• Title/Summary/Keyword: Nuclear reactor coolant

Search Result 551, Processing Time 0.027 seconds

Study on Chemical Decontamination Process Based on Permanganic Acid-Oxalic Acid to Remove Oxide Layer Deposited in Primary System of Nuclear Power Plant (계통 내 침적된 산화막 제거를 위한 과망간산/옥살산 기반의 화학제염 공정연구)

  • Kim, Chorong;Kim, Haksoo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.1
    • /
    • pp.15-28
    • /
    • 2019
  • In accordance with the decommissioning plan for the Kori Unit 1 NPP, the reactor coolant system will be chemically decontaminated as soon as possible after permanent shutdown. This study developed the chemical decontamination process though the development project of decontamination technology of reactor coolant system and dismantled equipment for NPP decommissioning, which has been carried out since 2014. In this study, Oxidation/reduction process was conducted using system decontamination process development equipment of lab scale and was divided into unit and continuous processes. The optimal process time was derived from the unit process, and decontamination agent and the number of process were derived through the continuous processes. Through the unit process, the oxidation process took 5 hours and the reduction process took 4 hours. As optimum decontamination agent, the oxidizing agent was $200mg{\cdot}L^{-1}$ Permanganic acid + $200mg{\cdot}L^{-1}$ Nitric acid and the reducing agent was $2000mg{\cdot}L^{-1}$ Oxalic acid. In the case of the number of processes, all oxide films were removed during the two-cycle chemical decontamination process of STS304 and SA508. In the case of Alloy600, all oxide films were removed when chemical decontamination was performed for three cycles or more.

Thermal-Mixing Analyses for Safety Injection at Partial Loop Stagnation of a Nuclear Power Plant

  • Hwang, Kyung-Mo;Kim, Kyung-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.9
    • /
    • pp.1380-1387
    • /
    • 2003
  • When a cold HPSI (High pressure Safety Injection) fluid associated with an overcooling transient, such as SGTR (Steam Generator Tube Rupture), MSLB (Main Steam Line Break) etc., enters the cold legs of a stagnated primary coolant loop, thermal stratification phenomena will arise due to incomplete mixing. If the stratified flow enters the downcomer of the reactor pressure vessel, severe thermal stresses are created in a radiation embrittled vessel wall by local overcooling. As general thermal-hydraulic system analysis codes cannot properly predict the thermal stratification phenomena, RG 1.154 requires that a detailed thermal-mixing analysis of PTS (pressurized Thermal Shock) evaluation be performed. Also. previous PTS studies have assumed that the thermal stratification phenomena generated in the stagnated loop side of a partially stagnated primary coolant loop are neutralized in the vessel downcomer by the strong flow from the unstagnated loop. On the basis of these reasons, this paper focuses on the development of a 3-dimensional thermal-mixing analysis model using PHOENICS code which can be applied to both partial and total loop stagnated cases. In addition, this paper verifies the fact that, for partial loop stagnated cases, the cold plume generated in the vessel downcomer due to the thermal stratification phenomena of the stagnated loop is almost neutralized by the strong flow of the unstagnated loop but is not fully eliminated.

Temperature and Heat Split Evaluation of Annular Fuel (이중냉각핵연료 온도 및 열유속 분리 평가)

  • Yang, Yong-Sik;Chun, Tae-Hyun;Shin, Chang-Hwan;Song, Kun-Woo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2236-2241
    • /
    • 2008
  • The surface heat flux of nuclear fuel rod is the most important factor which can affect safety of reactor and fuel. If fuel rod surface heat flux exceeds the CHF(${\underline{C}}ritical$ ${\underline{H}}eat$ ${\underline{F}}lux$), fuel can be damaged. In case of double cooled annular fuel, which is under developing, contains two coolant channels. Therefore, a generated heat in the fuel pellet can move to inner or outer channel and heat flow direction is decided by both sides heat resistance which varied by dimension and material property change which caused by temperature and irradiation. The new program(called DUO) was developed. For the calculation of surface heat flux, a both sides convection by inner/outer coolant, s gap temperature jump and conduction in the fuel are modeled. Especially, temperature and time dependent fuel dimension and material property change are considered during the iteration. A sample calculation result shows that the DUO program has sufficient performance for annular fuel thermal hydraulics design.

