• Title/Summary/Keyword: Nulling

Search Result 100, Processing Time 0.023 seconds

Recursive Nullspace Calculation for Multiuser MIMO Systems (다중 사용자 MIMO 시스템을 위한 순차적 영공간 계산)

  • Joung, Jin-Gon;Lee, Yong-Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.12A
    • /
    • pp.1238-1243
    • /
    • 2007
  • The computational complexity for the zero-forcing (ZF)-based multiuser (MU) multiple-input multiple-output(MIMO) preprocessing matrices can be immoderately large as the number of transmit antennas or users increases. In this paper, we show that the span of singular vector space of a matrix can be obtained from the singular vectors of the parted rows of that matrix with computational saving and propose a computationally efficient recursive-algorithm for achieving the ZF-based preprocessing matrices. Analysis about the complexities shows that a new recursive-algorithm can lighten the computational load.

Partial Field Decompositon Using Beamforming Method Under Reflective Condition (반사면이 존재하는 환경에서 빔포밍 방법을 이용한 부분 음장 재구성)

  • 선종천;강연준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.730-734
    • /
    • 2003
  • A beamforming method is a kind of spatial filter that focus the amy's signal capturing abilities in a desired direction. In this paper, we detect the location of a source under reflective condition using the multi-dimensional MUSIC algorithm then, we can iud the image source locations from the experimental geometry, and we reconstruct the partial fields for direct wave and reflected wave by using Adaptive nulling algorithm. Numerical simulations are performed to verify its performance under various conditions.

  • PDF

Implementation of Improved Functional Router Using Embedded Linux System (Subspace projection과 SCORE algorithm을 이용한 두 가지 전파방해 대응기술의 성능비교)

  • Han, Sang-Yoon;Shin, Jung-Hwan;Heo, Jun
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.79-80
    • /
    • 2006
  • In this paper, we compare two different anti-jamming schemes, Subspace projection and SCORE algorithm. For multipath cancelation, nulling technique is applied to both anti-jamming schemes. It is noted that SCORE algorithm is more robust to the multipath interference. It is also noted that Subspace projection scheme requires nulling technique for multipath mitigation.

  • PDF

Adaptive Nulling Algorithm for Null Synthesis on the Moving Jammer Environment (이동형 재밍환경에서 널 합성을 위한 적응형 널링 알고리즘)

  • Seo, Jongwoo;Park, Dongchul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.8
    • /
    • pp.676-683
    • /
    • 2016
  • In this paper, an adaptive nulling algorithm which can be used to form nulls in the direction of jammer or interference signals in array antennas of single port system is proposed. The proposed adaptive algorithm does not require a priori knowledge of the incoming signal direction and can be applied to the partially adaptive arrays. This algorithm is the combination of the PSO(Particle Swam Optimization) algorithm and the gradient-based perturbation adaptive algorithm, which shows stable nulling performance adaptively even on the moving jammer environment where the incident direction of the interference signal is changing with time.

Measurement of the acoustic impedance by using beamforming method in a free-field (자유 음장에서 빔형성 방법을 이용한 음향 임피던스 측정)

  • Sun, Jong-Cheon;Shin, Chang-Woo;Baek, Sun-Gwon;Kang, Yeon-June
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.969-974
    • /
    • 2007
  • In this paper, a beamforming technique is introduced to measure the acoustic impedance at both normal and oblique incidence in a free field. The acoustic impedance is obtained by separating incident and reflected signals using the adaptive nulling method which is one of the various beamforming algorithms. To obtain better results, pressure vector commonly used in array signal processing is replaced with the transfer function vector between each microphone and the white Gaussian noise is suppressed by a wavelet shrinkage technique. The experiments conducted in a semi-anechoic room show that the proposed method is efficient and accurate in measuring the acoustic impedance of sound absorbing materials under a free field condition.

