• Title/Summary/Keyword: Nucleate Boiling

Search Result 209, Processing Time 0.027 seconds

Formation of Thermal Bubble from Particle-Filled Microcavity (미세 입자로 충전된 캐비티에서의 열 기포 형성)

  • Jeong, Kwang-Hun;Lee, Heon-Ju;Chang, Young-Soo;Lee, Yoon-Pyo;Kim, Ho-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.3 s.258
    • /
    • pp.248-255
    • /
    • 2007
  • Thermal bubble formation is a fundamental process in nucleate boiling heat transfer and many microelectromechanical thermal systems. One of the established facts is that heterogeneous nucleation is originated from vapors trapped inside cavities. Based on this, we performed an experimental study on the formation of thermal bubbles from microcavity fabricated by microfabrication technology on a copper plate. The cavity was filled with aluminum particles to enhance thermal bubble formation. We observed the thermal bubble behaviors, such as bubble incipience, diameter, frequency and coalescence during nucleate boiling. The experimental data showed that the superheat required to trigger the bubble formation was significantly reduced when the cavity was filled with microparticles. We found that the initial increase of superheat led to the increase of both the departure diameter and frequency while the further increase of superheat caused multiple bubbles to coalesce resulting in the decrease of departure frequency.

Heat Transfer Characteristics under Saturated Nucleate Pool Boiling for Various Heating Surface Angles using Heater with Artificial Cavity (인공 캐비티를 가진 히터를 이용한 가열면 경사각에 따른 포화상태 풀 핵비등 열전달 기초연구)

  • Kim, Jeong-Bae
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.4
    • /
    • pp.7-14
    • /
    • 2009
  • Nucleate pool boiling experiments with constant heat flux condition were performed using pure R11 and R113 for various surface angles under saturated pool condition. A circular heater of 1 mm diameter, with artificial cavity in the center, fabricated using MEMS technique and the high-speed controller were used to maintain the constant heat flux. Images of bubble growth were taken at 5,000 frames per second using a high-speed CCD camera. The bubble geometry was obtained from the captured bubble images. The effects of surface angles on the bubble growth behaviors were analyzed as dimensional scales for the initial and thermal growth regions. The parameters for the bubble growth behaviors were bubble radius, bubble growth rate, sliding velocity, bubble shape and advancing and receding contact angles. These phenomena require further analysis for various surface angles, but this study will provide good experimental data with constant heat flux boundary condition for such works.

Development Process of FPGA-based Departure from Nucleate Boiling Ratio Algorithm Using Systems Engineering Approach

  • Hwang, In Sok;Jung, Jae Cheon
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.14 no.2
    • /
    • pp.41-48
    • /
    • 2018
  • This paper describes the systems engineering development process for the Departure from Nucleate Boiling Ratio (DNBR) algorithm using FPGA. Current Core Protection Calculator System (CPCS) requirement and DNBR logic are analyzed in the reverse engineering phase and the new FPGA based DNBR algorithm is designed in the re-engineering phase. FPGA based DNBR algorithm is developed by VHSIC Hardware Description Language (VHDL) in the implementation phase and VHDL DNBR software is verified in the software Verification & Validation phase. Test cases are developed to perform the software module test for VHDL software modules. The APR 1400 simulator is used to collect the inputs data in 100%, 75%, and 50% reactor power condition. Test input signals are injected to the software modules following test case tables and output signals are compared with the expected test value. Minimum DNBR value from developed DNBR algorithm is validated by KEPCO E&C CPCS development facility. This paper summarizes the process to develop the FPGA-based DNBR calculation algorithm using systems engineering approach.

A Mechanistic Model for Forced Convective Transition Boiling of Subcooled Water in Vertical Tubes (수직관내 미포화수의 강제대류 천이비등에 대한 역학적 모델)

  • Lee, Kwang-Won;Baik, Se-Jun;Han, Sang-Good;Joo, Kyung-Oin;Yang, Jae-Young
    • Nuclear Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.503-517
    • /
    • 1995
  • A mechanistic model for forced convective transition boiling has been developed to predict transition boiling heat flux realistically. This model is based on a postulated multi­stage boiling process occurring during the passage time of an elongated vapor blanket specified at a critical heat flux condition. Between the departure from nucleate boiling (DNB) and the departure from film boiling (DFB) points, the boiling heat transfer is established through three boiling stages, namely, the macrolayer evaporation and dryout governed by nucleate boiling in a thin liquid film and the unstable film boiling. The total heat transfer rate during the transition boiling is the sum of the heat transfer rates after the DNB weighted by the time fractions of each stage, which are defined as the ratio of each stage duration to the vapor blanket passage time. The model predictions are compared with some available experimental transition boiling data. From these comparisons, it can be seen that the transition boiling heat fluxes including the maximum heat flux and the minimum film boiling heat flux are nil predicted at low qualities/high pressures near 10 bar.

  • PDF

Correlation of Droplet Flow Rate and Spray Cooling Heat Transfer in Forced Convection and Nucleate Boiling Region (강제대류 및 핵비등영역에 있어서 액적유량과 분무냉각 열전달의 상관관계에 관한 연구)

  • Kim, Yeung-Chan
    • Journal of ILASS-Korea
    • /
    • v.13 no.3
    • /
    • pp.143-148
    • /
    • 2008
  • In the present study, the correlation between the Nusselt number and Reynolds number was developed for forced convection and nucleate boiling region in spray cooling. Also the effect of droplet subcooling on spray cooling heat transfer was investigated. Full cone spray nozzles were employed for spray cooling experiment, and water and FC-77 were used for developing the correlation. From the experimental results, the correlation between the Nusselt number and Reynolds number based on droplet-flow-rate was developed. The correlation shows good predictions with ${\pm}30%$ error for water and FC-77.