  • PDF

Development of the Phased Array Ultrasonic Test Technique for the Weld Inspection of Reactor Coolant System 3" Branch Connection Lines in Nuclear Power Plants (원자로냉각재계통 3" 분기관 용접부 위상배열초음파탐상검사(PAUT)기법 개발)

  • Lee, Seung-Pyo;Moon, Yong-Sig;Jung, Nam-Du;Cho, Yong-Bae;Kim, Chang-Soo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.4 no.2
    • /
    • pp.40-45
    • /
    • 2008
  • There exist many types of pipe and component fatigue through vibrations, thermal fatigues or shifting. In some cases of thermal stratification/thermal fatigue, pipes & components are receiving thermal stress by means of material expansion and shrinkage by continuous thermal repetitive variation. Small cracks initially occur on the inside surface by thermal stress. These cracks grow in depth the pipe wall and finally come to a rupture. Pipe parts of susceptibility to thermal stratification and thermal fatigue are now being examined by conventional UT(ultrasonic test) as volumetric examination. It is difficult to fully satisfy the code & standards requirements because 3" weldolet weldments of RCS 16" pipe to 3" branch connection lines have complex structural shape. To solve the problems of conventional UT examination, we made a realistic mock-up and UT calibration block. We performed a simulation of phased array UT utilizing CIVA as NDE(Non-Destructive Examination) simulation software. Also we designed phased array UT transducer and wedge, optimal frequency by using simulation data. We performed phased array UT experiment through mock-up including artificial flaws(notch). The phased array UT technique is finally developed to improve the reliability of ultrasonic test at RCS 16" pipe to 3" branch connection weld.

  • PDF

SEINA: A two-dimensional steam explosion integrated analysis code

  • Wu, Liangpeng;Sun, Ruiyu;Chen, Ronghua;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3909-3918
    • /
    • 2022
  • In the event of a severe accident, the reactor core may melt due to insufficient cooling. the high-temperature core melt will have a strong interaction (FCI) with the coolant, which may lead to steam explosion. Steam explosion would pose a serious threat to the safety of the reactors. Therefore, the study of steam explosion is of great significance to the assessment of severe accidents in nuclear reactors. This research focuses on the development of a two-dimensional steam explosion integrated analysis code called SEINA. Based on the semi-implicit Euler scheme, the three-phase field was considered in this code. Besides, the influence of evaporation drag of melt and the influence of solidified shell during the process of melt droplet fragmentation were also considered. The code was simulated and validated by FARO L-14 and KROTOS KS-2 experiments. The calculation results of SEINA code are in good agreement with the experimental results, and the results show that if the effects of evaporation drag and melt solidification shell are considered, the FCI process can be described more accurately. Therefore, it is proved that SEINA has the potential to be a powerful and effective tool for the analysis of steam explosions in nuclear reactors.

Research on unsupervised condition monitoring method of pump-type machinery in nuclear power plant

  • Jiyu Zhang;Hong Xia;Zhichao Wang;Yihu Zhu;Yin Fu
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2220-2238
    • /
    • 2024
  • As a typical active equipment, pump machinery is widely used in nuclear power plants. Although the mechanism of pump machinery in nuclear power plants is similar to that of conventional pumps, the safety and reliability requirements of nuclear pumps are higher in complex operating environments. Once there is significant performance degradation or failure, it may cause huge security risks and economic losses. There are many pumps mechanical parameters, and it is very important to explore the correlation between multi-dimensional variables and condition. Therefore, a condition monitoring model based on Deep Denoising Autoencoder (DDAE) is constructed in this paper. This model not only ensures low false positive rate, but also realizes early abnormal monitoring and location. In order to alleviate the influence of parameter time-varying effect on the model in long-term monitoring, this paper combined equidistant sampling strategy and DDAE model to enhance the monitoring efficiency. By using the simulation data of reactor coolant pump and the actual centrifugal pump data, the monitoring and positioning capabilities of the proposed scheme under normal and abnormal conditions were verified. This paper has important reference significance for improving the intelligent operation and maintenance efficiency of nuclear power plants.

PARAMETRIC STUDIES ON THERMAL HYDRAULIC CHARACTERISTICS FOR TRANSIENT OPERATIONS OF AN INTEGRAL TYPE REACTOR

  • Choi, Ki-Yong;Park, Hyun-Sik;Cho, Seok;Yi, Sung-Jae;Park, Choon-Kyung;Song, Chul-Hwa;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.38 no.2
    • /
    • pp.185-194
    • /
    • 2006
  • Transient operations for an integral type reactor, SMART-P, have been experimentally investigated using a thermal-hydraulic integral test facility, VISTA (Experimental Verification by Integral Simulation of Transients and Accidents), in order to verify the system design and performance of the SMART-P, a pilot plant of SMART. The VISTA facility was subjected to various accident conditions such as feedwater increase and decrease, loss of coolant flow, and control rod withdrawal accidents in order to elucidate the thermal-hydraulic responses following such accidents and finally to verify the system design of the SMARTP. Full functional control logics have been implemented in the VISTA facility in order to control the required control action for an accident simulation. As one of the sensitivity tests to verify the PRHRS performance, the effects of the initial water level in the compensation tank are experimentally investigated. When the initial water level is 16%, the water is quickly drained and nitrogen gas is then introduced into the PRHR system, resulting in deterioration of the PRHRS performance. It is thus found that nitrogen ingression should be prevented to ensure stable PRHRS operation.