  • PDF

Null Steering of Circular Array Using Array Factor for GPS Anti-Jam

  • Kwon, Taek-Sun;Lee, Jae-Gon;Lee, Jeong-Hae
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.4
    • /
    • pp.267-269
    • /
    • 2018
  • In this letter, the null steering of a circular array is presented using a modified array factor (AF) for a global positioning system (GPS) anti-jam. The seven radiating elements were designed using a mu-zero resonance (MZR) circularly polarized (CP) antenna arranged toward the center. Since the radiating elements, which are arranged toward the center, have a CP characteristic, the AF of the seven radiating elements has to be modified considering the rotation angle of the nth radiating element. The phases of input ports can be calculated to implement a nulling of radiation patterns where the modified AF is zero. To verify the modified AF for null steering in the desired direction, two cases of power dividers operating in $L_2$ band (1.2276 GHz) were fabricated to achieve pattern nulling at a certain angle. The modified AF can be confirmed by a comparing the simulated and measured radiation patterns.

Investigation of the Swirling Flow Fields of a Gun-Type Gas Burner by the Measurement of a Five-Hole Pressure Probe (5공 압력프로브의 측정에 의한 Gun식 가스버너의 스월유동장 고찰)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.19 no.1
    • /
    • pp.19-23
    • /
    • 2015
  • The swirling flow fields of a gun-type gas burner(GTGB) without a combustion chamber were measured by a straight-type five-hole pressure probe(FHPP) under the cold flow condition. The three kinds of velocity components and the static pressure were calculated by using a non-nulling calibration method covering the velocity reduction performance of the effective flow attack angle of ${\pm}80^{\circ}$. As a result, the velocity and static pressure measured by a FHPP comparatively shows the better performance on the swirling flow of a GTGB than those measured by X-probe.

General Linearly Constrained Broadband Adaptive Arrays in the Eigenvector Space

  • Chang, Byong Kun
    • Journal of information and communication convergence engineering
    • /
    • v.15 no.2
    • /
    • pp.73-78
    • /
    • 2017
  • A general linearly constrained broadband adaptive array is examined in the eigenvector space with respect to the optimal weight vector and the adaptive algorithm. The optimal weight vector and the general adaptive algorithm in the eigenvector space are obtained by eigenvector matrix transformation. Their operations are shown to be the same as in the standard coordinate system except for the relevant transformed vectors and matrices. The nulling performance of the general linearly constrained broadband adaptive array depends on the gain factor such that the constraint plane is shifted perpendicularly to the origin by an increase in the gain factor. The general linearly constrained broadband adaptive array is observed to perform better than a conventional linearly constrained adaptive array in a coherent signal environment, while the former performs similarly to the latter in a non-coherent signal environment.

A Study on the Five - hole Probe Calibration with Non-nulling Method (비영위법에 의한 5공 프로브의 교정에 관한 연구)

  • Jeong, Yang Beom;Sin, Yeong Ho;Park, Ho Dong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.116-116
    • /
    • 1996
  • This paper is concerned with a method for calibrating five-hole probes of both angle-tube and prismatic geometries to measure local total and static pressures and the magnitude and direction of the mean velocity vector. Descriptions of the calibration technique, the typical calibration data, and an accompanying discussion of the interpolation procedure are included. The flow properties are determined explicitly from measured probe pressures using calibration data. Flow angles are obtained within the deviation angle of 1.0 degree and dynamic pressures within 0.03 with 95% certainty. The variations in the calibration data due to Reynolds number are also discussed. For the range of Reynolds number employed, no effect was detected on the pitch, yaw and total pressure coefficients. However, the static pressure coefficient showed change to cause minor variations in the magnitude of the calculated velocity vector. To account for these variations, average correction factors need to be incorporated into the static pressure coefficient.

A Study on the Five-hole Probe Calibration with Non-nulling Method (비영위법에 의한 5공 프로브의 교정에 관한 연구)

  • 정양범;신영호;박호동
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.48-56
    • /
    • 1996
  • This paper is concerned with a method for calibrating five-hole probes of both angle-tube and prismatic geometries to measure local total and static pressures and the magnitude and direction of the mean velocity vector. Descriptions of the calibration technique, the typical calibration data, and an accompanying discussion of the interpolation procedure are included. The flow properties are determined explicitly from measured probe pressures using calibration data. Flow angles are obtained within the deviation angle of 1.0 degree and dynamic pressures within 0.03 with 95% certainty. The variations in the calibration data due to Reynolds number are also discussed. For the range of Reynolds number employed, no effect was detected on the pitch, yaw abd total pressure coefficients. However, the static pressure coefficient showed change to cause minor variations in the magnitude of the calculated velocity vector. To account for these variations, average correction factors need to be incorporated into the static pressure coefficient.

  • PDF