  • PDF

Conjugate Analysis of Bubble Growth Involving Conduction in Solid (고체의 전도를 포함한 기포성장의 복합적 해석)

  • Son, Gi-Hun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.2
    • /
    • pp.265-273
    • /
    • 2003
  • Numerical analysis of bubble motion during nucleate boiling is performed by imposing a constant heat flux condition at the base of a heater which occurs in most of boiling experiments. The temporal and spatial variation of a solid surface temperature associated with the bubble growth and departure is investigated by solving a conjugate problem involving conduction in the solid. The vapor-liquid interface is tracked by a level set method which is modified to include the effects of phase change at the interface, contact angle at the wall and evaporative heat flux in a thin liquid micro-layer. Based on the numerical results, the bubble growth pattern and its interaction with the heating solid are discussed. Also, the effect of heating condition on the bubble growth under a micro-gravity condition is investigated.

EFFECTS OF GEOMETRIC PARAMETERS ON NUCLEATE POOL BOILING OF SATURATED WATER IN VERTICAL ANNULI

  • Kang, Myeong-Gie
    • Nuclear Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.271-278
    • /
    • 2009
  • Nucleate pool boiling of water in vertical annuli at atmospheric pressure has been studied experimentally and two empirical correlations have been suggested to obtain effects of geometric parameters on heat transfer. Data of the present and the previous tests range over a tube length of 0.50-0.57 m, a diameter of 16.5-34.0 mm, and an annular gap size of 3.7-44.3 mm. Through the analysis, tube bottom confinement (open or closed) has been investigated, as well. The developed correlations predict experimental data within a ${\pm}25%$ error bound. It has been identified that effects of the diameter and the length of heated tubes as well as the annular gap size should be counted into the analyses to estimate heat transfer coefficients accurately.

Nucleate Pool Boiling Heat Transfer in Vertical Annuli (수직 환상 공간 내부의 풀핵비등 열전달)

  • Gang, Myeong-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.8
    • /
    • pp.1113-1121
    • /
    • 2001
  • Effects of gap sizes(3.9 and 15mm) of vertical annuli and the bottom blockage on the nucleate pool boiling heat transfer at atmospheric pressure condition have been examined experimentally, and the results were compared to those with a single tube without confinement. The annular geometry resulted in significant increase in heat transfer coefficient. The effect is much enhanced with the bottom blockage. The heat transfer coefficient for the closed bottom condition is three times greater than the unconfined tube at 30kW/㎡ when the gap size is 3.9mm. However, with further increase of the heat flux much more than 70kW/㎡, all these effects were diminished.

Effects of Tube Diameter on Nucleate Pool Boiling Heat Transfer (튜브 직경이 풀핵비등 열전달에 미치는 영향)

  • Kang, Myeong-Gie
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.7
    • /
    • pp.930-937
    • /
    • 2000
  • A series of data sets for the heat transfer coefficient versus wall superheat has been obtained experimentally using various combinations of tube diameters ($9.7{\sim}25.5mm$), surface roughness ($15.1{\sim}60.9nm$), and tube orientations (horizontal and vertical) to obtain effects of tube diameters on nucleate pool boiling heat transfer for the saturated water at atmospheric pressure. In addition, the results are compared with the well known Cornwell and Houston's correlation for horizontal tubes to identify the deviation of the present experimental data from the correlation and the applicability of it to vertical tubes. The experimental results show that the heat transfer coefficient decreases as the tube diameter increases for both horizontal and vertical tubes and they are in good agreement with the Cornwell and Houston's correlation within ${\pm}20%$ scatter range.

An Experimental Investigation of Heat Transfer in Forced Convective Boiling of R 134a, R 123 and R 134a/R 123 in a Horizontal Tube

  • Lim, Tae-Woo;Kim, Jun-Hyo
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.513-525
    • /
    • 2004
  • This paper reports an experimental study on flow boiling of pure refrigerants R l34a and R l23 and their mixtures in a uniformly heated horizontal tube. The flow pattern was observed through tubular sight glasses with an internal diameter of 10㎜ located at the inlet and outlet of the test section. Tests were run at a pressure of 0.6 MPa in the heat flux ranges of 5-50㎾/㎡, vapor quality 0-100 percent and mass velocity of 150-600㎏/㎡s. Both in the nucleate boiling-dominant region at low quality and in the two-phase convective evaporation region at higher quality where nucleation is supposed to be fully suppressed, the heat transfer coefficient for the mixture was lower than that for an equivalent pure component with the same physical properties as the mixture. The reduction of the heat transfer coefficient in mixture is explained by such mechanisms as mass transfer resistance and non-linear variation in physical properties etc. In this study, the contribution of convective evaporation, which is obtained for pure refrigerants under the suppression of nucleate boiling, is multiplied by the composition factor by Singal et al. (1984). On the basis of Chen's superposition model, a new correlation is presented for heat transfer coefficients of mixture.