Conceptual Design of the Filter using Electromagnet and Permanent Magnets for Removal of Radioactive Corrosion Products (방사성 부식생성물 제거를 위한 전자석 및 영구자석을 이용한 필터의 개념설계)

  • 송민철;공태영;이건재
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.38-42
    • /
    • 2003
  • In a pressurized water reactor, radioactive corrosion products (CRUD) in primary coolant system are one of the major sources for the occupational radiation exposure of the personnel in a nuclear power plant. Through the recent trend of long term fuel cycle in a nuclear power plant, radioactive corrosion products deposited in reactor core for a long time are also the cause of Axial Offset Anomaly (AOA) having an effect on reactor power by the hideout of boron. CRUD consist primarily of magnetite, nickel ferrite, cobalt ferrite, and so on. They have the characteristic of strong magnetism. Therefore it is peformed the conceptual design to develop the filter which removes the CRUD by magnetic field that is generated by an arrangement of permanent and electric magnets. Contrary to the conventional filter, the proposed filter does not interrupt the fluid flow, so there is little pressure drop and it can be used continuously. It is expected to be applied as one of the technologies for removal of the CRUD.

  • PDF

Neutron Noise Analysis for PWR Core Motion Monitoring (중성자 잡음해석에 의한 PWR 노심 운동상태 감시)

  • Yun, Won-Young;Koh, Byung-Jun;Park, In-Yong;No, Hee-Cheon
    • Nuclear Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.253-264
    • /
    • 1988
  • Our experience of neutron noise analysis in French-type 900 MWe pressurized water reactor (PWR) is presented. Neutron noise analysis is based on the technique of interpreting the signal fluctuations of ex-core detectors caused by core reactivity changes and neutron attenuation due to lateral core motion. It also provides advantages over deterministic dynamic-testing techniques because existing plant instrumentation can be utilized and normal operation of the plant is not disturbed. The data of this paper were obtained in the ULJIN unit 1 reactor during the start-up test period and the statistical descriptors, useful for our purpose, are power spectral density (PSD), coherence function (CF), and phase difference between detectors. It is found that core support barrel (CSB) motions induced by coolant flow forces and pressure pulsations in a reactor vessel were indentified around 8 Hz of frequency.

  • PDF

NUMERICAL APPROACH FOR QUANTIFICATION OF SELFWASTAGE PHENOMENA IN SODIUM-COOLED FAST REACTOR

  • JANG, SUNGHYON;TAKATA, TAKASHI;YAMAGUCHI, AKIRA;UCHIBORI, AKIHIRO;KURIHARA, AKIKAZU;OHSHIMA, HIROYUKI
    • Nuclear Engineering and Technology
    • /
    • v.47 no.6
    • /
    • pp.700-711
    • /
    • 2015
  • Sodium-cooled fast breeder reactors use liquid sodium as a moderator and coolant to transfer heat from the reactor core. The main hazard associated with sodium is its rapid reaction with water. Sodium-water reaction (SWR) takes place when water or vapor leak into the sodium side through a crack on a heat-transfer tube in a steam generator. If the SWR continues for some time, the SWR will damage the surface of the defective area, causing it to enlarge. This self-enlargement of the crack is called "self-wastage phenomena." A stepwise numerical evaluation model of the self-wastage phenomena was devised using a computational code of multicomponent multiphase flow involving a sodium-water chemical reaction: sodiumwater reaction analysis physics of interdisciplinary multiphase flow (SERAPHIM). The temperature of gas mixture and the concentration of NaOH at the surface of the tube wall are obtained by a numerical calculation using SERAPHIM. Averaged thermophysical properties are used to assess the local wastage depth at the tube surface. By reflecting the wastage depth to the computational grid, the self-wastage phenomena are evaluated. A two-dimensional benchmark analysis of an SWAT (Sodium-Water reAction Test rig) experiment is carried out to evaluate the feasibility of the numerical model. Numerical results show that the geometry and scale of enlarged cracks show good agreement with the experimental result. Enlarged cracks appear to taper inward to a significantly smaller opening on the inside of the tube wall. The enlarged outer diameter of the crack is 4.72 mm, which shows good agreement with the experimental data (4.96 mm).