• Title/Summary/Keyword: Number of appropriate parking lots

Search Result 8, Processing Time 0.024 seconds

A Basic Study for Calculating Appropriate Number of Parking Lots at University Hospital in Metropolitan Area (수도권 대학병원의 적정 주차대수 산정을 위한 기초적 연구)

  • Kwon, Soonjung;Seo, Junghyuk;Choi, Byungdeuk
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.3
    • /
    • pp.27-33
    • /
    • 2011
  • The purpose of this study is to propose reasonable standards related to securing the number of parking lots of university hospital in Korea. High proportion of visitors use their cars in order to receive consultation and treatment from doctors and feel the shortage of parking capacity of hospital, resulting to the low satisfaction level in using hospital. Of course, every hospital meets the parking regulation of the government. Therefore it is necessary to consider another parking demand factors besides the parking regulation of the government in order to secure proper number of parking lots in hospital. This study proposes number of hospital beds, vicinity of public transportation, number of doctors and staffs of hospital, and peak time parking demand as the parking demand factors.

Calculation of Appropriate Number of Parking Lots for Cultural and Assembly Facilities - Focused on the Gwangju Metropolitan City Movie Theater - (문화 및 집회시설 적정 주차면 수 산정에 관한 연구 - 광주광역시 영화관을 중심으로 -)

  • Jin, Tae-Hee;Kwon, Sung-Dae;Jin, Il;Ha, Tae-Jun;Lee, Hyung-Mu;Lee, Gang-Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.551-557
    • /
    • 2021
  • Attached parking lots installation criteria is determined by use, total floor area, etc. according to the Parking Lot Act and local government ordinances. However, with traffic demand increase inconvenience about use of culture and assembly facilities have been raised. When planning number of parking lots for cultural and assembly facilities, legal parking lots and unit parking lots are used, but this causes inconvenience and traffic problems on the surrounding roads, because reality and convenience are not considered. Therefore, this study intend to present an realistic number of parking lots calculating equation for movie theater in Gwangju Metropolitan City. After investigating number of parking lots, number of screens, number of seats, total floor area, bus route and illegal parking for a cultural facility in Gwangju Metropolitan City, prediction model for calculating number of parking lots was presented using SPSS regression analysis. As a result of comparing prediction model and unit method, the prediction model was be closer actual cumulative parking space, so prediction model verification was completed. Based on the model verified in this study, Realistic number of parking lots will be installed. However, due to limitations of research on specific areas, research on various facilities should continue in consideration of regional, population, and urban characteristics

Research on The Modeling of Appropriate Parking Space for Mass Traffic Generating Facilities (대량 교통유발시설의 적정주차 추정모형구축에 관한 연구)

  • 오윤표;장무렬
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.3
    • /
    • pp.61-73
    • /
    • 2001
  • The purpose of this study is to simulate the suitable space of parking lots for Mass traffic instigating facilities in Pusan. After the suitable scale of parking lots estimate using GPSS, one of the Queue Simulation, with the average arriving time and the average parking time at parking lots, the formula is simulated by the Regression model to relate a total floor area and the suitable number of parking lots. The improved criteria or present parking lots is needed to prevent the unnecessary vehicles and improve the efficiency of land use. The suitable scale of parking lots estimate just with the state of using the parking lots in this study. but it is necessary to consider land use, traffic condition, commercial area etc.

