• Title/Summary/Keyword: Nuclear medicine study

Search Result 2,876, Processing Time 0.029 seconds

Diagnosis of Coronary Artery Disease using Myocardial Perfusion SPECT in Patients with Diabetes Mellitus: Analysis of Risk Factors (당뇨병 환자에서 심근관류 SPECT을 이용한 관동맥질환의 진단: 위험인자 분석)

  • Seo, Ji-Hyoung;Kang, Seong-Min;Bae, Jin-Ho;Jeong, Shin-Young;Lee, Sang-Woo;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.155-162
    • /
    • 2006
  • Purpose: Diabetes mellitus (DM) is a critical disease with higher rates of cardiovascular morbidity and mortality due to myocardial ischemia and infarction. There is glowing interest in how to determine high-risk patients who are candidates for screening testing. This study was performed to evaluate the incidence of coronary artery disease (CAD) in diabetic patients detected by Tc-99m MIBI myocardial perfusion SPECT (MPS) and to assess risk factors of CAD and cardiac hard events. Subjects and Methods: 203 diabetic patients (64 male, mean age $64.1{\pm}9.0$ years) who underwent MPS were included between Jan 2000 and July 2004. Cardiac death and nonfatal myocardial infarction (MI) were considered as hard events, and coronary angioplasty and bypass surgery >60 days after testing were considered as soft events. The mean follow-up period was $36{\pm}18$ months. Patients underwent exercise (n=6) or adenosine stress (n=197) myocardial perfusion SPECT. Results: Perfusion defects on MPS were detected in 28.6% (58/203) of the patients. There was no cardiac death but 11 hard events were observed. The annual cardiac hard event rate was 1.1%. In univariate analysis of clinical factors, typical anginal pain, peripheral vascular disease, peripheral polyneuropathy, and resting ECG abnormality were significantly associated with the ocurrence of hard events. Anginal pain, peripheral vascular disease, and resting ECG abnormality remained independent predictors of nonfatal MIs with multivariate analysis. Abnormal SPECT results were significantly associated with high prevalence of hard events but not independent predictors on uni- and multivariate analyses. Conclusion: Patients who were male, had longer diabetes duration (especially over 20 years), peripheral vascular disease, peripheral polyneuropathy, or resting ECG abnormality had higher incidence of CAD. Among clinical factors in diabetic patients, typical angina, peripheral vascular disease, peripheral polyneuropathy, and resting ECG abnormality were strong predictors of hard events.

Evaluation of Endothelium-dependent Myocardial Perfusion Reserve in Healthy Smokers; Cold Pressor Test using $H_2^{15}O\;PET$ (흡연자에서 관상동맥 내피세포 의존성 심근 혈류 예비능: $H_2^{15}O\;PET$ 찬물자극 검사에 의한 평가)

  • Hwang, Kyung-Hoon;Lee, Dong-Soo;Lee, Byeong-Il;Lee, Jae-Sung;Lee, Ho-Young;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.21-29
    • /
    • 2004
  • Purpose: Much evidence suggests long-term cigarette smoking alters coronary vascular endothelial response. On this study, we applied nonnegative matrix factorization (NMF), an unsupervised learning algorithm, to CO-less $H_2^{15}O-PET$ to investigate coronary endothelial dysfunction caused by smoking noninvasively. Materials and methods: This study enrolled eighteen young male volunteers consisting of 9 smokers $(23.8{\pm}1.1\;yr;\;6.5{\pm}2.5$ pack-years) and 9 nonsmokers $(23.8{\pm}2.9 yr)$. They do not have any cardiovascular risk factor or disease history. Myocardial $H_2^{15}O-PET$ was performed at rest, during cold ($5^{\circ}C$) pressor stimulation and during adenosine infusion. Left ventricular blood pool and myocardium were segmented on dynamic PET data by NMF method. Myocardial blood flow (MBF) was calculated from input and tissue functions by a single compartmental model with correction of partial volume and spillover effects. Results: There were no significant difference in resting MBF between the two groups (Smokers: 1.43 0.41 ml/g/min and non-smokers: $1.37{\pm}0.41$ ml/g/min p=NS). during cold pressor stimulation, MBF in smokers was significantly lower than 4hat in non-smokers ($1.25{\pm}0.34$ ml/g/min vs $1.59{\pm}0.29$ ml/gmin; p=0.019). The difference in the ratio of cold pressor MBF to resting MBF between the two groups was also significant (p=0.024; $90{\pm}24%$ in smokers and $122{\pm}28%$ in non-smokers.). During adenosine infusion, however, hyperemic MBF did not differ significantly between smokers and non-smokers ($5.81{\pm}1.99$ ml/g/min vs $5.11{\pm}1.31$ ml/g/min ; p=NS). Conclusion: in smokers, MBF during cold pressor stimulation was significantly lower compared wi4h nonsmokers, reflecting smoking-Induced endothelial dysfunction. However, there was no significant difference in MBF during adenosine-induced hyperemia between the two groups.

