenon of smoke in case of the road tunnel fire. The independent and dependent variables are ventilation air velocity and the length of backlayer of smoke respectively. Hybrid scheme and ${\kappa}-{\varepsilon}$ turbulence model are adopted in the simulation process and mass residual is used as a convergence criterion. The experimental results say that the length of backlayer is reduced with the increase of ventilating air velocity and that there is a critical air velocity which prevents from the onset of backlayering phenomena. One finds that there is a fresh air region near the bottom of tunnel which could make the passenger escape safely from the polluted region by smoke. These phenomena come from the vertical stratification of the smoke air mixture in the tunnel.

  • PDF

소형 활주선의 CFD 수치해석 기법 연구

  • Im, Jun-Taek;Seo, Gwang-Cheol;Park, Geun-Hong;Kim, Sang-Won
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.11a
    • /
    • pp.216-217
    • /
    • 2018
  • 소형 활주선의 경우, 대형 저속선 대비 항주자세의 변화가 크기 때문에 CFD 해석시 저항성능과 운동성능 결과에 오차가 발생할 수 있다. 본 연구에서는 Warped 2 선형을 대상으로 상용 CFD 코드인 STAR-CCM+ v9.04를 사용한 CFD해석을 수행하여, 이를 모형시험 결과와 비교하여 오차를 확인하였고, 또한 오차의 원인을 분석했을 때, 선체 하부의 Numerical ventilation 현상과 Spray 영역에 문제가 있다고 판단하였다. 추후 연구에서는 오차 해결 방법으로 VOF Phase replacement 기법과 Spray 영역에 대한 격자 최적화 방법을 연구하고자 한다.

  • PDF

A Numerical Analysis on the Airflow Characteristics in Super Cleanrooms with Different Design Types (초청정 클린룸 공조방식에 따른 기류특성에 관한 수치해석)

  • 노광철;이승철;오명도
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.751-761
    • /
    • 2003
  • We performed the numerical analysis on the airflow characteristics in the two type of cleanroom systems, which are the axial fan type (AFT) and the fan filter unit (FFU). A computational fluid dynamic model was applied to investigate and compare the nonuniformity, the deflection angle and the air ventilation effectiveness of the two designs of cleanrooms when dampers are adjusted and not adjusted. And the flow-resistance models of the various components were used in this simulation. We know that the airflow characteristics of the cleanrooms are largely affected by damper adjusting And we also find out that the FFU system is superior to the AFT system through the comparison of the cleanroom performance indices.

A Numerical Study on Two-Dimensional Turbulent Flow Field Around a Building (건물주위의 이차원 난류류동장에 대한 수치적 해석)

  • Won Sung Pil;Lee Dong Hwan
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.2
    • /
    • pp.166-175
    • /
    • 1987
  • The heat loss of a building within a wind flow field results from convection and natural ventilation. Loss from natural ventilation is much more than one from convection, and the former depends mostly on the pressure distribution at the building surface. Therefore, the objective of the present study is to calculate the pressure distribution and investigate flow phenomena, around the building with a rectangular shape in a two-dimensional turbulent flow field. The finite difference method, modelled upon the turbulence $k-\epsilon$ model, has been applied to the analysis. The results, followed by the changes of Reynolds numbers, inlet flow conditions, and building shapes, have been also obtained, respectively. Various results of the present numerical analysis coincide qualitatively well with earlier reported empirical results.

  • PDF

A numerical study on effects of drag coefficient of vehicle on jet fans in case of fire in road tunnels (도로터널 화재시 차량의 항력계수가 제연용 제연팬에 미치는 영향에 대한 해석적 연구)

  • Yoo, Yong-Ho;Yoo, Ji-Oh;Kim, Hyo Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.6
    • /
    • pp.553-560
    • /
    • 2014
  • The road tunnel install a vent for the purpose of ventilation and smoke control. Ventilation equipment capacity(number of jet fans) depends on from the condition that of the pressure and ventilation resistance. Pressure and the resistance under operating vehicle have affected on the drag coefficient. The drag coefficient of the tunnel have affected by the blockage effect and slipstream effects. However, when calculating the ventilation fan, are not properly consider taking into account such effects. Therefore, ventilation force may have been slightly overestimated. This paper describes the drag coefficient through a numerical analysis to calculate the equivalent resistance area that reflects the vehicle distance, and examined the equivalent resistance area. The ventilation coefficient corresponding to the result heavy vehicle mixing ratio of the present study was not clear. Equivalent resistance area had reduced by about 86% compared to the road design handbook current standards. Also it had analyzed and reduced to 62.2% compared to Korea Highway Corporation ventilation design criteria ratio, which is the old standard.