  • PDF

Estimation of Parking Lot Planning and, Suggestion of Parking Planning Methods Considering Vehicle Types (차종을 고려한 주차 계획단위 산정 및 주차계획 방법 제시)

  • Kwon, Sung-Dae;Park, Je-Jin;Kim, Joong-Hyo;Ha, Tae-Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.6D
    • /
    • pp.755-764
    • /
    • 2011
  • At the present, planning and installation of parking space sections and lane width are implemented in accordance with the installation standard and parking lot structure by the enforcement regulations of the Parking Act. While large and RV (Recreational Vehicle) vehicles have increased in number recently, parking is complex with improper installation standards. It causes serious problems, including vehicle vandalism, increased civil complaints, travel inconveniences for parking lot users, management and maintenance issues for parking lots, and so forth. The study, therefore, determined that the practical and appropriate realignment of parking unit adjustment and lane width regulations are essential. The study conducted prior review on domestic parking sections and change cases of composition by vehicle types, including the component ratio of domestic and foreign vehicles, width of vehicle by types in order to examine the parking problems that account for a increasing social issues, and provided parking plan methods by types of vehicle, as well as reform and reaction plans for parking unit adjustment and lane width considering security and smooth traffic flow. After comparing and analyzing between estimated installation of parking space and lane width and internal and external cases, the study suggests the improvement that considers expenses and convenience of a driver. Also, it shows installation of parking space that considers traffic safety, improvement of lane width, and parking way depends on vehicle types. By providing estimation for parking planning and parking planning methods that secure safe and smooth traffic flow within a parking lot, the study will contribute to the development of improved alternatives for cost-effective traffic safety and set-up structure, including installation standards of parking lots.

Design of Illumination Control System Using Microwave Sensors and Dimming Control (마이크로웨이브센서와 디밍제어를 활용한 조명제어시스템 설계 및 구현)

  • Song, Eun-Seong;Min, Byoung-Won;Oh, Yong-Sun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.19-26
    • /
    • 2013
  • In this paper, we present a novel illumination system for parking lots constructed underground. We design and implement this system using microwave sensors and dimming control of LED fluorescent lamps so that we can obtain lighting efficiency of the illumination scheme. We construct an effective illumination system in the aspects of performance and cost, resulting in energy-saving and electricity reduction. Recently conventional energy-saving method applied to old underground parking lots mainly relies upon turning off the half of total number of lamps installed in the parking lot. Sometimes there are some lots that have infrared sensor to be used to turn on/off the fluorescent lamps to realize these operations smoothing. The other schemes utilize timer to control lighting time of the fluorescent lamps. These conventional schemes are forcing to turn off a part of lamps installed so that we cannot apply them in a systematic way. Moreover they will be most inefficient when we leave them alone to be continuous consumers. The lighting control system proposed in this paper can recognize objects through microwave sensors and inform the appropriate lighting time, furthermore we can adjust brightness of LED lamps following the surroundings using dimming control scheme so that we can epochally improve the illumination system for underground parking lots. According to our sophisticated test experiments, we can maximally obtain 81.9% of energy-saving effectiveness using the system proposed in this paper.

Determination of Dimension of Vertical Curve Elements at Parking Lot Ramps (주차장 램프의 종단곡선 제원 산정에 관한 연구)

  • Kwon, Sung-Dae;Kim, Yoon-Mi;Hong, Jeong-Pyo;Ha, Tae-Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.3
    • /
    • pp.607-616
    • /
    • 2015
  • The demand for cars has been so steadily increasing based on the economic growth that the number of registered cars reached 18,870,000 as of the end of December, 2012. Due to this, the demand for the parking lots also rises continuously. Because of the limited ground space, the buildings ever becoming larger, and the trend of underground parking spaces, recent parking spaces are generally constructed underground. Accordingly, the parking lot ramps slope is limited to less than 17% by relevant laws to ensure the driver safety. However, when a driver enters a parking lot ramps whose slope is slightly steep, he frequently experiences his car body colliding with ramp brackets and often sees the scratches on ramp floor. Thus, this study is intended to prevent any damage to a structure and to contribute to ensuring the riding comfort and safety of drivers and passengers by presenting the details of proper vertical curve to prevent the collision of vehicles with ramp brackets through a vertical analysis of the first and last parts of a parking lot ramps. Because it is necessary to decide the appropriate and suitable vertical slope of a parking lot ramps, this study first identified the problems through site inspection, targeting the parking lot ramps of large buildings frequently that are used by many random people. Next, the possibility of mutual collision was assessed through a theoretical analysis of the first and last parts of a parking lot ramps. Lastly, the vertical curve of a parking ramp was analyzed to estimate its details, which was presented in this study. In conclusion, if the vertical curve presented through this study is used, it will help prevent any damage to the cars and structures, ensure the riding comfort and safety of the drivers, and further reestablish the criteria for vertical installation of a parking lot ramps.

