• Title/Summary/Keyword: Nuclear medicine study

Search Result 2,876, Processing Time 0.03 seconds

Biodistribution of Iodine-131-Iodomisonidazole and Imaging of Tumor Hypoxia in Mice bearing CT-26 Adenocarcinoma (CT-26 선암을 접종한 마우스에서 Iodine-131-Iodomisonidazole의 생체분포 및 종양저산소증의 영상화)

  • Kim, Hye-Won;Kim, Chang-Guhn;Yoon, Kwon-Ha;Kim, Hyun-Jeong;Juhng Seon-Kwan;Roh, Byung-Suk;Yang, David J.;Kim, E.Edmund;Lee, Hyun-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.289-297
    • /
    • 1999
  • Purpose: Misonidazole is a radiosensitizer that binds in hypoxic cells. The purpose of this study was to find out the feasibility of I-131-Iodomisonidazole (IMISO) for imaging of tumor hypoxia. Materials and Methods: Tosyl precursor was dissolved in acetonitrile and I-131-NaI was added to synthesize IMISO. Balb/c mice inoculated with CT-26 adenocarcinoma were injected with IMISO. Mice were sacrificed at 1, 2, 4, 24 hr and % of injected dose per gram of tissue (%ID/g) was determined. For scintigraphy and MRI, mouse bearing CT-26 adenocarcinoma was administered with IMISO and imaging was performed 4 hr after. Then, mouse body was fixed and microtomized slice was placed on radiographic film for autoradiography Results: %ID/g of tumor was 1.64 (1h), 0.98 (2h), 0.85 (4h) and 0.20 (24h), respectively. At 24h, %ID/g of tumor was higher than that of all other tissues except thyroid. Tumor to muscle ratio increased with time and tumor to blood ratio also increased with time and reached 1.53 at 24 hr. On autoradiogram, tumor was well visualized as an increased activity in central hypoxic area of the tumor which corresponds to the area of high signal intensity on T2-weighted MR image. On scintigraphy, tumor uptake was visualized. Conclusion: This results suggest that IMISO may have a potential for tumor hypoxia imaging in mouse model. However, further study is needed to improve it's localization in tumor tissue and to achieve acceptable images of tumor hypoxia.

  • PDF

Diagnostic Role of F-18 FDG PET/CT in the Follow-up of Patients with Colorectal Cancer: Comparison with Serum CEA, CA 19-9 Levels and Computed Tomography (대장암 치료 후 추적 검사로서 F-18 FDG PET/CT의 역할: 혈청 CEA, CA 19-9 및 Computed Tomography와의 진단 성능 비교)

  • Kang, Sung-Min;Song, Bong-Il;Lee, Hong-Je;Seo, Ji-Hyoung;Lee, Sang-Woo;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Lee, Jae-Tae;Choi, Kyu-Suk;Jun, Soo-Han
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.120-128
    • /
    • 2009
  • Purpose: Early detection of recurrence is an important factor for long term survival of patients with colorectal cancer. Measurement of serum levels of CEA, CA 19-9, CT and PET/CT has been commonly used in the postoperative surveillance of colorectal cancer. The purpose of this study was to compare the diagnostic ability of PET/CT, tumor marker and CT for recurrence in colorectal cancer patients after treatment. Materials and Methods: F-18 FDG PET/CT imaging was performed in 189 colorectal cancer patients who underwent curative surgical resection and/or chemotherapy. Measurement of serum levels of CEA, CA 19-9 and CT imaging were performed within 2 months of PET/CT examination. Final diagnosis of recurrence was made by biopsy, radiologic studies or clinical follow-up for 6 months after each study. Results: Overall sensitivity, specificity of PET/CT was 94.7%, 91.1%, while those of serum CEA were 44.7% and 97.3%, respectively. Sensitivity and specificity were 94.2%, 90.4% for PET/CT and better than those of combined CEA and CA 19-9 measurement(52.1%, 88.5%) in 174 patients measured available both CEA and CA 19-9 data. In 115 patients with both tumor markers and CT images available, PET/CT showed similar sensitivity but higher specificity(92.9%, 91.3%) compared to combination of tumor markers and CT images(92.9%, 74.1%). Conclusion: PET/CT was superior for detection of recurred colorectal cancer patients compared with both CEA, CA 19-9, and even with combination of both tumor markers and CT. Therefore PET/CT could be used as a routine surveillance examination to detect recurrence or metastasis of colorectal cancer.