Comparison of Image Uniformity Due to Position Shifting in COR on Myocardial SPECT (Myocardial SPECT시 COR에서 위치변화에 따른 Image Uniformity 비교)

  • Lim, Hyun-Jin;Kim, Joong-Hyun;Kim, Jae-Il;Lim, Jung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.70-75
    • /
    • 2012
  • Purpose: It is important to acquire accurate data because the SPECT scan affected by various physical factors. The aim of this study was to compare the uniformity when both centers were matched or mismatched differed from position of heart in COR. Materials and methods: The images were acquired with cylindrical uniform phantom (6.7 cm diameter, 9 cm length) and heart insert phantom using Cardio MD SPECT system (Philips, USA). The phantoms were positioned on COR as well as four different points which were 10 cm above, below, left and right side from the COR. The counts from the both edge of cylindrical uniform phantom and those from the both wall of heart insert phantom were compared by using vertical and horizontal line profile. In addition, the qualitative evaluation was performed with heart insert phantom images and volunteer test. Results: In heart insert phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 1.1, 4.1, 4.9, 2.2 and 0.9% using T-A curve for horizontal view. In case of vertical view of COR 3.9, 21.9, 3.5, 23.9, 14.0% were shown. In cylindrical phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 4.3, 0.3, 3.3, 2.6 and 0.7% using T-A curve for horizontal view. In case of vertical view of COR 2.7, 3.0, 1.0, 0.3, 3.4% were shown. For qualitative evaluation, the images at COR were the most uniform for both of heart insert phantom and volunteer test, whereas other four positions showed somewhat distorted images. Conclusion: It showed the most uniform images when COR is matched with the heart. Therefore, we can expect that distortion which increased or decreased of myocardial perfusion will be prevented by matching the heart and COR when positioning. Furthermore, the accuracy of diagnosis will be improved as well.

  • PDF

Study on the Usefulness of Using Anterior and Posterior Views for Calculation of Total Relative Uptake Ratio in 99mTc-DMSA Renal Scan (99mTc-DMSA 검사에서 상대 신섭취율 산출 시 양면상 촬영의 유용성에 대한 고찰)

  • Kim, Joo-Yeon;Lee, Han-Wool;Kwon, O-Jun;Kim, Jung-Yul;Park, Min-Soo;Cho, Seok-Won;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose $^{99m}Tc-DMSA$ renal scintigraphy serves as location, size and shape of kidney, so it has been used for diagnosis and passage observation after the operation or treatment. There are 3 methods of calculating the relative renal uptake ratio such as geometric mean of the counts from the anterior and posterior views, arithmetical mean from the only posterior view and posterior view which applied the renal depths. In this study, we seek to correlation between the change of total relative uptake ratio according to different inspection methods of obtaining the renal count rate. Materials and Methods The phantom experiments proceeded 5 times depending on each renal depth with the kidney phantom and tissue equivalent materials. In the clinical research, we investigated 36 adult patients who had visited our hospital from february to october, 2014 and received $^{99m}Tc-DMSA$ renal scan. The equipment was used as a gamma camera named INFINIA (General Electric Healthcare, milwaukee, USA) and we drew the region of interests through semiautomatic method by using Xeleris Ver. 2.1220 of GE. In addition, we obtained the lateral view of kidney to measure the renal depth of each patient. Then the results were compared with 3 methods of calculating relative renal uptake ratio. Results The phantom studies show when the difference between the left ant right kidney depth were less than 1 cm, there were no statistically significant difference among values calculated through anterior and posterior views and only posterior view (P>0.05), while the excess of 1cm, the results showed a statistically significant change in the value (P<0.05). In case of clinical research, the correlation between total relative uptake ratio by obtaining both sides of image and posterior view applied the kidney depth (r=0.999) was higher than by obtaining only posterior view and applying the kidney depth to one side image (r=0.988). Conclusion This study has found that, the difference of calculating total relative uptake ratio compared with obtaining anterior and posterior views and only posterior view. In order to reduce the error, we recommend the method of obtaining anterior and posterior views and is considered to be useful, particularly the patients have similar uptake ratio of left and right kidney and difficulties of measurements of kidney depth.