A Study on the Fire Spread Risk of Resident Buildings With Pilotis (필로티 건물 이격거리에 따른 화재확산 위험성 연구)

  • Choi, Seung-Bok;Choi, Doo-Chan;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.103-110
    • /
    • 2017
  • With the common tendency in the accordance with the trend, low-stories built edifices that are Pilotis-oriented structured exponentially and constantly increasing its number of buildings. It inevitably contains its risks of facing conflagrations as most of its part is used as parking lots. In the parking lots, the length of the flame has a heavy-weighted possibility that it would get increased because the heat release rate gets relatively high due to the vehicle insulation. Following on top of that, due to the nature of the Pilotisconsisting of pillars, there is a risk of flame spread to the adjacent building if the same Pilotis-structured buildings are adjacent to each other, if the flame spreads to the surroundings due to the influence of the wind. Because the most of the pilotis-structured-buildings have this entrance that makes the residents be able to enter, if the entrance were plugged the resident get a serious risk of a poisonous gas and a flame. Therefore, if the parking-lots of the pilotis-structured-buildings are adjacent to each other it requires a space to prevent the place from the spread of flame. This research studied how far is appropriate to prevent flame spreading with FDS. As a result, the study found that the distance at least 3.0 m is required.

Aspects of Design and Construction in Entrance Space of the World Heritage Royal Tombs of the Joseon Dynasty (세계유산 조선왕릉 입구공간의 조성 양상)

  • So, Hyun-Su;Park, Hyun-Sook
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.41 no.3
    • /
    • pp.47-58
    • /
    • 2023
  • This study was conducted through reviewing Aspects of Design and Construction in Entrance Space of the World Heritage Royal Tombs of the Joseon Dynasty, which is equipped with parking lots, ticket offices, toilets, exhibition halls, information boards, and rest facilities for the convenience of visitors and the purpose of this study was to propose a direction for improvement. The results of the study are as follows: First, the reduced area of Royal Tombs of the Joseon Dynasty was unable to fully accommodate the ritual movement line, and as a result, the location of the entrance space in the current royal tomb was decided to accommodate minimal convenience functions. In the meantime, the entrance space of the royal tombs has been relocated or renovated in order to achieve its integrity as a World Heritage Site, rational arrangement of movement lines and spatial utility. Second, the size of the entrance space ranges from 1,000 square meters in Jeongneung in Seoul to 16,000 square meters in Hongyuneung in Namyangju, and the number of annual users varies greatly from 12,000 in Onneung in Yangju to 410,000 in Seonjeongneung in Seoul. Considering the conditions of the 16 royal tombs, the entrance space should be provided at an appropriate scale, reflecting the surrounding land use and accessibility that affect the influx of users, the size of the site, and the king's awareness and preferences. Third, the location of the parking lot, the presence or absence of an outer courtyard and an internal courtyard bordering the ticket and check offices, and the location of the Historical and Cultural Museum made it possible to know the aspects of entrance space of the Joseon Royal Tombs, where the spatial configuration is determined Fourth, according to the royal tombs, it was found that the entrance space should have essential parking, access control, information, and convenience functions, and that support, exhibition, passage, and recess functions should be optional. At this time, the management office and the Historical and Cultural Center are in charge of support and exhibition functions. The function of passage can be a strategy that provides a sense of entry and the function of recess which has been introduced in only four royal tombs requires an appropriate location and landscape access.