• Title/Summary/Keyword: Nuclear medicine study

Search Result 2,876, Processing Time 0.027 seconds

Radioisotope Study in the Diagnosis of Pulmonary Arteriovenous Fistula (폐동정맥루(肺動靜脈瘻)에서 $^{99m}Tc-macroaggregated$ albumin 검사(檢査)의 의의)

  • Kim, Dong-Soon;Ahn, Il-Min
    • The Korean Journal of Nuclear Medicine
    • /
    • v.19 no.2
    • /
    • pp.65-68
    • /
    • 1985
  • The radioisotope study using $^{99m}Tc-macroaggregated$ Albumin is a simple, non-invasive test for the diagnosis of pulmonary arteriovenous fistula(PAVF). It can show the presence. of the right-to-left shunt at the lung level using the dynamic study, and also the shunt fraction can be estimated. Here we presented the results of the radioisotope study on two patients with PAVF. In one patient, the cardiac catheterization was clone and calculated shunt fractions by both method were well matched.

  • PDF

Sperm nuclear DNA fragmentation and chromatin structure in one-day-old ejaculated sperm

  • Jee, Byung-Chul;Suh, Chang-Suk;Shin, Mi-Sun;Lee, Hee-Jun;Lee, Jae-Ho;Kim, Seok-Hyun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.38 no.2
    • /
    • pp.82-86
    • /
    • 2011
  • Objective: To evaluate sperm nuclear DNA fragmentation and chromatin structure after 18 hours' incubation at room temperature. Methods: Twenty-eight male partners who participating IVF treatment were prospectively included in this study. Ejaculated sperm count and motility were assessed. The sperm was then immediately processed by the conventional swim-up method. After utilization of some of the sample for routine clinical use, the remainder of each of the samples was divided into two aliquots. One aliquot was immediately assessed for sperm nuclear DNA fragmentation (TUNEL assay) and chromatin structure (toluidine blue [TB] staining). The other aliquot was incubated at room temperature for 18 hours and then assessed by two methods. Only dark-TB sperms were considered as having abnormal chromatin structure. Data before and after extended incubation were compared using a paired Student's $t$-test. Results: Before and after extended culture, nuclear DNA fragmentation assessed by TUNEL was $4.9{\pm}4.7%$ and $7.0{\pm}6.4%$, respectively ($p$=0.008). The proportion of abnormal chromatin structure (dark-TB sperm) was $8.2{\pm}5.6%$ and $10.3{\pm}6.5%$ ($p$ <0.001), before and after incubation, respectively. Conclusion: After 18 hours' incubation at room temperature, sperm nuclear DNA and chromatin structure were significantly affected. The IVF practitioner should bear this information in mind when performing delayed insemination, especially for $in$ $vitro$ maturation cycles.

Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

Correction of Artifacts due to Patient Arm Motion in PET/CT: Scatter-Limit Correction (PET/CT 검사에서 움직임에 의한 인공물의 산란제한보정법 적용 영상 평가)

  • Bahn, Young Kag;Lee, Seung Jae;Kim, Jung Yul;Oh, Sin Hyun;Nam-Koong, Hyuk;Park, Hoon-Hee;Kang, Chun Koo;Lim, Han Sang;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.44-48
    • /
    • 2012
  • Purpose : Arm motion can give rise to striking cold artifact on PET/CT. We investigated that evaluation of scatter-limit correction and correct the patient arm motion artifact in Discovery 600 PET/CT. Materials and Methods : To evaluate a radioactivity uptake (Bq/ml) and a standard uptake value (SUV), the scatter limit correction and scatter correction were compared using 1994 NEMA Phantom$^{TM}$ in Discovery 600 PET/CT (GE Healthcare, Mi, We). Arm motion phantom study was involved a central 20 cm diameter cylinder simulating the neck and 2 peripheral 10 cm diameter cylinders simulating arms. The positions of the arms were altered so as to introduce different amounts of misalignment. The evaluation of arm motion phantom study used the radioactivity uptake and SUV in scatter correction and scatter limit correction. Results : The statistical significance of radioactivity uptake and SUV did not show the differences in comparisons of the scatter limit correction and the scatter correction that not show (p<0.05). Radioactivity uptake of the scatter correction was up to 3.1 kBq/ml in the 0.04 kBq/ml. It was approximately 98.7% undervalued in the arm motion phantom study. However, Radioactivity uptake of the scatter limit correction was up to 3.0 kBq/ml in the 2.11 kBq/ml. It was approximately 30% undervalued in arm motion phantom study. SUV of the scatter correction was 1.05 to 0.006 and underestimated about 98%. However, an applying SUV of the scatter limit correction changed the value as 0.67 which is underestimated about 25%. Radioactivity uptake and SUV of the scatter limit correction was increased approximately 60%, or more than the scatter correction. Conclusion : It is considered that if the patient arm motion artifact was occurred the scatter limit correction will be applicable to give an accurate diagnosis.