  • PDF

Building the Process for Reducing Whole Body Bone Scan Errors and its Effect (전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과)

  • Kim, Dong Seok;Park, Jang Won;Choi, Jae Min;Shim, Dong Oh;Kim, Ho Seong;Lee, Yeong Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.76-82
    • /
    • 2017
  • Purpose Whole body bone scan is one of the most frequently performed in nuclear medicine. Basically, both the anterior and posterior views are acquired simultaneously. Occasionally, it is difficult to distinguish the lesion by only the anterior view and the posterior view. In this case, accurate location of the lesion through SPECT / CT or additional static scan images are important. Therefore, in this study, various improvement activities have been carried out in order to enhance the work capacity of technologists. In this study, we investigate the effect of technologist training and standardized work process processes on bone scan error reduction. Materials and Methods Several systems have been introduced in sequence for the application of new processes. The first is the implementation of education and testing with physicians, the second is the classification of patients who are expected to undergo further scanning, introducing a pre-filtration system that allows technologists to check in advance, and finally, The communication system called NMQA is applied. From January, 2014 to December, 2016, we examined the whole body bone scan patients who visited the Department of Nuclear Medicine, Asan Medical Center, Seoul, Korea Results We investigated errors based on the Bone Scan NMQA sent from January 2014 to December 2016. The number of tests in which NMQA was transmitted over the entire bone scan during the survey period was calculated as a percentage. The annual output is 141 cases in 2014, 88 cases in 2015, and 86 cases in 2016. The rate of NMQA has decreased to 0.88% in 2014, 0.53% in 2015 and 0.45% in 2016. Conclusion The incidence of NMQA has decreased since 2014 when the new process was applied. However, we believe that it will be necessary to accumulate data continuously in the future because of insufficient data until statistically confirming its usefulness. This study confirmed the necessity of standardized work and education to improve the quality of Bone Scan image, and it is thought that update is needed for continuous research and interest in the future.

  • PDF

Fasudil Increases the Establishment of Somatic Cell Nuclear Transfer Embryonic Stem Cells in Mouse

  • So, Seongjun;Karagozlu, Mustafa Zafer;Lee, Yeonmi;Kang, Eunju
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.35 no.1
    • /
    • pp.21-27
    • /
    • 2020
  • Somatic cell nuclear transfer derived embryonic stem cells (NT-ESCs) have significant advantages in various fields such as genetics, embryology, stem cell science, and regenerative medicine. However, the poor establishment of NT-ESCs hinders various research. Here, we applied fasudil, a Rho-associated kinase (ROCK) inhibitor, to develop somatic cell nuclear transfer (SCNT) embryos and establish NT-ESCs. In the study, MII oocytes were isolated from female B6D2F1 mice and performed SCNT with mouse embryonic fibroblasts (MEFs). The reconstructed NT-oocytes were activated artificially, and cultured to blastocysts in KSOM supplemented with 10 μM fasudil. Further, the blastocysts were seeded on inactivated MEFs in embryonic stem cell medium supplemented with 10 μM fasudil. A total of 26% of embryos formed into blastocysts in the fasudil treated group, while this ratio was 44% in the fasudil free control group. On the other hand, 30% of blastocysts were established NT-ESCs after exposure of fasudil, which was significantly higher than the control group (10%). The results suggest that fasudil reduced blastocyst development after SCNT due to inhibition of 2 cell cleavage while improved the establishment of NT-ESCs through the anti-apoptotic pathway.