Numerical Study on the Improvement Heat and Smoke Control System in Old Subway Station on Train Fire (수치해석을 통한 노후 지하철 역사 내 열차 화재 시 제연모드 개선에 관한 연구)

  • Kim, Hyo-Gyu;Baek, Doo-San;Yoo, Yong-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.88-96
    • /
    • 2017
  • The subway can transport a lot of people at a certain route at once, and the railway and the platform are underground, so it is advantageous to use the ground space efficiently. But If a fire occurs in a subway that is used by an unspecified number of people, such as the Daegu Subway Fire Disaster, many casualties can occur. As a result of the previous research, it was confirmed that the performance of the ventilation system of the old subway platform was remarkably degraded. Therefore, in this study, based on the experimental results of the previous research, we confirmed the flow of the hot and CO flows according to the ventilation mode in the case of fire by three - dimensional numerical analysis. As a result, it was found that the old ventilation system could not maintain the hot air temperature below the reference value for 4 minutes based on the evacuation time of the platform, and when the ventilation performance was enhanced by adding Oversized Exhaust Ports at the upper part of the platform, And the temperature of the heat flow can be maintained.

A Study on Improvement of Inhalation Efficiency of Hood in Ventilation System for Elimination of Industrial Dust (산업용 분진 제거를 위한 배기장치 내 후드의 흡입성능 개선에 관한 연구)

  • Yang, Ho-Dong;Oh, Yool-Kwon
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.2
    • /
    • pp.1-6
    • /
    • 2008
  • The present study investigates on improvement of inhalation efficiency of hood in ventilation system for elimination of industrial dust. The hood, one of local exhaust ventilation system, has an important function to inhale a pollution source such as harmful dust and industrial waste. In this study, in order to improve the inhalation efficiency of the industrial hood, a new device named "gas-guide-device" was attached to inside of hood. The thermal fluid commercial code "Phoenics ver 3.1" was used to analyze the flow velocity distribution at the hood inlet and around the hood after gas-guide-device was installed. And the flow velocity on each position inside and around the hood was actually measured using the hot wire type anemometer under the same condition as that of numerical analysis. Also, in order to identify the optimum shape of gas-guide-device, numerical analysis and experiments are performed under various conditions and their results are presented. The results of this study revealed that the hood attached with gas-guide-device was higher the inhalation efficiency than that for without one and can be possible to improve the capture velocity of the industrial dust. And the optimum shape of gas-guide-device was identified that the ratio of two sizes of gas-guide-device, X to Y, has 4 to 6 on the basis of the hood size in use and the width (b) of gas-guide-device.

Analysis of Amount of Energy Loss for a Dock System in the Cold Distribution Center (냉동 물류 창고 내 도크시스템을 통한 에너지 손실량 분석)

  • Yang, Sungjune;Kim, Youngjoo;Hur, Jun;Kim, Teasung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.8
    • /
    • pp.419-428
    • /
    • 2017
  • In this study, energy loss due to ventilation load in the dock system was analyzed through simulation. Also, flow generated in the dock system of the warehouse was measured using manufactured measuring devices. Numerical simulation was conducted by simulating the most common picking tasks by examining the actual working environment. Incompressible and unsteady turbulent flows were assumed, and the turbulence model was the k-e standard model. Proper grid was selected through grid dependency test. Measurement was conducted using Honeywell and Vaisala sensors, and flow and temperature inside the warehouse were measured and compared with simulation results to validate simulation. When comparing amount of loss occurring in two hours and amount of loss occurring in 15 minutes, docking time of the former was eight times longer but energy loss was 3.8 times lower. Ventilation load occurring during the initial period after opening docking system accounted for a large proportion of total ventilation load. Also, comparing the load when the dock was closed and the load when the truck was parked, ventilation load was significantly higher than load due to heat conduction from the wall. Therefore, in improving the docking system, it is effective to reduce the gap by improving compatibility of the docking system and truck, rather than wall material.