  • PDF

Study on Image Quality Assessment in Whole Body Bone Scan (전신 뼈검사에서의 영상 평가 연구)

  • Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.

  • PDF

A Study on the Quality Control of 2-site Immunoradiometric Assay of Serum Ferritin (혈청(血淸) ferritin 측정(測定)의 정도관리(精度管理)에 관(關)한 고찰(考察))

  • Kim, Byoung-Kook;Seo, Il-Tack;Kim, Kwang-Won;Cho, Bo-Yeon;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.14 no.1
    • /
    • pp.9-16
    • /
    • 1980
  • A 2-site immunoradiometric assay for serum ferritin was evaluated with commercially available kit. The assay required 6 hours. The slope of the standard curve kept up ideal range with the calculation of maxium binding instead of total dose until expire date. The stage II washing was more important than the stage I washing on the modified washing procedure as the bead keeping to remain in the tube. With this modified mothod, three times of tube. washing was sufficient to reduce the significant errors The measured values of serially diluted sample with standard diluting buffer was proportional to the predicted values. In the experiment of serum effect on the assay. a linear relationship from 5 to 50% serum, but beyond 50% there was reduction in measured ferritin concentration. It has a sensitivity of 2.77 ng/ml, within-assay precision (CV) of 8.0%, and between-assay reproducibility(CV) of 7.4% (mean 174.8 ng/ml).

  • PDF

The Usefulness of F-18 FDG Whole Body PET in the Evaluation of Postoperative Recurrence of Cancer (수술 후 암 재발 판정에 있어서 전신 F-18 FDG-PET의 유용성)

  • Kang, Won-Jun;So, Young;Jeong, Jae-Min;Kwark, Cheol-Eun;Lee, Dong-Soo;Kang, Soon-Bem;Jung, Hee-Won;Kim, Kwang-Hyun;Park, Jae-Gahb;Lee, Myung-Chul;Koh, Chang-Soon;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.372-380
    • /
    • 1997
  • The purpose of this study was to evaluate the usefulness of whole body F-18 FDG PET scan for detecting postoperative recurrence of cancer. One hundred four cancer patients after operation were enrolled(14 brain tumor, 15 head and neck cancer, 23 gynecologic cancer, 16 gastrointestinal cancer, 16 thyroid cancer, and 20 other cancers). Besides conventional images(CI) including CT and MRI, F-18 FDG PET scan was obtained on ECAT EXACT 47 scanner(Siemens-CTI), beginning 60 minutes after injection of 370MBq(10mCi) of F-18 FDG. Regional scan was also obtained with emission image. Transmission images using Ge-68 were carried out for attenuation correction in both whole body and regional images. Findings of PET, and CI were confirmed by pathology or clinical follow up. The sensitivity and specificity of PET for detecting recurrence were 94% and 92%, respectively. Contrarily, the sensitivity and specificity of CI were 78% and 68%. CI results were negative and PET results were positive in 11 cases. The biopsy or clinical follow-up of those cases confirmed recurrence of tumor. False negative cases of CI were frequent in patients with gynecologic cancers. Also we measured the serum concentration of tumor markers in patients with gynecologic cancer(CA125), thyroid cancer(thyroglobulin), and colorectal cancer(CEA). The sensitivity and specificity of tumor markers were 71% and 84%, respectively, We conclude that F-18 FDG PET can be used valuably in detecting recurrent foci of a wide variety of malignancy compared to conventional diagnostic methods.