Prognostic Value of Restaging F-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography to Predict 3-Year Post-Recurrence Survival in Patients with Recurrent Gastric Cancer after Curative Resection

  • Sung Hoon Kim;Bong-Il Song;Hae Won Kim;Kyoung Sook Won;Young-Gil Son;Seung Wan Ryu
    • Korean Journal of Radiology
    • /
    • v.21 no.7
    • /
    • pp.829-837
    • /
    • 2020
  • Objective: The aim of this study was to investigate the prognostic value of the maximum standardized uptake value (SUVmax) measured while restaging with F-18 fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) to predict the 3-year post-recurrence survival (PRS) in patients with recurrent gastric cancer after curative surgical resection. Materials and Methods: In total, 47 patients with recurrent gastric cancer after curative resection who underwent restaging with 18F-FDG PET/CT were included. For the semiquantitative analysis, SUVmax was measured over the visually discernable 18F-FDG-avid recurrent lesions. Cox proportional-hazards regression models were used to predict the 3-year PRS. Differences in 3-year PRS were assessed with the Kaplan-Meier analysis. Results: Thirty-nine of the 47 patients (83%) expired within 3 years after recurrence in the median follow-up period of 30.3 months. In the multivariate analysis, SUVmax (p = 0.012), weight loss (p = 0.025), and neutrophil count (p = 0.006) were significant prognostic factors for 3-year PRS. The Kaplan-Meier curves demonstrated significantly poor 3-year PRS in patients with SUVmax > 5.1 than in those with SUVmax ≤ 5.1 (3-year PRS rate, 3.5% vs. 38.9%, p < 0.001). Conclusion: High SUVmax on restaging with 18F-FDG PET/CT is a poor prognostic factor for 3-year PRS. It may strengthen the role of 18F-FDG PET/CT in further stratifying the prognosis of recurrent gastric cancer.

Development and Validation of 18F-FDG PET/CT-Based Multivariable Clinical Prediction Models for the Identification of Malignancy-Associated Hemophagocytic Lymphohistiocytosis

  • Xu Yang;Xia Lu;Jun Liu;Ying Kan;Wei Wang;Shuxin Zhang;Lei Liu;Jixia Li;Jigang Yang
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.466-478
    • /
    • 2022
  • Objective: 18F-fluorodeoxyglucose (FDG) PET/CT is often used for detecting malignancy in patients with newly diagnosed hemophagocytic lymphohistiocytosis (HLH), with acceptable sensitivity but relatively low specificity. The aim of this study was to improve the diagnostic ability of 18F-FDG PET/CT in identifying malignancy in patients with HLH by combining 18F-FDG PET/CT and clinical parameters. Materials and Methods: Ninety-seven patients (age ≥ 14 years) with secondary HLH were retrospectively reviewed and divided into the derivation (n = 71) and validation (n = 26) cohorts according to admission time. In the derivation cohort, 22 patients had malignancy-associated HLH (M-HLH) and 49 patients had non-malignancy-associated HLH (NM-HLH). Data on pretreatment 18F-FDG PET/CT and laboratory results were collected. The variables were analyzed using the Mann-Whitney U test or Pearson's chi-square test, and a nomogram for predicting M-HLH was constructed using multivariable binary logistic regression. The predictors were also ranked using decision-tree analysis. The nomogram and decision tree were validated in the validation cohort (10 patients with M-HLH and 16 patients with NM-HLH). Results: The ratio of the maximal standardized uptake value (SUVmax) of the lymph nodes to that of the mediastinum, the ratio of the SUVmax of bone lesions or bone marrow to that of the mediastinum, and age were selected for constructing the model. The nomogram showed good performance in predicting M-HLH in the validation cohort, with an area under the receiver operating characteristic curve of 0.875 (95% confidence interval, 0.686-0.971). At an appropriate cutoff value, the sensitivity and specificity for identifying M-HLH were 90% (9/10) and 68.8% (11/16), respectively. The decision tree integrating the same variables showed 70% (7/10) sensitivity and 93.8% (15/16) specificity for identifying M-HLH. In comparison, visual analysis of 18F-FDG PET/CT images demonstrated 100% (10/10) sensitivity and 12.5% (2/16) specificity. Conclusion: 18F-FDG PET/CT may be a practical technique for identifying M-HLH. The model constructed using 18F-FDG PET/CT features and age was able to detect malignancy with better accuracy than visual analysis of 18F-FDG PET/CT images.