An Elimination of False-Positive I-131 Sites in Esophagus for Thyroid Carcinoma; Using Water with Vitamin C Dissolved (갑상선암의 방사성옥소 치료 후 전신 스캔에서 비타민C 용액을 이용한 식도의 위양성 병소 제거에 대한 고찰)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sa-Ron;Cho, Seok-Won;Choi, Young-Sook;Cho, Arther;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.49-56
    • /
    • 2008
  • Purpose: Whole body imaging with radioiodine can detect functioning metastases. Non-physiologic I-131 uptake detected on images usually is interpreted as suggesting functioning thyroid metastases. However, extra-thyroidal I-131 accumulation does not always imply thyroid cancer metastases and has been reported in many circumstances. In order to avoid unnecessary therapeutic interventions it is important to distinguish false-positive sites of I-131 localization. We study here to remove false-positive sites around esophagus region on I-131 whole body imaging in patients who were administrated thyroidectomy. Materials and Methods: From April to August in 2007, we had the patients who had visited our department after they received thyroidectomy due to thyroid cancer. They were given I-131, and performed radioiodine body scan after 41 to 50 hours. Patients were whole-body-scanned for the speed of 8 cm per minute. After that, we took anterior and posterior static images around the patients' neck measured by 300 thousand counts per image. We selected 44 patients who had hot spots around neck region, we divided the patients into two groups. One group was given 0.5 L of water and the other group was given 0.5 L of water with 1 g of Vitamin C dissolved. The patients were asked to drink the fluid for one minute in sitting position and after that, we measured 300 kilo counts per image again. We compared prior anterior, posterior static images with anterior, posterior images after the patients had water or water that Vitamin C resolved. Results: In using water, both observer 1 and 2 interpreted 6 patients were washed out. In the water with Vitamin C resolved, observer 1 and 2 interpreted 9 and 8 patients were washed out. Observer 1 and 2 interpreted 6 and 5 patients had 'indeterminate' when they used water. Both observer 1 and 2 interpreted 6 patients had 'indeterminate' when they used water with Vitamin C resolved. When they used water, observer 1 interpreted 10 patients had 'unchanged' and observer 2 interpreted 11 patients had 'unchanged'. Differently, when they used water with vitamin C resolved, observer1 had 8 patients having 'unchanged'and observer 2 had 9. Conclusion: As a result, by making patients drink 0.5 liter of water which has vitamin C resolved helped getting rid of false-positive sites in esophagus. Therefore, based on this study, we believe that drinking water with vitamin C dissolved is very in terms of reducing false-positive hot spot around the esophagus for the iodine-131 whole body scan.

  • PDF

Enzymatic properties of the N- and C-terminal halves of human hexokinase II

  • Ahn, Keun-Jae;Kim, Jong-Sun;Yun, Mi-Jin;Park, Jeon-Han;Lee, Jong-Doo
    • BMB Reports
    • /
    • v.42 no.6
    • /
    • pp.350-355
    • /
    • 2009
  • Although previous studies on hexokinase (HK) II indicate both the N- and C-terminal halves are catalytically active, we show in this study the N-terminal half is significantly more catalytic than the C-terminal half in addition to having a significantly higher $K_m$ for ATP and Glu. Furthermore, truncated forms of intact HK II lacking its first N-terminal 18 amino acids ($\Delta$18) and a truncated N-terminal half lacking its first 18 amino acids ($\Delta$18N) have higher catalytic activity than other mutants tested. Similar results were obtained by PET-scan analysis using $^{18}F-FDG$. Our results collectively suggest that each domain of HK II possesses enzyme activity, unlike HK I, with the N-terminal half showing higher enzyme activity than the C-terminal half.