  • PDF

Detection of Osteomyelitis Using a Tc-99m Labeled Antigranulocyte Antibody Immunoscintigraphy (Tc-99m 표지 항과립구항체 면역신티그라피를 이용한 골수염의 진단)

  • Kang, Won-Jun;Chung, June-Key;Yeo, Jeong-Seok;Hong, Mee-Kyoung;Jeong, Jae-Min;Lee, Dong-Soo;Lee, Sang-Hoon;Choi, In-Ho;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.344-353
    • /
    • 1998
  • Purpose: The purpose of this study was to evaluate the diagnostic accuracy of Tc-99m labeled antigranulocyte antibody immunoscintigrapy in the diagnosis of osteomyelitis and compare with the results of triphasic bone scan. Materials and Methods: The study population was 39 patients (22 male, 17 female) who had uncertain diagnoses of osteomyelitis. Fifteen patients had history of orthopedic surgery, and 5 had previous fracture. One milligram of monoclonal antibody against NCA-95 was labeled with 370 MBq of Tc-99m, injected intravenously, and 4 hour images were obtained. Triphasic bone scan images were obtained in 30 patients. The final diagnosis was confirmed by bacteriologic culture, biopsy or long term clinical follow up. Results: Twenty one patients were confirmed to have osteomyelitis (1 acute, 20 chronic). Eighteen patients were without osteomyelitis. Antigranulocyte antibody immunoscintigraphy had a sensitivity of 71% (15/21), and a specificity of 89% (16/18), while the sensitivity and specificity of triphasic bone scan was 93% (13/14) and 38% (6/16), respectively. Antigranulocyte antibody scan showed higher specificity of 100% (11/11) in comparison with 33% (3/9) of triphasic bone scan in patients with history of orthopedic surgery or fracture. Conclusion: Antigranulocyte antibody immunoscintigraphy is more specific than that of triphasic bone scan and may be helpful in patients with history of surgery or fracture. However, sensitivity is lower than triphasic bone scan in the detection of chronic osteomyelitis.

  • PDF

A Study on Radiolabelling Method in Radioimmunoassay -Part 1, A New Method for the $^{125}I-Labelling$ of Human Thyrotropin under Mild Conditions- (방사면역측정(放射免疫測定)에서 방사성(放射性) 동위원소(同位元素) 표식법(標識法) 개발에 관한 연구(硏究) -제1편(第1編). Human Thyrotropin의 온화한 조건하 $^{125}I$-표지를 위한 새로운 방법-)

  • Suh, Jung-Hun;Cho, Bo-Yeon;Park, Yong-Ja;Kim, Byong-Kook;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.15 no.2
    • /
    • pp.27-33
    • /
    • 1981
  • Human thyrotropin(h-TSH)의 $^{125}I$-표지를 실온서 소량의 Chloramine T를 산화제로 사용하여 수행하였다. 이 방법은 다량의 Chloramine T를 사용하는 종래의 방법과 비교하여 균일한 방사능 표지를 용이하게 하고 강력한 산화제인 Chloramine T에 의한 h-TSH의 파손을 줄여 주었다. 새로운 방법에 의해 합성된 $h-TSH^*$는 항체에 대한 친화도와 유효기간에 있어서 Daiichi 회사의 상품에 비교하여 손색이 없었다.

  • PDF

Aqueous extract of Lycii fructus suppresses inflammation through the inhibition of nuclear factor kappa B signal pathway in murine raw 264.7 macrophages

  • Kim, Beum-Seuk;Lim, Hyung-Ho;Song, Yun-Kyung;Sung, Yun-Hee;Kim, Sung-Eun;Chang, Hyun-Kyung;Shin, Mal-Soon;Kim, Chang-Ju;Lee, Hye-Jung;Kim, Dong-Hee
    • Advances in Traditional Medicine
    • /
    • v.10 no.3
    • /
    • pp.155-164
    • /
    • 2010
  • Lycii fructus is the fruit of Lycium chinense Miller and is part of the Solanaceae family. Lycii fructus produces various effects such as hypotensive, hypoglycemic, anti-pyretic, and anti-stress activities. Lycii fructus is known to contain betaine, carotene, nicotinic acid, zeaxanthin, and cerebroside. In the present study, the effects of Lycii fructus aqueous extract on lipopolysaccharide (LPS)-induced inflammation in murine raw 264.7 macrophage cells were investigated. In this study we utilized the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, reverse transcriptionpolymerase chain reaction (RT-PCR), Western blotting, and nitric oxide (NO) detection. Lycii fructus aqueous extract suppressed NO production by inhibiting the LPS-induced expressions of inducible nitric oxide synthase (iNOS) and tumor necrosis factor-alpha (TNF-$\alpha$) mRNA and iNOS protein in murine raw 264.7 macrophage cells. Also, Lycii fructus aqueous extract suppressed the activation of nuclear factor-kappa B (NF-${\kappa}B$) in the nucleus. These results demonstrated that Lycii fructus aqueous extract causes an anti-inflammatory effect that was likely produced by the suppression of iNOS expression through the down-regulation of NF-$\hat{e}B$ binding activity.