The Variation of Scan Time According to Patient's Breast Size and Body Mass Index in Breast Sentinel lymphangiography (유방암의 감시림프절 검사에서 유방크기와 체질량지수에 따른 검사시간 변화)

  • Lee, Da-Young;Nam-Koong, Hyuk;Cho, Seok-Won;Oh, Shin-Hyun;Im, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.62-67
    • /
    • 2012
  • Purpose : At this time, the sentinel lymph node mapping using radioisotope and blue dye is preceded for breast cancer patient's sentinel lymph node biopsy. But all patients were applied the same protocol without consideration of physical specific character like the breast sizes and body mass indexes. The purpose of this study is search the optimized scan time in breast sentinel lymphangiography by observing how much the body mass index and breast size influence speed of lymphatic flow. Materials and Methods : The Object of this study was 100 breast cancer patients(Female, 100 persons, average age $50.34{\pm}10.26$ years old)at Severance hospital from October 2011 to December 2011. They were scanned breast sentinel lymphangiography before operation. This study was performed on Forte dual heads gamma camera (Philips Medical Systems, Nederland B.V.). All patients were intra-dermal injected $^{99m}Tc$-Phytate 18.5 MBq, 0.5 ml. For 80 patients, we have scanned without limitation of scan time until the lymphatic flow from the lymph node since injection. We measured how long the lymphatic flow time between departures from injects site and arrival to lymph node using stopwatch. After we calculated patient's Body mass Index and classified as 4 groups. And we measured patient's breast size and classified 3 groups. The modified breast lymphangiography that changing scan time according to comparison study's result was performed on 20 patients and was estimated. Results : The mean scan time as breast size was A group 2.48 minutes, B group 7.69 minutes, C group 10.43 minutes. The mean scan time as body mass index was under weight 1.35 minutes, normal weight 2.56 minutes, slightly over 5.62 minutes, over weighted 5.62 minutes. The success rate of modified breast lymphangiography was 85%. Conclusion : As the Body mass index became higher and breast size became bigger, the total scan time is increased. Based on the obtained information, we designed modified breast lymphangiography protocol. At the cases applying that protocol, most of sentinel lymph nodes were visualized as lymphatic pool. In conclusion, we found that the more success rate in modified protocol considering physical individuality than study carrying out in the same protocol.

  • PDF

Agreement of three commercial anti-extractable nuclear antigen tests: EUROASSAY Anti-ENA Profile, Polycheck Autoimmune Test and FIDIS Connective Profile

  • Kim, Namhee;Kim, In-Suk;Chang, Chulhun L;Kim, Hyung-Hoi;Lee, Eun Yup
    • Kosin Medical Journal
    • /
    • v.33 no.3
    • /
    • pp.307-317
    • /
    • 2018
  • Background: Detection of antibodies to extractable nuclear antigens (ENAs) is needed for the diagnosis in systemic autoimmune diseases. In this study, we compared three reagents using line immunoblot assay (LIA) or multiplex bead immunoassay for detecting the anti-ENAs. Methods: A total of 89 sera were tested by 3 different assays: EUROASSAY Anti-ENA Profile (Euroimmune, Germany), Polycheck Autoimmune Test (Biocheck GmbH, Germany), and $FIDIS^{TM}$ Connective Profile (Biomedical Diagnostics, France). The following individual ENAs were investigated: Sm, SS-A (Ro), SS-B (La), Scl-70, Jo-1 and RNP. We reviewed medical records to investigate the discrepant results among three methods. Results: Overall percent agreements were 96.1% between EUROASSAY Anti-ENA Profile and $FIDIS^{TM}$ Connective profile; 90.4% between EUROASSAY Anti-ENA Profile and Polycheck Autoimmune Test using the manufacturers' cutoff; 96.4% between EUROASSAY Anti-ENA Profile and Polycheck Autoimmune Test using a upward cutoff; 90.4% between $FIDIS^{TM}$ Connective profile and Polycheck Autoimmune Test the manufacturers' cutoff; and 96.4% between $FIDIS^{TM}$ Connective profile and Polycheck Autoimmune Test a upward cutoff. Conclusions: The three assays showed excellent agreement with each other. With appropriate cutoff, the all three assays for six of the anti-ENA tests investigated in this study can be used in clinical laboratories for detecting the anti-ENAs.