Protective Effect of Fisetin (3,7,3',4'-Tetrahydroxyflavone) against γ-Irradiation-Induced Oxidative Stress and Cell Damage

  • Piao, Mei Jing;Kim, Ki Cheon;Chae, Sungwook;Keum, Young Sam;Kim, Hye Sun;Hyun, Jin Won
    • Biomolecules & Therapeutics
    • /
    • v.21 no.3
    • /
    • pp.210-215
    • /
    • 2013
  • Ionizing radiation can induce cellular oxidative stress through the generation of reactive oxygen species, resulting in cell damage and cell death. The aim of this study was to determine whether the antioxidant effects of the flavonoid fisetin (3,7,3',4'-tetrahydroxyflavone) included the radioprotection of cells exposed to ${\gamma}$-irradiation. Fisetin reduced the levels of intracellular reactive oxygen species generated by ${\gamma}$-irradiation and thereby protected cells against ${\gamma}$-irradiation-induced membrane lipid peroxidation, DNA damage, and protein carbonylation. In addition, fisetin maintained the viability of irradiated cells by partially inhibiting ${\gamma}$-irradiation-induced apoptosis and restoring mitochondrial membrane potential. These effects suggest that the cellular protective effects of fisetin against ${\gamma}$-irradiation are mainly due to its inhibition of reactive oxygen species generation.

Aliphatic radiofluorination using TBAHCO3 eluate in hydrous organic medium

  • Kwon, Young-Do;Son, Jeongmin;Chun, Joong-Hyun
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.4 no.2
    • /
    • pp.51-56
    • /
    • 2018
  • Azeotropic drying process is routinely applied to enhance nucleophilicity of $[^{18}F]$fluoride ion during the nucleophilic production of PET radiotracers; however, the drying process requires usually 15-25 min. Due to the high demand of employing fluorine-18 ($t_{1/2}=109.8min$) in PET radiopharmaceutical production, several research groups have focused on the method development, obviating tedious removal process of the residual target water ($[^{18}O]H_2O$) for $[^{18}F]$fluoride ion complex to be used in radiofluorination. Some development in radiofluorination in a mixed organic solvent system was demonstrated with various aliphatic substrates, but only kryptand as a phase transfer agent was utilized in the reported method. Here, we extend to investigate the development scope of applicability with basic alkyl ammonium salt as a phase transfer agent through the extensive elution efficiency study and radiofluorination outcome for aliphatic radiofluorination.

Radioisotopic and Radiological Evaluation in Patient with Stress Fracture (피로골절 환자에서 골주사 소견과 방사선 소견의 비교)

  • Ko, Kwang-Seop;Kim, Jai-Young;Kang, Sung-Koo;Kim, So-Yon;Lee, Gwon-Jun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.1
    • /
    • pp.39-46
    • /
    • 1987
  • The stress fracture is a disease caused by and abnormal stress to the normal bone with constant, repeated pull. Early detection of stress fracture plays an important role in treatment and prevention of its complication. Bone scintigraphy was performed to evaluate 18 patients with stress fracture of the lower extremities from May, 1985 to April, 1987, in the Department of Internal Medicine of National Police Hospital. The results were as follows: 1) Seventeen of the 18 cases showed positive bone scans at the initial study performed from 1 week to S months after the onset of symtom. 2) Ten of the 18 patients had findings of stress fracture at the initial X-ray film. Two out of 8 negative case revealed positive findings in the follow-up studies. 3) The bone scans in the 2 cases taken 5 months after the onset of symton; the one showed only slightly increased radiouptake, the other showed no abnormal findings. In conclusion, bone scanning is a more sensitive indicator of early stress fracture than radiologic study. The healing phase is characterized by a gradual decline in radioactivity at the fracture site in concordance with subsidence of symptom.

  • PDF

$^{99m}Tc-Red$ Blood Cell Scintigraphy of Sonographically Atypical Hemangioma (초음파상 비전형적 소견을 보이는 간혈관종의 적혈구 표지 스캔소견)

  • Lee, Kyoung-Soo;Lee, Ji-Young;Kim, Chan-Soo;Kim, Chang-Guhn;Choi, See-Sung;Won, Jong-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.338-345
    • /
    • 1992
  • We evaluated the scintigraphic findings of sonographically atypical hemangioma, that is, a hypoechoic or heterogeneously hypoechoic nodule which contains hypoechoic areas more than 40% of the volume, and compared it with those of sonographically typical hemangioma in 26 patients with 31 nodules. Sonographically atypical hemangioma were 13 in 11 patients and sonographically typical hemangioma were 18 the 15 patients. Dynamic blood flow, planar and SPECT blood pool imaging was performed. In atypical hemangioma, increased blood pool activity was seen in 11 of 13 nodules on SPECT and in 10 of 13 nodules on planar image and increased blood flow was seen in 4 of 13 nodules on dynamic blood flow study. No significant difference in detecting increased blood pool activity between sonographically atypical and typical hemangioma. In conclusion, $^{99m}Tc-red$ blood cell SPECT is as useful in diagnosis of sonographically atypical hemangioma as in typical hemangioma and can be used as a confirmatory or complementary study.

  • PDF

A Clinical Study of Serum Thyroglobulin Levels in Patients with Thyroid Tumor (갑상선종양환자(甲狀腺腫瘍患者)에서의 혈청(血淸) Thyroglobulin치(値)에 관(關)한 임상적(臨床的) 고찰(考察))

  • Lee, Choong-Kyu;Yu, Byung-Hee;Lee, Woo-Hyung;Yoo, Hyung-Joon;Lee, Chong-Suk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.17 no.1
    • /
    • pp.25-31
    • /
    • 1983
  • Serum thyroglobulin(Tg) was measured by radioimmunoassay in 81 patients with thyroid tumor who were treated in the department of Internal medicine of National Medical Center from January, 1981 to June, 1982. The results were as follows: 1) The mean serum thyroglobulin level in thyroid tumor was significantly higher than normal subjects (p<0.001). 2) The mean serum thyroglobulin level in benign tumor was lower than malignant tumor (p<0.05). 3) The thyroid carcinoma with metastasis had significant high level of serum thyroglobulin than without metastasis (p<0.001). 4) The mean postoperative serum thyroglobulin level was significantly lower than preoperative level (p<0.001). Data from our study show that serum thyroglobulin determination is useful for assessing the presence of malignant thyroid tumor, metastasis and the extent of residual or recurrent thyroid cancer after surgery.

  • PDF

A Study on the Thyroid Scan Images by Different Radionuclides ($^{99m}Tc$ pertechnetate and $^{131}I$) and Multiple Views (사용핵종(使用核種) 및 주사방향(走査方向)에 따른 갑상선주사상(甲狀腺走査像)의 차이(差異)에 관한 연구(硏究))

  • Whang, Il-Yong;Chung, Soon-Il;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.1
    • /
    • pp.53-58
    • /
    • 1986
  • Thyroid scans using $Na^{131}I\;and\;^{99m}TcO_4^-$ in two (anterior and anterior oblique) projections were done simultaneously in 50 patients with single palpable nodule and in euthyroid state(nodular nontoxic goiter) and 20 normal subjects to evaluate the imaging ability of each radionuclide and the necessity of oblique view. In detection of a nodule as a cold or cool area, $^{99m}TcO_4^-$ was slightly superior to $^{131}I$(82 % to 78% with anterior view alone, 92% to 84% when oblique view is added in detectability), with addition of an oblique view, 5 more cold or cool area in $^{99m}Tc$ scan and 3 more $^{131}I$ scan were detected. In normal subjects $^{99m}TcO_4^-$ scan was significantly superior to $^{131}I$ scan(90% to 70%) in getting normal pattern of tracer uptake in the glands. For routine imaging study of the thyroid, $^{99m}Tc$ pertechnetate scan with multiple projection is considered to be a preferable method.

  • PDF